Latest Publications

  • Open Access

    New integrated autonomous solution for underground monitoring and mapping

    by Valerio Brunacci, Domenico Capriglione, Chiara Carissimo, Damiano Crescini, Filippo Milano, Antonio Moschitta, Giordano Piubeni, Giorgia Polidori, Cecilia Provenzale, Francesco Santoni, et al.

  • Open Access

    Validation of a Sensorized Forearm Crutch for Quantifying Partial Weight-Bearing During Assisted Gait Using Optical Motion Capture and Instrumented Treadmill

    by Soufiane Mahraoui, Gerrit Bücken, Stefan Ecker, Syed Ibrahim Shakir, Arndt-Peter Schulz, Neki Muhametaj, Mauro Serpelloni

    Human gait analysis is a key component of rehabilitation medicine, enabling objective assessment of patient recovery. In crutch-assisted locomotion, however, conventional forearm crutches operate as passive devices, providing no quantitative information on load distribution or patient adherence to partial weight-bearing (PWB) prescriptions. This work presents the design and dynamic validation of a sensorized forearm crutch system for biomechanical monitoring during assisted gait. The proposed device combines a force-sensing module based on a full Wheatstone bridge strain-gauge configuration with a 6-axis inertial measurement unit (IMU) to capture both axial load and crutch orientation. Sensor fusion was implemented through a complementary filter to estimate pitch and roll angles under dynamic conditions. The system was calibrated through static loading procedures and validated against reference instrumentation, including an optoelectronic motion capture system and an instrumented dual-belt treadmill with force platforms. Unlike previous studies relying on stationary force platforms that capture discrete steps and may alter natural gait, this validation approach enabled continuous, stride-by-stride force and orientation measurements without restricting foot placement. Experimental trials were conducted with unimpaired participants performing assisted gait using 2-point and 3-point patterns at two partial weight-bearing levels (20% and 40% body weight) and two walking speeds (0.80 m/s and 1.20 m/s). Dynamic validation showed good agreement with the treadmill reference, with force RMSE values of 9.33±1.70 N for the left crutch and 12.90±2.85 N for the right crutch, and with coefficients of determination of R2=0.9956 and R2=0.9927, respectively. Orientation RMSE values were 1.08±0.44° (roll, right), 2.06±0.56° (roll, left), 1.79±0.55° (pitch, right), and 1.66±0.37° (pitch, left). Beyond validation accuracy, the system enabled extraction of a set of quantitative biomechanical descriptors directly from crutch signals, axial load, cadence, crutch contact variability, load asymmetry, pitch asymmetry, and crutch stance/swing asymmetries, characterizing walking stability, bilateral coordination, and gait regularity during continuous assisted locomotion. These results demonstrate the feasibility of integrating force and inertial sensors into forearm crutches to enable quantitative monitoring of assisted gait, with potential applications in rehabilitation assessment and real-time feedback.

  • Open Access

    Ion-Selective Sensors for Orthopaedic Applications: A Systematic Review

    by Giorgia Polidori, Andrea Visani, Gianluca Giavaresi, Mauro Serpelloni, Gregorio Marchiori

    Sensors are an established driver of diagnostics and prevention in the medical field, including orthopaedics. Today, the subclass of ion-selective sensors (ISSs) is on the leading edge due to its advantages, enabled by technological advancements in manufacturing, such as miniaturization, precision, accuracy, specificity, a wide measuring scale, ease of use, flexible operating conditions, and measuring speed. While ISSs’ impact on environmental and health fields is already the subject of investigation, it still needs to be analysed specifically in orthopaedics, which is the aim of this Review. A PubMed and Scopus search was performed using the keywords “ion”, “sensor”, “electrodes”, “selective”, “musculoskeletal”, “implant”, “joint replacement”, and “orthopaedic”; after systematic screening, 44 studies were included in the synthesis. First, studies were classified based on the target ion. Only a few papers treated applications specifically in orthopaedics, confirming that ISSs are still largely an unexplored frontier here. However, all of the studies targeted ions with a role also in musculoskeletal pathophysiology, thus relative ISSs could have a potential impact on orthopaedic diagnosis and treatment. Then, when described by the papers, ISSs’ technological solutions were systematically evaluated. Finally, the main ISSs development targets for reaching orthopaedic clinical application were highlighted, including biocompatibility (e.g., implantability), long-term stability, calibration, and validation. Overcoming these challenges will enable ISSs to progress from laboratory prototypes to clinically viable tools, supporting the advancement of next-generation sensorised prostheses, fixation devices, and surgical instruments, and paving the way for predictive and personalised orthopaedic medicine.

  • Open Access

    Instrumentation and Measurement Methods for Industry 4.0 and IoT

    by Mauro Serpelloni

    The current industrial transformation is changing the way production systems are designed, manufactured, monitored, controlled, and maintained

  • Open Access

    Aerosol Jet Printed Ion-Selective Electrodes for Potassium Detection

    by Giorgia Polidori, Emilio Sardini, Mauro Serpelloni

    This work evaluates a potassium ion-selective electrode (K-ISE) fabricated using Aerosol Jet Printing (AJP) and compares its performance with that of a commercial K+-selective electrode (KION). Both sensors exhibit near-Nernstian behavior, with average sensitivities of 57.91 ± 5.07 mV/dec for the AJP device and 57.28 ± 5.07 mV/dec for the commercial electrode, confirming a near-Nernstian K+ response over the tested concentration range. Single-interferent response tests demonstrate that AJP-printed electrodes provide a more stable and less sensitive response to sodium interference (24.37 ± 1.39 mV/dec) compared to KION (33.95 ± 8.95 mV/dec), while showing comparable NH4+ response and a slightly higher response toward urea than KION. Morphological analysis (OM and SEM) reveals that AJP enables smoother, more homogeneous films and improved control over the transducer/membrane interface. Unlike previous studies, this work presents a direct experimental comparison between AJP-fabricated and commercial ISEs under controlled interference conditions relevant to agricultural and environmental matrices. Although the AJP sensors exhibited near-Nernstian behavior and fast response times, their reproducibility was lower than that of the commercial electrodes (RSD = 30.12% vs. 18.45%), indicating that further optimization of the printing and membrane deposition processes is required.


  • Open Access

    Wireless Instrumented Ankle Foot Orthosis (AFO) for Gait Cycle Monitoring

    by Soufiane Mahraoui, Mauro Serpelloni

    Ankle–foot orthoses (AFOs) are widely used in the rehabilitation of patients with neurological or musculoskeletal disorders. However, treatment outcomes may be influenced by incorrect use of the device or by inappropriate orthosis selection. Since many types of AFOs are available, differing in materials, stiffness, and geometry, an objective evaluation tool can support clinical decision-making. This work presents the design, development, and characterization of an instrumented AFO able to quantify relevant gait parameters in an objective way. The proposed device integrates three measurement modalities in a compact wearable structure. Two longitudinal strain gauges estimate ankle plantar- and dorsiflexion angles. Two force-sensitive elements detect foot–ground contact and allow identification of stance and swing phases of the gait cycle. A single inertial measurement unit (IMU) is used to measure lateral shank inclination. The strain-gauge-based angle estimation was validated against a gold-standard motion capture system, achieving a root mean square error of approximately 1.6 degrees and showing higher accuracy than the IMU for plantar/dorsiflexion measurement, while maintaining a simple electronic architecture. The force sensors were validated using a force platform and demonstrated reliable detection of loading and unloading events. Monitoring lateral inclination through the single IMU provides additional information related to balance and potential fall risk. Data are transmitted via Bluetooth Low Energy (BLE) to a custom Python-based application for real-time visualization and recording. Overall, the results validate the electronic instrumentation and demonstrate reliable system performance, indicating that the proposed instrumented AFO represents a promising platform for objective gait assessment and future clinical applications.


  • Open Access

    Single transient exposure to low-frequency low-intensity electrical stimulation produces ketamine-like effects in human iPSC-derived dopaminergic neurons via Ca2+-dependent BDNF and mTOR signaling

    by Giulia Sofia Marcotto, Michela Borghetti, Jonida Bitraj, Laura Cavalleri, Mauro Serpelloni, Michele Zoli, Maurizio Memo, Emilio Sardini, Ginetta Collo

  • Open Access

    Voltage-based balancing technique for half printed Wheatstone bridges

    by Michela Borghetti, Emilio Sardini, Mauro Serpelloni


  • Design and experimental characterization of a small flexible TMR-based indentation probe for soft tissue hardness estimation

    by Giacomo Santona, Antonio Fiorentino, Francesco Doglietto, Mauro Serpelloni

    The endoscopic transsphenoidal approach is a surgical method used to remove pituitary adenomas—benign tumors located near the pituitary gland. The success of this procedure depends heavily on assessing the tumor’s consistency, which is currently based on the surgeon’s tactile feedback and experience. This study presents the development of a novel sensor-based probe designed to provide real-time measurements of tissue hardness, supporting more objective surgical decision-making. The probe integrates a tunneling magneto resistance (TMR) sensor with a deformable, 3D-printed tip made of thermoplastic polyurethane. The tip features micro-beams that deform upon contact with tissue; the extent of deformation, measured by the TMR sensor, correlates with tissue stiffness. The flexible structure was fabricated using fused filament fabrication, and the process was characterized to control micro-beam dimensions by adjusting print parameters such as layer height, print speed, and nominal line width. A regression model was developed to predict beam width with high accuracy and repeatability. Eighteen probe designs, combining different beam widths (0.42 mm–0.63 mm) and numbers (3–5), were tested through indentation experiments on samples with Shore 000 hardness ranging from 51 to 83 (ASTM D2240), including a cooked egg white sample as a biological tissue analogue. Results revealed that probes with 4 and 5 beams printed at lower speeds offered superior sensitivity, linearity, and uniformity. In these configurations, the probe was able to estimate the hardness of adenoma-like materials with errors below 2%. These findings validate the proposed system’s potential for clinical use in evaluating soft to moderately firm tumors during surgery.


  • Novel Method for Balancing Full Wheatstone Bridge for High-Tolerance Resistive Sensors

    by Michela Borghetti, Oscar Casas, Emilio Sardini, Mauro Serpelloni

    Wheatstone bridge (WB) is widely used in precision measurements involving strain gauges and resistive sensors. However, maintaining balance in a full-bridge configuration becomes increasingly challenging in the presence of high-resistance tolerances—especially in printed electronics, where such variations are common. Traditional compensation methods often entail increased circuit complexity, added cost, and additional sources of error. This paper proposes a novel balancing technique for fully resistive Wheatstone bridges, leveraging two voltage references to cancel the output offset even in the presence of resistor tolerances exceeding 0.1%. The method demonstrates robust performance with tolerance levels up to 20%, while preserving high linearity. Simulation results confirm that the approach achieves balanced operation and accurate output even with low-tolerance resistors (1%). Relative to the ideal sensitivity of (VCC−VEE), the proposed technique maintains a worst-case sensitivity of 0.8 (VCC−VEE), with a theoretically null output offset under balanced conditions. Furthermore, linearity error remains below 0.5% of the full-scale output (FSO), matching the performance of conventional WB circuits affected by mismatch. While the resolution of the voltage references introduces a small, predictable offset—independent of power supply variations—this error is limited to the resolution of the reference itself. Experimental validation using benchtop instrumentation corroborates the simulation findings: with resistors exhibiting 10% tolerance, the maximum deviation between measured and theoretical outputs was 2.4 mV. This deviation remains negligible in terms of estimating fractional resistance changes.