Neil Brysiewicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Neil Brysiewicz has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
David J. Wilber
4 shared publicationsJoseph G. Akar
Yale University School of Medicine, New Haven Connecticut
4 shared publicationsMichael Porter
Cardiovascular Institute, Loyola University Medical Center, Maywood, Illinois, USA
3 shared publicationsNiraj Varma
3 shared publicationsPeter Santucci
Cardiovascular Institute, Loyola University Medical Center, Maywood, Illinois, USA
3 shared publications- Joseph G. Akar
Section of Cardiovascular Medicine Yale University School of Medicine New Haven Connecticut USA
2 shared publications
Latest Publications
- 1 August 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (8) , e9-e51
Heart Rhythm Society Expert Consensus Statement on Electrophysiology Laboratory Standards: Process, Protocols, Equipment, Personnel, and Safety
- 1 August 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (8) , e9-e51
Heart Rhythm Society Expert Consensus Statement on Electrophysiology Laboratory Standards: Process, Protocols, Equipment, Personnel, and Safety
- 1 January 2014
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 7 (1) , 97-100
3D Real-Time Intracardiac Echocardiographic Visualization of Atrial Structures Relevant to Atrial Fibrillation Ablation
- 1 January 2014
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 7 (1) , 97-100
3D Real-Time Intracardiac Echocardiographic Visualization of Atrial Structures Relevant to Atrial Fibrillation Ablation
- 10 January 2013
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 36 (6) , 781-788
Use of Intracardiac Echocardiography during Atrial Fibrillation Ablation
As the volume and complexity of catheter ablation of atrial fibrillation (AF) continue to rise, there is increasing attention directed at reducing exposure to ionizing radiation. This has led to the emergence of intracardiac echocardiography (ICE) as a stand‐alone imaging modality guiding AF ablation. In addition to directing transseptal puncture, ICE may be used to identify left atrial structures and to guide the manipulation of catheters. ICE may also be used to visualize the esophagus in real‐time and to assist with early identification of procedural complications. This review provides detailed step‐by‐step directions for identification of relevant structures and summarizes the use of ICE during AF ablation.
- 10 January 2013
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 36 (6) , 781-788
Use of Intracardiac Echocardiography during Atrial Fibrillation Ablation
As the volume and complexity of catheter ablation of atrial fibrillation (AF) continue to rise, there is increasing attention directed at reducing exposure to ionizing radiation. This has led to the emergence of intracardiac echocardiography (ICE) as a stand‐alone imaging modality guiding AF ablation. In addition to directing transseptal puncture, ICE may be used to identify left atrial structures and to guide the manipulation of catheters. ICE may also be used to visualize the esophagus in real‐time and to assist with early identification of procedural complications. This review provides detailed step‐by‐step directions for identification of relevant structures and summarizes the use of ICE during AF ablation.
- 1 November 2009
- Published by Elsevier in Heart Rhythm
- Vol. 6 (11) , 1586-1595
Electroanatomic mapping of postpacing intervals clarifies the complete active circuit and variants in atrial flutter
- 1 November 2009
- Published by Elsevier in Heart Rhythm
- Vol. 6 (11) , 1586-1595
Electroanatomic mapping of postpacing intervals clarifies the complete active circuit and variants in atrial flutter
- 28 June 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (6) , 613-620
Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms
Introduction: Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. Methods and Results: In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 ± 18 sites/patient were identified (20 ± 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow‐up was 1 year. One‐year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Conclusions: Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long‐term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.
- 28 June 2008
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (6) , 613-620
Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms
Introduction: Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. Methods and Results: In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 ± 18 sites/patient were identified (20 ± 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow‐up was 1 year. One‐year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Conclusions: Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long‐term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.
- 18 April 2008
- Published by Wiley
- p. 240-255
Electrogram‐Guided Approach to Ablation of Atrial Fibrillation
- 18 April 2008
- Published by Wiley
- p. 240-255
Electrogram‐Guided Approach to Ablation of Atrial Fibrillation
- 21 February 2007
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (4) , 349-355
Surface Electrocardiographic Patterns and Electrophysiologic Characteristics of Atrial Flutter Following Modified Radiofrequency MAZE Procedures
Introduction: The radiofrequency MAZE is becoming a common adjunct to cardiac surgery in patients with atrial fibrillation. While a variety of postoperative arrhythmias have been described following the original Cox‐MAZE III procedure, the electrophysiological characteristics and surgical substrate of post‐radiofrequency MAZE flutter have not been correlated. We sought to determine the location, ECG patterns, and electrophysiological characteristics of post‐radiofrequency MAZE atrial flutter. Methods: Nine consecutive patients with post‐radiofrequency MAZE flutter presented for catheter ablation 9 ± 10 months after surgery. Results: Only one patient (11%) had an ECG appearance consistent with typical isthmus‐dependent right atrial (RA) flutter. However, on electrophysiological study, 3/9 patients (33%) had typical right counter‐clockwise flutter entrained from the cavo‐tricuspid isthmus, despite description of surgical isthmus ablation. Six patients (67%) had left atrial (LA) circuits. These involved the mitral annulus in 5/6 cases (83%) despite description of surgical mitral isthmus ablation in the majority (60%). LA flutters had a shorter cycle length compared with RA flutters (253 ± 39 msec and 332 ± 63 msec respectively, P < 0.05). After a mean of 8 ± 4 months following ablation, 8/9 patients (89%) were in sinus rhythm. Conclusion: Up to one‐third of post‐radiofrequency MAZE circuits are typical isthmus‐dependent RA flutters, despite a highly atypical surface ECG morphology. Therefore, diagnostic electrophysiological studies should commence with entrainment at the cavo‐tricuspid isthmus in order to exclude typical flutter, regardless of the surface ECG appearance. Incomplete surgical lesions at the mitral and cavo‐tricuspid isthmus likely predispose to the development of post‐radiofrequency MAZE flutter.
- 21 February 2007
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (4) , 349-355
Surface Electrocardiographic Patterns and Electrophysiologic Characteristics of Atrial Flutter Following Modified Radiofrequency MAZE Procedures
Introduction: The radiofrequency MAZE is becoming a common adjunct to cardiac surgery in patients with atrial fibrillation. While a variety of postoperative arrhythmias have been described following the original Cox‐MAZE III procedure, the electrophysiological characteristics and surgical substrate of post‐radiofrequency MAZE flutter have not been correlated. We sought to determine the location, ECG patterns, and electrophysiological characteristics of post‐radiofrequency MAZE atrial flutter. Methods: Nine consecutive patients with post‐radiofrequency MAZE flutter presented for catheter ablation 9 ± 10 months after surgery. Results: Only one patient (11%) had an ECG appearance consistent with typical isthmus‐dependent right atrial (RA) flutter. However, on electrophysiological study, 3/9 patients (33%) had typical right counter‐clockwise flutter entrained from the cavo‐tricuspid isthmus, despite description of surgical isthmus ablation. Six patients (67%) had left atrial (LA) circuits. These involved the mitral annulus in 5/6 cases (83%) despite description of surgical mitral isthmus ablation in the majority (60%). LA flutters had a shorter cycle length compared with RA flutters (253 ± 39 msec and 332 ± 63 msec respectively, P < 0.05). After a mean of 8 ± 4 months following ablation, 8/9 patients (89%) were in sinus rhythm. Conclusion: Up to one‐third of post‐radiofrequency MAZE circuits are typical isthmus‐dependent RA flutters, despite a highly atypical surface ECG morphology. Therefore, diagnostic electrophysiological studies should commence with entrainment at the cavo‐tricuspid isthmus in order to exclude typical flutter, regardless of the surface ECG appearance. Incomplete surgical lesions at the mitral and cavo‐tricuspid isthmus likely predispose to the development of post‐radiofrequency MAZE flutter.
- 1 May 2006
- Published by Elsevier in Heart Rhythm
- Vol. 3 (5) , S329-329
P6-84