Marc S. Kraus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marc S. Kraus has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Anna R. Gelzer
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Studies and Advanced Medicine Philadelphia, Pennsylvania
6 shared publications - Mark A. Oyama
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Sciences and Advanced Medicine Philadelphia, Pennsylvania
5 shared publications Kerry A. Loughran
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Sciences and Advanced Medicine Philadelphia, Pennsylvania
4 shared publicationsErin J. Achilles
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Sciences and Advanced Medicine Philadelphia, Pennsylvania
3 shared publicationsLaura K. Massey
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Sciences and Advanced Medicine Philadelphia, Pennsylvania
3 shared publicationsTerry Huh
School of Veterinary Medicine, University of Pennsylvania Department of Clinical Sciences and Advanced Medicine Philadelphia, Pennsylvania
3 shared publications
Latest Publications
- 15 May 2025
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 60, 30-35
Open atrial septal defect repair in a dog using fresh autologous pericardium
- 15 May 2025
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 60, 30-35
Open atrial septal defect repair in a dog using fresh autologous pericardium
- Open Access
- 1 November 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (6) , 3016-3024
Observed and expected reliability of echocardiographic volumetric methods and critical change values for quantification of mitral regurgitant fraction in dogs
Background: Reliability of echocardiographic calculations for stroke volume and mitral regurgitant fraction (RFMR) are affected by observer variability and lack of a gold standard. Variability is used to calculate critical change values (CCVs) that are thresholds representing real change in a measure not associated with observer variability. Hypothesis: Observed intra- and interobserver accuracy and variability in healthy dogs help model CCV for RFMR. Animals: Reliability cohort of 34 healthy dogs; allometric scaling cohort of 99 dogs with heart disease and 25 healthy dogs. Methods: Accuracy, variability, and CCV of 2 observers using geometric and flow-based echocardiography were prospectively compared against a standard of RFMR = 0% and extrapolated across a range of expected RFMR values in the reliability cohort partly derived from cardiac dimensions predicted by the allometric cohort. Results: Accuracy of methods to determine RFMR in descending order was 4-chamber bullet (Bullet4CH), mitral inflow, cube formula, and Simpson's method of disks. Intraobserver variability was relatively high. The CCV for RFMR ranged from 28% to 88% and was inversely related to RFMR when extrapolated for use in affected dogs. For both observers, the Bullet4CH method had the lowest intraobserver CCV (Operator 1:28%, Operator 2:41%). Interobserver strength of agreement was low with intraclass correlation coefficients ranging from 0.210 to 0.413. Conclusions and Clinical Importance: Echocardiographic volumetric methods used to calculate stroke volume and RFMR have low accuracy and high variability in healthy dogs. Extrapolation of observed CCV to a range of expected RFMR suggests observers and methods are not interchangeable and variability might hinder routine clinical usage. Individual observers should be aware of their own variability and CCV.
- 1 November 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (6) , 3016-3024
Open AccessObserved and expected reliability of echocardiographic volumetric methods and critical change values for quantification of mitral regurgitant fraction in dogs
Background: Reliability of echocardiographic calculations for stroke volume and mitral regurgitant fraction (RFMR) are affected by observer variability and lack of a gold standard. Variability is used to calculate critical change values (CCVs) that are thresholds representing real change in a measure not associated with observer variability. Hypothesis: Observed intra- and interobserver accuracy and variability in healthy dogs help model CCV for RFMR. Animals: Reliability cohort of 34 healthy dogs; allometric scaling cohort of 99 dogs with heart disease and 25 healthy dogs. Methods: Accuracy, variability, and CCV of 2 observers using geometric and flow-based echocardiography were prospectively compared against a standard of RFMR = 0% and extrapolated across a range of expected RFMR values in the reliability cohort partly derived from cardiac dimensions predicted by the allometric cohort. Results: Accuracy of methods to determine RFMR in descending order was 4-chamber bullet (Bullet4CH), mitral inflow, cube formula, and Simpson's method of disks. Intraobserver variability was relatively high. The CCV for RFMR ranged from 28% to 88% and was inversely related to RFMR when extrapolated for use in affected dogs. For both observers, the Bullet4CH method had the lowest intraobserver CCV (Operator 1:28%, Operator 2:41%). Interobserver strength of agreement was low with intraclass correlation coefficients ranging from 0.210 to 0.413. Conclusions and Clinical Importance: Echocardiographic volumetric methods used to calculate stroke volume and RFMR have low accuracy and high variability in healthy dogs. Extrapolation of observed CCV to a range of expected RFMR suggests observers and methods are not interchangeable and variability might hinder routine clinical usage. Individual observers should be aware of their own variability and CCV.
- Open Access
- 1 May 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (3) , 1325-1333
Utility of focused cardiac ultrasonography training in veterinary students to differentiate stages of subclinical myxomatous mitral valve disease in dogs
Background: Differentiation of the subclinical phases of myxomatous mitral valve disease (MMVD) in dogs relies heavily on echocardiography. Focused cardiac ultrasonography (FCU) is a point-of-care technique that can assess heart size. Hypothesis/Objectives: Veterinary students trained in FCU can differentiate dogs with subclinical MMVD based on left ventricular (LV) and left atrial (LA) dimensions. Animals: Forty-eight dogs with subclinical MMVD. Methods: Veterinary students were trained to measure LV dimension and LA-to-aortic root dimension ratio (LA : Ao) using FCU. Dogs were categorized into 2 cohorts based on whether or not the LV normalized internal diastolic dimension was ≥1.7 and LA : Ao was ≥1.6. Agreement between FCU and echocardiographic studies performed by cardiologists was evaluated. Results: One-hundred and forty-six FCU examinations were performed by 58 veterinary students on 48 dogs. Overall agreement between students and cardiologists was moderate (Fleiss' kappa, 0.54; 95% confidence interval [CI], 0.39-0.69; P < .001). Percentage accuracy in observations with heart dimensions less than the cutoffs (86/89, 97%) was significantly higher than in observations in with larger hearts (31/57, 54%; P < .001). Agreement increased from moderate to good as heart sizes became more extreme. Degree of confidence by students in performing FCU was significantly higher at the end vs start of the study. Conclusions and Clinical Importance: Categorization of dogs with subclinical MMVD by veterinary students using FCU was associated with moderate to good agreement with echocardiography. Focused cardiac ultrasonography is a point-of-care method that can help assess clinical stage in dogs with subclinical MMVD.
- 1 May 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (3) , 1325-1333
Open AccessUtility of focused cardiac ultrasonography training in veterinary students to differentiate stages of subclinical myxomatous mitral valve disease in dogs
Background: Differentiation of the subclinical phases of myxomatous mitral valve disease (MMVD) in dogs relies heavily on echocardiography. Focused cardiac ultrasonography (FCU) is a point-of-care technique that can assess heart size. Hypothesis/Objectives: Veterinary students trained in FCU can differentiate dogs with subclinical MMVD based on left ventricular (LV) and left atrial (LA) dimensions. Animals: Forty-eight dogs with subclinical MMVD. Methods: Veterinary students were trained to measure LV dimension and LA-to-aortic root dimension ratio (LA : Ao) using FCU. Dogs were categorized into 2 cohorts based on whether or not the LV normalized internal diastolic dimension was ≥1.7 and LA : Ao was ≥1.6. Agreement between FCU and echocardiographic studies performed by cardiologists was evaluated. Results: One-hundred and forty-six FCU examinations were performed by 58 veterinary students on 48 dogs. Overall agreement between students and cardiologists was moderate (Fleiss' kappa, 0.54; 95% confidence interval [CI], 0.39-0.69; P < .001). Percentage accuracy in observations with heart dimensions less than the cutoffs (86/89, 97%) was significantly higher than in observations in with larger hearts (31/57, 54%; P < .001). Agreement increased from moderate to good as heart sizes became more extreme. Degree of confidence by students in performing FCU was significantly higher at the end vs start of the study. Conclusions and Clinical Importance: Categorization of dogs with subclinical MMVD by veterinary students using FCU was associated with moderate to good agreement with echocardiography. Focused cardiac ultrasonography is a point-of-care method that can help assess clinical stage in dogs with subclinical MMVD.
- Open Access
- 1 May 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (3) , 1751-1764
Twenty-four hour continuous transvenous temporary right ventricular pacing in healthy horses
Background: The ability to perform transvenous temporary cardiac pacing (TV-TP) is critical to stabilize horses with symptomatic bradyarrhythmias. Reports of successful TV-TP in horses are limited, and only briefly describe short-term pacing. Objective: To describe temporary, medium-term (24 h) transvenous right ventricular pacing in awake horses using a bipolar torque-directed pacing catheter. Animals: Six healthy adult institutional teaching horses. Methods: Prospective experimental study with 2 immediately successive TV-TP lead placements in each horse with a target location of the RV apex. One placement was performed primarily with echocardiographic guidance and 1 primarily with fluoroscopic guidance. In all placements, corresponding images were obtained with both imaging modalities. Horses were then paced for 24 h, unrestricted in a stall with continuous telemetric ECG monitoring. Echocardiographically determined lead position, episodes of pacing failure in the preceding 6 h, and pacing thresholds were recorded every 6 h. Pacing failure was defined as a period of loss of capture longer than 20 s. Results: Pacing leads were placed with both guidance methods and maintained for 24 h with no complications. Two horses with leads angled caudally in the right ventricular apex had no pacing failure, the remaining 4 horses had varying degrees of loss of capture. Leads located in the right ventricular apex had longer time to pacing failure and lower capture thresholds P < 0.05. Conclusions and Clinical Importance: Medium-term TV-TP is feasible and has potential for stabilization of horses with symptomatic bradyarrhythmias. Lead position in the right ventricular apex appears optimal. Continuous ECG monitoring is recommended to detect pacing failure.
- 1 May 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (3) , 1751-1764
Open AccessTwenty-four hour continuous transvenous temporary right ventricular pacing in healthy horses
Background: The ability to perform transvenous temporary cardiac pacing (TV-TP) is critical to stabilize horses with symptomatic bradyarrhythmias. Reports of successful TV-TP in horses are limited, and only briefly describe short-term pacing. Objective: To describe temporary, medium-term (24 h) transvenous right ventricular pacing in awake horses using a bipolar torque-directed pacing catheter. Animals: Six healthy adult institutional teaching horses. Methods: Prospective experimental study with 2 immediately successive TV-TP lead placements in each horse with a target location of the RV apex. One placement was performed primarily with echocardiographic guidance and 1 primarily with fluoroscopic guidance. In all placements, corresponding images were obtained with both imaging modalities. Horses were then paced for 24 h, unrestricted in a stall with continuous telemetric ECG monitoring. Echocardiographically determined lead position, episodes of pacing failure in the preceding 6 h, and pacing thresholds were recorded every 6 h. Pacing failure was defined as a period of loss of capture longer than 20 s. Results: Pacing leads were placed with both guidance methods and maintained for 24 h with no complications. Two horses with leads angled caudally in the right ventricular apex had no pacing failure, the remaining 4 horses had varying degrees of loss of capture. Leads located in the right ventricular apex had longer time to pacing failure and lower capture thresholds P < 0.05. Conclusions and Clinical Importance: Medium-term TV-TP is feasible and has potential for stabilization of horses with symptomatic bradyarrhythmias. Lead position in the right ventricular apex appears optimal. Continuous ECG monitoring is recommended to detect pacing failure.
- Open Access
- 1 January 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (1) , 71-80
Urine sodium concentration after intravenous furosemide in dogs with acute congestive heart failure and correlation with treatment efficacy
Background: Poor natriuresis is a potential marker of diuretic resistance in dogs with acute congestive heart failure (CHF) but little is known about the relationship between urine sodium concentration (uNa) and frequency of successful decongestion. Supplemental O2 is a common treatment in dogs with severe CHF. The time from start to discontinuation of supplemental O2 therapy (DCSO2) typically reflects the time course and ease of decongestion. Hypothesis/Objectives: Urine Na concentration after IV administration of furosemide will be correlated with duration of treatment with supplemental O2 (timeO2) and the cumulative frequency of successful DCSO2 during hospitalization. Animals: Fifty-one dogs with acute CHF. Methods: Retrospective observational single center study. Results: Dogs with low uNa had significantly longer mean timeO2 than dogs with high uNa (uNa <87 mmol/L, 24.2 ± 2.6 hours vs uNa ≥87 mmol/L, 16.6 ± 1.7 hours; P = .02). Low uNa was correlated with lower cumulative frequency of DCSO2 (12 hour, 28%; 24 hour, 42%; 36 hour, 73%) compared to high uNa (12 hour, 28%; 24 hour, 88%; 36 hour, 96%; P = .005). History of PO loop diuretics, low serum chloride concentration (sCl), and high PCV were associated with low uNa. Urine Na concentration outperformed other metrics of diuretic responsiveness including weight loss. Conclusions and Clinical Importance: Urine Na concentration after IV furosemide predicted timeO2 and cumulative frequency of DCSO2 in dogs with acute CHF, which likely reflects important aspects of diuretic responsiveness. Urine Na can assess diuretic responsiveness and treatment efficacy in dogs with CHF.
- 1 January 2024
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 38 (1) , 71-80
Open AccessUrine sodium concentration after intravenous furosemide in dogs with acute congestive heart failure and correlation with treatment efficacy
Background: Poor natriuresis is a potential marker of diuretic resistance in dogs with acute congestive heart failure (CHF) but little is known about the relationship between urine sodium concentration (uNa) and frequency of successful decongestion. Supplemental O2 is a common treatment in dogs with severe CHF. The time from start to discontinuation of supplemental O2 therapy (DCSO2) typically reflects the time course and ease of decongestion. Hypothesis/Objectives: Urine Na concentration after IV administration of furosemide will be correlated with duration of treatment with supplemental O2 (timeO2) and the cumulative frequency of successful DCSO2 during hospitalization. Animals: Fifty-one dogs with acute CHF. Methods: Retrospective observational single center study. Results: Dogs with low uNa had significantly longer mean timeO2 than dogs with high uNa (uNa <87 mmol/L, 24.2 ± 2.6 hours vs uNa ≥87 mmol/L, 16.6 ± 1.7 hours; P = .02). Low uNa was correlated with lower cumulative frequency of DCSO2 (12 hour, 28%; 24 hour, 42%; 36 hour, 73%) compared to high uNa (12 hour, 28%; 24 hour, 88%; 36 hour, 96%; P = .005). History of PO loop diuretics, low serum chloride concentration (sCl), and high PCV were associated with low uNa. Urine Na concentration outperformed other metrics of diuretic responsiveness including weight loss. Conclusions and Clinical Importance: Urine Na concentration after IV furosemide predicted timeO2 and cumulative frequency of DCSO2 in dogs with acute CHF, which likely reflects important aspects of diuretic responsiveness. Urine Na can assess diuretic responsiveness and treatment efficacy in dogs with CHF.
- Open Access
- 1 September 2019
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 33 (5) , 1892-1901
The use of focused cardiac ultrasound to screen for occult heart disease in asymptomatic cats
Background: Focused cardiac ultrasound (FCU) helps detect occult heart disease in human patients. Hypothesis: Focused cardiac ultrasound by a nonspecialist practitioner (NSP) will increase the detection of occult heart disease in asymptomatic cats compared with physical examination and ECG. Animals: Three hundred forty-three client-owned cats: 54 excluded and 289 analyzed. Methods: Multicenter prospective cohort study. Twenty-two NSPs were trained to perform FCU. Cats without clinical signs of heart disease were recruited, and NSPs performed the following in sequential order: physical examination, ECG, FCU, and point-of-care N-terminal pro-B-type natriuretic peptide assay (POC-BNP). After each step, NSPs indicated yes, no, or equivocal as to whether they believed heart disease was present. The level of agreement between the NSP diagnosis and a blinded cardiologist's diagnosis after echocardiogram was evaluated using Cohen's kappa test. Results: Cardiologist diagnoses included 148 normal cats, 102 with heart disease, and 39 equivocal ones. Agreement between NSP and cardiologist was slight after physical examination (kappa 0.253 [95% CI, 0.172-0.340]), did not increase after ECG (0.256 [0.161-0.345]; P = .96), increased after FCU (0.468 [0.376-0.558]; P = .002), and the level of agreement was similar after POC-BNP (0.498 [0.419-0.580]; P = .67). In cats with mild, moderate, and marked occult heart disease, the proportion of cats having a NSP diagnosis of heart disease after FCU was 45.6%, 93.1%, and 100%, respectively. Conclusions and Clinical Importance: Focused cardiac ultrasound performed by NSPs increased the detection of occult heart disease, especially in cats with moderate to marked disease. Focused cardiac ultrasound appears to be a feasible and useful tool to assist NSPs in the detection of heart disease in cats.
- 1 September 2019
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 33 (5) , 1892-1901
Open AccessThe use of focused cardiac ultrasound to screen for occult heart disease in asymptomatic cats
Background: Focused cardiac ultrasound (FCU) helps detect occult heart disease in human patients. Hypothesis: Focused cardiac ultrasound by a nonspecialist practitioner (NSP) will increase the detection of occult heart disease in asymptomatic cats compared with physical examination and ECG. Animals: Three hundred forty-three client-owned cats: 54 excluded and 289 analyzed. Methods: Multicenter prospective cohort study. Twenty-two NSPs were trained to perform FCU. Cats without clinical signs of heart disease were recruited, and NSPs performed the following in sequential order: physical examination, ECG, FCU, and point-of-care N-terminal pro-B-type natriuretic peptide assay (POC-BNP). After each step, NSPs indicated yes, no, or equivocal as to whether they believed heart disease was present. The level of agreement between the NSP diagnosis and a blinded cardiologist's diagnosis after echocardiogram was evaluated using Cohen's kappa test. Results: Cardiologist diagnoses included 148 normal cats, 102 with heart disease, and 39 equivocal ones. Agreement between NSP and cardiologist was slight after physical examination (kappa 0.253 [95% CI, 0.172-0.340]), did not increase after ECG (0.256 [0.161-0.345]; P = .96), increased after FCU (0.468 [0.376-0.558]; P = .002), and the level of agreement was similar after POC-BNP (0.498 [0.419-0.580]; P = .67). In cats with mild, moderate, and marked occult heart disease, the proportion of cats having a NSP diagnosis of heart disease after FCU was 45.6%, 93.1%, and 100%, respectively. Conclusions and Clinical Importance: Focused cardiac ultrasound performed by NSPs increased the detection of occult heart disease, especially in cats with moderate to marked disease. Focused cardiac ultrasound appears to be a feasible and useful tool to assist NSPs in the detection of heart disease in cats.
- Open Access
- 4 December 2017
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 32 (1) , 86-92
Retrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation
Background Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Hypothesis/Objectives Heart rate affects survival in dogs with chronic AF. Animals Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Methods Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR P < 0.001). Median survival time of dogs with meanHRP = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Conclusions and Clinical Importance Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm.
- 4 December 2017
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 32 (1) , 86-92
Open AccessRetrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation
Background Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Hypothesis/Objectives Heart rate affects survival in dogs with chronic AF. Animals Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Methods Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR P < 0.001). Median survival time of dogs with meanHRP = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Conclusions and Clinical Importance Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm.
- 1 May 2005
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 7 (1) , 59-64
Complete atrioventricular canal defect in a foal: Clinical and pathological features
- 1 May 2005
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 7 (1) , 59-64
Complete atrioventricular canal defect in a foal: Clinical and pathological features
- Open Access
- 1 September 1998
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 12 (5) , 355-364
Signal-Averaged Electrocardiograms in Normal Doberman Pinschers
Signal‐averaged electrocardiograms (SAECGs) were performed on nonsedated normal dogs in left‐lateral recumbency. Following signal averaging, both time‐domain and 3‐dimensional frequency‐domain analyses were performed. For time‐domain analysis, the high‐frequency QRS (HFQRS) duration, duration of the terminal QRS complex less than 40 μV (LAS40), and root mean square (RMS) voltages (μV) of the terminal 40 milliseconds (RMS40) and 30 milliseconds of the QRS complex were calculated. For frequency‐domain analysis, correlation ratios were calculated for 30‐, 40‐, 50‐, and 60‐millisecond segment lengths begun 10, 15, or 20 milliseconds before the end of the QRS complex. Spectro‐temporal mapping was also performed. All of the parameters of the SAECGs analyzed in the time domain were associated with each other. LAS40 and RMS voltages regressed significantly (P < .0000) on the HFQRS duration. Ninety‐five percent of the HFQRSs were 55–75 milliseconds, 95% of the LAS40 s were 9–26 milliseconds, and 95% of the RMS40 voltages were 177–444 μV. None of the SAECGs contained evidence of ventricular late potentials. Spectro‐temporal maps were similar in each dog when the same segment lengths and starting points were compared. No evidence of ventricular late potentials was observed. Correlation ratios were lower when windowed segments included 15 or 20 milliseconds (versus 10 milliseconds) of the terminal QRS complex. When only 10 milliseconds of the terminal QRS complex were included in windowed segments, the mean correlation ratios for 30‐and 40‐millisecond segment lengths were > 0.8 and > 0.61 in 67% of all analyses, respectively.
- 1 September 1998
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 12 (5) , 355-364
Open AccessSignal-Averaged Electrocardiograms in Normal Doberman Pinschers
Signal‐averaged electrocardiograms (SAECGs) were performed on nonsedated normal dogs in left‐lateral recumbency. Following signal averaging, both time‐domain and 3‐dimensional frequency‐domain analyses were performed. For time‐domain analysis, the high‐frequency QRS (HFQRS) duration, duration of the terminal QRS complex less than 40 μV (LAS40), and root mean square (RMS) voltages (μV) of the terminal 40 milliseconds (RMS40) and 30 milliseconds of the QRS complex were calculated. For frequency‐domain analysis, correlation ratios were calculated for 30‐, 40‐, 50‐, and 60‐millisecond segment lengths begun 10, 15, or 20 milliseconds before the end of the QRS complex. Spectro‐temporal mapping was also performed. All of the parameters of the SAECGs analyzed in the time domain were associated with each other. LAS40 and RMS voltages regressed significantly (P < .0000) on the HFQRS duration. Ninety‐five percent of the HFQRSs were 55–75 milliseconds, 95% of the LAS40 s were 9–26 milliseconds, and 95% of the RMS40 voltages were 177–444 μV. None of the SAECGs contained evidence of ventricular late potentials. Spectro‐temporal maps were similar in each dog when the same segment lengths and starting points were compared. No evidence of ventricular late potentials was observed. Correlation ratios were lower when windowed segments included 15 or 20 milliseconds (versus 10 milliseconds) of the terminal QRS complex. When only 10 milliseconds of the terminal QRS complex were included in windowed segments, the mean correlation ratios for 30‐and 40‐millisecond segment lengths were > 0.8 and > 0.61 in 67% of all analyses, respectively.