Thomas Pottier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Pottier has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
G. Germain
Arts et Metiers ParisTech, LAMPA, 2 bd du Ronceray, 49035 Angers Cedex, France
2 shared publicationsA. Morel
Arts et Métiers ParisTech, LAMPA-EA1427
1 shared publication- Abdelmagid El Bakali
Université Grenoble Alpes, CNRS, Grenoble INP, SIMAP, F-38402 Grenoble, France
1 shared publication - Bessam Zeramdini
LAMPA, Arts et Métiers
1 shared publication - Camille Robert
LAMPA, Arts et Métiers ParisTech at Angers, 2 Boulevard du Ronceray, BP 93525, F-49035 Angers cedex 01, France 49100 Angers
1 shared publication D. Coupard
Arts et Métiers ParisTech, I2M-UMR5295
1 shared publication
Latest Publications
- Open Access
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 115116
A fast and versatile method for spectral emissivity measurement at high temperatures
In this paper, the development of a new device for high temperature emissivity measurement is described. This device aims at measuring both spectral and total emissivity for a thermal range of 600–1000 °C. The main targeted properties of this device are versatility and simplicity. To achieve this, a rigorous selection of components such as heating systems, heat sources, sample holders, and measuring devices was made. Sample dimensions and the corresponding sample holder were optimized through a ray tracing model computation. Selection of sensors to compute the total emissivity was also discussed. A near-infrared (NIR) spectrometer and two mid-infrared (MIR) cameras equipped with optical filters covering the bandwidth of 3–5 and 7.5–13 μm were chosen for spectral measurements. The major impediment was the separation of the sample signal and various spurious signals emitted by the environment. A specific measurement methodology was then made for each bandwidth to resolve this issue. Platinum was chosen as the reference material for the device validation. Spectral emissivity measurements were then compared to values from a commercial spectrometer. A good agreement was found between NIR and MIR band I measurements, and a higher error rate was seen in MIR band II which is explained by a less favorable signal to noise ratio. Integrated emissivity is then calculated and compared to values found in the literature. A good agreement between these values is found, and similar trends with temperature are observed. The device is then validated for spectral and total emissivity measurements. Device versatility and simplicity allow for an easy adaptation to a large area of applications.
- 1 November 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 115116
Open AccessA fast and versatile method for spectral emissivity measurement at high temperatures
In this paper, the development of a new device for high temperature emissivity measurement is described. This device aims at measuring both spectral and total emissivity for a thermal range of 600–1000 °C. The main targeted properties of this device are versatility and simplicity. To achieve this, a rigorous selection of components such as heating systems, heat sources, sample holders, and measuring devices was made. Sample dimensions and the corresponding sample holder were optimized through a ray tracing model computation. Selection of sensors to compute the total emissivity was also discussed. A near-infrared (NIR) spectrometer and two mid-infrared (MIR) cameras equipped with optical filters covering the bandwidth of 3–5 and 7.5–13 μm were chosen for spectral measurements. The major impediment was the separation of the sample signal and various spurious signals emitted by the environment. A specific measurement methodology was then made for each bandwidth to resolve this issue. Platinum was chosen as the reference material for the device validation. Spectral emissivity measurements were then compared to values from a commercial spectrometer. A good agreement was found between NIR and MIR band I measurements, and a higher error rate was seen in MIR band II which is explained by a less favorable signal to noise ratio. Integrated emissivity is then calculated and compared to values found in the literature. A good agreement between these values is found, and similar trends with temperature are observed. The device is then validated for spectral and total emissivity measurements. Device versatility and simplicity allow for an easy adaptation to a large area of applications.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1769 (1) , 200018
Simulation of metal forming processes with a 3D adaptive remeshing procedure
In this paper, a fully adaptive 3D numerical methodology based on a tetrahedral element was proposed in order to improve the finite element simulation of any metal forming process. This automatic methodology was implemented in a computational platform which integrates a finite element solver, 3D mesh generation and a field transfer algorithm. The proposed remeshing method was developed in order to solve problems associated with the severe distortion of elements subject to large deformations, to concentrate the elements where the error is large and to coarsen the mesh where the error is small. This leads to a significant reduction in the computation times while maintaining simulation accuracy. In addition, in order to enhance the contact conditions, this method has been coupled with a specific operator to maintain the initial contact between the workpiece nodes and the rigid tool after each remeshing step. In this paper special attention is paid to the data transfer methods and the necessary adaptive remeshing steps are given. Finally, a numerical example is detailed to demonstrate the efficiency of the approach and to compare the results for the different field transfer strategies.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1769 (1) , 200018
Simulation of metal forming processes with a 3D adaptive remeshing procedure
In this paper, a fully adaptive 3D numerical methodology based on a tetrahedral element was proposed in order to improve the finite element simulation of any metal forming process. This automatic methodology was implemented in a computational platform which integrates a finite element solver, 3D mesh generation and a field transfer algorithm. The proposed remeshing method was developed in order to solve problems associated with the severe distortion of elements subject to large deformations, to concentrate the elements where the error is large and to coarsen the mesh where the error is small. This leads to a significant reduction in the computation times while maintaining simulation accuracy. In addition, in order to enhance the contact conditions, this method has been coupled with a specific operator to maintain the initial contact between the workpiece nodes and the rigid tool after each remeshing step. In this paper special attention is paid to the data transfer methods and the necessary adaptive remeshing steps are given. Finally, a numerical example is detailed to demonstrate the efficiency of the approach and to compare the results for the different field transfer strategies.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1769 (1) , 080015
A new behavior model for better understanding of titanium alloys Ti-6Al-4V chip formation in orthogonal cutting
The behavior of Ti-6Al-4V has been studied via shear tests, using hat shaped specimen, on a servo-hydraulic Gleeble 3800 testing machine under the strain rate up to 103s−1and temperature up to 900°C. A new thermo-visco-plastic material law is proposed, based on a modified Johnson-Cook formulation. An inverse identification method based on Finite Element (FE) is established and detailed in order to determine the constitutive law’s parameters. The new model is implemented in a 3D finite element model to study the chip formation in orthogonal cutting configuration. The numerical simulations were performed on FE software Impetus Afea® able to solve dynamic non-linear problem.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1769 (1) , 080015
A new behavior model for better understanding of titanium alloys Ti-6Al-4V chip formation in orthogonal cutting
The behavior of Ti-6Al-4V has been studied via shear tests, using hat shaped specimen, on a servo-hydraulic Gleeble 3800 testing machine under the strain rate up to 103s−1and temperature up to 900°C. A new thermo-visco-plastic material law is proposed, based on a modified Johnson-Cook formulation. An inverse identification method based on Finite Element (FE) is established and detailed in order to determine the constitutive law’s parameters. The new model is implemented in a 3D finite element model to study the chip formation in orthogonal cutting configuration. The numerical simulations were performed on FE software Impetus Afea® able to solve dynamic non-linear problem.
- 4 April 2014
- Published by Springer Nature in Experimental Mechanics
- Vol. 54 (6) , 1031-1042
Sub-Millimeter Measurement of Finite Strains at Cutting Tool Tip Vicinity
- 4 April 2014
- Published by Springer Nature in Experimental Mechanics
- Vol. 54 (6) , 1031-1042
Sub-Millimeter Measurement of Finite Strains at Cutting Tool Tip Vicinity