Arivarasan Ilamurugu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arivarasan Ilamurugu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Anantharaman Ayyalusamy
Department of Radiation Oncology, Yashoda Hospitals, Hyderabad, India
2 shared publications Shanmuga Subramanian
Department of Radiation Oncology, Yashoda Hospitals, Hyderabad, India
2 shared publicationsA. Ayyalusamy
Department of Radiation Oncology, Yashoda Hospitals, Hyderabad, India
1 shared publicationA. Chandrasekaran
School of Advanced Sciences, Vellore Institute of Technology, Vellore, India
1 shared publicationAnantharaman Ayyalusamy
Department of Radiation Oncology, Yashoda Cancer Institute, Yashoda Hospitals, Nalgonda X Roads, Hyderabad, 500036, India
1 shared publicationAneesha Madineni
Department of Radiation Oncology, Yashoda Hospitals, Hyderabad, India
1 shared publication
Latest Publications
- 1 April 2021
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 25 (2) , 135-140
Volumetric and dosimetric impact of MRI in delineation of gross tumor volume of non-spinal vertebral metastases treated with stereotactic ablative radiation therapy
- 1 April 2021
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 25 (2) , 135-140
Volumetric and dosimetric impact of MRI in delineation of gross tumor volume of non-spinal vertebral metastases treated with stereotactic ablative radiation therapy
- Open Access
- 1 January 2021
- Published by Medknow in Journal of Cancer Research and Therapeutics
Challenges and developments of magnetic resonance image-guided radiation therapy for brain tumors
Treatment of brain lesions with magnetic resonance imaging (MRI) is indispensable. Although computed tomography (CT) is the gold standard for radiotherapy (RT) planning, recent developments in image-guided RT have compelling reasons to remove CT from the regular RT workflow. Thus, magnetic resonance (MR) only RT is gaining interest rapidly. In this review, we look at how MRI has gained the importance in radiation planning at various stages and why we try to refrain CT imaging. We have elaborated the MR simulation techniques for the brain from different expertise to get a clear insight about the imaging protocols and quality assurance steps tweaked for RT requirements. We have described the basic and complex algorithms utilized to promulgate a CT-like data set from appropriate MR sequences for crucial treatment planning process. In a small section, we have narrated the significance of dose escalation using the functional MR images. In the final section, we describe a pivotal (yet least researched) area of digital radiograph generation using MR dataset for day-to-day pretreatment image verification on couch.
- 1 January 2021
- Published by Medknow in Journal of Cancer Research and Therapeutics
Open AccessChallenges and developments of magnetic resonance image-guided radiation therapy for brain tumors
Treatment of brain lesions with magnetic resonance imaging (MRI) is indispensable. Although computed tomography (CT) is the gold standard for radiotherapy (RT) planning, recent developments in image-guided RT have compelling reasons to remove CT from the regular RT workflow. Thus, magnetic resonance (MR) only RT is gaining interest rapidly. In this review, we look at how MRI has gained the importance in radiation planning at various stages and why we try to refrain CT imaging. We have elaborated the MR simulation techniques for the brain from different expertise to get a clear insight about the imaging protocols and quality assurance steps tweaked for RT requirements. We have described the basic and complex algorithms utilized to promulgate a CT-like data set from appropriate MR sequences for crucial treatment planning process. In a small section, we have narrated the significance of dose escalation using the functional MR images. In the final section, we describe a pivotal (yet least researched) area of digital radiograph generation using MR dataset for day-to-day pretreatment image verification on couch.
- Open Access
- 30 June 2019
- Published by Korean Society for Therapeutic Radiology and Oncology in Radiation Oncology Journal
- Vol. 37 (2) , 134-142
Auto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity
The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.
- 30 June 2019
- Published by Korean Society for Therapeutic Radiology and Oncology in Radiation Oncology Journal
- Vol. 37 (2) , 134-142
Open AccessAuto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity
The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.
- 19 December 2018
- Published by Springer Nature in La radiologia medica
- Vol. 124 (5) , 400-407
Feasibility of MR-only radiation planning for hypofractionated stereotactic radiotherapy of schwannomas using non-coplanar volumetric modulated arc therapy
To compare the dose calculation accuracy of plans done on a CT density-assigned MR image set for hypofractionated stereotactic radiotherapy (HSRT) using volumetric modulated radiation therapy containing non-coplanar beams.
- 19 December 2018
- Published by Springer Nature in La radiologia medica
- Vol. 124 (5) , 400-407
Feasibility of MR-only radiation planning for hypofractionated stereotactic radiotherapy of schwannomas using non-coplanar volumetric modulated arc therapy
To compare the dose calculation accuracy of plans done on a CT density-assigned MR image set for hypofractionated stereotactic radiotherapy (HSRT) using volumetric modulated radiation therapy containing non-coplanar beams.
- 13 June 2017
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 35 (8) , 417-426
Magnetic resonance image guidance in external beam radiation therapy planning and delivery
The use of magnetic resonance (MR) imaging in radiation oncology is improving dramatically. This review article discusses the necessity of image guidance and how MR finds a significant place in radiotherapy planning and delivery. The challenges to and current solutions for an in-house MR simulation, dedicated MR simulator, estimation of electron density using MR image sets and development of MR-compatible treatment planning systems are presented. This article also reviews the feasibility, advantages and limitations of MR image-guided radiation therapy (MR-IGRT) and its drive toward the integration of radiation beams with MR technology. Specifications of Co-60 MR technology and three other MR-linac projects worldwide are presented. Online and real-time MR guidance is also discussed.
- 13 June 2017
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 35 (8) , 417-426
Magnetic resonance image guidance in external beam radiation therapy planning and delivery
The use of magnetic resonance (MR) imaging in radiation oncology is improving dramatically. This review article discusses the necessity of image guidance and how MR finds a significant place in radiotherapy planning and delivery. The challenges to and current solutions for an in-house MR simulation, dedicated MR simulator, estimation of electron density using MR image sets and development of MR-compatible treatment planning systems are presented. This article also reviews the feasibility, advantages and limitations of MR image-guided radiation therapy (MR-IGRT) and its drive toward the integration of radiation beams with MR technology. Specifications of Co-60 MR technology and three other MR-linac projects worldwide are presented. Online and real-time MR guidance is also discussed.
- 1 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1069) , 20160420
Feasibility of offline head & neck adaptive radiotherapy using deformed planning CT electron density mapping on weekly cone beam computed tomography
The purpose of the study was to use deformable mapping of planning CT (pCT) electron density values on weekly cone-beam CT (CBCT) to quantify the anatomical changes and determine the dose–volume relationship in offline adaptive volumetric-modulated arc therapy. 10 patients treated with RapidArc plans who had weekly CBCTs were selected retrospectively. The pCT was deformed to weekly CBCTs and the deformed contours were checked for any discrepancies. Clinical target volume 66 Gy and 60 Gy (CTV66 and CTV60), parotids and spinal cord were the structures selected for analysis. Volume reduction and dice similarity index (DSI) were determined. Hybrid RapidArc plans were created and the cumulative dose–volume histograms for selected structures were analyzed. Results showed a mean volume reduction of 18.82 ± 6.08% and 18.22 ± 6.1% for Clinical target volume 66 Gy and 60 Gy (CTV66 and CTV60), respectively, and their corresponding DSI values were 0.94 ± 0.03 and 0.95 ± 0.01. Mean volume reductions of left and right parotids were 32.79 ± 10.28% and 29.46 ± 8.78%, respectively, and their corresponding mean DSI values were 0.90 ± 0.05 and 0.89 ± 0.05. The cumulative mean dose difference for Planning target volume 66 Gy (PTV66) was −1.35 ± 1.71% and for Planning target volume 60 Gy (PTV60), it was −0.69 ± 1.37%. Spinal cord doses varied for all patients over the course. The results from the study showed that it is clinically feasible to estimate the dose–volume relationship using deformed pCT. Monitoring of patient anatomic changes and incorporating patient-specific replanning strategy are necessary to avoid critical structure complications. Deformable mapping of pCT electron density values on weekly CBCTs has been performed to establish the volumetric and dosimetric changes. The anatomical changes differ among the patients and hence, the choice for adaptive radiotherapy should be strictly patient specific rather than time specific.
- 1 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1069) , 20160420
Feasibility of offline head & neck adaptive radiotherapy using deformed planning CT electron density mapping on weekly cone beam computed tomography
The purpose of the study was to use deformable mapping of planning CT (pCT) electron density values on weekly cone-beam CT (CBCT) to quantify the anatomical changes and determine the dose–volume relationship in offline adaptive volumetric-modulated arc therapy. 10 patients treated with RapidArc plans who had weekly CBCTs were selected retrospectively. The pCT was deformed to weekly CBCTs and the deformed contours were checked for any discrepancies. Clinical target volume 66 Gy and 60 Gy (CTV66 and CTV60), parotids and spinal cord were the structures selected for analysis. Volume reduction and dice similarity index (DSI) were determined. Hybrid RapidArc plans were created and the cumulative dose–volume histograms for selected structures were analyzed. Results showed a mean volume reduction of 18.82 ± 6.08% and 18.22 ± 6.1% for Clinical target volume 66 Gy and 60 Gy (CTV66 and CTV60), respectively, and their corresponding DSI values were 0.94 ± 0.03 and 0.95 ± 0.01. Mean volume reductions of left and right parotids were 32.79 ± 10.28% and 29.46 ± 8.78%, respectively, and their corresponding mean DSI values were 0.90 ± 0.05 and 0.89 ± 0.05. The cumulative mean dose difference for Planning target volume 66 Gy (PTV66) was −1.35 ± 1.71% and for Planning target volume 60 Gy (PTV60), it was −0.69 ± 1.37%. Spinal cord doses varied for all patients over the course. The results from the study showed that it is clinically feasible to estimate the dose–volume relationship using deformed pCT. Monitoring of patient anatomic changes and incorporating patient-specific replanning strategy are necessary to avoid critical structure complications. Deformable mapping of pCT electron density values on weekly CBCTs has been performed to establish the volumetric and dosimetric changes. The anatomical changes differ among the patients and hence, the choice for adaptive radiotherapy should be strictly patient specific rather than time specific.