André Carvalho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
André Carvalho has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Afzal Suleman
Department of Mechanical Engineering, University of Victoria, Victoria, BC V8P 5C2, Canada
4 shared publications - Diogo Montalvão
Bournemouth University
4 shared publications - Luis Reis
University of Lisbon Lisbon Portugal
4 shared publications - Manuel Fonte
IDMEC, Escola Náutica Infante D. Henrique in Paço de Arcos, Portugal
3 shared publications - Curran Crawford
Institute for Integrated Energy Systems, University of Victoria, Victoria, Canada
2 shared publications - Joaquim Infante Barbosa
CIMOSM, ISEL—Centro de Investigação em Modelação e Optimização de Sistemas Multifuncionais, Instituto Superior de Engenharia de Lisboa, 1959-007 Lisboa, Portugal
2 shared publications
Latest Publications
- Open Access
Study of Damping of Bare and Encased Steel I-Beams Using the Thermoelastic Model
Steel I-beams are a fundamental structural component in civil construction. They are one of the main load-bearing components in a building that must withstand both the structure and any incoming external perturbations, such as seismic events. To avoid damage to the structure, the building must be designed to dissipate the maximum amount of energy possible. One way energy can be dissipated is through internal or structural damping, of which thermoelasticity is one of the causes, especially in low-frequency harmonic excitations. The main goal of this study is to analyze the amount of damping in an I-beam generated by thermoelasticity and when encased in a Portland cement concrete layer, using a Finite Element model. It was found that, due to the geometry of the I-Beam, the damping coefficient as a function of frequency has two local maxima, as opposed to the traditional single maximum in rectangular beams. Encasing an I-beam in a concrete layer decreases the overall damping. While the extra coating protects the beam, the reduction in damping leads to a lower energy dissipation rate and higher vibration amplitudes.
Open AccessStudy of Damping of Bare and Encased Steel I-Beams Using the Thermoelastic Model
Steel I-beams are a fundamental structural component in civil construction. They are one of the main load-bearing components in a building that must withstand both the structure and any incoming external perturbations, such as seismic events. To avoid damage to the structure, the building must be designed to dissipate the maximum amount of energy possible. One way energy can be dissipated is through internal or structural damping, of which thermoelasticity is one of the causes, especially in low-frequency harmonic excitations. The main goal of this study is to analyze the amount of damping in an I-beam generated by thermoelasticity and when encased in a Portland cement concrete layer, using a Finite Element model. It was found that, due to the geometry of the I-Beam, the damping coefficient as a function of frequency has two local maxima, as opposed to the traditional single maximum in rectangular beams. Encasing an I-beam in a concrete layer decreases the overall damping. While the extra coating protects the beam, the reduction in damping leads to a lower energy dissipation rate and higher vibration amplitudes.
- Open Access
- 27 June 2019
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 13 (49) , 450-462
Characterisation and Evaluation of the Mechanical Behaviour of Endodontic-grade NiTi Wires
With the introduction of new materials and advances in medical science, the endodontic files have changed since the early days of root canal treatments. In the late days, we have seen an increasing use of Nickel-Titanium (NiTi) alloys, to the detriment of more conventional alloys. At body temperature, NiTi alloys present a superelastic behaviour, which allows to be more effective in the removal of the tooth pulp tissue, and in the protection of the tooth structure. Anyhow, these NiTi instruments will eventually fracture, usually without any visual signal of degradation. Thus, there is a need of studying these alloys, as they present a high hysteresis cycle and non-linearities in the Elastic domain. Currently, there is no international standard to test NiTi endodontic files, so various authors have attempted to design systems that can test them under fatigue loads, usually based on empirical setups. Following a systematic approach, this work presents the results of rotary fatigue tests for two Alfa Aesar® Nitinol wires with different diameters (0.58mm and 0.25mm).The formulation is presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure, as well numerical FEM simulation to verify the analytical model predictions.
- 27 June 2019
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 13 (49) , 450-462
Open AccessCharacterisation and Evaluation of the Mechanical Behaviour of Endodontic-grade NiTi Wires
With the introduction of new materials and advances in medical science, the endodontic files have changed since the early days of root canal treatments. In the late days, we have seen an increasing use of Nickel-Titanium (NiTi) alloys, to the detriment of more conventional alloys. At body temperature, NiTi alloys present a superelastic behaviour, which allows to be more effective in the removal of the tooth pulp tissue, and in the protection of the tooth structure. Anyhow, these NiTi instruments will eventually fracture, usually without any visual signal of degradation. Thus, there is a need of studying these alloys, as they present a high hysteresis cycle and non-linearities in the Elastic domain. Currently, there is no international standard to test NiTi endodontic files, so various authors have attempted to design systems that can test them under fatigue loads, usually based on empirical setups. Following a systematic approach, this work presents the results of rotary fatigue tests for two Alfa Aesar® Nitinol wires with different diameters (0.58mm and 0.25mm).The formulation is presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure, as well numerical FEM simulation to verify the analytical model predictions.
- 13 October 2017
- Published by Springer Nature
- p. 275-285
Developments on Finite Element Methods for Medical Image Supported Diagnostics
- 13 October 2017
- Published by Springer Nature
- p. 275-285
Developments on Finite Element Methods for Medical Image Supported Diagnostics
- 13 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (15) , 4791-4796
Structural Health Monitoring Suitable for Airborne Components Using the Speckle Pattern in Plastic Optical Fibers
Structural health monitoring (SHM) is a key factor for the correct operation in large dimension structures. In this paper, we propose and demonstrate the application of a distributed optical sensor, suitable for SHM, based on the evaluation of the speckle pattern at the output of a polymer optical fibers, aiming to evaluate the damage imposed to airborne metallic and composite structures. We propose also several algorithms to analyze the speckle data and access the imposed mechanical perturbation. The maximum sampling frequency of this method is limited by the image acquisition devices, yielding to a value of 15 Hz in our case.
- 13 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (15) , 4791-4796
Structural Health Monitoring Suitable for Airborne Components Using the Speckle Pattern in Plastic Optical Fibers
Structural health monitoring (SHM) is a key factor for the correct operation in large dimension structures. In this paper, we propose and demonstrate the application of a distributed optical sensor, suitable for SHM, based on the evaluation of the speckle pattern at the output of a polymer optical fibers, aiming to evaluate the damage imposed to airborne metallic and composite structures. We propose also several algorithms to analyze the speckle data and access the imposed mechanical perturbation. The maximum sampling frequency of this method is limited by the image acquisition devices, yielding to a value of 15 Hz in our case.
- 1 October 2016
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 85, 37-44
Determination of the rotary fatigue life of NiTi alloy wires
- 1 October 2016
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 85, 37-44
Determination of the rotary fatigue life of NiTi alloy wires
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Structural Integrity
- Vol. 1, 34-41
Rotary Fatigue Testing to Determine the Fatigue Life of NiTi alloy Wires: An Experimental and Numerical Analisys
- 1 January 2016
- Published by Elsevier in Procedia Structural Integrity
- Vol. 1, 34-41
Open AccessRotary Fatigue Testing to Determine the Fatigue Life of NiTi alloy Wires: An Experimental and Numerical Analisys
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 114, 500-505
Rotary Fatigue Testing Machine to Determine the Fatigue Life of NiTi alloy Wires and Endondontic Files
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 114, 500-505
Open AccessRotary Fatigue Testing Machine to Determine the Fatigue Life of NiTi alloy Wires and Endondontic Files
- 27 July 2012
- Published by Springer Nature in Multibody System Dynamics
- Vol. 29 (3) , 271-288
Multibody simulation of the musculoskeletal system of the human hand
- 27 July 2012
- Published by Springer Nature in Multibody System Dynamics
- Vol. 29 (3) , 271-288
Multibody simulation of the musculoskeletal system of the human hand