Mark Ballico
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mark Ballico has a total of 398 co-authors. Here are the top co-authors by number of shared publications:
- Eric Wilhelmus Maria van der Ham
National Measurement Institute
7 shared publications - Rod Cross
University of Sydney, Abbotsford, NSW, Australia
6 shared publications - Dolores del Campo
Centro Español de Metrología, Alfar 2, 28760 Tres Cantos, Spain
4 shared publications - Ferdouse Jahan
National Measurement Institute, Australia (NMIA)
4 shared publications Jafar Madadnia
University of Technology, Sydney
4 shared publications- Naohiko Sasajima
National Metrology Institute of Japan, AIST
3 shared publications
Latest Publications
- 24 November 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (1) , 14
Measurement of the Nonlinearity of Heat-Flux Sensors Employing a $\hbox {CO}_2$ CO 2 laser- 24 November 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (1) , 14
Measurement of the Nonlinearity of Heat-Flux Sensors Employing a $\hbox {CO}_2$ CO 2 laser- 25 May 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 390-398
The equilibrium liquidus temperatures of rhenium–carbon, platinum–carbon and cobalt–carbon eutectic alloys
The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91 ± 0.44 K, for platinum–carbon 2011.50 ± 0.22 K and for cobalt–carbon 1597.48 ± 0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).
- 25 May 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 390-398
The equilibrium liquidus temperatures of rhenium–carbon, platinum–carbon and cobalt–carbon eutectic alloys
The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91 ± 0.44 K, for platinum–carbon 2011.50 ± 0.22 K and for cobalt–carbon 1597.48 ± 0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).
- 17 March 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (5) , 73
Design and Investigation of Pd–C Eutectic Fixed-Point Cells for Thermocouple Calibration at NMIA
- 17 March 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (5) , 73
Design and Investigation of Pd–C Eutectic Fixed-Point Cells for Thermocouple Calibration at NMIA
- Open Access
- 28 March 2016
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 374 (2064) , 20150044
Thermodynamic temperature assignment to the point of inflection of the melting curve of high-temperature fixed points
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.
- 28 March 2016
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 374 (2064) , 20150044
Open AccessThermodynamic temperature assignment to the point of inflection of the melting curve of high-temperature fixed points
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.
- 22 October 2015
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 26 (12) , 125201
Aperture area measurement using two different traceability routes
Given the advances in cryogenic radiometry, area measurement is now one of the limiting factors in the realisation of radiometric and photometric units as well as radiometric temperature scales. An inter-comparison of aperture area measurements using complementary methods at two different national metrology institutes has shown excellent agreement in the values measured, with the measurements agreeing well within the 95% confidence intervals. Importantly, the statistical scatter of the values is consistent with the magnitude of the confidence intervals, implying that the estimates of uncertainty are not overly conservative. This provides increased confidence to both institutes that systematic errors have not been overlooked and that the uncertainty contributions have been realistically assessed.
- 22 October 2015
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 26 (12) , 125201
Aperture area measurement using two different traceability routes
Given the advances in cryogenic radiometry, area measurement is now one of the limiting factors in the realisation of radiometric and photometric units as well as radiometric temperature scales. An inter-comparison of aperture area measurements using complementary methods at two different national metrology institutes has shown excellent agreement in the values measured, with the measurements agreeing well within the 95% confidence intervals. Importantly, the statistical scatter of the values is consistent with the magnitude of the confidence intervals, implying that the estimates of uncertainty are not overly conservative. This provides increased confidence to both institutes that systematic errors have not been overlooked and that the uncertainty contributions have been realistically assessed.
- 12 May 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1848-1858
Laser-Induced Melting of Co-C Eutectic Cells as a New Research Tool
- 12 May 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1848-1858
Laser-Induced Melting of Co-C Eutectic Cells as a New Research Tool
- 1 July 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6-7) , 1067-1076
Temperature Dependence of IPRT and SPRT Self-Heating: Does Working with ${{\varvec{W}}}$ W Really Help?- 1 July 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6-7) , 1067-1076
Temperature Dependence of IPRT and SPRT Self-Heating: Does Working with ${{\varvec{W}}}$ W Really Help?- 27 June 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6) , 1310-1319
Handheld Reflective Foil Emissometer with 0.007 Absolute Accuracy at 0.05
- 27 June 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6) , 1310-1319
Handheld Reflective Foil Emissometer with 0.007 Absolute Accuracy at 0.05
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 740-745
A simple method for the measurement of reflective foil emissivity
Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 740-745
A simple method for the measurement of reflective foil emissivity
Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 544-548
Analysis of inhomogeneity in Au/Pt thermocouples to allow intercomparisons at better than 10 millikelvins
In a previous supplementary comparison of Au/Pt thermocouples, APMP.T-S4, it was demonstrated that these artifacts could successfully determine the equivalence of national scales within 40 mK at the Ag point (961.78 °C). However, the uncertainty arising from the measured inhomogeneity of the thermocouples was one of the dominant uncertainty components. To reduce this uncertainty, in the recent comparison APMP.T-S5, piloted by NMIA, the six participating NMIs were asked to provide more detailed data on the temperature profiles of the fixed point furnaces. This data was convolved with the measured thermocouple inhomogeneity to estimate the systematic error in the temperature difference measured between participants. The revised analysis allowed the calculated effect of a ± 0.004% inhomogeneity to be reduced from ± 0.004% of the thermocouple signal to below ± 0.0015%, and allowed Au/Pt thermocouples to determine inter-laboratory temperature differences to better than 16 mK (k = 2) at the Ag point.
- 1 January 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 544-548
Analysis of inhomogeneity in Au/Pt thermocouples to allow intercomparisons at better than 10 millikelvins
In a previous supplementary comparison of Au/Pt thermocouples, APMP.T-S4, it was demonstrated that these artifacts could successfully determine the equivalence of national scales within 40 mK at the Ag point (961.78 °C). However, the uncertainty arising from the measured inhomogeneity of the thermocouples was one of the dominant uncertainty components. To reduce this uncertainty, in the recent comparison APMP.T-S5, piloted by NMIA, the six participating NMIs were asked to provide more detailed data on the temperature profiles of the fixed point furnaces. This data was convolved with the measured thermocouple inhomogeneity to estimate the systematic error in the temperature difference measured between participants. The revised analysis allowed the calculated effect of a ± 0.004% inhomogeneity to be reduced from ± 0.004% of the thermocouple signal to below ± 0.0015%, and allowed Au/Pt thermocouples to determine inter-laboratory temperature differences to better than 16 mK (k = 2) at the Ag point.