GKGavriel David Kohlberg

Gavriel David Kohlberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gavriel David Kohlberg has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Anil K. Lalwani

    Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York-Presbyterian/Columbia University Irving Medical Center, New York, New York, USA

    5 shared publications
  • Dean M. Mancuso

    Department of Otolaryngology—Head and Neck Surgery, Columbia University Cochlear Implant Center, New York, New York

    4 shared publications
  • Jaclyn B. Spitzer

    Department of Otolaryngology—Head and Neck Surgery, Columbia University Cochlear Implant Center, New York, New York

    3 shared publications
  • Brianna M. Griffin

    Columbia University College of Physicians and Surgeons

    2 shared publications
  • Divya A. Chari

    Columbia University Cochlear Implant Center, Department of Otolaryngology/Head and Neck Surgery, Columbia University College of Physicians and Surgeons, 180 Fort Washington Avenue, Harkness Pavilion 8th Floor, New York, NY 10032, USA

    2 shared publications
  • Michael V. Certo

    Columbia University College of Physicians and Surgeons

    2 shared publications

Latest Publications

  • Open Access

    Wireless Hearables With Programmable Speech AI Accelerators

    by Malek Itani, Tuochao Chen, Arun Raghavan, Gavriel Kohlberg, Shyamnath Gollakota


  • Early and Late Recurrent Epistaxis Admissions: Patterns of Incidence and Risk Factors

    by Oded Cohen, Hagit Shoffel‐Havakuk, Meir Warman, Sharon Tzelnick, Yaara Haimovich, Gavriel D. Kohlberg, Doron Halperin, Yonatan Lahav

    Epistaxis is a common complaint, yet few studies have focused on the incidence and risk factors of recurrent epistaxis. Our objective was to determine the patterns of incidence and risk factors for recurrent epistaxis admission (REA). Case series with chart review. Single academic center. The medical records of patients admitted for epistaxis between 1999 and 2015 were reviewed. The follow-up period was defined as 3 years following initial admission. REAs were categorized as early (30 days) and late (31 days to 3 years) following initial admission. Logistic regression was used to identify potential predictors of REAs. A total of 653 patients were included. Eighty-six patients (14%) had REAs: 48 (7.5%) early and 38 (6.5%) late. Nonlinear incidence curve was demonstrated for both early and late REAs. Based on logistic regression, prior nasal surgery and anemia were independent risk factors for early REAs. According to multivariate analysis, thrombocytopenia was significantly associated with late REAs. Early and late REAs demonstrate different risk predictors. Knowledge of such risk factors may help in risk stratification for this selected group of patients. All patients at risk should be advised on possible preventive measures. Patients at risk for early REA may benefit from a more proactive approach.


  • Reduction of the Harmonic Series Influences Musical Enjoyment With Cochlear Implants

    by John S. Nemer, Gavriel D. Kohlberg, Dean M. Mancuso, Brianna M. Griffin, Michael V. Certo, Stephanie Y. Chen, Michael B. Chun, Jaclyn B. Spitzer, Anil K. Lalwani

    Objective: Cochlear implantation is associated with poor music perception and enjoyment. Reducing music complexity has been shown to enhance music enjoyment in cochlear implant (CI) recipients. In this study, we assess the impact of harmonic series reduction on music enjoyment. Study Design: Prospective analysis of music enjoyment in normal-hearing (NH) individuals and CI recipients. Setting: Single tertiary academic medical center. Patients: NH adults (N = 20) and CI users (N = 8) rated the Happy Birthday song on three validated enjoyment modalities—musicality, pleasantness, and naturalness. Intervention: Subjective rating of music excerpts. Main Outcome Measures: Participants listened to seven different instruments play the melody, each with five levels of harmonic reduction (Full, F3+F2+F1+F0, F2+F1+F0, F1+F0, F0). NH participants listened to the segments both with and without CI simulation. Linear mixed effect models (LME) and likelihood ratio tests were used to assess the impact of harmonic reduction on enjoyment. Results: NH listeners without simulation rated segments with the first four harmonics (F3+F2+F1+F0) most pleasant and natural (p p = 0.004). NH listeners with simulation rated the first harmonic alone (F0) most pleasant and natural (p p = 0.003). Their ratings demonstrated a positive linear relationship between harmonic reduction and both pleasantness (slope estimate = 0.030, SE = 0.004, p p = 0.003, LME). CI recipients also found the first harmonic alone (F0) to be most pleasant (p = 0.003), with a positive linear relationship between harmonic reduction and pleasantness (slope estimate = 0.029, SE = 0.008, p <0.001, LME). Conclusion: Harmonic series reduction increases music enjoyment in CI and NH individuals with or without CI simulation. Therefore, minimization of the harmonics may be a useful strategy for enhancing musical enjoyment among both NH and CI listeners.


  • Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy

    by Mark M Hammer, Gavriel D Kohlberg

    Background Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. Methods In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Results Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0–38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%–63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. Conclusion GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources.


  • Development of a Low-Cost, Noninvasive, Portable Visual Speech Recognition Program

    by Gavriel D. Kohlberg, Ya’AKov (Kobi) Gal, Anil K. Lalwani

    Objectives: Loss of speech following tracheostomy and laryngectomy severely limits communication to simple gestures and facial expressions that are largely ineffective. To facilitate communication in these patients, we seek to develop a low-cost, noninvasive, portable, and simple visual speech recognition program (VSRP) to convert articulatory facial movements into speech. Methods: A Microsoft Kinect–based VSRP was developed to capture spatial coordinates of lip movements and translate them into speech. The articulatory speech movements associated with 12 sentences were used to train an artificial neural network classifier. The accuracy of the classifier was then evaluated on a separate, previously unseen set of articulatory speech movements. Results: The VSRP was successfully implemented and tested in 5 subjects. It achieved an accuracy rate of 77.2% (65.0%-87.6% for the 5 speakers) on a 12-sentence data set. The mean time to classify an individual sentence was 2.03 milliseconds (1.91-2.16). Conclusion: We have demonstrated the feasibility of a low-cost, noninvasive, portable VSRP based on Kinect to accurately predict speech from articulation movements in clinically trivial time. This VSRP could be used as a novel communication device for aphonic patients.


  • Evaluation and Management of Pediatric Nasal Obstruction: A Survey of Practice Patterns

    by Gavriel D. Kohlberg, Michael G. Stewart, Robert F. Ward, Max M. April

    Background: Inferior turbinate (IT) hypertrophy and adenoid hypertrophy are both causes of pediatric nasal obstruction. Objective: The purpose of this survey was to study nasal obstruction evaluation and management among pediatric otolaryngologists with respect to IT and adenoid hypertrophy. Methods: A questionnaire with embedded clinical videos was sent electronically to American Society of Pediatric Otolaryngology members. Results: A total of 435 questionnaires were sent, and 75 were completed. Respondents were presented with scenarios that involved a 7-year-old child with nasal obstruction unresponsive to medical therapy, and the respondents were asked to choose a surgical plan, either IT reduction, adenoidectomy, or combined IT reduction and adenoidectomy. Three questions described the extent of IT and adenoid obstruction in text form, although three questions included a video of the child's nasal endoscopy. In questions with perceived or stated IT hypertrophy, the respondents chose to perform IT reduction significantly more frequently when the perceived or stated adenoid hypertrophy was less severe (p < 0.0001 for video and p = 0.039 for written questions). Conclusion: The decision to perform IT reduction in children is inversely related to the extent of adenoid hypertrophy. Future studies on pediatric IT surgery should include objective descriptions of the IT and adenoid in study subjects.


  • Impact of Noise Reduction Algorithm in Cochlear Implant Processing on Music Enjoyment

    by Gavriel D. Kohlberg, Dean M. Mancuso, Brianna M. Griffin, Jaclyn B. Spitzer, Anil K. Lalwani

    Noise reduction algorithm (NRA) in speech processing strategy has positive impact on speech perception among cochlear implant (CI) listeners. We sought to evaluate the effect of NRA on music enjoyment. Prospective analysis of music enjoyment. Academic medical center. Normal-hearing (NH) adults (N = 16) and CI listeners (N = 9). Subjective rating of music excerpts. NH and CI listeners evaluated country music piece on three enjoyment modalities: pleasantness, musicality, and naturalness. Participants listened to the original version and 20 modified, less complex versions created by including subsets of musical instruments from the original song. NH participants listened to the segments through CI simulation and CI listeners listened to the segments with their usual speech processing strategy, with and without NRA. Decreasing the number of instruments was significantly associated with increase in the pleasantness and naturalness in both NH and CI subjects (p < 0.05). However, there was no difference in music enjoyment with or without NRA for either NH listeners with CI simulation or CI listeners across all three modalities of pleasantness, musicality, and naturalness (p > 0.05): this was true for the original and the modified music segments with one to three instruments (p > 0.05). NRA does not affect music enjoyment in CI listener or NH individual with CI simulation. This suggests that strategies to enhance speech processing will not necessarily have a positive impact on music enjoyment. However, reducing the complexity of music shows promise in enhancing music enjoyment and should be further explored.


  • Open Access

    Music Engineering as a Novel Strategy for Enhancing Music Enjoyment in the Cochlear Implant Recipient

    by Gavriel D. Kohlberg, Dean M. Mancuso, Divya A. Chari, Anil K. Lalwani

    Objective. Enjoyment of music remains an elusive goal following cochlear implantation. We test the hypothesis that reengineering music to reduce its complexity can enhance the listening experience for the cochlear implant (CI) listener.Methods. Normal hearing (NH) adults (N=16) and CI listeners (N=9) evaluated a piece of country music on three enjoyment modalities: pleasantness, musicality, and naturalness. Participants listened to the original version along with 20 modified, less complex, versions created by including subsets of the musical instruments from the original song. NH participants listened to the segments both with and without CI simulation processing.Results. Compared to the original song, modified versions containing only 1–3 instruments were less enjoyable to the NH listeners but more enjoyable to the CI listeners and the NH listeners with CI simulation. Excluding vocals and including rhythmic instruments improved enjoyment for NH listeners with CI simulation but made no difference for CI listeners.Conclusions. Reengineering a piece of music to reduce its complexity has the potential to enhance music enjoyment for the cochlear implantee. Thus, in addition to improvements in software and hardware, engineering music specifically for the CI listener may be an alternative means to enhance their listening experience.


  • Reverberation Time Influences Musical Enjoyment With Cochlear Implants

    by Michael V. Certo, Gavriel D. Kohlberg, Divya A. Chari, Dean M. Mancuso, Anil K. Lalwani

    Objective To identify factors that enhance the enjoyment of music in cochlear implant (CI) recipients. Specifically, we assessed the hypothesis that variations in reverberation time (RT60) may be linked to variations in the level of musical enjoyment in CI users. Study design Prospective analysis of music enjoyment in normal-hearing individuals. Setting Single tertiary academic medical center. Patients Normal-hearing adults (N = 20) were asked to rate a novel 20-second melody on three enjoyment modalities: musicality, pleasantness, and naturalness. Intervention Subjective rating of music excerpts. Main outcome measures Participants listened to seven different instruments play the melody, each with five levels (0.2, 1.6, 3.0, 5.0, 10.0 s) of RT60, both with and without CI simulation processing. Linear regression analysis with analysis of variance was used to assess the impact of RT60 on music enjoyment. Results Without CI simulation, music samples with RT60 = 3.0 seconds were ranked most pleasant and most musical, whereas those with RT60 = 1.6 seconds and RT60 = 3.0 seconds were ranked equally most natural (all p < 0.05). With CI simulation, music samples with RT60 = 0.2 seconds were ranked most pleasant, most musical, and most natural (all p < 0.05). Samples without CI simulation show a preference for middle-range RT60, whereas samples with CI simulation show a negative linear relationship between RT60 and musical enjoyment, with preference for minimal reverberation. Conclusion Minimization of RT60 may be a useful strategy for increasing musical enjoyment under CI conditions, both in altering existing music as well as in composition of new music.


  • Carotid Space Mass

    by Gavriel David Kohlberg, Brian Jacob Stater, David Ivan Kutler, William Isadore Kuhel, Marc Andrew Cohen

    Case report from JAMA Otolaryngology–Head & Neck Surgery — Carotid Space Mass