Wiam El Ghoul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wiam El Ghoul has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Ziad Salameh
Research Center Faculty of Dental Medicine Lebanese University Beirut Lebanon
4 shared publications- Mutlu Özcan
Center for Dental Medicine, Clinic of Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland
2 shared publications - Haider Ali Ibrahim
Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq
1 shared publication Haider Hasan Jasim
Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq
1 shared publication- Hani Fouad Ounsi
Department of Restorative Dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
1 shared publication Hani Tohme
Department of Prosthodontics, School of Dentistry, Saint Joseph University, Beirut, Lebanon
1 shared publication
Latest Publications
- 26 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107033
Comparative evaluation of bilayered and monolithic endocrowns: Fracture resistance, failure mode, and stress distribution
- 26 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107033
Comparative evaluation of bilayered and monolithic endocrowns: Fracture resistance, failure mode, and stress distribution
- 10 October 2020
- Published by Wiley in Journal of Prosthodontics
- Vol. 30 (6) , 509-514
Marginal and Internal Adaptation of Lithium Disilicate Endocrowns Fabricated By Heat‐Pressable and Subtractive Techniques
Purpose: To evaluate and to compare the marginal and the internal fit of milled (MLE) and heat‐pressed lithium disilicate endocrowns (PLE).Materials and Methods: Thirty mandibular molars were prepared following the circumferential butt margin endocrown preparations; the cervical margin is parallel to the occlusal surface without ferrule design. A digital scan of molars was made using an intraoral digital scanner. The samples were separated into two groups (n = 15 per group); MLE: endocrowns were milled using LDS blocks and a 5‐axis milling machine, PLE: endocrowns were heat‐pressed using lost wax technique and LDS ingots. Marginal and internal adaptation were assessed using a replica technique and a stereomicroscope, selecting 32 measurements on each endocrown. Data were analyzed with one‐way repeated measures ANOVA, two‐way repeated measures ANOVA, student's t‐test and paired student t‐test (α = 0.05).Results: Statistically significant interactions were recorded between fabrication technique and region (p < 0.05), F (1.97, 27.69) = 5.462. Group MLE displayed significantly smaller gaps than PLE in all regions (p < 0.001). The largest gap was observed at the pulpal floor in both groups. The internal gap was significantly larger than the marginal gap in MLE group (p < 0.001), while no statistically significant difference was observed in PLE group (p = 0.082).Conclusion: Heat‐pressed and milled lithium disilicate endocrowns are clinically suitable, but the milled technique displayed a better fit than heat‐pressed technique when marginal and internal adaptation were examined.
- 10 October 2020
- Published by Wiley in Journal of Prosthodontics
- Vol. 30 (6) , 509-514
Marginal and Internal Adaptation of Lithium Disilicate Endocrowns Fabricated By Heat‐Pressable and Subtractive Techniques
Purpose: To evaluate and to compare the marginal and the internal fit of milled (MLE) and heat‐pressed lithium disilicate endocrowns (PLE).Materials and Methods: Thirty mandibular molars were prepared following the circumferential butt margin endocrown preparations; the cervical margin is parallel to the occlusal surface without ferrule design. A digital scan of molars was made using an intraoral digital scanner. The samples were separated into two groups (n = 15 per group); MLE: endocrowns were milled using LDS blocks and a 5‐axis milling machine, PLE: endocrowns were heat‐pressed using lost wax technique and LDS ingots. Marginal and internal adaptation were assessed using a replica technique and a stereomicroscope, selecting 32 measurements on each endocrown. Data were analyzed with one‐way repeated measures ANOVA, two‐way repeated measures ANOVA, student's t‐test and paired student t‐test (α = 0.05).Results: Statistically significant interactions were recorded between fabrication technique and region (p < 0.05), F (1.97, 27.69) = 5.462. Group MLE displayed significantly smaller gaps than PLE in all regions (p < 0.001). The largest gap was observed at the pulpal floor in both groups. The internal gap was significantly larger than the marginal gap in MLE group (p < 0.001), while no statistically significant difference was observed in PLE group (p = 0.082).Conclusion: Heat‐pressed and milled lithium disilicate endocrowns are clinically suitable, but the milled technique displayed a better fit than heat‐pressed technique when marginal and internal adaptation were examined.
- Open Access
- 1 January 2020
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 7 (1) , 110-119
Fracture resistance, failure mode and stress concentration in a modified endocrown design
The purpose of this study was to assess fracture resistance, failure mode and stress concentration of a modified endocrown preparation design, under axial and lateral forces. Forty lower molars wer...
- 1 January 2020
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 7 (1) , 110-119
Open AccessFracture resistance, failure mode and stress concentration in a modified endocrown design
The purpose of this study was to assess fracture resistance, failure mode and stress concentration of a modified endocrown preparation design, under axial and lateral forces. Forty lower molars wer...
- 1 January 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (1) , 128-134
Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study
- 1 January 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (1) , 128-134
Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study
- 8 May 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (4) , 378-387
Fracture resistance and failure modes of endocrowns manufactured with different CAD/CAM materials under axial and lateral loading
Objectives: The purpose of this in vitro study was to evaluate the fracture resistance and failure modes of endocrowns made of three computer‐aided design/computer‐aided manufacturing (CAD/CAM) materials subjected to thermo‐mechanical cycling loading.Materials and Methods: Eighty mandibular molars were divided into four groups (n = 20): one (C E) was restored with lithium disilicate glass‐ceramic conventional crowns, three were restored with endocrowns made of three different CAD/CAM materials; (E E) lithium disilicate glass‐ceramic, (E V) zirconia‐reinforced lithium silicate glass‐ceramic, and (E C) resin nano‐ceramic. After cycling loading, half of the samples from each group were loaded axially and the other half was loaded laterally. Fracture resistance was recorded in Newton (N) and failure modes were classified. Two‐way ANOVA, Bonferroni post hoc (α = .05), Chi‐square, and multiple logistic regression tests were used to analyze data.Results: Statistically significant interaction were recorded between fracture resistance (N) and loading (P < .001), and groups (conventuional crown and endocrowns; P < .001). Endocrowns presented higher fracture strength than conventional crowns. Fracture resistance was significantly larger under axial loading. The numbers of irreparable failures were extremely important in the endocrowns groups (Groups E E, E V, E C), and only conventional crowns (Group C E) showed almost no irreparable failures under axial loading.Conclusion: Lithium disilicate glass‐ceramic recorded the highest fracture resistance under axial and lateral loading.Clinical Significance: The number of irreparable failures with all endocrown materials tested do not suggest yet the use of this type of restorations in posterior teeth.
- 8 May 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 31 (4) , 378-387
Fracture resistance and failure modes of endocrowns manufactured with different CAD/CAM materials under axial and lateral loading
Objectives: The purpose of this in vitro study was to evaluate the fracture resistance and failure modes of endocrowns made of three computer‐aided design/computer‐aided manufacturing (CAD/CAM) materials subjected to thermo‐mechanical cycling loading.Materials and Methods: Eighty mandibular molars were divided into four groups (n = 20): one (C E) was restored with lithium disilicate glass‐ceramic conventional crowns, three were restored with endocrowns made of three different CAD/CAM materials; (E E) lithium disilicate glass‐ceramic, (E V) zirconia‐reinforced lithium silicate glass‐ceramic, and (E C) resin nano‐ceramic. After cycling loading, half of the samples from each group were loaded axially and the other half was loaded laterally. Fracture resistance was recorded in Newton (N) and failure modes were classified. Two‐way ANOVA, Bonferroni post hoc (α = .05), Chi‐square, and multiple logistic regression tests were used to analyze data.Results: Statistically significant interaction were recorded between fracture resistance (N) and loading (P < .001), and groups (conventuional crown and endocrowns; P < .001). Endocrowns presented higher fracture strength than conventional crowns. Fracture resistance was significantly larger under axial loading. The numbers of irreparable failures were extremely important in the endocrowns groups (Groups E E, E V, E C), and only conventional crowns (Group C E) showed almost no irreparable failures under axial loading.Conclusion: Lithium disilicate glass‐ceramic recorded the highest fracture resistance under axial and lateral loading.Clinical Significance: The number of irreparable failures with all endocrown materials tested do not suggest yet the use of this type of restorations in posterior teeth.