HNHansrudi Noser

Hansrudi Noser

*This is an algorithmically generated author record based on publicly available information.

Hansrudi Noser has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial intelligence and CT‐based 3D statistical modeling to assess transsacral corridors and plan implant positioning

    by Lukas Kamer, Hansrudi Noser, Charlotte Arand, Kristin Handrich, Pol Maria Rommens, Daniel Wagner

    Trans‐sacral corridors at level S1 and S2 represent complex osseous spaces allowing percutaneous fixation of non or minimally displaced fragility fractures of the sacrum. To safely place trans‐sacral implants, they must be completely intraosseous. However, standard radiographs and CT do not properly demonstrate the corridor's intricate configuration. Our goal was to facilitate the three‐dimensional assessment of trans‐sacral corridors using artificial intelligence and the planning of trans‐sacral implant positioning. One hundred pelvic CTs (49 females, mean age: 58.6 ±SD 14.8 years; 51 males, mean age: 60.7 ±SD 13 years) were used to compute a 3D statistical model of the pelvic ring. Based on morphologic features (=predictors) and Principal Components scores (=response), regression learners were interactively trained, validated, and tuned to predict / sample personalized 3D pelvic models. They were matched via Thin Plate Spline Transformation to a series of 20 pelvic CTs with fragility fractures of the sacrum (18 females and 2 males, age: 69‐9.5 years, mean age: 78.65 ±SD 8.4 years). These models demonstrated the availability, dimension, cross‐section, and symmetry of trans‐sacral corridors S1 and S2, furthermore, the planned implant position, dimension, axes, entry, and exit points. Complete intraosseous pathway was controlled in CT reconstructions. We succeeded to establish a workflow determining trans‐sacral corridors S1 and S2 using Artificial Intelligence and 3D statistical modeling.


  • Space available for trans-sacral implants to treat fractures of the pelvis assessed by virtual implant positioning

    by Daniel Wagner, Lukas Kamer, Takeshi Sawaguchi, Hansrudi Noser, Masafumi Uesugi, Andreas Baranowski, Dominik Gruszka, Pol M. Rommens

    The use of trans-sacral implants to treat fractures of the sacrum is limited by the variable pelvic anatomy. We were interested in how many trans-sacral implants can be placed per pelvis? If a trans-sacral implant cannot be placed in S1, where is the cortex perforated, and is the use of sacroiliac screws safe in these pelves?


  • 3D statistical model of the pelvic ring – a CT‐based statistical evaluation of anatomical variation

    by Charlotte Arand, Daniel Wagner, Robert Geoff Richards, Hansrudi Noser, Lukas Kamer, Takeshi Sawaguchi, Pol M. Rommens

    The pelvic ring is a highly complex construct with a central role for human stability and mobility. The observable interindividual differences in skeletal anatomy are caused by anatomical variation in the innominate bones as well as the sacrum, further to differences in the spatial arrangement of these bones to each other. The aim of this study was to generate a 3D statistical model of the entire pelvic ring in order to analyse the observed interindividual differences and anatomical variation. A series of 50 anonymized pelvic CT scans of uninjured Japanese adults [30 males, 20 females, average age of 74.9 years, standard deviation (SD) 16.9 years] were processed and analysed, resulting in a 3D statistical overall mean model and separate male and female mean models. Principal component analysis (PCA) of the overall statistical model predominantly showed size variation (20.39%) followed by shape variation (14.13%), and a variation of the spatial arrangement of the sacrum to the innominate bones in different anatomical peculiarities (11.39 and 8.85%). In addition, selected internal and external pelvic parameters were manually measured with the objective of further evaluating and quantifying the observed interindividual as well as the known sex‐specific differences. A separate statistical model of the grey value distribution based on the given Hounsfield unit (HU) values was calculated for assessing bone mass distribution, thus an indication of bone quality utilizing grey values as a quantitative description of radiodensity was obtained. A consistent pattern of grey value distribution was shown, with the highest grey values observed between the sacro‐iliac joint and the acetabulum along the pelvic brim. Low values were present in the sacral ala, in the area of the iliac fossa as well as in the pubic rami next to the symphysis. The present model allows a differentiated analysis of the observed interindividual variation of the pelvic ring and an evaluation of the grey value distribution therein. Besides providing a better understanding of anatomical variation, this model could be also used as a helpful tool for educational purposes, preoperative planning and implant design.


  • Open Access

    Secure corridor for infraacetabular screws in acetabular fracture fixation—a 3-D radiomorphometric analysis of 124 pelvic CT datasets

    by Stephan Arlt, Hansrudi Noser, Andreas Wienke, Florian Radetzki, Gunther Olaf Hofmann, Thomas Mendel

    Acetabular fracture surgery is directed toward anatomical reduction and stable fixation to allow for the early functional rehabilitation of an injured hip joint. Recent biomechanical investigations have shown the superiority of using an additional screw in the infraacetabular (IA) region, thereby transfixing the separated columns to strengthen the construct by closing the periacetabular fixation frame. However, the inter-individual existence and variance concerning secure IA screw corridors are poorly understood. This computer-aided 3-D radiomorphometric study examined 124 CT Digital Imaging and Communications in Medicine (DICOM) datasets of intact human pelves (248 acetabula) to visualize the spatial IA corridors as the sum of all intraosseous screw positions. DICOM files were pre-processed using the Amira® 4.2 visualization software. Final corridor computation was accomplished using a custom-made software algorithm. The volumetric measurement data of each corridor were calculated for further statistical analyses. Correlations between the volumetric values and the biometric data were investigated. Furthermore, the influence of hip dysplasia on the IA corridor configuration was analyzed. The IA corridors consistently showed a double-cone shape with the isthmus located at the acetabular fovea. In 97% of male and 91% of female acetabula, a corridor for a 3.5-mm screw could be found. The number of IA corridors was significantly lower in females for screw diameters ≥ 4.5 mm. The mean 3.5-mm screw corridor volume was 16 cm3 in males and 9.2 cm3 in female pelves. Corridor volumes were significantly positively correlated with body height and weight and with the diameter of Köhler’s teardrop on standard AP pelvic X-rays. No correlation was observed between hip dysplasia and the IA corridor extent. IA corridors are consistently smaller in females. However, 3.5-mm small fragment screws may still be used as the standard implant because sex-specific differences are significant only with screw diameters ≥ 4.5 mm. Congenital hip dysplasia does not affect secure IA screw insertion. The described method allows 3-D shape analyses with highly reliable results. The visualization of secure IA corridors may support the spatial awareness of surgeons. Volumetric data allow the reliable assessment of individual IA corridors using standard AP X-ray views, which aids preoperative planning.


  • Fragility fractures of the sacrum occur in elderly patients with severe loss of sacral bone mass

    by Daniel Wagner, Alexander Hofmann, Lukas Kamer, Takeshi Sawaguchi, R. Geoff Richards, Hansrudi Noser, Dominik Gruszka, Pol M. Rommens

    Patients suffering from osteoporosis-associated fragility fractures of the sacrum (FFS; also termed sacral insufficiency fractures) are increasingly observed. They have typical fracture patterns with fracture lines located in the sacral ala. When treating these patients operatively, iliosacral screw loosening is not uncommon. We aimed to study the sacral bone mass in patients presenting with a FFS using 3D statistical models.


  • Morphometry of the sacrum and its implication on trans-sacral corridors using a computed tomography data-based three-dimensional statistical model

    by Daniel Wagner, Lukas Kamer, Takeshi Sawaguchi, Robert Geoff Richards, Hansrudi Noser, Alexander Hofmann, Pol M. Rommens


  • Critical dimensions of trans‐sacral corridors assessed by 3D CT models: Relevance for implant positioning in fractures of the sacrum

    by Daniel Wagner, Lukas Kamer, Takeshi Sawaguchi, R. Geoff Richards, Hansrudi Noser, Masafumi Uesugi, Christian Ossendorf, Pol M. Rommens

    Trans‐sacral implants can be used alternatively to sacro‐iliac screws in the treatment of osteoporosis‐associated fragility fractures of the pelvis and the sacrum. We investigated trans‐sacral corridor dimensions, the number of individuals amenable to trans‐sacral fixation, as well as the osseous boundaries and shape of the S1 corridor. 3D models were reconstructed from pelvic CT scans from 92 Europeans and 64 Japanese. A corridor of <12 mm was considered critical for trans‐sacral implant positioning, and <8 mm as impossible. A statistical model of trans‐sacral corridor S1 was computed. The limiting cranio‐caudal diameter was 11.6 mm (±5.4) for S1 and 14 mm (±2.4) for S2. Trans‐sacral implant positioning was critical in 52% of cases for S1, and in 21% for S2. The S1 corridor was impossible in 26%, with no impossible corridor in S2. Antero‐superiorly, the S1 corridor was limited not only by the sacrum but in 40% by the iliac fossa. The statistical model demonstrated a consistent oval shape of the trans‐section of corridor S1. Considering the variable in size and shape of trans‐sacral corridors in S1, a thorough anatomical knowledge and preoperative planning are mandatory using trans‐sacral implants. In critical cases, S2 is a veritable alternative. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2577–2584, 2017.


  • Open Access

    Computational anatomy of the dens axis evaluated by quantitative computed tomography: Implications for anterior screw fixation

    by Dominic Gehweiler, Dirk Wähnert, Norbert Meier, Maarten Spruit, Michael Johannes Raschke, Robert Geoff Richards, Hansrudi Noser, Lukas Kamer

    The surgical fracture fixation of the odontoid process (dens) of the second cervical vertebra (C2/axis) is a challenging procedure, particularly in elderly patients affected by bone loss, and includes screw positioning close to vital structures. The aim of this study was to provide an extended anatomical knowledge of C2, the bone mass distribution and bone loss, and to understand the implications for anterior screw fixation. One hundred and twenty standard clinical quantitative computed tomography (QCT) scans of the intact cervical spine from 60 female and 60 male European patients, aged 18–90 years, were used to compute a three‐dimensional statistical model and an averaged bone mass model of C2. Shape and size variability was assessed via principal component analysis (PCA), bone mass distribution by thresholding and via virtual core drilling, and the screw placement via virtual positioning of screw templates. Principal component analysis (PCA) revealed a highly variable anatomy of the dens with size as the predominant variation according to the first principal component (PC) whereas shape changes were primarily described by the remaining PCs. The bone mass distribution demonstrated a characteristic 3D pattern, and remained unchanged in the presence of bone loss. Virtual screw positioning of two 3.5 mm dens screws with a 1 mm safety zone was possible in 81.7% in a standard, parallel position and in additional 15.8% in a twisted position. The approach permitted a more detailed anatomical assessment of the dens axis. Combined with a preoperative QCT it may further improve the diagnostic procedure of odontoid fractures. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2154–2163, 2017.


  • Bone Mass Distribution of the Distal Tibia in Normal, Osteopenic, and Osteoporotic Conditions: An Ex Vivo Assessment Using HR-pQCT, DXA, and Computational Modelling

    by Lukas Kamer, Hansrudi Noser, Michael Blauth, Mark Lenz, Markus Windolf, Albrecht W. Popp

    Osteoporosis leads to bone loss and structural deterioration, which increase the risk of fractures. The aim of this study was to characterize the three-dimensional (3D) bone mass distributions of the distal tibia in normal, osteopenic, and osteoporotic conditions. High-resolution peripheral quantitative computed tomography (HR-pQCT) of the 33 % of the distal tibia and local dual-energy X-ray absorptiometry were applied to 53 intact, fresh-frozen tibiae. The HR-pQCTs were graded to assign local T-scores and merged into three equally sized average normal, osteopenic, and osteoporotic surface models. Volumetric bone mineral density (vBMD) was determined using categorized T-scores, volumetric visualization, and virtual bore probes at the dia-, meta-, and epiphyseal sites (T-DIA, T-META, and T-EPI). We observed a distinct 3D bone mass distribution that was gradually uninfluenced by T-score categories. T-DIA was characterized by the lowest bone mass located in the medullary cavity and a wide homogenous cortex containing the maximum vBMD. The T-META showed decreased cortical thickness and maximal vBMD. At the T-EPI, the relatively low vBMD of the mostly trabecular bone was similar to the maximal cortical vBMD in this sub-region. Four trabecular regions of low bone mass were identified in the recesses. The bone content gradually decreased at all sites, whereas the pattern of bone mass distribution remained essentially unchanged, with the exception of disproportionate losses at T-DIA, T-META, and T-EPI that consistently showed increased endocortical, intracortical, and trabecular bone loss. Extra information can be obtained from the specific pattern of bone mass distribution, potential disproportionate bone losses, and method used.


  • Sacral Bone Mass Distribution Assessed by Averaged Three-Dimensional CT Models

    by Daniel Wagner, Lukas Kamer, Takeshi Sawaguchi, R. Geoff Richards, Hansrudi Noser, Pol M. Rommens

    Background: Fragility fractures of the sacrum are increasing in prevalence due to osteoporosis and epidemiological changes and are challenging in their treatment. They exhibit specific fracture patterns with unilateral or bilateral fractures lateral to the sacral foramina, and sometimes an additional transverse fracture leads to spinopelvic dissociation. The goal of this study was to assess sacral bone mass distribution and corresponding changes with decreased general bone mass. Methods: Clinical computed tomography (CT) scans of intact pelves in ninety-one individuals (mean age and standard deviation, 61.5 ± 11.3 years) were used to generate three-dimensional (3D) models of the sacrum averaging bone mass in Hounsfield units (HU). Individuals with decreased general bone mass were identified by measuring bone mass in L5 (group 1 with <100 HU; in contrast to group 2 with ≥100 HU). Results: In group 1, a large zone of negative Hounsfield units was located in the paraforaminal lateral region from S1 to S3. Along the trans-sacral corridors, a Hounsfield unit peak was observed laterally, corresponding to cortical bone of the auricular surface. The lowest Hounsfield unit values were found in the paraforaminal lateral region in the sacral ala. An intermediate level of bone mass was observed in the area of the vertebral bodies, which also demonstrated the largest difference between groups 1 and 2. Overall, the Hounsfield units were lower at S2 than S1. Conclusions: The models of averaged bone mass in the sacrum revealed a distinct 3D distribution pattern. Clinical Relevance: The negative values in the paraforaminal lateral region may explain the specific fracture patterns in fragility fractures of the sacrum involving the lateral areas of the sacrum. Transverse fractures located between S1 and S2 leading to spinopelvic dissociation may occur because of decreased bone mass in S2. The largest difference between the studied groups was found in the vertebral bodies and might support the use of transsacral or cement-augmented implants.