Jhonattan de la Roche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jhonattan de la Roche has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Toro
Tribology and Surfaces Group, Universidad Nacional de Colombia, Medellín 050034, Colombia
4 shared publications - Elisabeth Restrepo Parra
Laboratorio de Física del Plasma, Universidad Nacional de Colombia Sede Manizales, Manizales 170003, Colombia
3 shared publications Alejandro Toro
Tribology and Surfaces Group, Universidad Nacional de Colombia, Medellín, Colombia
2 shared publications- Andres Jaramillo-Botero
OMICAS Research Institute, Pontificia Universidad Javeriana, Calle 17 # 121B-155, Cali, Valle Del Cauca 760031, Colombia
2 shared publications - Juan Manuel Alvarado Orozco
Center for Engineering and Industrial Development, Querétaro, Mexico
2 shared publications Pablo Gómez
Empresas Públicas de Medellín – EPM, Medellín, Colombia
2 shared publications
Latest Publications
- Open Access
- 6 February 2026
- Published by Universidad del Valle in INGENIERÍA Y COMPETITIVIDAD
- Vol. 28 (1)
Design of Experiments to enhance spraying parameters for YSZ coatings via Atmospheric Plasma Spraying
Objetivos: Implementar la metodología de Diseño de Experimentos (DOE) para obtener los parámetros de proyección en la deposición de circonia estabilizada con itria (YSZ) sobre Inconel 625 mediante proyección térmica por plasma atmosférico (APS).Metodología: Se implementó un diseño factorial 32 con tres repeticiones, en el cual los factores fueron la corriente eléctrica y el flujo de hidrógeno. Las variables respuesta fueron la velocidad media y la temperatura de las partículas en vuelo. La calidad de los recubrimientos se evaluó en función del porcentaje de fase tetragonal, la porosidad y el espesor.Resultados: Las muestras depositadas entre 430 A y flujos de H₂ de 7 y 9 NLPM exhibieron las características más sobresalientes. La muestra depositada a 430 A y 7 NLPM de H₂ fue sometida a pruebas de choque térmico.Conclusiones: La muestra depositada a 430 A y 7 NLPM de H₂ demostró un rendimiento superior al de recubrimientos similares documentados en la literatura científica.
- 6 February 2026
- Published by Universidad del Valle in INGENIERÍA Y COMPETITIVIDAD
- Vol. 28 (1)
Open AccessDesign of Experiments to enhance spraying parameters for YSZ coatings via Atmospheric Plasma Spraying
Objetivos: Implementar la metodología de Diseño de Experimentos (DOE) para obtener los parámetros de proyección en la deposición de circonia estabilizada con itria (YSZ) sobre Inconel 625 mediante proyección térmica por plasma atmosférico (APS).Metodología: Se implementó un diseño factorial 32 con tres repeticiones, en el cual los factores fueron la corriente eléctrica y el flujo de hidrógeno. Las variables respuesta fueron la velocidad media y la temperatura de las partículas en vuelo. La calidad de los recubrimientos se evaluó en función del porcentaje de fase tetragonal, la porosidad y el espesor.Resultados: Las muestras depositadas entre 430 A y flujos de H₂ de 7 y 9 NLPM exhibieron las características más sobresalientes. La muestra depositada a 430 A y 7 NLPM de H₂ fue sometida a pruebas de choque térmico.Conclusiones: La muestra depositada a 430 A y 7 NLPM de H₂ demostró un rendimiento superior al de recubrimientos similares documentados en la literatura científica.
- Open Access
- 19 November 2025
- Published by IntechOpen
Home Monitoring Systems: IoT and AI Innovation for Cardio-Cerebrovascular Disease Care
The monitoring of cardio-cerebrovascular diseases increasingly underscores the importance of understanding and utilizing advanced devices, particularly those enhanced by Internet of Things (IoT) and Artificial Intelligence (AI) technologies. These innovations have significantly transformed healthcare, especially in managing heart failure—a chronic condition affecting 26 million people globally and the leading cause of hospitalization among individuals over 65 years age. Monitoring systems track critical variables, including heart rate, blood pressure, oxygen saturation, body weight, dyspnea, and lower limb edema, providing essential data for evaluating treatment efficacy. A key advantage of these technologies is their ability to enable home-based monitoring, reducing hospital readmissions and lowering healthcare costs. This chapter examines how AI-driven technologies facilitate timely and effective interventions for heart failure, enhancing patient outcomes and quality of life. Furthermore, it traces the evolution of these advancements, highlighting their contributions to the field and potential to optimize disease management. By integrating precise monitoring with advanced analytics, these systems offer a transformative approach to medical care, demonstrating their value in improving both clinical and economic aspects of health management.
- 19 November 2025
- Published by IntechOpen
Open AccessHome Monitoring Systems: IoT and AI Innovation for Cardio-Cerebrovascular Disease Care
The monitoring of cardio-cerebrovascular diseases increasingly underscores the importance of understanding and utilizing advanced devices, particularly those enhanced by Internet of Things (IoT) and Artificial Intelligence (AI) technologies. These innovations have significantly transformed healthcare, especially in managing heart failure—a chronic condition affecting 26 million people globally and the leading cause of hospitalization among individuals over 65 years age. Monitoring systems track critical variables, including heart rate, blood pressure, oxygen saturation, body weight, dyspnea, and lower limb edema, providing essential data for evaluating treatment efficacy. A key advantage of these technologies is their ability to enable home-based monitoring, reducing hospital readmissions and lowering healthcare costs. This chapter examines how AI-driven technologies facilitate timely and effective interventions for heart failure, enhancing patient outcomes and quality of life. Furthermore, it traces the evolution of these advancements, highlighting their contributions to the field and potential to optimize disease management. By integrating precise monitoring with advanced analytics, these systems offer a transformative approach to medical care, demonstrating their value in improving both clinical and economic aspects of health management.
- Open Access
- 6 August 2025
- Published by Springer Nature in Journal of Thermal Spray Technology
- p. 1-11
Effect of Total Combustion Flow and Combustion Ratio on the Cavitation Resistance of Hydrogen HVOF-Sprayed WC-Co-Cr Coatings
This work investigates the relationship between the cavitation resistance of WC-Co-Cr coatings and the high-velocity oxy-fuel (HVOF) spraying parameters utilized during their deposition. The coatings were applied using a fully automated spraying process with hydrogen and oxygen as combustion gases. A Design of Experiments (DoE) methodology was implemented, incorporating two factors—Total Combustion Flow (TCF) and Combustion Ratio (CR) —with three repetitions to ensure experimental repeatability. Cavitation resistance was evaluated according to the ASTM G32 standard. The results indicate that total combustion flow significantly influenced key coating characteristics, including roughness, microstructure, hardness, and WC retention index, whereas the combustion ratio exhibited no statistically significant effect. It was possible to improve the cavitation resistance of the WC-Co-Cr coatings using high levels of total combustion flow and a combustion ratio close to the stoichiometric point of the gas mixture.
- 6 August 2025
- Published by Springer Nature in Journal of Thermal Spray Technology
- p. 1-11
Open AccessEffect of Total Combustion Flow and Combustion Ratio on the Cavitation Resistance of Hydrogen HVOF-Sprayed WC-Co-Cr Coatings
This work investigates the relationship between the cavitation resistance of WC-Co-Cr coatings and the high-velocity oxy-fuel (HVOF) spraying parameters utilized during their deposition. The coatings were applied using a fully automated spraying process with hydrogen and oxygen as combustion gases. A Design of Experiments (DoE) methodology was implemented, incorporating two factors—Total Combustion Flow (TCF) and Combustion Ratio (CR) —with three repetitions to ensure experimental repeatability. Cavitation resistance was evaluated according to the ASTM G32 standard. The results indicate that total combustion flow significantly influenced key coating characteristics, including roughness, microstructure, hardness, and WC retention index, whereas the combustion ratio exhibited no statistically significant effect. It was possible to improve the cavitation resistance of the WC-Co-Cr coatings using high levels of total combustion flow and a combustion ratio close to the stoichiometric point of the gas mixture.
- Open Access
- 6 June 2025
- Published by Editorial Pontificia Universidad Javeriana in Universitas Scientiarum
UV-VIS laser parameter effects on the physicochemical properties of Laser-Induced Graphene
Laser-induced graphene (LIG) is a versatile and scalable technique for the low-cost production of graphene-like sensing devices. However, the performance of these devices is hypersensitive to the engraving parameters used during fabrication. In this work, we systematically varied laser engraving speed and power to explore their influence on the physical and electrochemical properties of LIG electrodes to achieve low resistance, high LIG porosity, and enhanced sensitivity for future sensing applications. We employed a UV-VIS diode laser mounted on a CNC (Computer Numerical Control) system constructed by our team to engrave on polyimide sheets. Our results demonstrated that low and high-power settings led to poor electrode performance due to increased resistivity and structural damage. Conversely, electrodes fabricated at power settings between 60 % (3W) and 80 % (4W) of the laser’s maximum capacity, combined with maximum operable speed, exhibited uniform morphology, high conductivity, and reversible electrochemical behavior. Under these conditions, the resulting LIG-based electrodes featured porous graphene on networks with directional asymmetry, with an ID/IG ratio of approximately 1.3, a sheet resistance of 20 Ω/sq, and a peak current of 272.1 uA, alongside an Ipa/Ipc ratio near 1 in cyclic voltammetry measurements, providing a foundation for the development of efficient LIG-based sensors.
- 6 June 2025
- Published by Editorial Pontificia Universidad Javeriana in Universitas Scientiarum
Open AccessUV-VIS laser parameter effects on the physicochemical properties of Laser-Induced Graphene
Laser-induced graphene (LIG) is a versatile and scalable technique for the low-cost production of graphene-like sensing devices. However, the performance of these devices is hypersensitive to the engraving parameters used during fabrication. In this work, we systematically varied laser engraving speed and power to explore their influence on the physical and electrochemical properties of LIG electrodes to achieve low resistance, high LIG porosity, and enhanced sensitivity for future sensing applications. We employed a UV-VIS diode laser mounted on a CNC (Computer Numerical Control) system constructed by our team to engrave on polyimide sheets. Our results demonstrated that low and high-power settings led to poor electrode performance due to increased resistivity and structural damage. Conversely, electrodes fabricated at power settings between 60 % (3W) and 80 % (4W) of the laser’s maximum capacity, combined with maximum operable speed, exhibited uniform morphology, high conductivity, and reversible electrochemical behavior. Under these conditions, the resulting LIG-based electrodes featured porous graphene on networks with directional asymmetry, with an ID/IG ratio of approximately 1.3, a sheet resistance of 20 Ω/sq, and a peak current of 272.1 uA, alongside an Ipa/Ipc ratio near 1 in cyclic voltammetry measurements, providing a foundation for the development of efficient LIG-based sensors.
- 17 March 2025
- Published by Wiley in Materials and Corrosion
- Vol. 76 (8) , 1190-1198
Influence of Iron Oxide Deposits on the Hot Corrosion Resistance of YSZ Thermal Barrier Coatings in Molten Vanadium Pentoxide
The effect of iron oxide (Fe₂O₃) deposits on the hot corrosion (HC) mechanisms of yttria‐stabilized zirconia (YSZ) thermal barrier coatings in the presence of vanadium oxide was investigated. The experiments involved exposing YSZ samples to vanadium pentoxide (V₂O₅) at 900°C for 90 min, both with and without the addition of Fe₂O₃. Surface and cross‐sectional analyses of the samples were conducted using optical microscopy, scanning electron microscopy (SEM/EDS), and X‐ray diffraction. Additionally, the porosity and delamination percentages of the thermal barrier coatings were quantified through digital image processing techniques. The primary damage mechanisms identified included yttria dissolution, which facilitated the tetragonal‐to‐monoclinic phase transformation of YSZ, as well as the infiltration of V₂O₅ through cracks and pores, leading to coating delamination near the Top Coat/Bond Coat (TC/BC) interface. Notably, Fe₂O₃ reacted with V₂O₅ during the tests, forming an iron‐vanadium oxide (FeV₃O₈). Furthermore, the presence of Fe₂O₃ increases the HC attack, reducing the tetragonal phase content of the YSZ coating.
- 17 March 2025
- Published by Wiley in Materials and Corrosion
- Vol. 76 (8) , 1190-1198
Influence of Iron Oxide Deposits on the Hot Corrosion Resistance of YSZ Thermal Barrier Coatings in Molten Vanadium Pentoxide
The effect of iron oxide (Fe₂O₃) deposits on the hot corrosion (HC) mechanisms of yttria‐stabilized zirconia (YSZ) thermal barrier coatings in the presence of vanadium oxide was investigated. The experiments involved exposing YSZ samples to vanadium pentoxide (V₂O₅) at 900°C for 90 min, both with and without the addition of Fe₂O₃. Surface and cross‐sectional analyses of the samples were conducted using optical microscopy, scanning electron microscopy (SEM/EDS), and X‐ray diffraction. Additionally, the porosity and delamination percentages of the thermal barrier coatings were quantified through digital image processing techniques. The primary damage mechanisms identified included yttria dissolution, which facilitated the tetragonal‐to‐monoclinic phase transformation of YSZ, as well as the infiltration of V₂O₅ through cracks and pores, leading to coating delamination near the Top Coat/Bond Coat (TC/BC) interface. Notably, Fe₂O₃ reacted with V₂O₅ during the tests, forming an iron‐vanadium oxide (FeV₃O₈). Furthermore, the presence of Fe₂O₃ increases the HC attack, reducing the tetragonal phase content of the YSZ coating.
- 17 December 2022
- Published by Springer Nature in Carbon Letters
- Vol. 33 (2) , 587-595
Influence of lasing parameters on the morphology and electrical resistance of polyimide-based laser-induced graphene (LIG)
- 17 December 2022
- Published by Springer Nature in Carbon Letters
- Vol. 33 (2) , 587-595
Influence of lasing parameters on the morphology and electrical resistance of polyimide-based laser-induced graphene (LIG)
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
SenSARS: A Low-Cost Portable Electrochemical System for Ultra-Sensitive, Near Real-Time, Diagnostics of SARS-CoV-2 Infections
A critical path to solving the SARS-CoV-2 pandemic, without further socioeconomic impact, is to stop its spread. For this to happen, pre- or asymptomatic individuals infected with the virus need to be detected and isolated opportunely. Unfortunately, there are no current ubiquitous (i.e., ultra-sensitive, cheap, and widely available) rapid testing tools capable of early detection of SARS-CoV-2 infections. In this article, we introduce an accurate, portable, and low-cost medical device and bio-nanosensing electrode dubbed SenSARS and its experimental validation. SenSARS’ device measures the electrochemical impedance spectra of a disposable bio-modified screen-printed carbon-based working electrode (SPCE) to the changes in the concentration of SARS-CoV-2 antigen molecules (“S” spike proteins) contained within a sub-microliter fluid sample deposited on its surface. SenSARS offers real-time diagnostics and viral load tracking capabilities. Positive and negative control tests were performed in phosphate-buffered saline (PBS) at different concentrations (between 1 and 50 fg/mL) of SARS-CoV-2(S), Epstein–Barr virus (EBV) glycoprotein gp350, and Influenza H1N1 M1 recombinant viral proteins. We demonstrate that SenSARS is easy to use, with a portable and lightweight (< 200 g) instrument and disposable test electrodes ( $\$ $ 5), capable of fast diagnosis (~10 min), with high analytical sensitivity (low limits of detection, LOD = 1.065 fg/mL, and quantitation, LOQ = 3.6 fg/mL) and selectivity to SARS-CoV-2(S) antigens, even in the presence of structural proteins from the other pathogens tested. SenSARS provides a potential path to pervasive rapid diagnostics of SARS-CoV-2 in clinical, point-of-care, and home-care settings, and to breaking the transmission chain of this virus. Medical device compliance testing of SenSARS to EIC-60601 technical standards is underway.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
SenSARS: A Low-Cost Portable Electrochemical System for Ultra-Sensitive, Near Real-Time, Diagnostics of SARS-CoV-2 Infections
A critical path to solving the SARS-CoV-2 pandemic, without further socioeconomic impact, is to stop its spread. For this to happen, pre- or asymptomatic individuals infected with the virus need to be detected and isolated opportunely. Unfortunately, there are no current ubiquitous (i.e., ultra-sensitive, cheap, and widely available) rapid testing tools capable of early detection of SARS-CoV-2 infections. In this article, we introduce an accurate, portable, and low-cost medical device and bio-nanosensing electrode dubbed SenSARS and its experimental validation. SenSARS’ device measures the electrochemical impedance spectra of a disposable bio-modified screen-printed carbon-based working electrode (SPCE) to the changes in the concentration of SARS-CoV-2 antigen molecules (“S” spike proteins) contained within a sub-microliter fluid sample deposited on its surface. SenSARS offers real-time diagnostics and viral load tracking capabilities. Positive and negative control tests were performed in phosphate-buffered saline (PBS) at different concentrations (between 1 and 50 fg/mL) of SARS-CoV-2(S), Epstein–Barr virus (EBV) glycoprotein gp350, and Influenza H1N1 M1 recombinant viral proteins. We demonstrate that SenSARS is easy to use, with a portable and lightweight (< 200 g) instrument and disposable test electrodes ( $\$ $ 5), capable of fast diagnosis (~10 min), with high analytical sensitivity (low limits of detection, LOD = 1.065 fg/mL, and quantitation, LOQ = 3.6 fg/mL) and selectivity to SARS-CoV-2(S) antigens, even in the presence of structural proteins from the other pathogens tested. SenSARS provides a potential path to pervasive rapid diagnostics of SARS-CoV-2 in clinical, point-of-care, and home-care settings, and to breaking the transmission chain of this virus. Medical device compliance testing of SenSARS to EIC-60601 technical standards is underway.
- 1 December 2020
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 40 (15) , 5692-5703
Hot corrosion and thermal shock resistance of Dense-CYSZ/YSZ bilayer thermal barrier coatings systems applied onto Ni-base superalloy
- 1 December 2020
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 40 (15) , 5692-5703
Hot corrosion and thermal shock resistance of Dense-CYSZ/YSZ bilayer thermal barrier coatings systems applied onto Ni-base superalloy
- 1 April 2020
- Published by Wiley in Rare Metals
- Vol. 40 (5) , 1307-1316
Hot corrosion mechanism of yttria‐stabilized zirconia powder in the presence of molten Na 2 SO 4 + V 2 O 5 salts
The hot corrosion behavior of yttria‐stabilized zirconia (YSZ) powder specimens exposed to Na 2 SO 4 /V 2 O 5 salts mixtures at high temperature was evaluated. Initial tests were carried out at 1000 °C for 10 h, the salt concentrations varied from 0.1 wt% to 1.00 wt%, and the Na 2 SO 4 /V 2 O 5 mass ratios were between 0.20 and 0.44 following a factorial design 2 2 . X‐ray diffraction (XRD) analyses of the tested samples showed with a confidence of 95% that the mixture composed of 32 wt% Na 2 SO 4 + 68 wt% V 2 O 5 , and 1.00 wt% salt concentration led to high destabilization of the t′‐YSZ phase and formation of YVO 4 products. A second set of experiments were conducted to assess the influence of temperature on the hot corrosion response of the YSZ in the range between 490 and 1100 °C. Thermogravimetric analysis (TGA) experiments and Rietveld adjustments of XRD patterns showed that the mass loss of the samples varied with testing temperature and also that the major destabilization of tetragonal phase occurred at 900 °C.
- 1 April 2020
- Published by Wiley in Rare Metals
- Vol. 40 (5) , 1307-1316
Hot corrosion mechanism of yttria‐stabilized zirconia powder in the presence of molten Na 2 SO 4 + V 2 O 5 salts
The hot corrosion behavior of yttria‐stabilized zirconia (YSZ) powder specimens exposed to Na 2 SO 4 /V 2 O 5 salts mixtures at high temperature was evaluated. Initial tests were carried out at 1000 °C for 10 h, the salt concentrations varied from 0.1 wt% to 1.00 wt%, and the Na 2 SO 4 /V 2 O 5 mass ratios were between 0.20 and 0.44 following a factorial design 2 2 . X‐ray diffraction (XRD) analyses of the tested samples showed with a confidence of 95% that the mixture composed of 32 wt% Na 2 SO 4 + 68 wt% V 2 O 5 , and 1.00 wt% salt concentration led to high destabilization of the t′‐YSZ phase and formation of YVO 4 products. A second set of experiments were conducted to assess the influence of temperature on the hot corrosion response of the YSZ in the range between 490 and 1100 °C. Thermogravimetric analysis (TGA) experiments and Rietveld adjustments of XRD patterns showed that the mass loss of the samples varied with testing temperature and also that the major destabilization of tetragonal phase occurred at 900 °C.