San-Yuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
San-Yuan Wang has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Yufeng Jane Tseng
Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
15 shared publications - Ching-Hua Kuo
School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan
12 shared publications - I-Lin Tsai
Department of Biochemistry and Molecular Cell Biology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
4 shared publications - Guan-Yuan Chen
Forensic and Clinical Toxicology Center, National Taiwan University Hospital, Taipei, Taiwan; Department and Graduate Institute of Forensic Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
3 shared publications - Hsiao-Wei Liao
Department of Pharmacy, College of Pharmaceutical Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
3 shared publications Chiang-Ching Huang
Department of Preventive Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Ill
2 shared publications
Latest Publications
- 23 June 2025
- Published by Elsevier in Journal of Ethnopharmacology
- Vol. 352, 120186
Establishing identifiable characteristic fingerprints of mulberry leaves: Integrating chemical composition and bioactivity through machine learning
- 23 June 2025
- Published by Elsevier in Journal of Ethnopharmacology
- Vol. 352, 120186
Establishing identifiable characteristic fingerprints of mulberry leaves: Integrating chemical composition and bioactivity through machine learning
- Open Access
- 2 October 2024
- Published by Elsevier in Journal of Microbiology, Immunology and Infection
- Vol. 58 (1) , 27-37
Unveiling unique effector function-related bulk antibody profiles in long-term hemodialysis patients following COVID-19 mRNA booster vaccination
- 2 October 2024
- Published by Elsevier in Journal of Microbiology, Immunology and Infection
- Vol. 58 (1) , 27-37
Open AccessUnveiling unique effector function-related bulk antibody profiles in long-term hemodialysis patients following COVID-19 mRNA booster vaccination
- 21 October 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1685, 463589
Development of an enrichment-free one-pot sample preparation and ultra-high performance liquid chromatography-tandem mass spectrometry method to identify Immunoglobulin A1 hinge region O-glycoforms for Immunoglobulin A nephropathy
- 21 October 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1685, 463589
Development of an enrichment-free one-pot sample preparation and ultra-high performance liquid chromatography-tandem mass spectrometry method to identify Immunoglobulin A1 hinge region O-glycoforms for Immunoglobulin A nephropathy
- Open Access
- 26 April 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106839
How platinum-induced nephrotoxicity occurs? Machine learning prediction in non-small cell lung cancer patients
- 26 April 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106839
Open AccessHow platinum-induced nephrotoxicity occurs? Machine learning prediction in non-small cell lung cancer patients
- 1 February 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 195, 113821
Determination of fluoroquinolones in dried plasma spots by using microwave-assisted extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring
- 1 February 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 195, 113821
Determination of fluoroquinolones in dried plasma spots by using microwave-assisted extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring
- 30 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (16) , 10702-10712
Improved Dried Blood Spot-Based Metabolomics Analysis by a Postcolumn Infused-Internal Standard Assisted Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method
Dried blood spots (DBSs) have gained increasing attention recently with their growing importance in precision medicine. DBS-based metabolomics analysis provides a powerful tool for investigating new biomarkers. Until now, very few studies have discussed measures for improving analytical accuracy with the consideration of the special characteristics of DBSs. The present study proposed a postcolumn infused-internal standard (PCI-IS) assisted strategy to improve data quality for DBS-based metabolomics studies. An efficient sample preparation protocol with 80% acetonitrile as the extraction solvent was first established to improve the metabolite recovery. The PCI-IS assisted liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was used to simultaneously estimate the blood volume and correct the signal change caused by ion source contamination and the matrix effect to evaluate the spot volume effect and hematocrit (Hct) variation effect on target metabolites. Phenylalanine-d8 was selected as the single PCI-IS to correct the matrix effect. For calibration of errors caused by the blood volume difference, 75% of the test metabolites showed good correlation (R2 ≥ 0.9) between the spot volume and the signal intensity after PCI-IS correction compared to less than 50% metabolites with good correlation before calibration. The spot volume was further calibrated by the same PCI-IS. Investigation of the Hct variation effect on target metabolites revealed that it affected the concentrations of metabolites in the DBS samples depending on their abundance in the red blood cell (RBC) or plasma; it is essential to preinvestigate the distribution of metabolites in blood to minimize the comparison bias in metabolomics studies. Finally, the PCI-IS assisted method was applied to study acetaminophen-induced liver toxicity. The results indicated that the proposed PCI-IS strategy could effectively remove analytical errors and improve the data quality, which would make the DBS-based metabolomics more feasible in real-world applications.
- 30 July 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (16) , 10702-10712
Improved Dried Blood Spot-Based Metabolomics Analysis by a Postcolumn Infused-Internal Standard Assisted Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method
Dried blood spots (DBSs) have gained increasing attention recently with their growing importance in precision medicine. DBS-based metabolomics analysis provides a powerful tool for investigating new biomarkers. Until now, very few studies have discussed measures for improving analytical accuracy with the consideration of the special characteristics of DBSs. The present study proposed a postcolumn infused-internal standard (PCI-IS) assisted strategy to improve data quality for DBS-based metabolomics studies. An efficient sample preparation protocol with 80% acetonitrile as the extraction solvent was first established to improve the metabolite recovery. The PCI-IS assisted liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was used to simultaneously estimate the blood volume and correct the signal change caused by ion source contamination and the matrix effect to evaluate the spot volume effect and hematocrit (Hct) variation effect on target metabolites. Phenylalanine-d8 was selected as the single PCI-IS to correct the matrix effect. For calibration of errors caused by the blood volume difference, 75% of the test metabolites showed good correlation (R2 ≥ 0.9) between the spot volume and the signal intensity after PCI-IS correction compared to less than 50% metabolites with good correlation before calibration. The spot volume was further calibrated by the same PCI-IS. Investigation of the Hct variation effect on target metabolites revealed that it affected the concentrations of metabolites in the DBS samples depending on their abundance in the red blood cell (RBC) or plasma; it is essential to preinvestigate the distribution of metabolites in blood to minimize the comparison bias in metabolomics studies. Finally, the PCI-IS assisted method was applied to study acetaminophen-induced liver toxicity. The results indicated that the proposed PCI-IS strategy could effectively remove analytical errors and improve the data quality, which would make the DBS-based metabolomics more feasible in real-world applications.
- Open Access
- 15 November 2017
- Published by Springer Nature in Journal of Cheminformatics
- Vol. 9 (1) , 57
An efficient computer-aided structural elucidation strategy for mixtures using an iterative dynamic programming algorithm
The identification of chemical structures in natural product mixtures is an important task in drug discovery but is still a challenging problem, as structural elucidation is a time-consuming process and is limited by the available mass spectra of known natural products. Computer-aided structure elucidation (CASE) strategies seek to automatically propose a list of possible chemical structures in mixtures by utilizing chromatographic and spectroscopic methods. However, current CASE tools still cannot automatically solve structures for experienced natural product chemists. Here, we formulated the structural elucidation of natural products in a mixture as a computational problem by extending a list of scaffolds using a weighted side chain list after analyzing a collection of 243,130 natural products and designed an efficient algorithm to precisely identify the chemical structures. The complexity of such a problem is NP-complete. A dynamic programming (DP) algorithm can solve this NP-complete problem in pseudo-polynomial time after converting floating point molecular weights into integers. However, the running time of the DP algorithm degrades exponentially as the precision of the mass spectrometry experiment grows. To ideally solve in polynomial time, we proposed a novel iterative DP algorithm that can quickly recognize the chemical structures of natural products. By utilizing this algorithm to elucidate the structures of four natural products that were experimentally and structurally determined, the algorithm can search the exact solutions, and the time performance was shown to be in polynomial time for average cases. The proposed method improved the speed of the structural elucidation of natural products and helped broaden the spectrum of available compounds that could be applied as new drug candidates. A web service built for structural elucidation studies is freely accessible via the following link ( http://csccp.cmdm.tw/ ).
- 15 November 2017
- Published by Springer Nature in Journal of Cheminformatics
- Vol. 9 (1) , 57
Open AccessAn efficient computer-aided structural elucidation strategy for mixtures using an iterative dynamic programming algorithm
The identification of chemical structures in natural product mixtures is an important task in drug discovery but is still a challenging problem, as structural elucidation is a time-consuming process and is limited by the available mass spectra of known natural products. Computer-aided structure elucidation (CASE) strategies seek to automatically propose a list of possible chemical structures in mixtures by utilizing chromatographic and spectroscopic methods. However, current CASE tools still cannot automatically solve structures for experienced natural product chemists. Here, we formulated the structural elucidation of natural products in a mixture as a computational problem by extending a list of scaffolds using a weighted side chain list after analyzing a collection of 243,130 natural products and designed an efficient algorithm to precisely identify the chemical structures. The complexity of such a problem is NP-complete. A dynamic programming (DP) algorithm can solve this NP-complete problem in pseudo-polynomial time after converting floating point molecular weights into integers. However, the running time of the DP algorithm degrades exponentially as the precision of the mass spectrometry experiment grows. To ideally solve in polynomial time, we proposed a novel iterative DP algorithm that can quickly recognize the chemical structures of natural products. By utilizing this algorithm to elucidate the structures of four natural products that were experimentally and structurally determined, the algorithm can search the exact solutions, and the time performance was shown to be in polynomial time for average cases. The proposed method improved the speed of the structural elucidation of natural products and helped broaden the spectrum of available compounds that could be applied as new drug candidates. A web service built for structural elucidation studies is freely accessible via the following link ( http://csccp.cmdm.tw/ ).
- 2 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 51 (1) , 259-272
A Portable Micro Gas Chromatography System for Lung Cancer Associated Volatile Organic Compound Detection
With the help of micro-electromechanical systems (MEMS) and complementary metal-oxide-semiconductor (CMOS) technology, a portable micro gas chromatography (μGC) system for lung cancer associated volatile organic compounds (VOCs) detection is realized for the first time. The system is composed of an MEMS preconcentrator, an MEMS separation column, and a CMOS system-on-chip (SoC). The preconcentrator provides a concentration ratio of 2170. The separation column can separate more than seven types of lung cancer associated VOCs. The SoC is fabricated by a TSMC 0.35 μm 2P4M process including the CMOS VOCs detector, sensor calibration circuit, low-noise chopper instrumentation amplifier (IA), 10 bit analog to digital converter, and the microcontrol unit (MCU). Experimental results show that the system is able to detect seven types of lung cancer associated VOCs (acetone, 2-butanone, benzene, heptane, toluene, m-xylene, 1,3,5-trimethylbenzene). The concentration linearity is R 2 = 0.985 and the detection sensitivity is up to 15 ppb with 1,3,5-trimethylbenzene.
- 2 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 51 (1) , 259-272
A Portable Micro Gas Chromatography System for Lung Cancer Associated Volatile Organic Compound Detection
With the help of micro-electromechanical systems (MEMS) and complementary metal-oxide-semiconductor (CMOS) technology, a portable micro gas chromatography (μGC) system for lung cancer associated volatile organic compounds (VOCs) detection is realized for the first time. The system is composed of an MEMS preconcentrator, an MEMS separation column, and a CMOS system-on-chip (SoC). The preconcentrator provides a concentration ratio of 2170. The separation column can separate more than seven types of lung cancer associated VOCs. The SoC is fabricated by a TSMC 0.35 μm 2P4M process including the CMOS VOCs detector, sensor calibration circuit, low-noise chopper instrumentation amplifier (IA), 10 bit analog to digital converter, and the microcontrol unit (MCU). Experimental results show that the system is able to detect seven types of lung cancer associated VOCs (acetone, 2-butanone, benzene, heptane, toluene, m-xylene, 1,3,5-trimethylbenzene). The concentration linearity is R 2 = 0.985 and the detection sensitivity is up to 15 ppb with 1,3,5-trimethylbenzene.
- 24 April 2015
- Published by Springer Nature in International Journal of Obesity
- Vol. 39 (8) , 1241-1248
The metabolome profiling and pathway analysis in metabolic healthy and abnormal obesity
Objectives Methods Results Conclusion
- 24 April 2015
- Published by Springer Nature in International Journal of Obesity
- Vol. 39 (8) , 1241-1248
The metabolome profiling and pathway analysis in metabolic healthy and abnormal obesity
Objectives Methods Results Conclusion
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
21.5 A portable micro gas chromatography system for volatile compounds detection with 15ppb of sensitivity
Existing non-invasive lung cancer diagnostic equipment has difficulty in detecting early stage lung cancer as abnormal tissue is smaller than 0.5cm in size. According to studies showing that volatile organic compounds (VOCs) from human breath gas can provide biomarkers for human disease, especially for lung cancer, a non-invasive method was developed to measure the exhaled air from cancer patients using chromatography-mass spectrometry (GC-MS). However, traditional GC-MS equipment is very expensive and requires specialists to operate. In this research we demonstrate a portable micro gas chromatography (μGC) system to overcome the limitations of conventional methods and realize small chips for big data.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
21.5 A portable micro gas chromatography system for volatile compounds detection with 15ppb of sensitivity
Existing non-invasive lung cancer diagnostic equipment has difficulty in detecting early stage lung cancer as abnormal tissue is smaller than 0.5cm in size. According to studies showing that volatile organic compounds (VOCs) from human breath gas can provide biomarkers for human disease, especially for lung cancer, a non-invasive method was developed to measure the exhaled air from cancer patients using chromatography-mass spectrometry (GC-MS). However, traditional GC-MS equipment is very expensive and requires specialists to operate. In this research we demonstrate a portable micro gas chromatography (μGC) system to overcome the limitations of conventional methods and realize small chips for big data.