Yessine Amri
Research Subjects
Yessine Amri has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Taieb Messaoud
Biochemistry Laboratory (LR00SP03), Bechir Hamza Children's Hospital, Tunis, Tunisia; Faculty of Pharmacy of Monastir, University of Monastir, Monastir, Tunisia
12 shared publicationsRym Dabboubi
Biochemistry Laboratory (LR00SP03), Bechir Hamza Children's Hospital, Tunis, Tunisia; Faculty of Pharmacy of Monastir, University of Monastir, Monastir, Tunisia
10 shared publicationsSondess Hadj Fredj
Biochemistry Laboratory (LR00SP03), Bechir Hamza Children's Hospital, Tunis, Tunisia
9 shared publicationsAmine Ben Slama
5 shared publicationsChaima Sahli
Biochemistry Laboratory (LR00SP03), Bechir Hamza Children’s Hospital, Tunis, Tunisia
4 shared publicationsHedi Trabelsi
4 shared publications
Latest Publications
- Open Access
- 8 April 2026
- Published by Elsevier in Scientific African
- Vol. 32
Integrative biochemical and in silico characterization of congenital bisalbuminemia and its impact on albumin structure and ligand transport
- 8 April 2026
- Published by Elsevier in Scientific African
- Vol. 32
Open AccessIntegrative biochemical and in silico characterization of congenital bisalbuminemia and its impact on albumin structure and ligand transport
- Open Access
- 18 November 2025
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 11 (1) , 48-60
Discrepancies in Sigma Metrics Driven by Total Allowable Error Variability: Implications for QC Strategy and Laboratory Efficiency
Background: Sigma methodology has become a valuable tool in clinical laboratories for assessing analytical performance and optimizing QC. However, the choice of total allowable error (TEa) sources significantly influences sigma calculation outcomes and can lead to inconsistent quality classifications. In this study, we aimed to evaluate how different TEa guidelines impact sigma metrics and internal quality control (IQC) strategies in order to highlight the need for harmonization in TEa selection. Methods: A prospective observational study was conducted over 3 months (April–June 2025) in the Clinical Biochemistry Laboratory at Bechir Hamza Children’s Hospital. Sigma metrics were calculated for 14 routine analytes at 2 QC levels (level 1 and level 2) using internal and external QC data. Three TEa sources were used: CLIA 2025 (regulatory-based), Randox International Quality Assessment Scheme (RIQAS; peer group-based), and European Federation of Laboratory Medicine (EFLM; biological variation-based). IQC procedures were adapted based on Westgard sigma rules and flowcharts. Results: Substantial variability in sigma metrics was observed across the 3 TEa guidelines. The same analyte could be classified as “world-class” under EFLM but “unacceptable” under RIQAS. Electrolytes (sodium, potassium, chloride) consistently exhibited poor performance across all guidelines. Visual tools, including radar and sigma charts, confirmed discrepancies. These differences significantly influenced the selection and complexity of IQC procedures. Conclusions: The choice of TEa guideline exerts a critical influence on sigma metrics and subsequent IQC planning. Current inconsistencies highlight the urgent need for standardized TEa criteria that are both clinically meaningful and practically achievable. Harmonization would improve comparability, optimize laboratory resources, and support evidence-based quality management in clinical laboratories.
- 18 November 2025
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 11 (1) , 48-60
Open AccessDiscrepancies in Sigma Metrics Driven by Total Allowable Error Variability: Implications for QC Strategy and Laboratory Efficiency
Background: Sigma methodology has become a valuable tool in clinical laboratories for assessing analytical performance and optimizing QC. However, the choice of total allowable error (TEa) sources significantly influences sigma calculation outcomes and can lead to inconsistent quality classifications. In this study, we aimed to evaluate how different TEa guidelines impact sigma metrics and internal quality control (IQC) strategies in order to highlight the need for harmonization in TEa selection. Methods: A prospective observational study was conducted over 3 months (April–June 2025) in the Clinical Biochemistry Laboratory at Bechir Hamza Children’s Hospital. Sigma metrics were calculated for 14 routine analytes at 2 QC levels (level 1 and level 2) using internal and external QC data. Three TEa sources were used: CLIA 2025 (regulatory-based), Randox International Quality Assessment Scheme (RIQAS; peer group-based), and European Federation of Laboratory Medicine (EFLM; biological variation-based). IQC procedures were adapted based on Westgard sigma rules and flowcharts. Results: Substantial variability in sigma metrics was observed across the 3 TEa guidelines. The same analyte could be classified as “world-class” under EFLM but “unacceptable” under RIQAS. Electrolytes (sodium, potassium, chloride) consistently exhibited poor performance across all guidelines. Visual tools, including radar and sigma charts, confirmed discrepancies. These differences significantly influenced the selection and complexity of IQC procedures. Conclusions: The choice of TEa guideline exerts a critical influence on sigma metrics and subsequent IQC planning. Current inconsistencies highlight the urgent need for standardized TEa criteria that are both clinically meaningful and practically achievable. Harmonization would improve comparability, optimize laboratory resources, and support evidence-based quality management in clinical laboratories.
- Open Access
- 1 September 2025
- Published by KEAI Publishing in Journal of Electronic Science and Technology
- Vol. 23 (3)
Automated ECG arrhythmia classification using hybrid CNN-SVM architectures
- 1 September 2025
- Published by KEAI Publishing in Journal of Electronic Science and Technology
- Vol. 23 (3)
Open AccessAutomated ECG arrhythmia classification using hybrid CNN-SVM architectures
- Open Access
- 28 August 2025
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 31 (3) , 178-194
Lung diseases classification using pre-trained based deep learning model and support vector machine
Introduction: Given its rapid transmission and heightened fatality rate, early detection of viral pneumonia is imperative. The virus mainly affects the lung, leading to pneumonia alongside symptoms like fatigue, dry cough, and fever, which can sometimes be misdiagnosed as other respiratory conditions such as lung cancer or pneumonia. Chest X-rays are widely used in the healthcare sector to provide both swift and accurate diagnoses. Deep learning algorithms have demonstrated significant efficiency in detecting and classifying lung diseases, which enhanced the diagnostic process and saving valuable time for medical applications and therapy.The objective of this study is to develop and evaluate a deep learning-based architecture for the accurate multi-class classification of respiratory diseases, including pneumonia, lung opacity, and COVID-19, using chest X-ray images to enhance diagnostic efficiency in healthcare settings. Material and methods: A substantial dataset comprising X-ray images was crated, including 1026 pneumonia cases, 1256 COVID-19 cases, 2305 lung opacity cases and 3224 normal X-ray images. For classification purposes, we employed a pre-trained VGG19 model combined with an SVM classifier. To validate the model’s accuracy, we utilized cross-validation techniques and performance metrics, including precision, recall, F1-score, and the area under the curve (AUC). This approach ensures robust evaluation of the proposed framework. Results: The experimental results demonstrated the superiority of our proposed VGG16+SVM model over existing approaches, achieving an accuracy of 93.50%, recall of 94.16%, precision of 94.45%, F1 score of 93.28%, and area under the curve (AUC) of 90.16%. Conclusions: This enhanced performance equips healthcare practitioners with the tools to diagnose and treat patients more expeditiously and effectively.
- 28 August 2025
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 31 (3) , 178-194
Open AccessLung diseases classification using pre-trained based deep learning model and support vector machine
Introduction: Given its rapid transmission and heightened fatality rate, early detection of viral pneumonia is imperative. The virus mainly affects the lung, leading to pneumonia alongside symptoms like fatigue, dry cough, and fever, which can sometimes be misdiagnosed as other respiratory conditions such as lung cancer or pneumonia. Chest X-rays are widely used in the healthcare sector to provide both swift and accurate diagnoses. Deep learning algorithms have demonstrated significant efficiency in detecting and classifying lung diseases, which enhanced the diagnostic process and saving valuable time for medical applications and therapy.The objective of this study is to develop and evaluate a deep learning-based architecture for the accurate multi-class classification of respiratory diseases, including pneumonia, lung opacity, and COVID-19, using chest X-ray images to enhance diagnostic efficiency in healthcare settings. Material and methods: A substantial dataset comprising X-ray images was crated, including 1026 pneumonia cases, 1256 COVID-19 cases, 2305 lung opacity cases and 3224 normal X-ray images. For classification purposes, we employed a pre-trained VGG19 model combined with an SVM classifier. To validate the model’s accuracy, we utilized cross-validation techniques and performance metrics, including precision, recall, F1-score, and the area under the curve (AUC). This approach ensures robust evaluation of the proposed framework. Results: The experimental results demonstrated the superiority of our proposed VGG16+SVM model over existing approaches, achieving an accuracy of 93.50%, recall of 94.16%, precision of 94.45%, F1 score of 93.28%, and area under the curve (AUC) of 90.16%. Conclusions: This enhanced performance equips healthcare practitioners with the tools to diagnose and treat patients more expeditiously and effectively.
- Open Access
- 9 June 2025
- Published by Springer Nature in Annals of Hematology
- Vol. 104 (6) , 3173-3182
Revealing silent alpha-thalassemia: characterization of novel HBA1 deletion and missense mutation in Tunisian families
Alpha-thalassemia is a common inherited hemoglobin disorder caused by deletions or point mutations in the HBA1 and/or HBA2 genes, leading to reduced or absent synthesis of alpha-globin chains. Although deletional mutations are predominant, non-deletional mutations can also contribute to the clinical spectrum of the disease, with varying severity. This study aimed to characterize two novel mutations in the HBA1 gene, a 230 bp microdeletion and a missense mutation (NP_000549.1:p.Ala29Pro), identified in two unrelated Tunisian families. Additionally, we assessed the clinical, hematological, molecular, and in silico structural impact of these mutations. Peripheral blood samples were collected from affected individuals and family members. Hematological parameters were measured using automated cell counters, and hemoglobin fractions were analyzed by high-performance liquid chromatography (HPLC). Genomic DNA was extracted, and common α-thalassemia deletions were screened via gap-PCR. Negative cases underwent sequencing of HBA1 and HBA2 exons. The novel deletion was confirmed by gap-PCR, gel purification, and sequencing. The pathogenicity of the missense mutation was assessed using in silico tools (PolyPhen-2, SIFT, MutationTaster), and structural modeling was performed using Swiss-PdbViewer and DynaMut to evaluate protein stability and flexibility. In Family A, a 4-year-old proband exhibited mild anemia, microcytosis, hypochromia, and low ferritin levels unresponsive to iron supplementation. A novel heterozygous 230 bp deletion (NC_000016.10:g.176695_176925del), named Hemoglobin Ariana, was identified in the HBA1 gene, affecting the 5’UTR, exon 1, and part of intron 1. In Family B, a 4-month-old proband presented with co-inheritance of α-thalassemia and Hemoglobin C. Sequencing revealed a novel missense mutation (NM_000558.5:c.85G > C, NP_000549.1:p.Ala29Pro), designated Hemoglobin Tozeur. In silico analysis predicted the mutation as deleterious, with structural modeling indicating destabilization of the α-globin protein, reduced stability, and altered flexibility near the heme-binding region. This study identifies two novel HBA1 mutations associated with α-thalassemia in Tunisia. The combined clinical, molecular, and structural analyses highlight the importance of comprehensive genetic screening and in silico modeling for accurate diagnosis and improved management of thalassemia cases.
- 9 June 2025
- Published by Springer Nature in Annals of Hematology
- Vol. 104 (6) , 3173-3182
Open AccessRevealing silent alpha-thalassemia: characterization of novel HBA1 deletion and missense mutation in Tunisian families
Alpha-thalassemia is a common inherited hemoglobin disorder caused by deletions or point mutations in the HBA1 and/or HBA2 genes, leading to reduced or absent synthesis of alpha-globin chains. Although deletional mutations are predominant, non-deletional mutations can also contribute to the clinical spectrum of the disease, with varying severity. This study aimed to characterize two novel mutations in the HBA1 gene, a 230 bp microdeletion and a missense mutation (NP_000549.1:p.Ala29Pro), identified in two unrelated Tunisian families. Additionally, we assessed the clinical, hematological, molecular, and in silico structural impact of these mutations. Peripheral blood samples were collected from affected individuals and family members. Hematological parameters were measured using automated cell counters, and hemoglobin fractions were analyzed by high-performance liquid chromatography (HPLC). Genomic DNA was extracted, and common α-thalassemia deletions were screened via gap-PCR. Negative cases underwent sequencing of HBA1 and HBA2 exons. The novel deletion was confirmed by gap-PCR, gel purification, and sequencing. The pathogenicity of the missense mutation was assessed using in silico tools (PolyPhen-2, SIFT, MutationTaster), and structural modeling was performed using Swiss-PdbViewer and DynaMut to evaluate protein stability and flexibility. In Family A, a 4-year-old proband exhibited mild anemia, microcytosis, hypochromia, and low ferritin levels unresponsive to iron supplementation. A novel heterozygous 230 bp deletion (NC_000016.10:g.176695_176925del), named Hemoglobin Ariana, was identified in the HBA1 gene, affecting the 5’UTR, exon 1, and part of intron 1. In Family B, a 4-month-old proband presented with co-inheritance of α-thalassemia and Hemoglobin C. Sequencing revealed a novel missense mutation (NM_000558.5:c.85G > C, NP_000549.1:p.Ala29Pro), designated Hemoglobin Tozeur. In silico analysis predicted the mutation as deleterious, with structural modeling indicating destabilization of the α-globin protein, reduced stability, and altered flexibility near the heme-binding region. This study identifies two novel HBA1 mutations associated with α-thalassemia in Tunisia. The combined clinical, molecular, and structural analyses highlight the importance of comprehensive genetic screening and in silico modeling for accurate diagnosis and improved management of thalassemia cases.
- Open Access
- 27 May 2025
- Published by Springer Nature in BMC Medical Genomics
- Vol. 18 (1) , 1-13
Comprehensive analysis of a novel LYST mutation in a Tunisian patient with Chediak-Higashi syndrome
Chediak-Higashi Syndrome (CHS) is a rare autosomal recessive disorder characterized by oculocutaneous albinism, recurrent infections, bleeding tendencies, and progressive neurological impairment. The syndrome is caused by mutations in the LYST gene, which plays a crucial role in lysosomal trafficking. This study aims to characterize the molecular basis of CHS in a Tunisian patient by identifying mutations in the LYST gene and analyzing their impact on the protein function, correlating these findings with the patient’s clinical presentation. A comprehensive clinical assessment was conducted on the patient, followed by biochemical, hematological, and microbiological analyses. Additionally, LYST protein levels were quantified in the patient and their parents using an ELISA assay. Genomic DNA was extracted from the patient’s blood, and Whole Exome Sequencing (WES) was performed to identify mutations in the LYST gene. The findings were confirmed through Sanger sequencing, and bioinformatic tools were employed to predict the functional consequences of the detected mutations. The patient presented with classical symptoms of CHS, including silver hair, hypopigmented skin, recurrent infections, and neurological decline, with an unusually late onset at 18 years. ELISA results demonstrated significantly reduced LYST levels in the patient (1.8 ng/ml) compared to heterozygous parents (7.8 ng/ml and 8.1 ng/ml) and controls (9.2 ng/ml). Genetic analysis revealed a novel homozygous deletion, c.10269_10275del (p.Gly3424SerfsTer15), in the LYST gene, leading to a frameshift mutation and premature termination of the protein. Bioinformatic analysis demonstrated that this mutation leads to the deletion of five out of sven WD40 repeats in the protein’s C-terminal region, which are critical for protein-protein interactions and lysosomal trafficking. The study identifies a novel LYST mutation in a Tunisian patient with CHS, expanding the spectrum of known genetic variants associated with the disease. The findings highlight the importance of genetic screening in populations with high consanguinity and underscore the need for targeted therapies to address the molecular defects in CHS.
- 27 May 2025
- Published by Springer Nature in BMC Medical Genomics
- Vol. 18 (1) , 1-13
Open AccessComprehensive analysis of a novel LYST mutation in a Tunisian patient with Chediak-Higashi syndrome
Chediak-Higashi Syndrome (CHS) is a rare autosomal recessive disorder characterized by oculocutaneous albinism, recurrent infections, bleeding tendencies, and progressive neurological impairment. The syndrome is caused by mutations in the LYST gene, which plays a crucial role in lysosomal trafficking. This study aims to characterize the molecular basis of CHS in a Tunisian patient by identifying mutations in the LYST gene and analyzing their impact on the protein function, correlating these findings with the patient’s clinical presentation. A comprehensive clinical assessment was conducted on the patient, followed by biochemical, hematological, and microbiological analyses. Additionally, LYST protein levels were quantified in the patient and their parents using an ELISA assay. Genomic DNA was extracted from the patient’s blood, and Whole Exome Sequencing (WES) was performed to identify mutations in the LYST gene. The findings were confirmed through Sanger sequencing, and bioinformatic tools were employed to predict the functional consequences of the detected mutations. The patient presented with classical symptoms of CHS, including silver hair, hypopigmented skin, recurrent infections, and neurological decline, with an unusually late onset at 18 years. ELISA results demonstrated significantly reduced LYST levels in the patient (1.8 ng/ml) compared to heterozygous parents (7.8 ng/ml and 8.1 ng/ml) and controls (9.2 ng/ml). Genetic analysis revealed a novel homozygous deletion, c.10269_10275del (p.Gly3424SerfsTer15), in the LYST gene, leading to a frameshift mutation and premature termination of the protein. Bioinformatic analysis demonstrated that this mutation leads to the deletion of five out of sven WD40 repeats in the protein’s C-terminal region, which are critical for protein-protein interactions and lysosomal trafficking. The study identifies a novel LYST mutation in a Tunisian patient with CHS, expanding the spectrum of known genetic variants associated with the disease. The findings highlight the importance of genetic screening in populations with high consanguinity and underscore the need for targeted therapies to address the molecular defects in CHS.
- Open Access
- 2 May 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (3) , 1901-1911
Artificial intelligence in vestibular disorder diagnosis
Vertigo is a prevalent symptom of vestibular disorders, with ocular nystagmus analysis serving as a key indicator for distinguishing between peripheral and central vestibular conditions. Videonystagmography (VNG) provides objective and reliable measurements, making it a valuable tool for clinical assessments. However, the complexity and variability of vestibular diseases pose challenges for conventional VNG methods, such as caloric, kinetic, and saccadic tests, in accurately identifying vertigo subtypes. Traditional diagnostic approaches often fail to fully utilize nystagmus characteristics in correlating with specific vestibular disorders, limiting their effectiveness. Recent advancements in artificial intelligence (AI), particularly deep learning and machine learning (ML), offer promising solutions for improving vertigo diagnosis. These technologies facilitate automated, rapid, and precise analysis by extracting relevant clinical features and classifying vestibular disorders with higher accuracy. ML-based models enhance diagnostic reliability, reducing human bias and subjectivity in assessment. This study reviews the latest research on feature extraction and ML applications in vertigo diagnosis, emphasizing their potential to revolutionize clinical decision-making. It aims to provide a comprehensive understanding of AI-driven approaches and their role in advancing vertigo analysis, paving the way for more effective diagnostic methodologies in the future.
- 2 May 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (3) , 1901-1911
Open AccessArtificial intelligence in vestibular disorder diagnosis
Vertigo is a prevalent symptom of vestibular disorders, with ocular nystagmus analysis serving as a key indicator for distinguishing between peripheral and central vestibular conditions. Videonystagmography (VNG) provides objective and reliable measurements, making it a valuable tool for clinical assessments. However, the complexity and variability of vestibular diseases pose challenges for conventional VNG methods, such as caloric, kinetic, and saccadic tests, in accurately identifying vertigo subtypes. Traditional diagnostic approaches often fail to fully utilize nystagmus characteristics in correlating with specific vestibular disorders, limiting their effectiveness. Recent advancements in artificial intelligence (AI), particularly deep learning and machine learning (ML), offer promising solutions for improving vertigo diagnosis. These technologies facilitate automated, rapid, and precise analysis by extracting relevant clinical features and classifying vestibular disorders with higher accuracy. ML-based models enhance diagnostic reliability, reducing human bias and subjectivity in assessment. This study reviews the latest research on feature extraction and ML applications in vertigo diagnosis, emphasizing their potential to revolutionize clinical decision-making. It aims to provide a comprehensive understanding of AI-driven approaches and their role in advancing vertigo analysis, paving the way for more effective diagnostic methodologies in the future.
- Open Access
- 19 April 2025
- Published by Elsevier in Molecular Genetics and Metabolism Reports
- Vol. 43, 101222
Genetic variations in the IDUA gene in Tunisian MPS I families: Identification of a novel microdeletion disrupting substrate binding and structural insights
- 19 April 2025
- Published by Elsevier in Molecular Genetics and Metabolism Reports
- Vol. 43, 101222
Open AccessGenetic variations in the IDUA gene in Tunisian MPS I families: Identification of a novel microdeletion disrupting substrate binding and structural insights