Frank E. Talke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frank E. Talke has a total of 126 co-authors. Here are the top co-authors by number of shared publications:
- Phuong Truong
University of California San Diego, La Jolla, CA
5 shared publications - Raymond A. de Callafon
Mechanical and Aerospace Engineering Department, University of California San Diego, 9500 Gilman Dr., San Diego, CA 92092, USA
5 shared publications - Alex Phan
University of California, San Diego - La Jolla, CA, USA
4 shared publications - Uwe Boettcher
University of California, San Diego
4 shared publications Alex Phan
Center for Memory and Recording Research, University of California, La Jolla, USA
3 shared publications- Bernhard Knigge
Western Digital Corporation
3 shared publications
Latest Publications
- Open Access
Computer Navigated Spinal Surgery Using Magnetic Resonance Imaging and Augmented Reality
Current spinal pain management procedures, such as radiofrequency ablation (RFA) and epidural steroid injection (ESI), rely on fluoroscopy for needle placement which exposes patients and physicians to ionizing radiation. In this paper, we investigate a radiation-free surgical navigation system for spinal pain management procedures that combines magnetic resonance imaging (MRI) with fiducial ArUco marker-based augmented reality (AR). High-resolution MRI scans of a lumbar spinal phantom were obtained and assembled as a surface mesh. Laplacian smoothing algorithms were then applied to smoothen the surface and improve the model fidelity. A commercially available stereo camera (ZED2) was used to track single or dual fiducial ArUco markers on the patient to determine the patient's real-time pose. Custom AR software was applied to overlay the MRI image onto the patient, allowing the physician to see not only the outer surface of the patient but also the complete anatomy of the patient below the surface. Needle-insertion trials on a 3D-printed 3-vertebra phantom showed that dual-ArUco marker tracking increased the accuracy of needle insertions and reduced the average needle misplacement distance compared to single-ArUco marker procedures. The average needle misplacement is comparable to the average deviation of 2 mm for conventional epidural techniques using fluoroscopy. Our radiation-free system demonstrates promise to serve as an alternative to fluoroscopy by improving image-guided spinal navigation.
Open AccessComputer Navigated Spinal Surgery Using Magnetic Resonance Imaging and Augmented Reality
Current spinal pain management procedures, such as radiofrequency ablation (RFA) and epidural steroid injection (ESI), rely on fluoroscopy for needle placement which exposes patients and physicians to ionizing radiation. In this paper, we investigate a radiation-free surgical navigation system for spinal pain management procedures that combines magnetic resonance imaging (MRI) with fiducial ArUco marker-based augmented reality (AR). High-resolution MRI scans of a lumbar spinal phantom were obtained and assembled as a surface mesh. Laplacian smoothing algorithms were then applied to smoothen the surface and improve the model fidelity. A commercially available stereo camera (ZED2) was used to track single or dual fiducial ArUco markers on the patient to determine the patient's real-time pose. Custom AR software was applied to overlay the MRI image onto the patient, allowing the physician to see not only the outer surface of the patient but also the complete anatomy of the patient below the surface. Needle-insertion trials on a 3D-printed 3-vertebra phantom showed that dual-ArUco marker tracking increased the accuracy of needle insertions and reduced the average needle misplacement distance compared to single-ArUco marker procedures. The average needle misplacement is comparable to the average deviation of 2 mm for conventional epidural techniques using fluoroscopy. Our radiation-free system demonstrates promise to serve as an alternative to fluoroscopy by improving image-guided spinal navigation.
- Open Access
- 28 May 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (5) , 1137-1145
A low-cost, open-source-based optical surgical navigation system using stereoscopic vision
Computer-assisted surgical navigation systems have gained popularity in surgical procedures that demand high amounts of precision. These systems aim to track the real-time positioning of surgical instruments in relation to anatomical structures. Typically, state-of-the-art methods involve tracking reflective 3D marker spheres affixed to both surgical instruments and patient anatomies with infrared cameras. However, these setups are expensive and financially impractical for small healthcare facilities. This study suggests that a fully optical navigation approach utilizing low-cost, off-the-shelf parts may become a viable alternative. We develop a stereoscopic camera setup, costing around $120, to track and monitor the translational movement of open-source based fiducial markers on a positioning platform. We evaluate the camera setup based on its reliability and accuracy. Using the optimal set of parameters, we were able to produce a root mean square error of 2 mm. These results demonstrate the feasibility of real-time, cost-effective surgical navigation using off-the-shelf optical cameras.
- 28 May 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (5) , 1137-1145
Open AccessA low-cost, open-source-based optical surgical navigation system using stereoscopic vision
Computer-assisted surgical navigation systems have gained popularity in surgical procedures that demand high amounts of precision. These systems aim to track the real-time positioning of surgical instruments in relation to anatomical structures. Typically, state-of-the-art methods involve tracking reflective 3D marker spheres affixed to both surgical instruments and patient anatomies with infrared cameras. However, these setups are expensive and financially impractical for small healthcare facilities. This study suggests that a fully optical navigation approach utilizing low-cost, off-the-shelf parts may become a viable alternative. We develop a stereoscopic camera setup, costing around $120, to track and monitor the translational movement of open-source based fiducial markers on a positioning platform. We evaluate the camera setup based on its reliability and accuracy. Using the optimal set of parameters, we were able to produce a root mean square error of 2 mm. These results demonstrate the feasibility of real-time, cost-effective surgical navigation using off-the-shelf optical cameras.
- Open Access
- 1 April 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (6) , 751-760
Design of a detachable bronchoscope for endotracheal intubation
A novel detachable bronchoscope with a 3D printed micro-transmission is investigated. The micro-transmission controls the motion of the tip of the bronchoscope and is embedded in one end of the flexible insertion section of the bronchoscope. The micro-transmission allows manipulation of the distal end through the translation of guide nuts that are connected to the tip of the bronchoscope through so-called “angulation” wires. The displacement of the guide nuts on the left and right-handed screw sections and the control of the distal end of the bronchoscope are investigated. The maximum tensile force on the angulation wire before failure is determined experimentally for different screw pitches.
- 1 April 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 30 (6) , 751-760
Open AccessDesign of a detachable bronchoscope for endotracheal intubation
A novel detachable bronchoscope with a 3D printed micro-transmission is investigated. The micro-transmission controls the motion of the tip of the bronchoscope and is embedded in one end of the flexible insertion section of the bronchoscope. The micro-transmission allows manipulation of the distal end through the translation of guide nuts that are connected to the tip of the bronchoscope through so-called “angulation” wires. The displacement of the guide nuts on the left and right-handed screw sections and the control of the distal end of the bronchoscope are investigated. The maximum tensile force on the angulation wire before failure is determined experimentally for different screw pitches.
- Open Access
Design and Material Characterization of an Inflatable Vaginal Dilator
There are more than 13,000 new cases of cervical cancer each year in the United States and approximately 245,000 survivors. External beam radiation and brachytherapy are the front-line treatment modalities, and 60% of patients develop vaginal damage and constriction, i.e., stenosis of the vaginal vault, greatly impeding sexual function. The incidence of vaginal stenosis (VS) following radiotherapy (RT) for anorectal cancer is 80%. VS causes serious quality of life (QoL) and psychological issues, and while standard treatment using self-administered plastic dilators is effective, acceptance and compliance are often insufficient. Based on published patient preferences, we have pursued the design of a soft inflatable dilator for treating radiotherapy-induced vaginal stenosis (VS). The critical component of the novel device is the dilator balloon wall material, which must be compliant yet able to exert therapeutic lateral force levels. We selected a commercially available silicone elastomer and characterized its stress–strain characteristics and hyperelastic properties. These parameters were quantified using uniaxial tensile testing and digital image correlation (DIC). Dilator inflation versus internal pressure was modeled and experimentally validated in order to characterize design parameters, particularly the dilator wall thickness. Our data suggest that an inflatable silicone elastomer-based vaginal dilator warrants further development in the context of a commercially available, well-tolerated, and effective device for the graded, controlled clinical management of radiotherapy-induced VS.
Open AccessDesign and Material Characterization of an Inflatable Vaginal Dilator
There are more than 13,000 new cases of cervical cancer each year in the United States and approximately 245,000 survivors. External beam radiation and brachytherapy are the front-line treatment modalities, and 60% of patients develop vaginal damage and constriction, i.e., stenosis of the vaginal vault, greatly impeding sexual function. The incidence of vaginal stenosis (VS) following radiotherapy (RT) for anorectal cancer is 80%. VS causes serious quality of life (QoL) and psychological issues, and while standard treatment using self-administered plastic dilators is effective, acceptance and compliance are often insufficient. Based on published patient preferences, we have pursued the design of a soft inflatable dilator for treating radiotherapy-induced vaginal stenosis (VS). The critical component of the novel device is the dilator balloon wall material, which must be compliant yet able to exert therapeutic lateral force levels. We selected a commercially available silicone elastomer and characterized its stress–strain characteristics and hyperelastic properties. These parameters were quantified using uniaxial tensile testing and digital image correlation (DIC). Dilator inflation versus internal pressure was modeled and experimentally validated in order to characterize design parameters, particularly the dilator wall thickness. Our data suggest that an inflatable silicone elastomer-based vaginal dilator warrants further development in the context of a commercially available, well-tolerated, and effective device for the graded, controlled clinical management of radiotherapy-induced VS.
- Open Access
- 1 January 2024
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 11, 44-50
Enhancing Minimally Invasive Spinal Procedures Through Computer Vision and Augmented Reality Techniques
Volume 11, Issue 1 published for JBEB Journal.
- 1 January 2024
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 11, 44-50
Open AccessEnhancing Minimally Invasive Spinal Procedures Through Computer Vision and Augmented Reality Techniques
Volume 11, Issue 1 published for JBEB Journal.
- Open Access
- 1 January 2024
- Published by Springer Nature in Research Square
A Low-Cost, Open-Source-based Optical Surgical Navigation System Using Stereoscopic Vision
Computer-assisted surgical navigation systems have gained popularity in surgical procedures that demand high amounts of precision. These systems aim to track the real-time positioning of surgical instruments in relation to anatomical structures. Typically, state-of-the-art methods involve tracking reflective 3D marker spheres affixed to both surgical instruments and patient anatomies with infrared cameras. However, these setups are expensive and financially impractical for small healthcare facilities. This study suggests that a fully optical navigation approach utilizing low-cost, off-the-shelf parts may become a viable alternative. We develop a stereoscopic camera setup, costing around $120, to track and monitor the translational movement of open-source based fiducial markers on a positioning platform. We evaluate the camera setup based on its reliability and accuracy. Using the optimal set of parameters, we were able to produce a root mean square error of 2 mm. These results demonstrate the feasibility of real-time, cost-effective surgical navigation using off-the-shelf optical cameras.
- 1 January 2024
- Published by Springer Nature in Research Square
Open AccessA Low-Cost, Open-Source-based Optical Surgical Navigation System Using Stereoscopic Vision
Computer-assisted surgical navigation systems have gained popularity in surgical procedures that demand high amounts of precision. These systems aim to track the real-time positioning of surgical instruments in relation to anatomical structures. Typically, state-of-the-art methods involve tracking reflective 3D marker spheres affixed to both surgical instruments and patient anatomies with infrared cameras. However, these setups are expensive and financially impractical for small healthcare facilities. This study suggests that a fully optical navigation approach utilizing low-cost, off-the-shelf parts may become a viable alternative. We develop a stereoscopic camera setup, costing around $120, to track and monitor the translational movement of open-source based fiducial markers on a positioning platform. We evaluate the camera setup based on its reliability and accuracy. Using the optimal set of parameters, we were able to produce a root mean square error of 2 mm. These results demonstrate the feasibility of real-time, cost-effective surgical navigation using off-the-shelf optical cameras.
- Open Access
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Journal of Advanced Mechanical Design, Systems, and Manufacturing
- Vol. 17 (4) , JAMDSM0047
A portable multifunctional ophthalmic device for remote self-examination of the eye
This paper presents the design of a new portable ophthalmic device, the so-called 3-in-1 device, that allows patients to self-examine their eyes. The device combines the three most essential ophthalmic examinations: slit lamp biomicroscopy to examine the anterior segment of the eye, visual acuity measurement to determine the quality of vision, and non-contact tonometry to assess the intraocular pressure of the eye. The aim of the device is to enable the patient to perform these standard examinations in the comfort of his home and to send the results via the internet to the ophthalmologist for further evaluation. Within the scope of this work, the first prototype of the 3-in-1 device was designed and manufactured. The slit lamp examination procedure can be recorded by a video camera and the footage can be used by an ophthalmologist to check for abnormalities in the anterior chamber of the eye. The visual acuity screener has been designed to be performed under the same conditions as a conventional visual acuity examination by an ophthalmologist. For this function an optical lens system was developed which projects the optotypes to a test distance of 6m. The non-contact tonometer evaluates the degree of deformation of the patient's cornea using machine learning algorithms to draw conclusions about the intraocular pressure. Ultimately, the goal of the device is to improve accessibility to ophthalmic care and the frequency with which examinations are performed in order to detect eye diseases and abnormalities earlier.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Journal of Advanced Mechanical Design, Systems, and Manufacturing
- Vol. 17 (4) , JAMDSM0047
Open AccessA portable multifunctional ophthalmic device for remote self-examination of the eye
This paper presents the design of a new portable ophthalmic device, the so-called 3-in-1 device, that allows patients to self-examine their eyes. The device combines the three most essential ophthalmic examinations: slit lamp biomicroscopy to examine the anterior segment of the eye, visual acuity measurement to determine the quality of vision, and non-contact tonometry to assess the intraocular pressure of the eye. The aim of the device is to enable the patient to perform these standard examinations in the comfort of his home and to send the results via the internet to the ophthalmologist for further evaluation. Within the scope of this work, the first prototype of the 3-in-1 device was designed and manufactured. The slit lamp examination procedure can be recorded by a video camera and the footage can be used by an ophthalmologist to check for abnormalities in the anterior chamber of the eye. The visual acuity screener has been designed to be performed under the same conditions as a conventional visual acuity examination by an ophthalmologist. For this function an optical lens system was developed which projects the optotypes to a test distance of 6m. The non-contact tonometer evaluates the degree of deformation of the patient's cornea using machine learning algorithms to draw conclusions about the intraocular pressure. Ultimately, the goal of the device is to improve accessibility to ophthalmic care and the frequency with which examinations are performed in order to detect eye diseases and abnormalities earlier.
- 21 January 2021
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 35 (8) , 1071-1081
A comparative study of experimental urinary catheters containing silver and zinc for biofilm inhibition
Both commercial and experimental antibacterial urinary catheters were investigated for their efficacy in preventing planktonic growth and biofilm formation of Escherichia Coli bacteria in a synthetic urine solution. Experimental antibacterial catheters having thin (2O, or Zn/Ag2O in polydimethylsiloxane (PDMS) binder all exhibited significant antimicrobial activity, outperforming traditional commercial antibacterial catheters. All experimental catheters prevented planktonic growth of bacteria and did not exhibit biofilm formation during a six-day test period using a colony forming unit (CFU) measurement method. On the other hand, the best performing commercial catheters demonstrated efficacy for only 3 days in planktonic growth tests and formed multiple bacterial colonies in CFU measurements. The Zn/Ag2O/PDMS experimental catheter was the only catheter observed to produce hydrogen peroxide, a reactive oxygen species known to inhibit biofilm formation; lack of detectable hydrogen peroxide production by the Ag2O/PDMS and Ag/Ag2O/PDMS experimental catheters suggests that bactericidal action most likely arises from release of silver ions present in the PDMS coatings.
- 21 January 2021
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 35 (8) , 1071-1081
A comparative study of experimental urinary catheters containing silver and zinc for biofilm inhibition
Both commercial and experimental antibacterial urinary catheters were investigated for their efficacy in preventing planktonic growth and biofilm formation of Escherichia Coli bacteria in a synthetic urine solution. Experimental antibacterial catheters having thin (2O, or Zn/Ag2O in polydimethylsiloxane (PDMS) binder all exhibited significant antimicrobial activity, outperforming traditional commercial antibacterial catheters. All experimental catheters prevented planktonic growth of bacteria and did not exhibit biofilm formation during a six-day test period using a colony forming unit (CFU) measurement method. On the other hand, the best performing commercial catheters demonstrated efficacy for only 3 days in planktonic growth tests and formed multiple bacterial colonies in CFU measurements. The Zn/Ag2O/PDMS experimental catheter was the only catheter observed to produce hydrogen peroxide, a reactive oxygen species known to inhibit biofilm formation; lack of detectable hydrogen peroxide production by the Ag2O/PDMS and Ag/Ag2O/PDMS experimental catheters suggests that bactericidal action most likely arises from release of silver ions present in the PDMS coatings.
- 3 January 2021
- Published by Springer Nature in Microsystem Technologies
- Vol. 27 (6) , 2473-2479
Investigation of long term drift of an intraocular pressure sensor
- 3 January 2021
- Published by Springer Nature in Microsystem Technologies
- Vol. 27 (6) , 2473-2479
Investigation of long term drift of an intraocular pressure sensor
- Open Access
- 1 January 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 10, 339-348
Investigation of an improved electricidal coating for inhibiting biofilm formation on urinary catheters
- 1 January 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 10, 339-348
Open AccessInvestigation of an improved electricidal coating for inhibiting biofilm formation on urinary catheters