Andres Mena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andres Mena has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
M. Doblaré
Group of Structural Mechanics and Materials Modelling, University of Zaragoza, Zaragoza, Spain; Aragón Institute of Engineering Research, University of Zaragoza, Zaragoza, Spain; The Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), C/ Maria de Luna 11, 50018 Zaragoza, Spain
6 shared publicationsA. Ginel
Hospital Virgen del Rocío, Department of Thoracic Surgery, Seville, Spain
4 shared publications- Amaya Perez del Palomar
Biomaterials Group, Aragon Engineering Research Institute (I3A), University of Zaragoza, 50018 Zaragoza, Spain
4 shared publications - Olfa Trabelsi
Université de Technologie de Compiègne, Biomechanics and Bioengineering UMR CNRS 7338, Centre de Recherche Royallieu, CS 60 319, 60 203 Compiègne Cedex, France
4 shared publications - Agustín Vidal-Lesso
Mechanical Engineering Department, Universidad de Guanajuato, Salamanca 36885, Guanajuato, Mexico
2 shared publications - Ender A. Finol
Department of Mechanical, Aerospace, and Industrial Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA
2 shared publications
Latest Publications
- Open Access
- 22 July 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (15) , 1719
Numerical Assessment of the Structural Effects of Relative Sliding between Tissues in a Finite Element Model of the Foot
Penetration and shared nodes between muscles, tendons and the plantar aponeurosis mesh elements in finite element models of the foot may cause inappropriate structural behavior of the tissues. Penetration between tissues caused using separate mesh without motion constraints or contacts can change the loading direction because of an inadequate mesh displacement. Shared nodes between mesh elements create bonded areas in the model, causing progressive or complete loss of load transmitted by tissue. This paper compares by the finite element method the structural behavior of the foot model in cases where a shared mesh has been used versus a separated mesh with sliding contacts between some important tissues. A very detailed finite element model of the foot and ankle that simulates the muscles, tendons and plantar aponeurosis with real geometry has been used for the research. The analysis showed that the use of a separate mesh with sliding contacts and a better characterization of the mechanical behavior of the soft tissues increased the mean of the absolute values of stress by 83.3% and displacement by 17.4% compared with a shared mesh. These increases mean an improvement of muscle and tendon behavior in the foot model. Additionally, a better quantitative and qualitative distribution of plantar pressure was also observed.
- 22 July 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (15) , 1719
Open AccessNumerical Assessment of the Structural Effects of Relative Sliding between Tissues in a Finite Element Model of the Foot
Penetration and shared nodes between muscles, tendons and the plantar aponeurosis mesh elements in finite element models of the foot may cause inappropriate structural behavior of the tissues. Penetration between tissues caused using separate mesh without motion constraints or contacts can change the loading direction because of an inadequate mesh displacement. Shared nodes between mesh elements create bonded areas in the model, causing progressive or complete loss of load transmitted by tissue. This paper compares by the finite element method the structural behavior of the foot model in cases where a shared mesh has been used versus a separated mesh with sliding contacts between some important tissues. A very detailed finite element model of the foot and ankle that simulates the muscles, tendons and plantar aponeurosis with real geometry has been used for the research. The analysis showed that the use of a separate mesh with sliding contacts and a better characterization of the mechanical behavior of the soft tissues increased the mean of the absolute values of stress by 83.3% and displacement by 17.4% compared with a shared mesh. These increases mean an improvement of muscle and tendon behavior in the foot model. Additionally, a better quantitative and qualitative distribution of plantar pressure was also observed.
- 1 October 2019
- Published by Springer Nature
- p. 874-883
Assessment of Plantar Pressure in a Foot Finite Element Model Considering a Sliding Contact Between Soft Tissues
- 1 October 2019
- Published by Springer Nature
- p. 874-883
Assessment of Plantar Pressure in a Foot Finite Element Model Considering a Sliding Contact Between Soft Tissues
- 1 October 2019
- Published by Springer Nature
- p. 769-776
Understanding Ventricular Tachyarrhythmias Related to Acute Myocardial Ischemia: A Computational Modeling Approach
- 1 October 2019
- Published by Springer Nature
- p. 769-776
Understanding Ventricular Tachyarrhythmias Related to Acute Myocardial Ischemia: A Computational Modeling Approach
- 1 January 2019
- Published by Elsevier
- p. 115-138
Multiscale Numerical Simulation of Heart Electrophysiology
- 1 January 2019
- Published by Elsevier
- p. 115-138
Multiscale Numerical Simulation of Heart Electrophysiology
- 1 November 2015
- Published by Elsevier in Microprocessors and Microsystems
- Vol. 39 (8) , 854-865
Virtual prototyping of pressure driven microfluidic systems with SystemC-AMS extensions
- 1 November 2015
- Published by Elsevier in Microprocessors and Microsystems
- Vol. 39 (8) , 854-865
Virtual prototyping of pressure driven microfluidic systems with SystemC-AMS extensions
- 1 November 2015
- Published by Elsevier in Computer Physics Communications
- Vol. 196, 280-289
GPU accelerated solver for nonlinear reaction–diffusion systems. Application to the electrophysiology problem
- 1 November 2015
- Published by Elsevier in Computer Physics Communications
- Vol. 196, 280-289
GPU accelerated solver for nonlinear reaction–diffusion systems. Application to the electrophysiology problem
- 3 June 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 18 (14) , 1596-1605
Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion
The Montgomery T-tube is used as a combined tracheal stent and airway after laryngotracheoplasty, to keep the lumen open and prevent mucosal laceration from scarring. It is valuable in the management of upper and mid-tracheal lesions, while invaluable in long and multisegmental stenting lesions. Numerical simulations based on real-patient-tracheal geometry, experimental tissue characterization, and previous numerical estimation of the physiological swallowing force are performed to estimate the consequences of Montgomery T-tube implantation on swallowing and assisted ventilation: structural analysis of swallowing is performed to evaluate patient swallowing capacity, and computational fluid dynamics simulation is carried out to analyze related mechanical ventilation. With an inserted Montgomery T-tube, vertical displacement (Z-axis) reaches 8.01 mm, whereas in the Y-axis, it reaches 6.63 mm. The maximal principal stress obtained during swallowing was 1.6 MPa surrounding the hole and in the upper contact with the tracheal wall. Fluid flow simulation of the mechanical ventilation revealed positive pressure for both inhalation and exhalation, being higher for inspiration. The muscular deflections, considerable during normal breathing, are nonphysiological, and this aspect results in a constant overload of the tracheal muscle. During swallowing, the trachea ascends producing a nonhomogeneous elongation. This movement can be compromised when prosthesis is inserted, which explains the high incidence of glottis close inefficiency. Fluid simulations showed that nonphysiological pressure is established inside the trachea due to mechanical ventilation. This may lead to an overload of the tracheal muscle, explaining several related problems as muscle thinning or decrease in contractile function.
- 3 June 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 18 (14) , 1596-1605
Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion
The Montgomery T-tube is used as a combined tracheal stent and airway after laryngotracheoplasty, to keep the lumen open and prevent mucosal laceration from scarring. It is valuable in the management of upper and mid-tracheal lesions, while invaluable in long and multisegmental stenting lesions. Numerical simulations based on real-patient-tracheal geometry, experimental tissue characterization, and previous numerical estimation of the physiological swallowing force are performed to estimate the consequences of Montgomery T-tube implantation on swallowing and assisted ventilation: structural analysis of swallowing is performed to evaluate patient swallowing capacity, and computational fluid dynamics simulation is carried out to analyze related mechanical ventilation. With an inserted Montgomery T-tube, vertical displacement (Z-axis) reaches 8.01 mm, whereas in the Y-axis, it reaches 6.63 mm. The maximal principal stress obtained during swallowing was 1.6 MPa surrounding the hole and in the upper contact with the tracheal wall. Fluid flow simulation of the mechanical ventilation revealed positive pressure for both inhalation and exhalation, being higher for inspiration. The muscular deflections, considerable during normal breathing, are nonphysiological, and this aspect results in a constant overload of the tracheal muscle. During swallowing, the trachea ascends producing a nonhomogeneous elongation. This movement can be compromised when prosthesis is inserted, which explains the high incidence of glottis close inefficiency. Fluid simulations showed that nonphysiological pressure is established inside the trachea due to mechanical ventilation. This may lead to an overload of the tracheal muscle, explaining several related problems as muscle thinning or decrease in contractile function.
- 22 November 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (11) , 1248-1260
Impedance-based outflow boundary conditions for human carotid haemodynamics
In this study, we develop structured tree outflow boundary conditions for modelling the human carotid haemodynamics. The model geometry was reconstructed through computerised tomography scan. Unsteady-state computational fluid dynamic analyses were performed under different conditions using a commercial software package ADINA R&D, Inc., (Watertown, MA, USA) in order to assess the impact of the boundary conditions on the flow variables. In particular, the results showed that the peripheral vessels massively impact the pressure while the flow is relatively unaffected. As an example of application of these outflow conditions, an unsteady fluid-structure interaction (FSI) simulation was carried out and the dependence of the wall shear stress (WSS) on the arterial wall compliance in the carotid bifurcation was studied. In particular, a comparison between FSI and rigid-wall models was conducted. Results showed that the WSS distributions were substantially affected by the diameter variation of the arterial wall. In particular, even similar WSS distributions were found for both cases, and differences in the computed WSS values were also found.
- 22 November 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (11) , 1248-1260
Impedance-based outflow boundary conditions for human carotid haemodynamics
In this study, we develop structured tree outflow boundary conditions for modelling the human carotid haemodynamics. The model geometry was reconstructed through computerised tomography scan. Unsteady-state computational fluid dynamic analyses were performed under different conditions using a commercial software package ADINA R&D, Inc., (Watertown, MA, USA) in order to assess the impact of the boundary conditions on the flow variables. In particular, the results showed that the peripheral vessels massively impact the pressure while the flow is relatively unaffected. As an example of application of these outflow conditions, an unsteady fluid-structure interaction (FSI) simulation was carried out and the dependence of the wall shear stress (WSS) on the arterial wall compliance in the carotid bifurcation was studied. In particular, a comparison between FSI and rigid-wall models was conducted. Results showed that the WSS distributions were substantially affected by the diameter variation of the arterial wall. In particular, even similar WSS distributions were found for both cases, and differences in the computed WSS values were also found.
- 31 October 2011
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 35 (10) , 4902-4912
FE simulation of human trachea swallowing movement before and after the implantation of an endoprothesis
- 31 October 2011
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 35 (10) , 4902-4912
FE simulation of human trachea swallowing movement before and after the implantation of an endoprothesis
- 1 August 2011
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 38 (7) , 855-862
Numerical modeling of a human stented trachea under different stent designs
- 1 August 2011
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 38 (7) , 855-862
Numerical modeling of a human stented trachea under different stent designs