Erich G. Rohwer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Erich G. Rohwer has a total of 218 co-authors. Here are the top co-authors by number of shared publications:
- Pieter H. Neethling
NITheCS (National Institute for Theoretical and Computational Sciences)
21 shared publications - Dirk-Mathys Spangenberg
LRI, Stellenbosch University, Private Bag X1, 7602 Matieland, South Africa
12 shared publications - Christine Margarete Steenkamp
Stellenbosch University
11 shared publications H. Stafast
Leibniz Institute of Photonic Technology
11 shared publicationsThomas Feurer
Univ Bern, Inst Appl Phys, Sidlerstr 5, CH-3012 Bern, Switzerland
9 shared publications- Anton du Plessis
Physics Department, Stellenbosch University, Stellenbosch, South Africa
8 shared publications
Latest Publications
- 15 July 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (16) , 27278-27302
Calculating point spread functions: methods, pitfalls, and solutions
The knowledge of the exact structure of the optical system point spread function (PSF) enables a high-quality image reconstruction in fluorescence microscopy. Accurate PSF models account for the vector nature of light and the phase and amplitude modifications. Most existing real-space-based PSF models fall into a sampling pitfall near the center position, yielding to the violation of energy conservation. In this work, we present a novel, to the best of our knowledge, Fourier-based techniques for computing vector PSF and compare them to the state-of-the-art. Our methods are shown to satisfy the physical condition of the imaging process. They are reproducible, computationally efficient, easy to implement, and easy to modify to represent various imaging modalities.
- 15 July 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (16) , 27278-27302
Calculating point spread functions: methods, pitfalls, and solutions
The knowledge of the exact structure of the optical system point spread function (PSF) enables a high-quality image reconstruction in fluorescence microscopy. Accurate PSF models account for the vector nature of light and the phase and amplitude modifications. Most existing real-space-based PSF models fall into a sampling pitfall near the center position, yielding to the violation of energy conservation. In this work, we present a novel, to the best of our knowledge, Fourier-based techniques for computing vector PSF and compare them to the state-of-the-art. Our methods are shown to satisfy the physical condition of the imaging process. They are reproducible, computationally efficient, easy to implement, and easy to modify to represent various imaging modalities.
- 20 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (14) , 24346-24357
Time-domain vector ptychography
We demonstrate the reconstruction of the instantaneous polarization state of ultrafast laser pulses through vectorial time-domain ptychography. We introduce the formalism, investigate the algorithm’s capacities through simulations, and finally validate it by reconstructing several polarization states from experiments.
- 20 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (14) , 24346-24357
Time-domain vector ptychography
We demonstrate the reconstruction of the instantaneous polarization state of ultrafast laser pulses through vectorial time-domain ptychography. We introduce the formalism, investigate the algorithm’s capacities through simulations, and finally validate it by reconstructing several polarization states from experiments.
- 30 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (12) , 21887-21908
Experimental validation of numerical point spread function calculation including aberration estimation
Image reconstruction in fluorescence microscopy is highly sensitive to the accuracy of the impulse response, defined as the point spread function (PSF), of the optical system under which the image to reconstruct was acquired. In our previous work, we developed a MATLAB toolbox for accurately calculating realistic vector Fourier-based PSF accounting for any type of aberrations [ arXiv, arXiv:2301.13515 (2023)10.48550/arXiv.2301.13515 ]. In this work, we present a fundamental experimental validation of these numerical methods. The simulated results are found to fit experimental data under different image acquisition conditions at an accuracy higher than 0.97 in normalized cross-correlation. These methods enable a relative contrast of up to 95%.
- 30 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (12) , 21887-21908
Experimental validation of numerical point spread function calculation including aberration estimation
Image reconstruction in fluorescence microscopy is highly sensitive to the accuracy of the impulse response, defined as the point spread function (PSF), of the optical system under which the image to reconstruct was acquired. In our previous work, we developed a MATLAB toolbox for accurately calculating realistic vector Fourier-based PSF accounting for any type of aberrations [ arXiv, arXiv:2301.13515 (2023)10.48550/arXiv.2301.13515 ]. In this work, we present a fundamental experimental validation of these numerical methods. The simulated results are found to fit experimental data under different image acquisition conditions at an accuracy higher than 0.97 in normalized cross-correlation. These methods enable a relative contrast of up to 95%.
- 19 December 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (1) , 9-20
Mid Infrared supercontinuum generation in a silicon germanium photonic waveguide
We report simulations of pulse evolution along a 5 cm long silicon germanium (SiGe) photonic waveguide. Femtosecond laser pulses of duration 210 fs and wavelength of 4.7 µm close to the first zero dispersion wavelength (ZDW) of SiGe situated at 4.6 µm were used in pumping the SiGe photonic waveguide. Simulations were made by solving the generalised nonlinear Schrödinger equation for the femtosecond pump pulse evolution along the length of SiGe photonic waveguide using the fourth order Runge-Kutta in the interaction picture method. The simulated supercontinum spans the 2.5–8.5 µm spectral region comprising of molecular signatures for most hazardous and greenhouse gases making it attractive for environmental monitoring applications.
- 19 December 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (1) , 9-20
Mid Infrared supercontinuum generation in a silicon germanium photonic waveguide
We report simulations of pulse evolution along a 5 cm long silicon germanium (SiGe) photonic waveguide. Femtosecond laser pulses of duration 210 fs and wavelength of 4.7 µm close to the first zero dispersion wavelength (ZDW) of SiGe situated at 4.6 µm were used in pumping the SiGe photonic waveguide. Simulations were made by solving the generalised nonlinear Schrödinger equation for the femtosecond pump pulse evolution along the length of SiGe photonic waveguide using the fourth order Runge-Kutta in the interaction picture method. The simulated supercontinum spans the 2.5–8.5 µm spectral region comprising of molecular signatures for most hazardous and greenhouse gases making it attractive for environmental monitoring applications.
- 14 September 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A285-A292
Generalized spectral phase-only time-domain ptychographic phase reconstruction applied in nonlinear microscopy
Nonlinear microscopy has evolved over the last few decades to become a powerful tool for imaging and spectroscopic applications in biological sciences. In this study, i 2 P I E , a novel spectral phase control technique, was implemented in order to compress broad-bandwidth supercontinuum light pulses generated in an all-normal-dispersion (ANDi) photonic crystal fiber (PCF). The technique, based on time-domain ptychography, is demonstrated here in a nonlinear microscopy application for the first time, to the best of our knowledge. The first real-world application of this technique for second-harmonic generation and two-photon excitation fluorescence microscopies in biological samples is presented. We further show that in our implementation, i 2 P I E leads to improved contrast and signal-to-noise ratios in the generated images, compared to conventional compression techniques used in nonlinear microscopy.
- 14 September 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A285-A292
Generalized spectral phase-only time-domain ptychographic phase reconstruction applied in nonlinear microscopy
Nonlinear microscopy has evolved over the last few decades to become a powerful tool for imaging and spectroscopic applications in biological sciences. In this study, i 2 P I E , a novel spectral phase control technique, was implemented in order to compress broad-bandwidth supercontinuum light pulses generated in an all-normal-dispersion (ANDi) photonic crystal fiber (PCF). The technique, based on time-domain ptychography, is demonstrated here in a nonlinear microscopy application for the first time, to the best of our knowledge. The first real-world application of this technique for second-harmonic generation and two-photon excitation fluorescence microscopies in biological samples is presented. We further show that in our implementation, i 2 P I E leads to improved contrast and signal-to-noise ratios in the generated images, compared to conventional compression techniques used in nonlinear microscopy.
- 8 September 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A259-A265
Implementation of temporal ptychography algorithm, i2PIE, for improved single-beam coherent anti-Stokes Raman scattering measurements
We present an improvement on the signal-to-background of single-beam coherent anti-Stokes Raman scattering (SB-CARS) spectroscopy measurements for systems employing ultrafast supercontinuum sources based on all-normal dispersion photonic crystal fibers. Improvements to the signal-to-background arise in the use of a new pulse-reconstruction algorithm based on temporal ptychography, i 2 P I E . A simple SB-CARS strategy is used to measure the spectrum of para-xylene, where the supercontinuum pulses used are compressed using multiphoton intrapulse interference phase scan (MIIPS) and, for the first time to the best of our knowledge, i 2 P I E using the same single-beam setup. With the i 2 P I E implementation, the signal-to-background is improved by nearly a factor of 4 in comparison with MIIPS. More notably, the integrated SB-CARS spectral intensity is increased by a factor of 6.5.
- 8 September 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A259-A265
Implementation of temporal ptychography algorithm, i2PIE, for improved single-beam coherent anti-Stokes Raman scattering measurements
We present an improvement on the signal-to-background of single-beam coherent anti-Stokes Raman scattering (SB-CARS) spectroscopy measurements for systems employing ultrafast supercontinuum sources based on all-normal dispersion photonic crystal fibers. Improvements to the signal-to-background arise in the use of a new pulse-reconstruction algorithm based on temporal ptychography, i 2 P I E . A simple SB-CARS strategy is used to measure the spectrum of para-xylene, where the supercontinuum pulses used are compressed using multiphoton intrapulse interference phase scan (MIIPS) and, for the first time to the best of our knowledge, i 2 P I E using the same single-beam setup. With the i 2 P I E implementation, the signal-to-background is improved by nearly a factor of 4 in comparison with MIIPS. More notably, the integrated SB-CARS spectral intensity is increased by a factor of 6.5.
- 18 August 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A228-A236
Counter-intuitive strength of electric field induced second harmonic (EFISH) signals at the rear side of thin silicon membranes
Electric field induced second harmonic (EFISH) generation typically increases with laser intensity. Therefore, EFISH signals generated at the rear S i / S i O 2 interface by a laser beam transmitted through a thin silicon membrane should be much weaker than the signals generated in reflection at the front surface. The counter-intuitive finding that the signal generated at the rear surface is stronger than the front surface signal [ Appl. Phys. B 104, 735 (2011)APBOEM 0946-2171 10.1007/s00340-011-4682-1 ] is now confirmed by detailed experiments applying 10 to 30 µm thin membranes. Using, in addition, the local laser beam intensity [ Appl. Phys. B 123, 253 (2017)APBOEM 0946-2171 10.1007/s00340-017-6824-6 ] leads to the hypothesis that the quasi-static electric field at the rear interface consists of two counteracting components.
- 18 August 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (11) , A228-A236
Counter-intuitive strength of electric field induced second harmonic (EFISH) signals at the rear side of thin silicon membranes
Electric field induced second harmonic (EFISH) generation typically increases with laser intensity. Therefore, EFISH signals generated at the rear S i / S i O 2 interface by a laser beam transmitted through a thin silicon membrane should be much weaker than the signals generated in reflection at the front surface. The counter-intuitive finding that the signal generated at the rear surface is stronger than the front surface signal [ Appl. Phys. B 104, 735 (2011)APBOEM 0946-2171 10.1007/s00340-011-4682-1 ] is now confirmed by detailed experiments applying 10 to 30 µm thin membranes. Using, in addition, the local laser beam intensity [ Appl. Phys. B 123, 253 (2017)APBOEM 0946-2171 10.1007/s00340-017-6824-6 ] leads to the hypothesis that the quasi-static electric field at the rear interface consists of two counteracting components.
- 6 January 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (2) , 300-303
Extending time-domain ptychography to generalized phase-only transfer functions
We extend the time-domain ptychographic iterative engine to generalized spectral phase-only transfer functions. The modified algorithm, i 2 P I E , is described and a method to choose phase-only transfer functions is defined. The robustness of the algorithm, in conjunction with the defined method of transfer function selection, is demonstrated by numeric simulation and experiment.
- 6 January 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (2) , 300-303
Extending time-domain ptychography to generalized phase-only transfer functions
We extend the time-domain ptychographic iterative engine to generalized spectral phase-only transfer functions. The modified algorithm, i 2 P I E , is described and a method to choose phase-only transfer functions is defined. The robustness of the algorithm, in conjunction with the defined method of transfer function selection, is demonstrated by numeric simulation and experiment.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Time-Domain Ptychography
Diffraction imaging is a widely used concept in lens-less imaging. The key challenge is to reconstruct the phase of diffracted waves, and several solutions to this so-called phase problem have been published. One of the most robust techniques is ptychography. Its concept is related to the solution of the phase problem in crystallography as proposed by Hoppe [1]. It was first demonstrated at optical wavelengths [2], but its scientific impact is expected to be largest at X-ray wavelengths, especially after commissioning high brightness coherent X-ray sources. In ptychography the real-space image of an object is reconstructed from a series of far-field diffraction patterns where each pattern is recorded after either translating the object or the coherent illumination beam.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Time-Domain Ptychography
Diffraction imaging is a widely used concept in lens-less imaging. The key challenge is to reconstruct the phase of diffracted waves, and several solutions to this so-called phase problem have been published. One of the most robust techniques is ptychography. Its concept is related to the solution of the phase problem in crystallography as proposed by Hoppe [1]. It was first demonstrated at optical wavelengths [2], but its scientific impact is expected to be largest at X-ray wavelengths, especially after commissioning high brightness coherent X-ray sources. In ptychography the real-space image of an object is reconstructed from a series of far-field diffraction patterns where each pattern is recorded after either translating the object or the coherent illumination beam.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Novel Self-Referencing Time-Domain THz Ellipsometer for Measurement of Samples in Aqueous Environments
THz spectroscopy has gained traction as analytical technique due to availability of bright, compact, broadband and coherent sources based on photoconductive antennas and compact femtosecond lasers. The main limitation of this technique remains the strong absorption by water in this spectral region. Some of the solutions to circumvent this problem has been using very thins samples [1], flash frozen samples [2] and measurements in reflection [3]. In this paper we describe the first measurements of a custom built self-referencing time domain THz ellipsometer.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Novel Self-Referencing Time-Domain THz Ellipsometer for Measurement of Samples in Aqueous Environments
THz spectroscopy has gained traction as analytical technique due to availability of bright, compact, broadband and coherent sources based on photoconductive antennas and compact femtosecond lasers. The main limitation of this technique remains the strong absorption by water in this spectral region. Some of the solutions to circumvent this problem has been using very thins samples [1], flash frozen samples [2] and measurements in reflection [3]. In this paper we describe the first measurements of a custom built self-referencing time domain THz ellipsometer.