AKAlexander Kolb

Alexander Kolb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Kolb has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Minimally Invasive Surgical Technique for Eight-Plate Hemiepiphysiodesis: Description and Evaluation

    by Stephan Heisinger, Johannes Sommeregger, Carmen Trost, Madeleine Willegger, Markus Schreiner, Reinhard Windhager, Alexander Kolb

    Background: Temporary hemiepiphysiodesis with tension band plates or eight-plates is a common surgical procedure to treat malalignment of the lower limb axis in skeletally immature patients. The objective of this study was to compare a new minimally invasive surgical procedure with the conventional procedure and evaluate its safety and effectiveness in order to reduce the risk of hypertrophic scarring, which may cause functional impairment as well as cosmetic issues. Methods: Sixty-five growth plates of either the femur or the tibia were evaluated in 33 patients treated for genu valgum or varum between 2010 and 2017. Each growth plate was considered an individual case. The modified procedure was used in 17 cases and the conventional procedure in 48 cases. The modified surgical procedure is characterized by an 8 mm incision and preparation of the epi-periosteal layer, in which the eight-plate is positioned via a guide-wire. Positioning and implantation are controlled via fluoroscopy. Skin incision length, duration of surgery, revision rate, achievement of a defined correction goal, and correction rate were analyzed. Results: Using the minimally invasive procedure, the mean skin incision length (23.94 ± 10.18 mm vs. 8.75 ± 2.14 mm, p < 0.001) could be significantly reduced. No significant difference was found in regard to the duration of surgery, revision rate, achievement of the correction goal or correction rate. Conclusions: The minimally invasive procedure results in a reduction in incision length without significant impact on the duration of surgery, revision rate, achievement of correction goal or correction rate. Consequently, the modified procedure can be regarded as equally as effective and safe as the conventional procedure.

  • Behandlung der Patellainstabilität

    by Alexander Kolb, Madeleine Willegger, Catharina Chiari, Reinhard Windhager

    Die Patellainstabilität ist für die PatientenInnen eine belastende Erkrankung mit einer in der orthopädischen Praxis häufig auftretenden Problemstellung. Die Anomalien des patellofemoralen Gelenks, die die Stabilität des Kniescheibenlaufs beeinträchtigen können, sind vielfältig, sodass für eine erfolgreiche Therapie eine strukturierte Analyse essenziell ist. Dieser Beitrag zeigt den Aufbau einer differenzierten Diagnostik und Therapie sowie Beispiele aus der Praxis. Article published online: 12 October 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Behandlung der Patellainstabilität

    by Alexander Kolb, Madeleine Willegger, Catharina Chiari, Reinhard Windhager

    Die Patellainstabilität ist für die PatientenInnen eine belastende Erkrankung mit einer in der orthopädischen Praxis häufig auftretenden Problemstellung. Die Anomalien des patellofemoralen Gelenks, die die Stabilität des Kniescheibenlaufs beeinträchtigen können, sind vielfältig, sodass für eine erfolgreiche Therapie eine strukturierte Analyse essenziell ist. Dieser Beitrag zeigt den Aufbau einer differenzierten Diagnostik und Therapie sowie Beispiele aus der Praxis. Article published online: 13 April 2021 © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns

    by Alexander Kolb, Catharina Chiari, Markus Schreiner, Stephan Heisinger, Madeleine Willegger, Gregor Rettl, Reinhard Windhager

    To develop an electronic navigation system to increase reliability and comparability in the ultrasound screening of developmental dysplasia of the hip (DDH). The impact of the navigation system on transducer positioning and on sonographic measurements according to Graf was analyzed. Twenty hips in newborns were examined sonographically using a new navigation system capable of detecting the transducer and pelvis position in order to calculate the relative tilt in the frontal, axial, and sagittal-plane. In each newborn an ultrasound image was obtained conventionally according to Graf and a second image using the sonographic navigation system. Relative roll and pitch angles and sonographic measurements were analyzed using paired T-tests and Levene-tests. Relative tilt angles in the conventional group ranged from − 8.9° to 14.3° (frontal-plane) and − 23.8° to 14.2° (axial-plane). In the navigation-assisted group ranges from − 3.0° to 3.5° and − 2.8° to 4.5° were observed. Variances were significantly lower in the navigation-assisted group (p < 0.001 and p = 0.004 respectively). The navigation system allowed for a significant reduction of relative tilt angles between the transducer and the newborn pelvis, thus supporting an optimal transducer positioning. This is a promising approach to improve reproducibility and reliability in the ultrasound screening for DDH.


  • Open Access

    Radiographic Sagittal Tibio-Talar Offset in Ankle Arthrodesis—Accuracy and Reliability of Measurements

    by Sophie Schieder, Elena Nemecek, Reinhard Schuh, Alexander Kolb, Reinhard Windhager, Madeleine Willegger

    Radiographic outcome assessment of ankle arthrodesis (AA) requires accurate measurement techniques. This study aimed to identify the most reliable methods for sagittal tibio-talar alignment measurements with regard to the tibio-talar offset after AA. Lateral weight-bearing radiographs of 38 fused ankles were selected for retrospective review. The sagittal tibio-talar angle (STTA), the modified tibio-talar ratio (mT-T ratio) and the sagittal tibio-talar offset (tibCOR, procLAT) were measured by three independent observers. Intra- and interobserver correlation coefficients (ICC) and mean measurement differences were calculated to assess measurement reliability and accuracy. By defining the talar longitudinal axis as a line from the inferior aspect of the posterior tubercle of the talus to the most inferior aspect of the talar neck, STTA showed excellent (ICC 0.924; CI 95% 0.862–0.959) and mTT-ratio provided high (ICC 0.836; CI 95% 0.721–0.909) interobserver reliability, respectively. For tibio-talar offset measurement the tibCOR method showed superior reliability and better interobserver agreement compared to the procLAT technique. The STTA and a modified T-T ratio are recommended for future scientific radiographic measurements in AA.


  • Open Access

    Correction to: Analysis and quantification of bone healing after open wedge high tibial osteotomy

    by E. Nemecek, C. Chiari, A. Valentinitsch, F. Kainberger, G. Hobusch, A. Kolb, L. Hirtler, C. Trost, S. Vukicevic, R. Windhager

    Correction to: Wien Klin Wochenschr 2019 https://doi.org/10.1007/s00508-019-01541-8 The original version of this article unfortunately contained a mistake. The presentation of Tab. 4 was incorrect....


  • Open Access

    Evaluation of Aerosol Electrospray Analysis of Metal-on-Metal Wear Particles from Simulated Total Joint Replacement

    by Gobert von Skrbensky, Karoline Mühlbacher, Emir Benca, Alexander Kolb, Reinhard Windhager, Georg Reischl, Georg Reinisch

    Wear is a common cause for aseptic loosening in artificial joints. The purpose of this study was to develop an automated diagnostical method for identification of the number and size distribution of wear debris. For this purpose, metal debris samples were extracted from a hip simulator and then analyzed by the electrospray method combined with a differential mobility analyzer, allowing particle detection ranging from several nanometers up to 1 µm. Wear particles were identified with a characteristic peak at 15 nm. The electrospray setup was successfully used and validated for the first time to characterize wear debris from simulated total joint replacement. The advantages of this diagnostic method are its time- and financial efficiency and its suitability for testing of different materials.


  • Open Access

    Distal femoral varus osteotomy: results of the lateral open-wedge technique without bone grafting

    by Alexander Kolb, Verena Isak, Gerhard M. Hobusch, Catharina Chiari, Reinhard Windhager

    Background The lateral opening wedge distal femoral osteotomy (LOWDFO) to reconstruct knee alignment in patients with genu valgum originating in the distal femur has gained importance within the last years. Purpose To analyze clinical and radiographic outcome of patients treated with LOWDFO with respect to bone healing without grafting and patient age. Material and methods Twenty-two consecutive patients with genu valgum corrected with 23 LOWDFOs using a Tomofix-locking plate were retrospectively analyzed (mean age 23.7 years). Clinical evaluation was based on pre- and post-operative KOOS scores. A pre- and post-operative radiographic assessment, including MAD, mLDFA, LLD, bone healing, and patella parameters, was performed. Differences between subgroups (age, bone grafting) were analyzed. Results The restoration of MAD and mLDFA resulted in significantly improved post-operative KOOS5 scores in younger and older patients (p = 0.001). Bone healing without bone grafting was reliable in all patients. The leg length was significantly increased post-operatively (p = 0.001). The Blackburne-Peel ratio was significantly reduced to more normal values post-operatively (p < 0.001). Conclusion LOWDFO without bone grafting is a reliable procedure representing a promising treatment option particularly in young patients with genu valgum. Besides correction of the MAD, a significant leg length increase and additional patella stability can be expected.


  • The role of the subchondral layer in osteonecrosis of the femoral head: analysis based on HR-QCT in comparison to MRI findings

    by Alexander R Kolb, Janina M Patsch, Wolf-Dieter Vogl, Emir Benca, David Stelzeneder, Reinhard Windhager, Jochen G Hofstaetter

    Non-traumatic avascular osteonecrosis of the femoral head (ONFH) is a severe disease causing destruction of the hip joint, often necessitating total hip arthroplasty (THA) even in young patients. Magnetic resonance imaging (MRI) is commonly used for diagnosis of ONFH, but provides limited insight into the subchondral bone microstructure. To analyze routine MRI findings in comparison to high-resolution quantitative computed tomography (HR-QCT) with a special focus on the subchondral layer and to estimate the importance of differences determining the indication for THA. Twelve patients with ONFH were included before THA. Preoperative MRI and HR-QCT of the retrieved femoral heads were aligned using a registration algorithm. Pathological findings and trabecular bone parameters in matched areas were analyzed by two readers. McNemar, marginal homogeneity test, and Pearson’s correlation coefficient were used for comparison. Subchondral delamination was found in nine cases on HR-QCT, but missed or underestimated in all but one case on MRI (P = 0.016). Chondral discontinuity was found in all cases on HR-QCT and in two cases on MRI (P = 0.016). Areas of complete bone resorption on HR-QCT were linked to high signal intensity on 3D gradient-echo MRI sequences with water-selective excitation, while there was no correlation between trabecular bone parameters and MRI signal intensities in other areas (P = 0.304). Subchondral delamination, subchondral resorption, and chondral discontinuity are found frequently in advanced stages of ONFH. These lesions tend to be underestimated on conventional MRI. Our results support the importance of CT imaging in the evaluation of ONFH.


  • Open Access

    Vessel architecture in human knee cartilage in children: an in vivo susceptibility-weighted imaging study at 7 T

    by Alexander Kolb, Simon Robinson, David Stelzeneder, Markus Schreiner, Catharina Chiari, Reinhard Windhager, Siegfried Trattnig, Klaus Bohndorf

    Objectives To evaluate the clinical feasibility of ultrahigh field 7-T SWI to visualize vessels and assess their density in the immature epiphyseal cartilage of human knee joints. Methods 7-T SWI of 12 knees (six healthy volunteers, six patients with osteochondral abnormalities; mean age 10.7 years; 3 female, 9 male) were analysed by two readers, classifying intracartilaginous vessel densities (IVD) in three grades (no vessels, low IVD and high IVD) in defined femoral, tibial and patellar zones. Differences between patients and volunteers, IVDs in different anatomic locations, differences between cartilage overlying osteochondral abnormalities and corresponding normal zones, and differences in age groups were analysed. Results Interrater reliability showed moderate agreement between the two readers (κ = 0.58, p < 0.001). The comparison of IVDs between patients and volunteers revealed no significant difference (p = 0.706). The difference between zones in the cartilage overlying osteochondral abnormalities to corresponding normal zones showed no significant difference (p = 0.564). IVDs were related to anatomic location, with decreased IVDs in loading areas (p = 0.003). IVD was age dependent, with more vessels present in the younger participants (p = 0.001). Conclusions The use of SWI in conjunction with ultrahigh field MRI makes the in vivo visualization of vessels in the growing cartilage of humans feasible, providing insights into the role of the vessel network in acquired disturbances. Key Points • SWI facilitates in vivo visualization of vessels in the growing human cartilage. • Interrater reliability of the intracartilaginous vessel grading was moderate. • Intracartilaginous vessel densities are dependent on anatomical location and age.