Wen Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wen Jin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Yibo Zhao
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA
4 shared publications - Yudu Li
Beckman Institute for Advanced Science and Technology University of Illinois at Urbana‐Champaign Urbana Illinois USA
4 shared publications - Rong Guo
Beckman Institute for Advanced Science and Technology University of Illinois at Urbana‐Champaign Urbana Illinois USA
3 shared publications - Zhi-Pei Liang
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, USA
3 shared publications - Junfeng Sun
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
2 shared publications - Shanbao Tong
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
Denoising of ASL Data Using Deep Learning Priors Generated From Distribution Remapping
Purpose: To develop an effective deep learning (DL)–based method to denoise arterial spin labeling (ASL) data. Methods: Conventional DL–based ASL denoising methods often suffer from overfitting and poor generalization when training data are limited. The proposed method overcame this problem using two strategies: (i) perform data augmentation to create large training data and (ii) denoise in‐distribution and out‐of‐distribution components of the target perfusion‐weighted image separately. Specifically, Image‐to‐Image Schrödinger Bridge (I 2 SB)–based distribution remapping transforms were applied to the large public ASL datasets so that their intensity distribution matched that of the data to be denoised. U‐Net–based DL denoisers were trained on the remapped data to capture in‐distribution features. High‐SNR outputs from the DL‐denoiser were incorporated into a Bayesian model to reconstruct the out‐of‐distribution features with sparsity constraints, generating denoised images for cerebral blood flow (CBF) quantification. Results: Simulation studies highlighted the importance of distribution remapping for effective data augmentation in limited‐data scenarios. Both simulation and in vivo experiments showed that the proposed method outperformed state‐of‐the‐art approaches, achieving an average SNR improvement of approximately 7 dB. Evaluations on multiple datasets confirmed robust and generalizable performance across different ASL sequences and imaging protocols. To demonstrate clinical potential, our method was applied to denoising stroke patient data (using only one‐sixth of total averages with ˜83% reduction in scan time) and produced comparable CBF maps to the conventional ASL method. Conclusion: The proposed method enables effective ASL denoising with limited training data. It has the potential to accelerate ASL acquisition, enhance image quality, and improve clinical utility.
- 10 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessDenoising of ASL Data Using Deep Learning Priors Generated From Distribution Remapping
Purpose: To develop an effective deep learning (DL)–based method to denoise arterial spin labeling (ASL) data. Methods: Conventional DL–based ASL denoising methods often suffer from overfitting and poor generalization when training data are limited. The proposed method overcame this problem using two strategies: (i) perform data augmentation to create large training data and (ii) denoise in‐distribution and out‐of‐distribution components of the target perfusion‐weighted image separately. Specifically, Image‐to‐Image Schrödinger Bridge (I 2 SB)–based distribution remapping transforms were applied to the large public ASL datasets so that their intensity distribution matched that of the data to be denoised. U‐Net–based DL denoisers were trained on the remapped data to capture in‐distribution features. High‐SNR outputs from the DL‐denoiser were incorporated into a Bayesian model to reconstruct the out‐of‐distribution features with sparsity constraints, generating denoised images for cerebral blood flow (CBF) quantification. Results: Simulation studies highlighted the importance of distribution remapping for effective data augmentation in limited‐data scenarios. Both simulation and in vivo experiments showed that the proposed method outperformed state‐of‐the‐art approaches, achieving an average SNR improvement of approximately 7 dB. Evaluations on multiple datasets confirmed robust and generalizable performance across different ASL sequences and imaging protocols. To demonstrate clinical potential, our method was applied to denoising stroke patient data (using only one‐sixth of total averages with ˜83% reduction in scan time) and produced comparable CBF maps to the conventional ASL method. Conclusion: The proposed method enables effective ASL denoising with limited training data. It has the potential to accelerate ASL acquisition, enhance image quality, and improve clinical utility.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 23-31
Phase Correction of MR Spectroscopic Imaging Data Using Model-Based Signal Estimation and Extrapolation
Objective: To develop an effective method for phase correction of magnetic resonance spectroscopic imaging (MRSI) data. Methods: In many MRSI applications, it is desirable to generate absorption-mode spectra, which requires correction of phase errors in the measured MRSI data. Conventional phase correction methods are sensitive to measurement noise and baseline distortion, often resulting in distorted absorption-mode spectra from MRSI data with low-SNR and long acquisition dead time. This paper proposed a novel model-based method for improved phase correction of MRSI data. The proposed method determined the zeroth-order phase and acquisition dead time using a Lorentzian-based spectral model and performed signal extrapolation using a generalized series model. Absorption-mode spectra were then generated from the phase-corrected and extrapolated MRSI data. Results: The proposed method was evaluated using both simulated data and experimental data acquired from human subjects in multi-nuclei (31P, 2H, and 1H) MRSI experiments. Simulation results demonstrated improved parameter estimation accuracy by the proposed method under various noise levels and dead times. The proposed method also consistently generated high-quality absorption-mode spectra with minimal spectral distortions from experimental data. The proposed method was compared with state-of-the-art methods (including the entropy method and LCModel method) and showed more robust phase correction performance with less spectral distortions. Conclusion: This paper introduced a novel method for phase correction of MRSI data. Results from simulated and in vivo data demonstrated that high-quality absorption-mode spectra could be obtained using the proposed method. Significance: This method will provide a useful tool for processing MRSI data.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 23-31
Open AccessPhase Correction of MR Spectroscopic Imaging Data Using Model-Based Signal Estimation and Extrapolation
Objective: To develop an effective method for phase correction of magnetic resonance spectroscopic imaging (MRSI) data. Methods: In many MRSI applications, it is desirable to generate absorption-mode spectra, which requires correction of phase errors in the measured MRSI data. Conventional phase correction methods are sensitive to measurement noise and baseline distortion, often resulting in distorted absorption-mode spectra from MRSI data with low-SNR and long acquisition dead time. This paper proposed a novel model-based method for improved phase correction of MRSI data. The proposed method determined the zeroth-order phase and acquisition dead time using a Lorentzian-based spectral model and performed signal extrapolation using a generalized series model. Absorption-mode spectra were then generated from the phase-corrected and extrapolated MRSI data. Results: The proposed method was evaluated using both simulated data and experimental data acquired from human subjects in multi-nuclei (31P, 2H, and 1H) MRSI experiments. Simulation results demonstrated improved parameter estimation accuracy by the proposed method under various noise levels and dead times. The proposed method also consistently generated high-quality absorption-mode spectra with minimal spectral distortions from experimental data. The proposed method was compared with state-of-the-art methods (including the entropy method and LCModel method) and showed more robust phase correction performance with less spectral distortions. Conclusion: This paper introduced a novel method for phase correction of MRSI data. Results from simulated and in vivo data demonstrated that high-quality absorption-mode spectra could be obtained using the proposed method. Significance: This method will provide a useful tool for processing MRSI data.
- Open Access
- 10 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1323-1335
Motion Correction in High‐Resolution 3D Brain MRSI Without Water and Lipid Suppression
Purpose: To develop an effective method for correcting head motion in high‐resolution, non‐water‐suppressed MRSI. Methods: MRSI scans are susceptible to subject motion due to the long data acquisition time required for sufficient spatial‐spectral encodings. The problem is more serious in non‐water‐suppressed MRSI experiments since motion artifacts in the water and lipid signals make their removal even more challenging. To address this problem, we propose a novel motion correction method that detects and discards motion‐corrupted k‐space data using TR‐wise linear navigators. The discarded data are replaced with reconstructed data obtained by reformulating motion correction as a missing data reconstruction problem using sensitivity encodings. Extrinsic priors for water and lipid signals and intrinsic priors for metabolite signals are incorporated in the motion correction process. We evaluated its performance on a spectroscopic phantom and three human groups: (1) five healthy adults performing three different voluntary motion patterns; (2) a healthy child; and (3) a cerebral hemorrhage patient with involuntary movements. Results: In phantom and healthy subjects, the proposed method produced high‐quality water images and metabolite maps that closely matched motion‐free references, with 10%–20% quantitative gains in image/map quality (higher PSNR/SSIM, lower NRMSE). In the child and patient data, motion artifacts were noticeably reduced, with 20%–30% reductions in NAA linewidth and fitting error in the child, and ˜50% reductions in coefficient‐of‐variation in the patient. Conclusion: An effective motion‐correction technique has been developed for high‐resolution non‐water‐suppressed MRSI. This method has the potential to significantly enhance the robustness and clinical applicability of non‐water‐suppressed MRSI.
- 10 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1323-1335
Open AccessMotion Correction in High‐Resolution 3D Brain MRSI Without Water and Lipid Suppression
Purpose: To develop an effective method for correcting head motion in high‐resolution, non‐water‐suppressed MRSI. Methods: MRSI scans are susceptible to subject motion due to the long data acquisition time required for sufficient spatial‐spectral encodings. The problem is more serious in non‐water‐suppressed MRSI experiments since motion artifacts in the water and lipid signals make their removal even more challenging. To address this problem, we propose a novel motion correction method that detects and discards motion‐corrupted k‐space data using TR‐wise linear navigators. The discarded data are replaced with reconstructed data obtained by reformulating motion correction as a missing data reconstruction problem using sensitivity encodings. Extrinsic priors for water and lipid signals and intrinsic priors for metabolite signals are incorporated in the motion correction process. We evaluated its performance on a spectroscopic phantom and three human groups: (1) five healthy adults performing three different voluntary motion patterns; (2) a healthy child; and (3) a cerebral hemorrhage patient with involuntary movements. Results: In phantom and healthy subjects, the proposed method produced high‐quality water images and metabolite maps that closely matched motion‐free references, with 10%–20% quantitative gains in image/map quality (higher PSNR/SSIM, lower NRMSE). In the child and patient data, motion artifacts were noticeably reduced, with 20%–30% reductions in NAA linewidth and fitting error in the child, and ˜50% reductions in coefficient‐of‐variation in the patient. Conclusion: An effective motion‐correction technique has been developed for high‐resolution non‐water‐suppressed MRSI. This method has the potential to significantly enhance the robustness and clinical applicability of non‐water‐suppressed MRSI.
- Open Access
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3558-3566
High-Resolution Brain Metabolic Imaging at Ultrahigh Field Using Extended Spatiospectral Encoding and Subspace Modeling
Objective: To develop a high-resolution magnetic resonance (MR) metabolic imaging method for mapping human brain metabolite distributions at ultrahigh field (7T). Methods: In data acquisition, a free-induction-decay (FID) based MR spectroscopic imaging (MRSI) sequence was implemented. To achieve high spatial resolution, the sequence used fast echo-planar spectroscopic imaging (EPSI) trajectories with echo-spacings larger than the Nyquist sampling interval. Using this sequence, 3D MRSI signals at isotropic nominal resolutions of 3.0 mm and 1.8 mm were acquired within scan times of 4.8 and 14.2 minutes, respectively. In data processing, model-based methods integrating subspace learning, spectral modeling, and generalized series modeling were developed to address key challenges, including spectral ghosting, low signal-to-noise ratio, and spectral aliasing. Results: The proposed acquisition and processing methods successfully generated high-resolution, high-quality metabolite maps of the human brain at 7T. Experimental results from phantom and in vivo scans validated the proposed method and showed its capability to capture detailed brain metabolite distributions. Conclusion: This work demonstrates the feasibility of high-resolution brain metabolic imaging at ultrahigh field using MRSI acquisition sequence and model-based processing methods. Significance: By providing high-resolution spatial mapping of brain metabolites within clinically feasible scan times, the proposed method promises to offer a powerful imaging tool for investigating brain metabolism, which is expected to be useful for various brain imaging applications.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3558-3566
Open AccessHigh-Resolution Brain Metabolic Imaging at Ultrahigh Field Using Extended Spatiospectral Encoding and Subspace Modeling
Objective: To develop a high-resolution magnetic resonance (MR) metabolic imaging method for mapping human brain metabolite distributions at ultrahigh field (7T). Methods: In data acquisition, a free-induction-decay (FID) based MR spectroscopic imaging (MRSI) sequence was implemented. To achieve high spatial resolution, the sequence used fast echo-planar spectroscopic imaging (EPSI) trajectories with echo-spacings larger than the Nyquist sampling interval. Using this sequence, 3D MRSI signals at isotropic nominal resolutions of 3.0 mm and 1.8 mm were acquired within scan times of 4.8 and 14.2 minutes, respectively. In data processing, model-based methods integrating subspace learning, spectral modeling, and generalized series modeling were developed to address key challenges, including spectral ghosting, low signal-to-noise ratio, and spectral aliasing. Results: The proposed acquisition and processing methods successfully generated high-resolution, high-quality metabolite maps of the human brain at 7T. Experimental results from phantom and in vivo scans validated the proposed method and showed its capability to capture detailed brain metabolite distributions. Conclusion: This work demonstrates the feasibility of high-resolution brain metabolic imaging at ultrahigh field using MRSI acquisition sequence and model-based processing methods. Significance: By providing high-resolution spatial mapping of brain metabolites within clinically feasible scan times, the proposed method promises to offer a powerful imaging tool for investigating brain metabolism, which is expected to be useful for various brain imaging applications.
- 9 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2253-2265
Extracting Individual Neural Fingerprint Encoded in Functional Connectivity by Silencing Indirect Effects
Objective: The possibility of subject discriminability based on whole-brain functional connectivity (FC) has been demonstrated. To extract more accurate “fingerprint” encoded in FC, we speculated that the indirect effects in FC might be unfavorable information for subject discriminability, then the remaining component of FC (referred as direct FC (dFC)) may constitute a better “fingerprint.” Methods: We adopted the silencing method to infer dFC from experimentally accessible FC and explained the superiority of dFC in subject discriminability from the perspective of test-retest reliability. Results: We showed that the subject discriminability of dFC (even with much shorter fMRI data) is significantly greater than that of FC (calculated from the whole available fMRI data) in three public datasets. Furthermore, we elucidated that the silencing method improved subject discriminability by increasing the test-retest reliability of reliable edges (i.e., edges with high intra-class correlation coefficient) and the reliable edges dominated the subject discriminability of functional brain networks. After silencing, the reliable edges were distributed throughout the brain, especially in the Fronto-parietal Task Control, Salience, Ventral Attention, and Dorsal Attention subnetworks. Finally, the subject discriminability of functional brain networks calculated from task-fMRI data outperformed that calculated from resting-state fMRI data, and the silencing method could significantly improve the subject discriminability of each task-fMRI data, respectively. Conclusion: These results demonstrated that the dFC estimated by the silencing method from FC might constitute an accurate “fingerprint” for subject discriminability. Significance: This study made a step forward to the personalized neuroscience with fMRI-based brain “fingerprint”.
- 9 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2253-2265
Extracting Individual Neural Fingerprint Encoded in Functional Connectivity by Silencing Indirect Effects
Objective: The possibility of subject discriminability based on whole-brain functional connectivity (FC) has been demonstrated. To extract more accurate “fingerprint” encoded in FC, we speculated that the indirect effects in FC might be unfavorable information for subject discriminability, then the remaining component of FC (referred as direct FC (dFC)) may constitute a better “fingerprint.” Methods: We adopted the silencing method to infer dFC from experimentally accessible FC and explained the superiority of dFC in subject discriminability from the perspective of test-retest reliability. Results: We showed that the subject discriminability of dFC (even with much shorter fMRI data) is significantly greater than that of FC (calculated from the whole available fMRI data) in three public datasets. Furthermore, we elucidated that the silencing method improved subject discriminability by increasing the test-retest reliability of reliable edges (i.e., edges with high intra-class correlation coefficient) and the reliable edges dominated the subject discriminability of functional brain networks. After silencing, the reliable edges were distributed throughout the brain, especially in the Fronto-parietal Task Control, Salience, Ventral Attention, and Dorsal Attention subnetworks. Finally, the subject discriminability of functional brain networks calculated from task-fMRI data outperformed that calculated from resting-state fMRI data, and the silencing method could significantly improve the subject discriminability of each task-fMRI data, respectively. Conclusion: These results demonstrated that the dFC estimated by the silencing method from FC might constitute an accurate “fingerprint” for subject discriminability. Significance: This study made a step forward to the personalized neuroscience with fMRI-based brain “fingerprint”.
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (2) , 411-420
Antidepressant-Like Effect of Low-Intensity Transcranial Ultrasound Stimulation
Objective: Transcranial ultrasound stimulation (TUS) is a noninvasive neuromodulation technique with good spatial resolution and deep penetration. This study aims to investigate whether TUS has antidepressant-like effect to depressed rats. Methods: Rats were divided into five groups, including two groups (ST-Ctr and ST-Res) for evaluating the short-term impact of restraint stress and three groups (LT-Ctr-ShamTUS, LT-Res-ShamTUS and LT-Res-TUS) for studying the long-term effects of restraint and TUS stimulation. The TUS-treated rats were subjected to 15 min TUS stimulation to the prelimbic cortex every day for 2 weeks after the restraint. Then depressive symptoms related behavioral outcomes were estimated in ST-Ctr and ST-Res groups (1 week after restraint), as well as in the other three groups (3 weeks after restraint). Results: The 48-hour-restraint stress could lead to long lasting reduction of exploratory behavior (1 and 3 weeks after restraint) and protracted anhedonia (only observed 3 weeks after restraint). TUS application successfully reversed the core depressive phenotype, anhedonia, indicated by significantly higher sucrose preference index in LT-Res-TUS group (88.8%$\times$2.5%, n=16) than LT-Res-ShamTUS group (72.8%$\times$7.2%, n=16) (p=0.046). Furthermore, the BDNF expression in left hippocampus was significantly promoted in LT-Res-TUS group (1.53$\times$0.096, n=5) compared to LT-Res-ShamTUS group (0.79$\times$0.054, n=5) (p=0.009). In addition, the histologic results of H&E staining showed no TUS-induced brain tissue injury. Conclusion: These results demonstrated that low intensity TUS had antidepressant-like effect. Significance: TUS has been speculated to have therapeutic effect in depression. This study provide evidence for the antidepressant-like effects of TUS in rats for the first time.
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (2) , 411-420
Antidepressant-Like Effect of Low-Intensity Transcranial Ultrasound Stimulation
Objective: Transcranial ultrasound stimulation (TUS) is a noninvasive neuromodulation technique with good spatial resolution and deep penetration. This study aims to investigate whether TUS has antidepressant-like effect to depressed rats. Methods: Rats were divided into five groups, including two groups (ST-Ctr and ST-Res) for evaluating the short-term impact of restraint stress and three groups (LT-Ctr-ShamTUS, LT-Res-ShamTUS and LT-Res-TUS) for studying the long-term effects of restraint and TUS stimulation. The TUS-treated rats were subjected to 15 min TUS stimulation to the prelimbic cortex every day for 2 weeks after the restraint. Then depressive symptoms related behavioral outcomes were estimated in ST-Ctr and ST-Res groups (1 week after restraint), as well as in the other three groups (3 weeks after restraint). Results: The 48-hour-restraint stress could lead to long lasting reduction of exploratory behavior (1 and 3 weeks after restraint) and protracted anhedonia (only observed 3 weeks after restraint). TUS application successfully reversed the core depressive phenotype, anhedonia, indicated by significantly higher sucrose preference index in LT-Res-TUS group (88.8%$\times$2.5%, n=16) than LT-Res-ShamTUS group (72.8%$\times$7.2%, n=16) (p=0.046). Furthermore, the BDNF expression in left hippocampus was significantly promoted in LT-Res-TUS group (1.53$\times$0.096, n=5) compared to LT-Res-ShamTUS group (0.79$\times$0.054, n=5) (p=0.009). In addition, the histologic results of H&E staining showed no TUS-induced brain tissue injury. Conclusion: These results demonstrated that low intensity TUS had antidepressant-like effect. Significance: TUS has been speculated to have therapeutic effect in depression. This study provide evidence for the antidepressant-like effects of TUS in rats for the first time.