Anany Dwivedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anany Dwivedi has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Minas Liarokapis
Department of Mechanical and Mechatronics Engineering, New Dexterity Research Group, The University of Auckland, Auckland, New Zealand
17 shared publications - Philipp Beckerle
Chair of Autonomous Systems and Mechatronics, Department of Electrical Engineering, Friedrich-Alexander-Universitt Erlangen-Nrnberg, Erlangen, Germany
5 shared publications - Gal Gorjup
New Dexterity research group, The University of Auckland, New Zealand
3 shared publications - Geng Gao
National Local Joint Engineering Laboratory of Lithium Ion Battery and Material Preparation Technology, Kunming University of Science and Technology, Kunming 650093, China
3 shared publications - Ricardo Vilela de Godoy
Department of Mechanical and Mechatronics Engineering, New Dexterity Research Group, The University of Auckland, Auckland, New Zealand
3 shared publications - Yongje Kwon
New Dexterity Research Group, The University of Auckland, Auckland, New Zealand
3 shared publications
Latest Publications
- 1 May 2026
- Published by Springer Nature
- p. 669-677
Detecting Domain Shifts in Myoelectric Activations: Challenges and Opportunities in Stream Learning
- 1 May 2026
- Published by Springer Nature
- p. 669-677
Detecting Domain Shifts in Myoelectric Activations: Challenges and Opportunities in Stream Learning
- Open Access
- 28 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 903-911
Navigating the Challenges of Wearables: A Case Study of Research-Grade Devices
- 28 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 903-911
Open AccessNavigating the Challenges of Wearables: A Case Study of Research-Grade Devices
- Open Access
Detecting Domain Shifts in Myoelectric Activations: Challenges and Opportunities in Stream Learning
Detecting domain shifts in myoelectric activations poses a significant challenge due to the inherent non-stationarity of electromyography (EMG) signals. This paper explores the detection of domain shifts using data stream (DS) learning techniques, focusing on the DB6 dataset from the Ninapro database. We define domains as distinct time-series segments based on different subjects and recording sessions, applying Kernel Principal Component Analysis (KPCA) with a cosine kernel to pre-process and highlight these shifts. By evaluating multiple drift detection methods such as CUSUM, Page-Hinckley, and ADWIN, we reveal the limitations of current techniques in achieving high performance for real-time domain shift detection in EMG signals. Our results underscore the potential of streaming-based approaches for maintaining stable EMG decoding models, while highlighting areas for further research to enhance robustness and accuracy in real-world scenarios.
Open AccessDetecting Domain Shifts in Myoelectric Activations: Challenges and Opportunities in Stream Learning
Detecting domain shifts in myoelectric activations poses a significant challenge due to the inherent non-stationarity of electromyography (EMG) signals. This paper explores the detection of domain shifts using data stream (DS) learning techniques, focusing on the DB6 dataset from the Ninapro database. We define domains as distinct time-series segments based on different subjects and recording sessions, applying Kernel Principal Component Analysis (KPCA) with a cosine kernel to pre-process and highlight these shifts. By evaluating multiple drift detection methods such as CUSUM, Page-Hinckley, and ADWIN, we reveal the limitations of current techniques in achieving high performance for real-time domain shift detection in EMG signals. Our results underscore the potential of streaming-based approaches for maintaining stable EMG decoding models, while highlighting areas for further research to enhance robustness and accuracy in real-world scenarios.
- Open Access
A Multimodal Bracelet to Acquire Muscular Activity and Gyroscopic Data to Study Sensor Fusion for Intent Detection
Researchers have attempted to control robotic hands and prostheses through biosignals but could not match the human hand. Surface electromyography records electrical muscle activity using non-invasive electrodes and has been the primary method in most studies. While surface electromyography-based hand motion decoding shows promise, it has not yet met the requirements for reliable use. Combining different sensing modalities has been shown to improve hand gesture classification accuracy. This work introduces a multimodal bracelet that integrates a 24-channel force myography system with six commercial surface electromyography sensors, each containing a six-axis inertial measurement unit. The device’s functionality was tested by acquiring muscular activity with the proposed device from five participants performing five different gestures in a random order. A random forest model was then used to classify the performed gestures from the acquired signal. The results confirmed the device’s functionality, making it suitable to study sensor fusion for intent detection in future studies. The results showed that combining all modalities yielded the highest classification accuracies across all participants, reaching on average, effectively reducing misclassifications by 37% and 22% compared to using surface electromyography and force myography individually as input signals, respectively. This demonstrates the potential benefits of sensor fusion for more robust and accurate hand gesture classification and paves the way for advanced control of robotic and prosthetic hands.Open AccessA Multimodal Bracelet to Acquire Muscular Activity and Gyroscopic Data to Study Sensor Fusion for Intent Detection
Researchers have attempted to control robotic hands and prostheses through biosignals but could not match the human hand. Surface electromyography records electrical muscle activity using non-invasive electrodes and has been the primary method in most studies. While surface electromyography-based hand motion decoding shows promise, it has not yet met the requirements for reliable use. Combining different sensing modalities has been shown to improve hand gesture classification accuracy. This work introduces a multimodal bracelet that integrates a 24-channel force myography system with six commercial surface electromyography sensors, each containing a six-axis inertial measurement unit. The device’s functionality was tested by acquiring muscular activity with the proposed device from five participants performing five different gestures in a random order. A random forest model was then used to classify the performed gestures from the acquired signal. The results confirmed the device’s functionality, making it suitable to study sensor fusion for intent detection in future studies. The results showed that combining all modalities yielded the highest classification accuracies across all participants, reaching on average, effectively reducing misclassifications by 37% and 22% compared to using surface electromyography and force myography individually as input signals, respectively. This demonstrates the potential benefits of sensor fusion for more robust and accurate hand gesture classification and paves the way for advanced control of robotic and prosthetic hands. - Open Access
- 23 May 2024
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 8 (6) , 44
A Wearable Bidirectional Human–Machine Interface: Merging Motion Capture and Vibrotactile Feedback in a Wireless Bracelet
Humans interact with the environment through a variety of senses. Touch in particular contributes to a sense of presence, enhancing perceptual experiences, and establishing causal relations between events. Many human–machine interfaces only allow for one-way communication, which does not do justice to the complexity of the interaction. To address this, we developed a bidirectional human–machine interface featuring a bracelet equipped with linear resonant actuators, controlled via a Robot Operating System (ROS) program, to simulate haptic feedback. Further, the wireless interface includes a motion sensor and a sensor to quantify the tightness of the bracelet. Our functional experiments, which compared stimulation with three and five intensity levels, respectively, were performed by four healthy participants in their twenties and thirties. The participants achieved an average accuracy of 88% estimating three vibration intensity levels. While the estimation accuracy for five intensity levels was only 67%, the results indicated a good performance in perceiving relative vibration changes with an accuracy of 82%. The proposed haptic feedback bracelet will facilitate research investigating the benefits of bidirectional human–machine interfaces and the perception of vibrotactile feedback in general by closing the gap for a versatile device that can provide high-density user feedback in combination with sensors for intent detection.
- 23 May 2024
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 8 (6) , 44
Open AccessA Wearable Bidirectional Human–Machine Interface: Merging Motion Capture and Vibrotactile Feedback in a Wireless Bracelet
Humans interact with the environment through a variety of senses. Touch in particular contributes to a sense of presence, enhancing perceptual experiences, and establishing causal relations between events. Many human–machine interfaces only allow for one-way communication, which does not do justice to the complexity of the interaction. To address this, we developed a bidirectional human–machine interface featuring a bracelet equipped with linear resonant actuators, controlled via a Robot Operating System (ROS) program, to simulate haptic feedback. Further, the wireless interface includes a motion sensor and a sensor to quantify the tightness of the bracelet. Our functional experiments, which compared stimulation with three and five intensity levels, respectively, were performed by four healthy participants in their twenties and thirties. The participants achieved an average accuracy of 88% estimating three vibration intensity levels. While the estimation accuracy for five intensity levels was only 67%, the results indicated a good performance in perceiving relative vibration changes with an accuracy of 82%. The proposed haptic feedback bracelet will facilitate research investigating the benefits of bidirectional human–machine interfaces and the perception of vibrotactile feedback in general by closing the gap for a versatile device that can provide high-density user feedback in combination with sensors for intent detection.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (2) , 292-301
How Positioning Wearable Haptic Interfaces on Limbs Influences Virtual Embodiment
With increasing use of computer applications and robotic devices in our everyday life, and with the advent of metaverse, there is an urgent need of developing new types of interfaces that facilitate a more intuitive interaction in physical and virtual space. In this work, we investigate the influence of the location of haptic feedback devices on embodiment of virtual hands and user load during an interactive pick-and-place task. To do this, we conducted a user study with a 3x2 repeated measure experiment design: feedback position is varied between the distal phalanx of the index finger and the thumb, the proximal phalanx of the index finger and the thumb, and the wrist. These conditions of feedback are tested with the stimuli applied synchronously to the participant in one case, and with an additional delay of 350 ms in the second case. The results show that the location of the haptic feedback device does not affect embodiment, whereas the delay, i.e., whether the feedback is applied synchronously or asynchronously, affects embodiment. This suggests that for pick-and-place tasks, haptic feedback devices can be placed on the user's wrist without compromising performance making the hands to remain free, allowing unobstructed hand visibility for precise motion tracking, thereby improving accuracy.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (2) , 292-301
How Positioning Wearable Haptic Interfaces on Limbs Influences Virtual Embodiment
With increasing use of computer applications and robotic devices in our everyday life, and with the advent of metaverse, there is an urgent need of developing new types of interfaces that facilitate a more intuitive interaction in physical and virtual space. In this work, we investigate the influence of the location of haptic feedback devices on embodiment of virtual hands and user load during an interactive pick-and-place task. To do this, we conducted a user study with a 3x2 repeated measure experiment design: feedback position is varied between the distal phalanx of the index finger and the thumb, the proximal phalanx of the index finger and the thumb, and the wrist. These conditions of feedback are tested with the stimuli applied synchronously to the participant in one case, and with an additional delay of 350 ms in the second case. The results show that the location of the haptic feedback device does not affect embodiment, whereas the delay, i.e., whether the feedback is applied synchronously or asynchronously, affects embodiment. This suggests that for pick-and-place tasks, haptic feedback devices can be placed on the user's wrist without compromising performance making the hands to remain free, allowing unobstructed hand visibility for precise motion tracking, thereby improving accuracy.
- Open Access
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 104142-104154
Electromyography Based Gesture Decoding Employing Few-Shot Learning, Transfer Learning, and Training From Scratch
Over the last decade several machine learning (ML) based data-driven approaches have been used for the Electromyography (EMG) based control of prosthetic hands. However, the performance of EMG-based frameworks can be affected by: i) the onset of fatigue due to long data collection sessions, ii) musculoskeletal differences between individuals, and iii) sensor position drifting between different sessions with the same user. To evaluate these aspects, in this work, we compare the performance of EMG-based hand gesture decoding models developed using three approaches. This comparison allows for future works in EMG-based Human-Machine Interfaces development to make more informed ML decisions. First, we trained from scratch a Transformer-based architecture, called Temporal Multi-Channel Vision Transformer (TMC-ViT). For our second approach, we utilized a pre-trained and fine-tuned TMC-ViT model (a transfer learning approach). Finally, for our third approach, we developed a Prototypical Network (a few-shot learning approach). The models are trained in a subject-specific and subject-generic manner for eight subjects and validated employing the 10-fold cross-validation procedure. This study shows that training a deep learning decoding model from scratch in a subject-specific manner leads to higher decoding accuracies when a larger dataset is available. For smaller datasets, subject-generic models, or inter-session models, the few-shot learning approach produces more robust results with better performance, and is more suited to applications where long data collection scenarios are not possible, or where multiple users are intended for the interface. Our findings show that the few-shot learning approach can outperform training a model from scratch in different scenarios.
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 104142-104154
Open AccessElectromyography Based Gesture Decoding Employing Few-Shot Learning, Transfer Learning, and Training From Scratch
Over the last decade several machine learning (ML) based data-driven approaches have been used for the Electromyography (EMG) based control of prosthetic hands. However, the performance of EMG-based frameworks can be affected by: i) the onset of fatigue due to long data collection sessions, ii) musculoskeletal differences between individuals, and iii) sensor position drifting between different sessions with the same user. To evaluate these aspects, in this work, we compare the performance of EMG-based hand gesture decoding models developed using three approaches. This comparison allows for future works in EMG-based Human-Machine Interfaces development to make more informed ML decisions. First, we trained from scratch a Transformer-based architecture, called Temporal Multi-Channel Vision Transformer (TMC-ViT). For our second approach, we utilized a pre-trained and fine-tuned TMC-ViT model (a transfer learning approach). Finally, for our third approach, we developed a Prototypical Network (a few-shot learning approach). The models are trained in a subject-specific and subject-generic manner for eight subjects and validated employing the 10-fold cross-validation procedure. This study shows that training a deep learning decoding model from scratch in a subject-specific manner leads to higher decoding accuracies when a larger dataset is available. For smaller datasets, subject-generic models, or inter-session models, the few-shot learning approach produces more robust results with better performance, and is more suited to applications where long data collection scenarios are not possible, or where multiple users are intended for the interface. Our findings show that the few-shot learning approach can outperform training a model from scratch in different scenarios.
- 2 January 2023
- Published by Springer Nature
- p. 1-13
A Literature-Based Perspective on Human-Centered Design and Evaluation of Interfaces for Virtual Reality in Robotics
- 2 January 2023
- Published by Springer Nature
- p. 1-13
A Literature-Based Perspective on Human-Centered Design and Evaluation of Interfaces for Virtual Reality in Robotics
- Open Access
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 99661-99674
On EMG Based Dexterous Robotic Telemanipulation: Assessing Machine Learning Techniques, Feature Extraction Methods, and Shared Control Schemes
Electromyography (EMG) signals are commonly used for the development of Muscle Machine Interfaces. EMG-based solutions provide intuitive and often hand-free control in a wide range of applications that range from the decoding of human intention in classification tasks to the continuous decoding of human motion employing regression models. In this work, we compare various machine learning and feature extraction methods for the creation of EMG based control frameworks for dexterous robotic telemanipulation. Various models are needed that can decode dexterous, in-hand manipulation motions and perform hand gesture classification in real-time. Three different machine learning methods and eight different time-domain features were evaluated and compared. The performance of the models was evaluated in terms of accuracy and time required to predict a data sample. The model that presented the best performance and prediction time trade-off was used for executing in real-time a telemanipulation task with the New Dexterity Autonomous Robotic Assistance (ARoA) platform (a humanoid robot). Various experiments have been conducted to experimentally validate the efficiency of the proposed methods. The robotic system is shown to successfully complete a series of tasks autonomously as well as to efficiently execute tasks in a shared control manner.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 99661-99674
Open AccessOn EMG Based Dexterous Robotic Telemanipulation: Assessing Machine Learning Techniques, Feature Extraction Methods, and Shared Control Schemes
Electromyography (EMG) signals are commonly used for the development of Muscle Machine Interfaces. EMG-based solutions provide intuitive and often hand-free control in a wide range of applications that range from the decoding of human intention in classification tasks to the continuous decoding of human motion employing regression models. In this work, we compare various machine learning and feature extraction methods for the creation of EMG based control frameworks for dexterous robotic telemanipulation. Various models are needed that can decode dexterous, in-hand manipulation motions and perform hand gesture classification in real-time. Three different machine learning methods and eight different time-domain features were evaluated and compared. The performance of the models was evaluated in terms of accuracy and time required to predict a data sample. The model that presented the best performance and prediction time trade-off was used for executing in real-time a telemanipulation task with the New Dexterity Autonomous Robotic Assistance (ARoA) platform (a humanoid robot). Various experiments have been conducted to experimentally validate the efficiency of the proposed methods. The robotic system is shown to successfully complete a series of tasks autonomously as well as to efficiently execute tasks in a shared control manner.
- Open Access
A Systematic Review of Sensor Fusion Methods Using Peripheral Bio-Signals for Human Intention Decoding
Humans learn about the environment by interacting with it. With an increasing use of computer and virtual applications as well as robotic and prosthetic devices, there is a need for intuitive interfaces that allow the user to have an embodied interaction with the devices they are controlling. Muscle–machine interfaces can provide an intuitive solution by decoding human intentions utilizing myoelectric activations. There are several different methods that can be utilized to develop MuMIs, such as electromyography, ultrasonography, mechanomyography, and near-infrared spectroscopy. In this paper, we analyze the advantages and disadvantages of different myography methods by reviewing myography fusion methods. In a systematic review following the PRISMA guidelines, we identify and analyze studies that employ the fusion of different sensors and myography techniques, while also considering interface wearability. We also explore the properties of different fusion techniques in decoding user intentions. The fusion of electromyography, ultrasonography, mechanomyography, and near-infrared spectroscopy as well as other sensing such as inertial measurement units and optical sensing methods has been of continuous interest over the last decade with the main focus decoding the user intention for the upper limb. From the systematic review, it can be concluded that the fusion of two or more myography methods leads to a better performance for the decoding of a user’s intention. Furthermore, promising sensor fusion techniques for different applications were also identified based on the existing literature.
Open AccessA Systematic Review of Sensor Fusion Methods Using Peripheral Bio-Signals for Human Intention Decoding
Humans learn about the environment by interacting with it. With an increasing use of computer and virtual applications as well as robotic and prosthetic devices, there is a need for intuitive interfaces that allow the user to have an embodied interaction with the devices they are controlling. Muscle–machine interfaces can provide an intuitive solution by decoding human intentions utilizing myoelectric activations. There are several different methods that can be utilized to develop MuMIs, such as electromyography, ultrasonography, mechanomyography, and near-infrared spectroscopy. In this paper, we analyze the advantages and disadvantages of different myography methods by reviewing myography fusion methods. In a systematic review following the PRISMA guidelines, we identify and analyze studies that employ the fusion of different sensors and myography techniques, while also considering interface wearability. We also explore the properties of different fusion techniques in decoding user intentions. The fusion of electromyography, ultrasonography, mechanomyography, and near-infrared spectroscopy as well as other sensing such as inertial measurement units and optical sensing methods has been of continuous interest over the last decade with the main focus decoding the user intention for the upper limb. From the systematic review, it can be concluded that the fusion of two or more myography methods leads to a better performance for the decoding of a user’s intention. Furthermore, promising sensor fusion techniques for different applications were also identified based on the existing literature.