Roy Murray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roy Murray has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Neil M. Zimmerman
National Institute of Standards and Technology 1 , Gaithersburg, Maryland 20899, USA
3 shared publications - Justin K. Perron
Department of Physics, California State University San Marcos , San Marcos, California 92096
2 shared publications Nopporn Rujisamphan
2 shared publications- Syed Ismat Shah
Department of Physics and Astronomy, University of Delaware 2 , Newark, Delaware 19716
2 shared publications Antonio L. Levy
National Institute of Standards and Technology 1 , Gaithersburg, Maryland 20899, USA
1 shared publicationB. Sarabi
National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA
1 shared publication
Latest Publications
- Open Access
- 2 March 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (9) , 094301
Results and model for single-gate ratchet charge pumping
We show experimentally that, in the same Si devices, we can demonstrate multiple two-gate pumping modes but not single-gate mode. We contrast this with GaAs devices, which do show single-gate pumping at a high yield. We propose four mechanisms to explain the lack of plateaus in the Si devices in single-gate ratchet mode: operating the dot with a large number of electrons, a large ratio between the change in electrochemical potential energy and the change in the energy of the barrier (plunger-to-barrier ratio, Δptb) compared to the charging energy (Δptb/EC), nonlinear tunnel barriers, and phase offset leading to nonequilibrium heating. Our analysis shows that each of these could contribute to the lack of plateaus in single-gate ratchet pumping on Si devices but allow two-gate pumping methods to work with robust plateaus. It is easier for GaAs pumps to avoid these failure mechanisms due to their different architectures and cleaner gate turnoff curves. We propose several methods to reduce these sources of error, including reducing cross capacitances between gates. These recommendations may prove useful to other researchers in producing more robust, higher yield single-gate ratchet pumps.
- 2 March 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (9) , 094301
Open AccessResults and model for single-gate ratchet charge pumping
We show experimentally that, in the same Si devices, we can demonstrate multiple two-gate pumping modes but not single-gate mode. We contrast this with GaAs devices, which do show single-gate pumping at a high yield. We propose four mechanisms to explain the lack of plateaus in the Si devices in single-gate ratchet mode: operating the dot with a large number of electrons, a large ratio between the change in electrochemical potential energy and the change in the energy of the barrier (plunger-to-barrier ratio, Δptb) compared to the charging energy (Δptb/EC), nonlinear tunnel barriers, and phase offset leading to nonequilibrium heating. Our analysis shows that each of these could contribute to the lack of plateaus in single-gate ratchet pumping on Si devices but allow two-gate pumping methods to work with robust plateaus. It is easier for GaAs pumps to avoid these failure mechanisms due to their different architectures and cleaner gate turnoff curves. We propose several methods to reduce these sources of error, including reducing cross capacitances between gates. These recommendations may prove useful to other researchers in producing more robust, higher yield single-gate ratchet pumps.
- Open Access
- 21 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Long-term drift of Si-MOS quantum dots with intentional donor implants
Charge noise can be detrimental to the operation of quantum dot (QD) based semiconductor qubits. We study the low-frequency charge noise by charge offset drift measurements for Si-MOS devices with intentionally implanted donors near the QDs. We show that the MOS system exhibits non-equilibrium drift characteristics, in the form of transients and discrete jumps, that are not dependent on the properties of the donor implants. The equilibrium charge noise indicates a 1/f noise dependence, and a noise strength as low as $$1\,\mu {\rm{eV}}/\sqrt{{\rm{Hz}}}$$ , comparable to that reported in more model GaAs and Si/SiGe systems (which have also not been implanted). We demonstrate that implanted qubits, therefore, can be fabricated without detrimental effects on long-term drift or 1/f noise for devices with less than 50 implanted donors near the qubit.- 21 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Open AccessLong-term drift of Si-MOS quantum dots with intentional donor implants
Charge noise can be detrimental to the operation of quantum dot (QD) based semiconductor qubits. We study the low-frequency charge noise by charge offset drift measurements for Si-MOS devices with intentionally implanted donors near the QDs. We show that the MOS system exhibits non-equilibrium drift characteristics, in the form of transients and discrete jumps, that are not dependent on the properties of the donor implants. The equilibrium charge noise indicates a 1/f noise dependence, and a noise strength as low as $$1\,\mu {\rm{eV}}/\sqrt{{\rm{Hz}}}$$ , comparable to that reported in more model GaAs and Si/SiGe systems (which have also not been implanted). We demonstrate that implanted qubits, therefore, can be fabricated without detrimental effects on long-term drift or 1/f noise for devices with less than 50 implanted donors near the qubit. - Open Access
- 8 January 2018
- Published by IOP Publishing in Nanotechnology
- Vol. 29 (6) , 065202
AC signal characterization for optimization of a CMOS single-electron pump
Pumping single electrons at a set rate is being widely pursued as an electrical current standard. Semiconductor charge pumps have been pursued in a variety of modes, including single gate ratchet, a variety of 2-gate ratchet pumps, and 2-gate turnstiles. Whether pumping with one or two AC signals, lower error rates can result from better knowledge of the properties of the AC signal at the device. In this work, we operated a CMOS single-electron pump with a 2-gate ratchet style measurement and used the results to characterize and optimize our two AC signals. Fitting this data at various frequencies revealed both a difference in signal path length and attenuation between our two AC lines. Using this data, we corrected for the difference in signal path length and attenuation by applying an offset in both the phase and the amplitude at the signal generator. Operating the device as a turnstile while using the optimized parameters determined from the 2-gate ratchet measurement led to much flatter, more robust charge pumping plateaus. This method was useful in tuning our device up for optimal charge pumping, and may prove useful to the semiconductor quantum dot community to determine signal attenuation and path differences at the device.
- 8 January 2018
- Published by IOP Publishing in Nanotechnology
- Vol. 29 (6) , 065202
Open AccessAC signal characterization for optimization of a CMOS single-electron pump
Pumping single electrons at a set rate is being widely pursued as an electrical current standard. Semiconductor charge pumps have been pursued in a variety of modes, including single gate ratchet, a variety of 2-gate ratchet pumps, and 2-gate turnstiles. Whether pumping with one or two AC signals, lower error rates can result from better knowledge of the properties of the AC signal at the device. In this work, we operated a CMOS single-electron pump with a 2-gate ratchet style measurement and used the results to characterize and optimize our two AC signals. Fitting this data at various frequencies revealed both a difference in signal path length and attenuation between our two AC lines. Using this data, we corrected for the difference in signal path length and attenuation by applying an offset in both the phase and the amplitude at the signal generator. Operating the device as a turnstile while using the optimized parameters determined from the 2-gate ratchet measurement led to much flatter, more robust charge pumping plateaus. This method was useful in tuning our device up for optimal charge pumping, and may prove useful to the semiconductor quantum dot community to determine signal attenuation and path differences at the device.
- 1 March 2015
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 134, 231-235
Predicting current from cross section images of organic photovoltaic devices
- 1 March 2015
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 134, 231-235
Predicting current from cross section images of organic photovoltaic devices
- 1 December 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (11) , 114514
Analysis of voltage and temperature dependent photocurrent collection in p3ht/pcbm solar cells
Current-voltage (J-V) analysis of poly (3-hexylthiophene) (P3HT) and phenyl-C61-butyric acid methyl ester (PCBM) blend organic solar cells (OSC) at various temperatures has been recorded and analyzed. The photovoltaic parameters extracted from a lumped circuit analysis completely describe the illuminated J-V data from far reverse bias to beyond the open circuit voltage (Voc). A simple model for carrier collection, previously applied to inorganic thin film solar cells, has been used to describe the voltage dependence of the photocurrent, JL(V), with only one adjustable parameter, Lc/D, the ratio of the carrier collection length to the active-layer thickness. Measured J-V curves of a variety of OSCs with varying thickness and blend ratios are closely fit with this model. Effect of resistive and collection losses has been quantified and removed, allowing the intrinsic junction behavior to be uncovered. The temperature dependence of Voc is linear with negative temperature coefficient, dVoc/dT,∼ −1 mV/K. The values of the effective bandgap of the blend obtained from the intercept at T = 0 K decrease with the increase of the PCBM concentration. Our data support the idea of existence of mid-bandgap states, which increase with the increase in the disorder in the active layer.
- 1 December 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (11) , 114514
Analysis of voltage and temperature dependent photocurrent collection in p3ht/pcbm solar cells
Current-voltage (J-V) analysis of poly (3-hexylthiophene) (P3HT) and phenyl-C61-butyric acid methyl ester (PCBM) blend organic solar cells (OSC) at various temperatures has been recorded and analyzed. The photovoltaic parameters extracted from a lumped circuit analysis completely describe the illuminated J-V data from far reverse bias to beyond the open circuit voltage (Voc). A simple model for carrier collection, previously applied to inorganic thin film solar cells, has been used to describe the voltage dependence of the photocurrent, JL(V), with only one adjustable parameter, Lc/D, the ratio of the carrier collection length to the active-layer thickness. Measured J-V curves of a variety of OSCs with varying thickness and blend ratios are closely fit with this model. Effect of resistive and collection losses has been quantified and removed, allowing the intrinsic junction behavior to be uncovered. The temperature dependence of Voc is linear with negative temperature coefficient, dVoc/dT,∼ −1 mV/K. The values of the effective bandgap of the blend obtained from the intercept at T = 0 K decrease with the increase of the PCBM concentration. Our data support the idea of existence of mid-bandgap states, which increase with the increase in the disorder in the active layer.
- 16 November 2012
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 109, 56-62
Focused ion beam assisted investigations of Al interface in polythiophene:Fullerene solar cells
- 16 November 2012
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 109, 56-62
Focused ion beam assisted investigations of Al interface in polythiophene:Fullerene solar cells
- 1 December 2009
- Published by Office of Scientific and Technical Information (OSTI)
A calibration to predict the concentrations of impurities in plutonium oxide by prompt gamma analysis: Revision 1
Over 5,500 containers of excess plutonium-bearing materials have been packaged for long-term storage following the requirements of DOE-STD- 3013. Knowledge of the chemical impurities in the packaged materials is important because certain impurities, such as chloride salts, affect the behavior of the material in storage leading to gas generation and corrosion when sufficient moisture also is present. In most cases, the packaged materials are not well characterized, and information about the chemical impurities is limited to knowledge of the material’s processing history. The alpha-particle activity from the plutonium and americium isotopes provides a method of nondestructive self-interrogation to identify certain light elements through the characteristic, prompt gamma rays that are emitted from alpha-particle-induced reactions with these elements. Gamma-ray spectra are obtained for each 3013 container using a highresolution, coaxial high-purity germanium detector. These gamma-ray spectra are scanned from 800 to 5,000 keV for characteristic, prompt gamma rays from the detectable elements, which include lithium, beryllium, boron, nitrogen, oxygen, fluorine, sodium, magnesium, aluminum, silicon, phosphorus, chlorine, and potassium. The lower limits of detection for these elements in a plutonium-oxide matrix increase with atomic number and range from 100 or 200 ppm for the lightest elements such as lithium and beryllium, tomore » 19,000 ppm for potassium. The peak areas from the characteristic, prompt gamma rays can be used to estimate the concentration of the light-element impurities detected in the material on a semiquantitative basis. The use of prompt gamma analysis to assess impurity concentrations avoids the expense and the risks generally associated with performing chemical analysis on radioactive materials. The analyzed containers are grouped by impurity content, which helps to identify high-risk containers for surveillance and in sorting materials before packaging. « less
- 1 December 2009
- Published by Office of Scientific and Technical Information (OSTI)
A calibration to predict the concentrations of impurities in plutonium oxide by prompt gamma analysis: Revision 1
Over 5,500 containers of excess plutonium-bearing materials have been packaged for long-term storage following the requirements of DOE-STD- 3013. Knowledge of the chemical impurities in the packaged materials is important because certain impurities, such as chloride salts, affect the behavior of the material in storage leading to gas generation and corrosion when sufficient moisture also is present. In most cases, the packaged materials are not well characterized, and information about the chemical impurities is limited to knowledge of the material’s processing history. The alpha-particle activity from the plutonium and americium isotopes provides a method of nondestructive self-interrogation to identify certain light elements through the characteristic, prompt gamma rays that are emitted from alpha-particle-induced reactions with these elements. Gamma-ray spectra are obtained for each 3013 container using a highresolution, coaxial high-purity germanium detector. These gamma-ray spectra are scanned from 800 to 5,000 keV for characteristic, prompt gamma rays from the detectable elements, which include lithium, beryllium, boron, nitrogen, oxygen, fluorine, sodium, magnesium, aluminum, silicon, phosphorus, chlorine, and potassium. The lower limits of detection for these elements in a plutonium-oxide matrix increase with atomic number and range from 100 or 200 ppm for the lightest elements such as lithium and beryllium, tomore » 19,000 ppm for potassium. The peak areas from the characteristic, prompt gamma rays can be used to estimate the concentration of the light-element impurities detected in the material on a semiquantitative basis. The use of prompt gamma analysis to assess impurity concentrations avoids the expense and the risks generally associated with performing chemical analysis on radioactive materials. The analyzed containers are grouped by impurity content, which helps to identify high-risk containers for surveillance and in sorting materials before packaging. « less