Clarisse Mariet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Clarisse Mariet has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Gérard Cote
PSL Research University
6 shared publications André Gaudry
CNRS-CEA
3 shared publicationsAxel Vansteene
Den−Service d’Etudes Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Saclay, F-91191, Gif sur Yvette, France
3 shared publicationsGwendolyne Hellé
CEA Saclay, DEN/DANS/DPC/SEARS/LANIE
3 shared publicationsJean-Philippe Jasmin
Den−Service d’Etudes Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Saclay, F-91191, Gif sur Yvette, France
3 shared publications- Sophie Ayrault
LSCE-IPSL, UMR 8212 (CEA/CNRS/UVSQ), Université Paris-Saclay, F-91191 Gif-sur-Yvette, France
3 shared publications
Latest Publications
- 1 June 2018
- Published by Elsevier in Reactive and Functional Polymers
- Vol. 127, 48-54
Design of experiments as tools to tailor impregnated polymers specific for radionuclides separation in microsystems
- 1 June 2018
- Published by Elsevier in Reactive and Functional Polymers
- Vol. 127, 48-54
Design of experiments as tools to tailor impregnated polymers specific for radionuclides separation in microsystems
- 31 May 2018
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 22 (6) , 61
Towards chip prototyping: a model for droplet formation at both T and X-junctions in dripping regime
- 31 May 2018
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 22 (6) , 61
Towards chip prototyping: a model for droplet formation at both T and X-junctions in dripping regime
- 13 April 2017
- Published by Taylor & Francis in Solvent Extraction and Ion Exchange
- Vol. 35 (3) , 174-186
A Simple and Adaptive Methodology to Use a Commercial Solvent Extraction Microsystem as Screening Tool: Validation with the U-TBP Chemical System
The solvent extraction of a U (VI) present at several g.L−1 from the aqueous phase [HNO3] = 3 M to the organic one (30% TBP) involves a change of the viscosity of the two phases during the extraction process in microsystem. This shifts the position of the interface between the two phases and then affects the quality of the separation at the outlet of the microsystem. The aim of this study is to present a simple method to stabilize the quality of the separation by controlling the interface position during solvent extraction in microsystem. First, a study at low concentration is operated in order to set flow rates and contact time that allow optimal parallel flows and mass transfer. Second, the influence of the high grade concentration (up to 140 g.L−1) of solute on the flows and extraction yield is studied.
- 13 April 2017
- Published by Taylor & Francis in Solvent Extraction and Ion Exchange
- Vol. 35 (3) , 174-186
A Simple and Adaptive Methodology to Use a Commercial Solvent Extraction Microsystem as Screening Tool: Validation with the U-TBP Chemical System
The solvent extraction of a U (VI) present at several g.L−1 from the aqueous phase [HNO3] = 3 M to the organic one (30% TBP) involves a change of the viscosity of the two phases during the extraction process in microsystem. This shifts the position of the interface between the two phases and then affects the quality of the separation at the outlet of the microsystem. The aim of this study is to present a simple method to stabilize the quality of the separation by controlling the interface position during solvent extraction in microsystem. First, a study at low concentration is operated in order to set flow rates and contact time that allow optimal parallel flows and mass transfer. Second, the influence of the high grade concentration (up to 140 g.L−1) of solute on the flows and extraction yield is studied.
- Open Access
- 10 March 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (3) , 45
Photochemical Synthesis and Versatile Functionalization Method of a Robust Porous Poly(ethylene glycol methacrylate-co-allyl methacrylate) Monolith Dedicated to Radiochemical Separation in a Centrifugal Microfluidic Platform
The use of a centrifugal microfluidic platform is an alternative to classical chromatographic procedures for radiochemistry. An ion-exchange support with respect to the in situ light-addressable process of elaboration is specifically designed to be incorporated as a radiochemical sample preparation module in centrifugal microsystem devices. This paper presents a systematic study of the synthesis of the polymeric porous monolith poly(ethylene glycol methacrylate-co-allyl methacrylate) used as a solid-phase support and the versatile and robust photografting process of the monolith based on thiol-ene click chemistry. The polymerization reaction is investigated, varying the formulation of the polymerisable mixture. The robustness of the stationary phase was tested in concentrated nitric acid. Thanks to their unique “easy-to-use” features, centrifugal microfluidic platforms are potential successful candidates for the downscaling of chromatographic separation of radioactive samples (automation, multiplexing, easy integration in glove-boxes environment, and low cost of maintenance).
- 10 March 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (3) , 45
Open AccessPhotochemical Synthesis and Versatile Functionalization Method of a Robust Porous Poly(ethylene glycol methacrylate-co-allyl methacrylate) Monolith Dedicated to Radiochemical Separation in a Centrifugal Microfluidic Platform
The use of a centrifugal microfluidic platform is an alternative to classical chromatographic procedures for radiochemistry. An ion-exchange support with respect to the in situ light-addressable process of elaboration is specifically designed to be incorporated as a radiochemical sample preparation module in centrifugal microsystem devices. This paper presents a systematic study of the synthesis of the polymeric porous monolith poly(ethylene glycol methacrylate-co-allyl methacrylate) used as a solid-phase support and the versatile and robust photografting process of the monolith based on thiol-ene click chemistry. The polymerization reaction is investigated, varying the formulation of the polymerisable mixture. The robustness of the stationary phase was tested in concentrated nitric acid. Thanks to their unique “easy-to-use” features, centrifugal microfluidic platforms are potential successful candidates for the downscaling of chromatographic separation of radioactive samples (automation, multiplexing, easy integration in glove-boxes environment, and low cost of maintenance).
- 12 September 2015
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 19 (5) , 1245-1257
Toward numerical prototyping of labs-on-chip: modeling for liquid–liquid microfluidic devices for radionuclide extraction
- 12 September 2015
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 19 (5) , 1245-1257
Toward numerical prototyping of labs-on-chip: modeling for liquid–liquid microfluidic devices for radionuclide extraction
- 10 May 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (6) , 1113-1128
Liquid–liquid microflow patterns and mass transfer of radionuclides in the systems Eu(III)/HNO3/DMDBTDMA and U(VI)/HCl/Aliquat® 336
- 10 May 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (6) , 1113-1128
Liquid–liquid microflow patterns and mass transfer of radionuclides in the systems Eu(III)/HNO3/DMDBTDMA and U(VI)/HCl/Aliquat® 336
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-162
Liquid-liquid two-phase microflow patterns and mass transfer of radionuclides
Two phases (liquid-liquid extraction) stratified flows in a rectangular geometry are analyzed in a double-Y shape glass chip. The influence of physical properties, in particular the viscosity of the two liquids affects the microflow. The extraction conditions (acid concentrations, contact times) in batch and in the microfluidic device were considered for a liquid anion exchanger and a neutral extractant for the extraction of U(VI) and Eu(III), respectively. From the relationship between the outlet analyte concentrations and the contact times, the initial rate constants are determined for U(VI) and Eu(III).
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-162
Liquid-liquid two-phase microflow patterns and mass transfer of radionuclides
Two phases (liquid-liquid extraction) stratified flows in a rectangular geometry are analyzed in a double-Y shape glass chip. The influence of physical properties, in particular the viscosity of the two liquids affects the microflow. The extraction conditions (acid concentrations, contact times) in batch and in the microfluidic device were considered for a liquid anion exchanger and a neutral extractant for the extraction of U(VI) and Eu(III), respectively. From the relationship between the outlet analyte concentrations and the contact times, the initial rate constants are determined for U(VI) and Eu(III).