Mohd Azlan Ismail
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohd Azlan Ismail has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Al Khalid Othman
Universiti Malaysia Sarawak
3 shared publications - Hushairi Zen
Universiti Malaysia Sarawak
3 shared publications
Latest Publications
- 1 April 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 833, 11-18
Numerical Investigation of Rotational Speed on Pump as Turbine for Microhydro Applications
Pump as Turbine (PAT) always has been a favourable solution to generate electricity in rural areas when there is a potential microhydro site. Such systems have lower capital cost, and they are easier to maintain than commercially-available microhydro turbines. Normally, PAT is designed to run at a rated rotational speed so it can directly couple with an induction generator in order to match the synchronous speed. In an actual scenario, the PAT’s rotational speed changes and fluctuates with respect to flow rate due to the absence of a hydraulic control mechanism. It is essential to understand how the PAT behaves under different rotational speeds in order to design good microhydro systems. The aim of this study was to conduct simulation analysis of the effect of rotational speed on PAT’s performance curve over a range of flow rates. ANSYS CFX software was used as the Computational Fluid Dynamic (CFD) simulation tool in this study. Three distinct flow domains was modelled by Computer Aided Design (CAD) software and assembled as the computational fluid domains. Mesh independence analysis and convergence criteria were set to ensure the accuracy of the model. The torque generated by the impeller was collected from the simulation data and presented in the PAT performance curve. It was observed that the pressure head and torque generated increased at higher rotational speeds, thus maintaining the efficiency value. The results showed that the efficiency of the PAT was maintained around 76.5% for rotational speeds between 1350 to 1650 RPM, but the best efficiency point shifted to lower flow rate for lower rotational speed. The outcomes of this study will be useful for turbomachinery researchers, microhydro users, and project engineers for predicting the PAT performance for designing microhydro systems.
- 1 April 2016
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 833, 11-18
Numerical Investigation of Rotational Speed on Pump as Turbine for Microhydro Applications
Pump as Turbine (PAT) always has been a favourable solution to generate electricity in rural areas when there is a potential microhydro site. Such systems have lower capital cost, and they are easier to maintain than commercially-available microhydro turbines. Normally, PAT is designed to run at a rated rotational speed so it can directly couple with an induction generator in order to match the synchronous speed. In an actual scenario, the PAT’s rotational speed changes and fluctuates with respect to flow rate due to the absence of a hydraulic control mechanism. It is essential to understand how the PAT behaves under different rotational speeds in order to design good microhydro systems. The aim of this study was to conduct simulation analysis of the effect of rotational speed on PAT’s performance curve over a range of flow rates. ANSYS CFX software was used as the Computational Fluid Dynamic (CFD) simulation tool in this study. Three distinct flow domains was modelled by Computer Aided Design (CAD) software and assembled as the computational fluid domains. Mesh independence analysis and convergence criteria were set to ensure the accuracy of the model. The torque generated by the impeller was collected from the simulation data and presented in the PAT performance curve. It was observed that the pressure head and torque generated increased at higher rotational speeds, thus maintaining the efficiency value. The results showed that the efficiency of the PAT was maintained around 76.5% for rotational speeds between 1350 to 1650 RPM, but the best efficiency point shifted to lower flow rate for lower rotational speed. The outcomes of this study will be useful for turbomachinery researchers, microhydro users, and project engineers for predicting the PAT performance for designing microhydro systems.
- Open Access
- 1 July 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 773-774, 358-362
Numerical Simulation on End Suction Centrifugal Pump Running in Inverse Flow for Microhydro Applications
The initial capital cost for most microhydro projects has always been an overriding issue for self-funded remote communities. The cost will escalate significantly in the absence of local microhydro electromechanical manufacturers. The application of end suction centrifugal pump as turbine will reduce the overall cost, which renders microhydro systems feasible for self-funded projects and are therefore suitable for rural communities. The goal of this study is to design and develop a pump as turbine (PAT) which serves as a substitute to commercial electromechanical components. Numerical analysis of an inverse flow for an end suction centrifugal pump is presented in this paper, which includes the performance curves and hydraulic characteristics of the pump. ANSYS CFX, a commercial CFD software is used to simulate the performance of the pump with specific speed, Ns of 70 units (Euroflo EU50-20). The computational flow domain inside the pump is comprises of impeller, volute and draft tube. Unstructured tetrahedral mesh is used to maintain good surface mesh due to complex flow domain geometries. The governing equations used in the simulations are three-dimensional, incompressible Navier-Stokes and k-ϵ turbulence model under steady-state condition. The simulation results are compared with pump performance curve supplied by the pump manufacturer. The verification results show good agreement for flow rates between 0.7 and 1.3 QBEP. The best efficient point (BEP) for inverse flow is attained at a higher head and flow rate compared to pump mode, whereby the value is found to be 21.55 m and 14.0 l/s, respectively. It is believed that the findings of this study will be useful to predict hydraulic characteristics and performance curves of PAT and the model may be used to identify poor flow characteristics inside the pump. It is recommended that optimization process is carried out using CFD tools in future studies.
- 1 July 2015
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 773-774, 358-362
Open AccessNumerical Simulation on End Suction Centrifugal Pump Running in Inverse Flow for Microhydro Applications
The initial capital cost for most microhydro projects has always been an overriding issue for self-funded remote communities. The cost will escalate significantly in the absence of local microhydro electromechanical manufacturers. The application of end suction centrifugal pump as turbine will reduce the overall cost, which renders microhydro systems feasible for self-funded projects and are therefore suitable for rural communities. The goal of this study is to design and develop a pump as turbine (PAT) which serves as a substitute to commercial electromechanical components. Numerical analysis of an inverse flow for an end suction centrifugal pump is presented in this paper, which includes the performance curves and hydraulic characteristics of the pump. ANSYS CFX, a commercial CFD software is used to simulate the performance of the pump with specific speed, Ns of 70 units (Euroflo EU50-20). The computational flow domain inside the pump is comprises of impeller, volute and draft tube. Unstructured tetrahedral mesh is used to maintain good surface mesh due to complex flow domain geometries. The governing equations used in the simulations are three-dimensional, incompressible Navier-Stokes and k-ϵ turbulence model under steady-state condition. The simulation results are compared with pump performance curve supplied by the pump manufacturer. The verification results show good agreement for flow rates between 0.7 and 1.3 QBEP. The best efficient point (BEP) for inverse flow is attained at a higher head and flow rate compared to pump mode, whereby the value is found to be 21.55 m and 14.0 l/s, respectively. It is believed that the findings of this study will be useful to predict hydraulic characteristics and performance curves of PAT and the model may be used to identify poor flow characteristics inside the pump. It is recommended that optimization process is carried out using CFD tools in future studies.
- 3 November 2014
- Published by ABC Journals in Asia Pacific Journal of Energy and Environment
- Vol. 1 (3) , 182
An Economic Evaluation of Electromechanical Components for Microhydro in Borneo – Case Study
- 3 November 2014
- Published by ABC Journals in Asia Pacific Journal of Energy and Environment
- Vol. 1 (3) , 182
An Economic Evaluation of Electromechanical Components for Microhydro in Borneo – Case Study