Borna K. Barth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Borna K. Barth has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Olivio F. Donati
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
3 shared publications- Hatem Alkadhi
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
2 shared publications - Katharina Martini
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Switzerland
2 shared publications - Stephan Baumueller
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich/University Zurich, Rämistrasse 100, CH-8091 Zürich, Switzerland
2 shared publications - Thomas Frauenfelder
Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich , Zurich
2 shared publications Alexander Cornelius
Aarau, Switzerland
1 shared publication
Latest Publications
- Open Access
- 26 March 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (8) , 4002-4013
Value of bowel preparation techniques for prostate MRI: a preliminary study
Background: Bowel preparation before multiparametric MRI (mpMRI) of the prostate is performed widely, despite contradictory or no evidence for efficacy. Purpose: To investigate the value of hyoscine N-butylbromide (HBB), microenema (ME) and ‘dietary restrictions’ (DR) for artifact reduction and image quality (IQ) in mpMRI of the prostate. Study type: Retrospective. Population: Between 10/2018 and 02/2020 treatment-naïve men (median age, 64.9; range 39.8–87.3) who underwent mpMRI of the prostate were included. The total patient sample comprised of n = 180 patients, who received either HBB, ME, were instructed to adhere to DR, or received a combination of those measures prior to the MR scan. Field strength/sequence: T2-weighted imaging (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced MRI (DCE-MRI) scanned on two 3T systems. Assessment: A radiologist specialized in urogenital imaging (R1) and a senior radiology resident (R2) visually assessed IQ parameters on transversal T2w, DWI and ADC maps on a 5-point Likert-like scale. Statistical tests: Group comparison between IQ parameters was performed on reader level using Kruskal–Wallis and Mann–Whitney U tests. Binary univariate logistic regression analysis was used to assess independent predictors of IQ. Interrater agreement was assessed using Intraclass Correlation Coefficient (ICC). Results: ‘DWI geometric distortion’ was significantly more pronounced in the HBB+/ME−/DR− (R1, 3.6 and R2, 4.0) as compared to the HBB−/ME+/DR− (R1, 4.2 and R2, 4.6) and HBB+/ME+/DR− (R1, 4.3 and R2, 4.7) cohort, respectively. Parameters ‘DWI IQ’ and ‘Whole MRI IQ’ were rated similarly by both readers. ME was a significant independent predictor of ‘good IQ’ for the whole MRI for R1 [b = 1.09, OR 2.98 (95% CI 1.29, 6.87)] and R2 [b = 1.01, OR 2.73 (95% CI 1.24, 6.04)], respectively. Data conclusion: ME seems to significantly improve image quality of DWI and the whole mpMRI image set of the prostate. HBB and DR did not have any benefit.
- 26 March 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (8) , 4002-4013
Open AccessValue of bowel preparation techniques for prostate MRI: a preliminary study
Background: Bowel preparation before multiparametric MRI (mpMRI) of the prostate is performed widely, despite contradictory or no evidence for efficacy. Purpose: To investigate the value of hyoscine N-butylbromide (HBB), microenema (ME) and ‘dietary restrictions’ (DR) for artifact reduction and image quality (IQ) in mpMRI of the prostate. Study type: Retrospective. Population: Between 10/2018 and 02/2020 treatment-naïve men (median age, 64.9; range 39.8–87.3) who underwent mpMRI of the prostate were included. The total patient sample comprised of n = 180 patients, who received either HBB, ME, were instructed to adhere to DR, or received a combination of those measures prior to the MR scan. Field strength/sequence: T2-weighted imaging (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced MRI (DCE-MRI) scanned on two 3T systems. Assessment: A radiologist specialized in urogenital imaging (R1) and a senior radiology resident (R2) visually assessed IQ parameters on transversal T2w, DWI and ADC maps on a 5-point Likert-like scale. Statistical tests: Group comparison between IQ parameters was performed on reader level using Kruskal–Wallis and Mann–Whitney U tests. Binary univariate logistic regression analysis was used to assess independent predictors of IQ. Interrater agreement was assessed using Intraclass Correlation Coefficient (ICC). Results: ‘DWI geometric distortion’ was significantly more pronounced in the HBB+/ME−/DR− (R1, 3.6 and R2, 4.0) as compared to the HBB−/ME+/DR− (R1, 4.2 and R2, 4.6) and HBB+/ME+/DR− (R1, 4.3 and R2, 4.7) cohort, respectively. Parameters ‘DWI IQ’ and ‘Whole MRI IQ’ were rated similarly by both readers. ME was a significant independent predictor of ‘good IQ’ for the whole MRI for R1 [b = 1.09, OR 2.98 (95% CI 1.29, 6.87)] and R2 [b = 1.01, OR 2.73 (95% CI 1.24, 6.04)], respectively. Data conclusion: ME seems to significantly improve image quality of DWI and the whole mpMRI image set of the prostate. HBB and DR did not have any benefit.
- Open Access
- 1 January 2021
- Published by Elsevier in European Journal of Radiology Open
- Vol. 8, 100332
Value of an online PI-RADS v2.1 score calculator for assessment of prostate MRI
- 1 January 2021
- Published by Elsevier in European Journal of Radiology Open
- Vol. 8, 100332
Open AccessValue of an online PI-RADS v2.1 score calculator for assessment of prostate MRI
- Open Access
- 22 December 2016
- Published by Elsevier in Radiology Case Reports
- Vol. 12 (1) , 39-41
Traumatic nonanastomotic axilloprofundal PTFE-bypass rupture: a case report.
- 22 December 2016
- Published by Elsevier in Radiology Case Reports
- Vol. 12 (1) , 39-41
Open AccessTraumatic nonanastomotic axilloprofundal PTFE-bypass rupture: a case report.
- 1 September 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (9) , 1145-1153
Reliability, Validity, and Reader Acceptance of LI-RADS—An In-depth Analysis
- 1 September 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (9) , 1145-1153
Reliability, Validity, and Reader Acceptance of LI-RADS—An In-depth Analysis
- Open Access
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 195 (4S)
MP16-12 COMPARISON OF IMAGE QUALITY AND PATIENT DISCOMFORT IN PROSTATE MRI: ENDORECTAL COIL VS. PELVIC PHASED ARRAY COIL
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 195 (4S)
Open AccessMP16-12 COMPARISON OF IMAGE QUALITY AND PATIENT DISCOMFORT IN PROSTATE MRI: ENDORECTAL COIL VS. PELVIC PHASED ARRAY COIL
- 1 February 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (2) , 360-365
Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
- 1 February 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (2) , 360-365
Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150389
Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study
Objectives:To investigate the diagnostic performance of advanced modelled iterative reconstruction (ADMIRE) to filtered back projection (FBP) when using an ultralow-dose protocol for the detection of solid and subsolid pulmonary nodules.Methods:Single-energy CT was performed at 100 kVp with tin filtration in an anthropomorphic chest phantom with solid and subsolid pulmonary nodules (2–10 mm, attenuation, 20 to −800 HU at 120 kVp). The mean volume CT dose index (CTDIvol) of the standard chest protocol was 2.2 mGy. Subsequent scans were obtained at 1/8 (0.28 mGy), 1/20 (0.10 mGy) and 1/70 (0.03 mGy) dose levels by lowering tube voltage and tube current. Images were reconstructed with FBP and ADMIRE. One reader measured image noise; two readers determined image quality and assessed nodule localization.Results:Image noise was significantly reduced using ADMIRE compared with FBP (ADMIRE at a strength level of 5 : 70.4% for 1/20; 71.6% for 1/8; p < 0.001). Interobserver agreement for image quality was excellent...
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150389
Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study
Objectives:To investigate the diagnostic performance of advanced modelled iterative reconstruction (ADMIRE) to filtered back projection (FBP) when using an ultralow-dose protocol for the detection of solid and subsolid pulmonary nodules.Methods:Single-energy CT was performed at 100 kVp with tin filtration in an anthropomorphic chest phantom with solid and subsolid pulmonary nodules (2–10 mm, attenuation, 20 to −800 HU at 120 kVp). The mean volume CT dose index (CTDIvol) of the standard chest protocol was 2.2 mGy. Subsequent scans were obtained at 1/8 (0.28 mGy), 1/20 (0.10 mGy) and 1/70 (0.03 mGy) dose levels by lowering tube voltage and tube current. Images were reconstructed with FBP and ADMIRE. One reader measured image noise; two readers determined image quality and assessed nodule localization.Results:Image noise was significantly reduced using ADMIRE compared with FBP (ADMIRE at a strength level of 5 : 70.4% for 1/20; 71.6% for 1/8; p < 0.001). Interobserver agreement for image quality was excellent...