Michael de Podesta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael de Podesta has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
Gavin Sutton
National Physical Laboratory
6 shared publicationsRobin Underwood
National Physical Laboratory
6 shared publicationsRobin J Underwood
5 shared publications- Graham Machin
National Physical Laboratory (NPL), Hampton Road, Teddington, TW11 0LW, UK
4 shared publications R. Underwood
National Physical Laboratory, Teddington TW11 0LW, UK
4 shared publicationsDarren F Mark
Scottish Universities Environmental Research Centre
3 shared publications
Latest Publications
- 27 October 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (3) , 035001
Methodologies and uncertainty estimates for T – T 90 measurements over the temperature range from 430 K to 1358 K under the auspices of the EMPIR InK2 project
We report new developments in instrumentation and techniques for both acoustic (speed of sound) and radiometric primary thermometry methods. These include both new cylindrical resonators for extending acoustic gas thermometry to higher temperatures and absolute radiation thermometers incorporating InGaAs detectors to extend primary radiometry to lower temperatures than can be achieved using Si-detector based instruments. These new approaches have been established in order to determine the difference between thermodynamic temperature, T , and the International Temperature Scale of 1990 (the ITS-90), T 90 , over the temperature range from 430 K to 1358 K as part of the three-year EMPIR project ‘Implementing the new kelvin 2' (InK2). This paper describes the facilities and measurement methodologies for measuring T — T 90 at each of the different institutes, along with an assessment of the target uncertainties. The work is ongoing, but we anticipate that the results of these measurements will ultimately be pooled to provide consensus values of T — T 90 with associated estimated uncertainties. These consensus values will initially feed into the technical annex of the mise en pratique for the definition of the kelvin (MeP-K-19) and, if required, will be used to help to provide a foundation for any future temperature scale.
- 27 October 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (3) , 035001
Methodologies and uncertainty estimates for T – T 90 measurements over the temperature range from 430 K to 1358 K under the auspices of the EMPIR InK2 project
We report new developments in instrumentation and techniques for both acoustic (speed of sound) and radiometric primary thermometry methods. These include both new cylindrical resonators for extending acoustic gas thermometry to higher temperatures and absolute radiation thermometers incorporating InGaAs detectors to extend primary radiometry to lower temperatures than can be achieved using Si-detector based instruments. These new approaches have been established in order to determine the difference between thermodynamic temperature, T , and the International Temperature Scale of 1990 (the ITS-90), T 90 , over the temperature range from 430 K to 1358 K as part of the three-year EMPIR project ‘Implementing the new kelvin 2' (InK2). This paper describes the facilities and measurement methodologies for measuring T — T 90 at each of the different institutes, along with an assessment of the target uncertainties. The work is ongoing, but we anticipate that the results of these measurements will ultimately be pooled to provide consensus values of T — T 90 with associated estimated uncertainties. These consensus values will initially feed into the technical annex of the mise en pratique for the definition of the kelvin (MeP-K-19) and, if required, will be used to help to provide a foundation for any future temperature scale.
- 18 May 2020
- Published by Taylor & Francis
- p. 175-260
Solids: comparison with experiment
I do not know where you are reading this, but I expect that you are close to some solids with extraordinary properties. This is true for me as I write this on my computer. Beneath my fingers is a keyboard made of plastics, some transparent and some opaque. In front of me is a screen made of glass, the reverse of which is coated with solids that glow under bombardment by electrons. Nearby are paper, cloth and wood. I can see metals, some at temperatures in excess of 2000 °C. And 50 centimetres away is a chip of patterned silicon which enables my computer to function. There is also the semi-solid matter I call my body, which possesses the capacity for abstract thought. This diversity of properties makes comparison with the simple models outlined in Chapter 6 particularly difficult. There are so many ‘special cases’ and ‘exceptions’ that it is unusual to find strict numerical agreement between theory and experimental data. However, we will find that often we can understand the order of magnitude of results, and the trends of the results from one material to another. With these limitations on our ambition in mind, let us see what Chapter 7 holds. §7.2, §7.3, and §7.4 Density, Compressibility, Thermal expansivity: We will find that the density of solids reflects the type of bonding present; the compressibility tells us about the pair-potential between atoms; and thermal expansivity tells us about the asymmetry of the pair-potential. Speed of sound: Sound waves in solids are considerably more complex than in gases. However we relegate much of this complexity to Appendix A2 and focus on the trends in the data, allowing us to get a good feel for the factors involved. Heat capacity: The heat capacity of most solid elements at around room temperature can be understood using an exceptionally simple model of a solid. However, the temperature-dependence of the data, and the data which cannot be explained by this model, will lead us to a more realistic model, and a surprising connection to §7.5 on the speed of sound. Electrical properties: The difference in conductivity between metals and insulators is an amazing 20 orders of magnitude. Not surprisingly, we will use quite different models to understand the two categories of solids. More surprising is the simplicity of each of the models that we will use. For metals we will use the free electron model of a solid we discussed in §6.5, and for insulators we will ignore the bonding between the atoms almost entirely! Thermal conductivity: Although simple in principle, the data and the theory are surprisingly complex, and we attempt to understand only the temperature-dependence of the data. Optical properties: In Chapter 2 we said that the refractive index of a material is related to its dielectric constant. Using this result and Newton’s laws of motion we will be able to explain the values, and the variation with wavelength, of the refractive index of transparent solids. Amazing.
- 18 May 2020
- Published by Taylor & Francis
- p. 175-260
Solids: comparison with experiment
I do not know where you are reading this, but I expect that you are close to some solids with extraordinary properties. This is true for me as I write this on my computer. Beneath my fingers is a keyboard made of plastics, some transparent and some opaque. In front of me is a screen made of glass, the reverse of which is coated with solids that glow under bombardment by electrons. Nearby are paper, cloth and wood. I can see metals, some at temperatures in excess of 2000 °C. And 50 centimetres away is a chip of patterned silicon which enables my computer to function. There is also the semi-solid matter I call my body, which possesses the capacity for abstract thought. This diversity of properties makes comparison with the simple models outlined in Chapter 6 particularly difficult. There are so many ‘special cases’ and ‘exceptions’ that it is unusual to find strict numerical agreement between theory and experimental data. However, we will find that often we can understand the order of magnitude of results, and the trends of the results from one material to another. With these limitations on our ambition in mind, let us see what Chapter 7 holds. §7.2, §7.3, and §7.4 Density, Compressibility, Thermal expansivity: We will find that the density of solids reflects the type of bonding present; the compressibility tells us about the pair-potential between atoms; and thermal expansivity tells us about the asymmetry of the pair-potential. Speed of sound: Sound waves in solids are considerably more complex than in gases. However we relegate much of this complexity to Appendix A2 and focus on the trends in the data, allowing us to get a good feel for the factors involved. Heat capacity: The heat capacity of most solid elements at around room temperature can be understood using an exceptionally simple model of a solid. However, the temperature-dependence of the data, and the data which cannot be explained by this model, will lead us to a more realistic model, and a surprising connection to §7.5 on the speed of sound. Electrical properties: The difference in conductivity between metals and insulators is an amazing 20 orders of magnitude. Not surprisingly, we will use quite different models to understand the two categories of solids. More surprising is the simplicity of each of the models that we will use. For metals we will use the free electron model of a solid we discussed in §6.5, and for insulators we will ignore the bonding between the atoms almost entirely! Thermal conductivity: Although simple in principle, the data and the theory are surprisingly complex, and we attempt to understand only the temperature-dependence of the data. Optical properties: In Chapter 2 we said that the refractive index of a material is related to its dielectric constant. Using this result and Newton’s laws of motion we will be able to explain the values, and the variation with wavelength, of the refractive index of transparent solids. Amazing.
- Open Access
- 10 May 2020
- Published by Wiley in Quarterly Journal of the Royal Meteorological Society
- Vol. 146 (731) , 2789-2800
Response times of meteorological air temperature sensors
Guidelines in the Guide to Meteorological Instruments and Methods of Observation (the CIMO guide) of the World Meteorological Organization (WMO, published 2014, updated 2017, section 2.1.3.3, Response times of thermometers) recommend that the 63% response time τ for an air temperature sensor be 20 s, although – as airflow speed influences response time – the minimum airflow speed at which this applies should also be specified in the document. A 63% response time τ63 = 20 s implies that 95% of a step change be registered within 3τ63 or 60 s, the WMO recommended averaging interval for air temperature: rapid air temperature changes on this time‐scale are not uncommon, often associated with convective squalls, frontal systems or sea breeze circulations. An alternative way of expressing the effect of the time constant is that in air whose temperature is changing at 0.1 K·min−1 the thermometer would lag by approximately 0.03 K.To assess whether this response time specification was realistic, we have undertaken an experimental and theoretical study of the time constants of meteorological thermometers. Laboratory wind tunnel tests were undertaken to quantify 63% and 95% response times of 25 commercial 100 Ω platinum resistance thermometers (PRTs) of various sizes (length and sheath diameter) from five manufacturers. The test results revealed a fourfold difference in response times between different sensors: none of the PRTs tested met the CIMO response time guideline at a ventilation speed of 1 m·s−1 assumed typical of passively ventilated thermometer shields such as Stevenson‐type thermometer screens. A theoretical model of the sensors was devised which matched the experimental behaviour with regard to the most important contributing factors, namely ventilation rate and sensor diameter. Finally, suggestions and recommendations for operational air temperature sensor adoption and future sensor development are included.
- 10 May 2020
- Published by Wiley in Quarterly Journal of the Royal Meteorological Society
- Vol. 146 (731) , 2789-2800
Open AccessResponse times of meteorological air temperature sensors
Guidelines in the Guide to Meteorological Instruments and Methods of Observation (the CIMO guide) of the World Meteorological Organization (WMO, published 2014, updated 2017, section 2.1.3.3, Response times of thermometers) recommend that the 63% response time τ for an air temperature sensor be 20 s, although – as airflow speed influences response time – the minimum airflow speed at which this applies should also be specified in the document. A 63% response time τ63 = 20 s implies that 95% of a step change be registered within 3τ63 or 60 s, the WMO recommended averaging interval for air temperature: rapid air temperature changes on this time‐scale are not uncommon, often associated with convective squalls, frontal systems or sea breeze circulations. An alternative way of expressing the effect of the time constant is that in air whose temperature is changing at 0.1 K·min−1 the thermometer would lag by approximately 0.03 K.To assess whether this response time specification was realistic, we have undertaken an experimental and theoretical study of the time constants of meteorological thermometers. Laboratory wind tunnel tests were undertaken to quantify 63% and 95% response times of 25 commercial 100 Ω platinum resistance thermometers (PRTs) of various sizes (length and sheath diameter) from five manufacturers. The test results revealed a fourfold difference in response times between different sensors: none of the PRTs tested met the CIMO response time guideline at a ventilation speed of 1 m·s−1 assumed typical of passively ventilated thermometer shields such as Stevenson‐type thermometer screens. A theoretical model of the sensors was devised which matched the experimental behaviour with regard to the most important contributing factors, namely ventilation rate and sensor diameter. Finally, suggestions and recommendations for operational air temperature sensor adoption and future sensor development are included.
- Open Access
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (12) , 122027
Air temperature measurement challenges in precision metrology
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (12) , 122027
Open AccessAir temperature measurement challenges in precision metrology
- 8 June 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075013
Investigating the adequacy of a low-cost vector network analyser for microwave measurements in quasispherical resonators
Microwave measurements in quasispherical resonators (QSRs) have enabled remarkable improvements in primary gas thermometry, but the expense of vector network analysers (VNAs) restricts wider use of the technique. In this work we compare the performance of a commercially available, low-cost VNA with a fully-featured VNA in microwave resonance measurements in a QSR. For acoustic gas thermometry (AGT) where a relative uncertainty in frequency measurement in an order of 10 −7 is required, we have found that the accuracy of the low-cost VNA is easily sufficient. The use of a +20 dB amplifier was also tested for both VNAs and allowed statistical uncertainties to be reduced by a factor of 5 to 12. The two VNAs showed agreement within 20 × 10 −9 of the absolute frequency of microwave resonances. However, when the low-cost VNA was used with the amplifier, some spurious systematic effects were found which biased the measured resonance frequency at levels below 20 × 10 −9 . These effects were apparent only when the amplifier was used with the low-cost VNA, because, when the amplifier was not used, the statistical uncertainty was much larger than the magnitude of these effects. While the physical cause of these systematic effects is not investigated in the present work, we made observations that could help to estimate their magnitudes. The comparison showed that the low-cost VNA, although being perfectly suitable for the AGT, may not be sufficiently accurate for applications where the required relative uncertainty in the frequency determination is of an order of 10 −9 .
- 8 June 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075013
Investigating the adequacy of a low-cost vector network analyser for microwave measurements in quasispherical resonators
Microwave measurements in quasispherical resonators (QSRs) have enabled remarkable improvements in primary gas thermometry, but the expense of vector network analysers (VNAs) restricts wider use of the technique. In this work we compare the performance of a commercially available, low-cost VNA with a fully-featured VNA in microwave resonance measurements in a QSR. For acoustic gas thermometry (AGT) where a relative uncertainty in frequency measurement in an order of 10 −7 is required, we have found that the accuracy of the low-cost VNA is easily sufficient. The use of a +20 dB amplifier was also tested for both VNAs and allowed statistical uncertainties to be reduced by a factor of 5 to 12. The two VNAs showed agreement within 20 × 10 −9 of the absolute frequency of microwave resonances. However, when the low-cost VNA was used with the amplifier, some spurious systematic effects were found which biased the measured resonance frequency at levels below 20 × 10 −9 . These effects were apparent only when the amplifier was used with the low-cost VNA, because, when the amplifier was not used, the statistical uncertainty was much larger than the magnitude of these effects. While the physical cause of these systematic effects is not investigated in the present work, we made observations that could help to estimate their magnitudes. The comparison showed that the low-cost VNA, although being perfectly suitable for the AGT, may not be sufficiently accurate for applications where the required relative uncertainty in the frequency determination is of an order of 10 −9 .
- Open Access
- 28 February 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (2) , 229-244
Air temperature sensors: dependence of radiative errors on sensor diameter in precision metrology and meteorology
- 28 February 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (2) , 229-244
Open AccessAir temperature sensors: dependence of radiative errors on sensor diameter in precision metrology and meteorology
- 5 February 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (2) , R1-R20
The Boltzmann project
The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10 −23 J K −1 . The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10 −7 , corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k , important for the new definition of the kelvin and performed in the last decade, is given.
- 5 February 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (2) , R1-R20
The Boltzmann project
The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10 −23 J K −1 . The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10 −7 , corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k , important for the new definition of the kelvin and performed in the last decade, is given.
- 18 January 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (2) , 025802
The MeteoMet2 project—highlights and results
Launched in 2011 within the European Metrology Research Programme (EMRP) of EURAMET, the joint research project ‘MeteoMet’—Metrology for Meteorology—is the largest EMRP consortium; national metrology institutes, universities, meteorological and climate agencies, research institutes, collaborators and manufacturers are working together, developing new metrological techniques, as well as improving existing ones, for use in meteorological observations and climate records. The project focuses on humidity in the upper and surface atmosphere, air temperature, surface and deep-sea temperatures, soil moisture, salinity, permafrost temperature, precipitation, and the snow albedo effect on air temperature. All tasks are performed using a rigorous metrological approach and include the design and study of new sensors, new calibration facilities, the investigation of sensor characteristics, improved techniques for measurements of essential climate variables with uncertainty evaluation, traceability, laboratory proficiency and the inclusion of field influencing parameters, long-lasting measurements, and campaigns in remote and extreme areas. The vision for MeteoMet is to take a step further towards establishing full data comparability, coherency, consistency, and long-term continuity, through a comprehensive evaluation of the measurement uncertainties for the quantities involved in the global climate observing systems and the derived observations. The improvement in quality of essential climate variables records, through the inclusion of measurement uncertainty budgets, will also highlight possible strategies for the reduction of the uncertainty. This contribution presents selected highlights of the MeteoMet project and reviews the main ongoing activities, tasks and deliverables, with a view to its possible future evolution and extended impact.
- 18 January 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (2) , 025802
The MeteoMet2 project—highlights and results
Launched in 2011 within the European Metrology Research Programme (EMRP) of EURAMET, the joint research project ‘MeteoMet’—Metrology for Meteorology—is the largest EMRP consortium; national metrology institutes, universities, meteorological and climate agencies, research institutes, collaborators and manufacturers are working together, developing new metrological techniques, as well as improving existing ones, for use in meteorological observations and climate records. The project focuses on humidity in the upper and surface atmosphere, air temperature, surface and deep-sea temperatures, soil moisture, salinity, permafrost temperature, precipitation, and the snow albedo effect on air temperature. All tasks are performed using a rigorous metrological approach and include the design and study of new sensors, new calibration facilities, the investigation of sensor characteristics, improved techniques for measurements of essential climate variables with uncertainty evaluation, traceability, laboratory proficiency and the inclusion of field influencing parameters, long-lasting measurements, and campaigns in remote and extreme areas. The vision for MeteoMet is to take a step further towards establishing full data comparability, coherency, consistency, and long-term continuity, through a comprehensive evaluation of the measurement uncertainties for the quantities involved in the global climate observing systems and the derived observations. The improvement in quality of essential climate variables records, through the inclusion of measurement uncertainty budgets, will also highlight possible strategies for the reduction of the uncertainty. This contribution presents selected highlights of the MeteoMet project and reviews the main ongoing activities, tasks and deliverables, with a view to its possible future evolution and extended impact.
- Open Access
- 10 August 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (5) , 683-692
Re-estimation of argon isotope ratios leading to a revised estimate of the Boltzmann constant
In 2013, NPL, SUERC and Cranfield University published an estimate for the Boltzmann constant (de Podesta et al 2013 Metrologia 50 354–76) based on a measurement of the limiting low-pressure speed of sound in argon gas. Subsequently, an extensive investigation by Yang et al (2015 Metrologia 52 S394–409) revealed that there was likely to have been an error in the estimate of the molar mass of the argon used in the experiment. Responding to Yang et al (2015 Metrologia 52 S394–409), de Podesta et al revised their estimate of the molar mass (de Podesta et al 2015 Metrologia 52 S353–63). The shift in the estimated molar mass, and of the estimate of k B , was large: −2.7 parts in 10 6 , nearly four times the original uncertainty estimate. The work described here was undertaken to understand the cause of this shift and our conclusion is that the original samples were probably contaminated with argon from atmospheric air. In this work we have repeated the measurement reported in de Podesta et al (2013 Metrologia 50 354–76) on the same gas sample that was examined in Yang et al (2015 Metrologia 52 S394–409) and de Podesta et al (2015 Metrologia 52 S353–63). However in this work we have used a different technique for sampling the gas that has allowed us to eliminate the possibility of contamination of the argon samples. We have repeated the sampling procedure three times, and examined samples on two mass spectrometers. This procedure confirms the isotopic ratio estimates of Yang et al (2015 Metrologia 52 S394–409) but with lower uncertainty, particularly in the relative abundance ratio R 38:36 . Our new estimate of the molar mass of the argon used in Isotherm 5 in de Podesta et al (2013 Metrologia 50 354–76) is 39.947 727(15) g mol −1 which differs by +0.50 parts in 10 6 from the estimate 39.947 707(28) g mol −1 made in de Podesta et al (2015 Metrologia 52 S353–63). This new estimate of the molar mass leads to a revised estimate of the Boltzmann constant of k B = 1.380 648 60 (97) × 10 −23 J K −1 which differs from the 2014 CODATA value by +0.05 parts in 10 6 .
- 10 August 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (5) , 683-692
Open AccessRe-estimation of argon isotope ratios leading to a revised estimate of the Boltzmann constant
In 2013, NPL, SUERC and Cranfield University published an estimate for the Boltzmann constant (de Podesta et al 2013 Metrologia 50 354–76) based on a measurement of the limiting low-pressure speed of sound in argon gas. Subsequently, an extensive investigation by Yang et al (2015 Metrologia 52 S394–409) revealed that there was likely to have been an error in the estimate of the molar mass of the argon used in the experiment. Responding to Yang et al (2015 Metrologia 52 S394–409), de Podesta et al revised their estimate of the molar mass (de Podesta et al 2015 Metrologia 52 S353–63). The shift in the estimated molar mass, and of the estimate of k B , was large: −2.7 parts in 10 6 , nearly four times the original uncertainty estimate. The work described here was undertaken to understand the cause of this shift and our conclusion is that the original samples were probably contaminated with argon from atmospheric air. In this work we have repeated the measurement reported in de Podesta et al (2013 Metrologia 50 354–76) on the same gas sample that was examined in Yang et al (2015 Metrologia 52 S394–409) and de Podesta et al (2015 Metrologia 52 S353–63). However in this work we have used a different technique for sampling the gas that has allowed us to eliminate the possibility of contamination of the argon samples. We have repeated the sampling procedure three times, and examined samples on two mass spectrometers. This procedure confirms the isotopic ratio estimates of Yang et al (2015 Metrologia 52 S394–409) but with lower uncertainty, particularly in the relative abundance ratio R 38:36 . Our new estimate of the molar mass of the argon used in Isotherm 5 in de Podesta et al (2013 Metrologia 50 354–76) is 39.947 727(15) g mol −1 which differs by +0.50 parts in 10 6 from the estimate 39.947 707(28) g mol −1 made in de Podesta et al (2015 Metrologia 52 S353–63). This new estimate of the molar mass leads to a revised estimate of the Boltzmann constant of k B = 1.380 648 60 (97) × 10 −23 J K −1 which differs from the 2014 CODATA value by +0.05 parts in 10 6 .
- 25 January 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (1) , S9-S15
An improved non-contact thermometer and hygrometer with rapid response
Previously (Underwood et al 2015 Meteorol. Appl . 22 830 ) we reported first tests of a device capable of simultaneous, non-contact, temperature and humidity (NCTAH) measurements in air. The device used an acoustic thermometer and a tuneable diode laser absorption spectrometer (TDLAS), a combination which should be capable of an extremely rapid response to changes in humidity as it does not require moisture in a solid-state matrix to equilibrate with the surrounding air. In this paper we report recent developments of the instrument focussed on reducing its response time so that it can be used as a reference instrument for assessing the response time of conventional humidity sensors. In addition, the interdependence of the temperature and humidity estimates is now accounted for in real-time using an iterative procedure, which eliminates the need for data post-processing. The TDLAS measures water molecule number density based on the transmission of an infrared beam (approximate wavelength 1360 nm) through a 0.6 m path length. The acoustic thermometer is based around a fixed-path acoustic interferometer. The improved NCTAH device now produces estimates of the water molecule number density every 20 ms and the temperature output displays an RC filter-like response, with a time constant of approximately 30 ms. The instrument has been tested in a climatic chamber through a temperature range of −40 °C to +40 °C and a dew point range of −43 °C to +38 °C, at atmospheric pressure, comparing the instrument readings with those from a calibrated hygrometer and four platinum resistance thermometers. In steady-state conditions, the instrument readings are in good agreement with the conventional sensors, with temperature differences less than 1 °C (repeatability 0.1 °C), and humidity differences mostly within 5% of mixing ratio. Under transient conditions, we demonstrate how the instrument can be used to evaluate the response times of conventional sensors.
- 25 January 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (1) , S9-S15
An improved non-contact thermometer and hygrometer with rapid response
Previously (Underwood et al 2015 Meteorol. Appl . 22 830 ) we reported first tests of a device capable of simultaneous, non-contact, temperature and humidity (NCTAH) measurements in air. The device used an acoustic thermometer and a tuneable diode laser absorption spectrometer (TDLAS), a combination which should be capable of an extremely rapid response to changes in humidity as it does not require moisture in a solid-state matrix to equilibrate with the surrounding air. In this paper we report recent developments of the instrument focussed on reducing its response time so that it can be used as a reference instrument for assessing the response time of conventional humidity sensors. In addition, the interdependence of the temperature and humidity estimates is now accounted for in real-time using an iterative procedure, which eliminates the need for data post-processing. The TDLAS measures water molecule number density based on the transmission of an infrared beam (approximate wavelength 1360 nm) through a 0.6 m path length. The acoustic thermometer is based around a fixed-path acoustic interferometer. The improved NCTAH device now produces estimates of the water molecule number density every 20 ms and the temperature output displays an RC filter-like response, with a time constant of approximately 30 ms. The instrument has been tested in a climatic chamber through a temperature range of −40 °C to +40 °C and a dew point range of −43 °C to +38 °C, at atmospheric pressure, comparing the instrument readings with those from a calibrated hygrometer and four platinum resistance thermometers. In steady-state conditions, the instrument readings are in good agreement with the conventional sensors, with temperature differences less than 1 °C (repeatability 0.1 °C), and humidity differences mostly within 5% of mixing ratio. Under transient conditions, we demonstrate how the instrument can be used to evaluate the response times of conventional sensors.