LALeeor Alon

Leeor Alon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Leeor Alon has a total of 42 co-authors. Here are the top co-authors by number of shared publications:

  • George Verghese

    Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States

    5 shared publications
  • Fatemeh Safari

    Center for Advanced Imaging Innovation and Research (CAI2R), New Yorsity School of Medicine, New York, USA

    3 shared publications
  • Omid Yaghmazadeh

    Assistant Professor, Department of Electrical and Computer Engineering, Boise State University, Boise, USA

    3 shared publications
  • Daniel K. Sodickson

    Center for Advanced Imaging Innovation and Research (CAI2R), New Yorsity School of Medicine, New York, USA

    2 shared publications
  • Jiangyang Zhang

    Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, USA

    2 shared publications
  • Kai Tobias Block

    Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States

    2 shared publications

Latest Publications

  • Open Access

    Software-defined Radar for MRI Motion Correction: A versatile, vendor-independent Platform

    by Christoph Maier, Eddy Solomon, George Verghese, Hersh Chandarana, Kai Tobias Block, Leeor Alon

    Purpose: To develop and evaluate a flexible, software-defined radar platform for contactless, vendor-independent motion detection and correction in MRI. Methods: A continuous-wave (CW) Doppler radar was implemented using a software-defined radio and the open-source GNU Radio framework. The system was deployed inside a 1.5T MRI scanner and synchronized with MRI acquisitions. We evaluated the performance in a custom-developed internal motion phantom and in healthy volunteers to track respiration and bulk motion. The radar-derived signal was validated against cine MRI and used to demonstrate both retrospective and prospective motion management techniques in phantom and in healthy volunteers. Results: The radar provided robust motion signals that correlated strongly with image-based ground truth signals in both phantom and volunteer experiments. Signal characteristics were found to be frequency-dependent, enabling optimization for different motion regimes. Retrospective correction of free-breathing abdominal data using the radar signal effectively suppressed respiratory artifacts, achieving image quality comparable to a self-gating approach. Prospective triggering successfully reduced motion artifacts in the phantom study. The system also reliably detected sporadic events such as swallowing during neck imaging. Conclusion: Software-defined radar was demonstrated to be an effective platform for both prospective and retrospective motion correction. Its independence from the MRI system, ultra-wide band capabilities, and body-region versatility enable the adaptation of the technique for a wide range of imaging applications and protocols.

  • Open Access

    MRI4ALL: A Week‐Long Hackathon for the Development of an Open‐Source Ultra‐Low‐Field MRI System

    by Kai Tobias Block, Chengtong Zhang, Vito Ciancia, Clarissa Cooley, Sairam Geethanath, Jason Stockmann, George Verghese, Leeor Alon

    The goal of the MRI4ALL hackathon, which took place in October 2023, was to develop a functional low‐field MRI scanner in just one week and to release all created source code and resources as open‐source packages. The event was attended by 52 participants from 16 institutions who assembled the scanner on the last day of the hackathon. The scanner's magnetic B0 field with a strength of 43 mT and a target field‐of‐view size of 11 cm3 was created with a Halbach array made from 990 N40UH permanent magnets, held in place using 3D printed ring formers. Gradient coils were fabricated by gluing enameled copper wire onto 3D printed holders with imprinted wire patterns. A solenoid coil for RF transmission and reception was built by winding 20 turns of Litz wire around a 3D printed cylinder. A Red Pitaya FPGA prototyping board running the MaRCoS framework was used to control the scanner components, and a GPA‐FHDO amplifier board was used to drive the gradients. To simplify the scanner's operation, console software with an intuitive graphical user interface was developed in Python using the PyPulseq package for sequence calculations. Furthermore, the scanner was equipped with a cooling system, as well as options for passive and active shimming. After resolving several technical issues that arose during the assembly, the scanner is now able to acquire MR images with different sequences. While not suitable for real‐world clinical applications, it can be utilized for educational purposes or as a low‐cost prototyping platform. Moreover, it may serve as a reference design for future MRI development projects. All source code and resources are available on the project website mri4all.org, allowing other groups to replicate the scanner.Evidence Level: n/aTechnical Efficacy: Stage 1.


  • Open Access

    An experimental system for detection and localization of hemorrhage using ultra-wideband microwaves with deep learning

    by Eisa Hedayati, Fatemeh Safari, George Verghese, Vito R. Ciancia, Daniel K. Sodickson, Seena Dehkharghani, Leeor Alon

    Stroke is a leading cause of mortality and disability. Emergent diagnosis and intervention are critical, and predicated upon initial brain imaging; however, existing clinical imaging modalities are generally costly, immobile, and demand highly specialized operation and interpretation. Low-energy microwaves have been explored as a low-cost, small form factor, fast, and safe probe for tissue dielectric properties measurements, with both imaging and diagnostic potential. Nevertheless, challenges inherent to microwave reconstruction have impeded progress, hence conduction of microwave imaging remains an elusive scientific aim. Herein, we introduce a dedicated experimental framework comprising a robotic navigation system to translate blood-mimicking phantoms within a human head model. An 8-element ultra-wideband array of modified antipodal Vivaldi antennas was developed and driven by a two-port vector network analyzer spanning 0.6–9.0 GHz at an operating power of 1 mW. Complex scattering parameters were measured, and dielectric signatures of hemorrhage were learned using a dedicated deep neural network for prediction of hemorrhage classes and localization. An overall sensitivity and specificity for detection >0.99 was observed, with Rayleigh mean localization error of 1.65 mm. The study establishes the feasibility of a robust experimental model and deep learning solution for ultra-wideband microwave stroke detection.


  • Open-source versatile 3D-print animal conditioning platform design for in vivo preclinical brain imaging in awake mice and anesthetized mice and rats

    by Zakia Ben Youss, Tanzil Mahmud Arefin, Sawwal Qayyum, Runjie Yi, Jiangyang Zhang, Youssef Zaim Wadghiri, Leeor Alon, Omid Yaghmazadeh

    Proper animal conditioning is a key factor in the quality and success of preclinical neuroimaging applications. Here, we introduce an open-source easy-to-modify multimodal 3D printable design for rodent conditioning for magnetic resonance imaging (MRI) or other imaging modalities. Our design can be used for brain imaging in anesthetized or awake mice, and in anesthetized rats. We show ease of use and reproducibility of subject conditioning with anatomical T2-weighted imaging for both mice and rats. We also demonstrate the application of our design for awake functional MRI in mice using both visual evoked potential and olfactory stimulation paradigms. In addition, using a combined MRI, positron emission tomography and X-ray computed tomography experiment, we demonstrate that our proposed cradle design can be utilized for multiple imaging modalities.


  • Autonomous animal heating and cooling system for temperature‐regulated magnetic resonance experiments

    by George Verghese, Mihaly Vöröslakos, Stefan Markovic, Assaf Tal, Seena Dehkharghani, Omid Yaghmazadeh, Leeor Alon

    Temperature is a hallmark parameter influencing almost all magnetic resonance properties (e.g., T1, T2, proton density, and diffusion). In the preclinical setting, temperature has a large influence on animal physiology (e.g., respiration rate, heart rate, metabolism, and oxidative stress) and needs to be carefully regulated, especially when the animal is under anesthesia and thermoregulation is disrupted. We present an open‐source heating and cooling system capable of regulating the temperature of the animal. The system was designed using Peltier modules capable of heating or cooling a circulating water bath with active temperature feedback. Feedback was obtained using a commercial thermistor, placed in the animal rectum, and a proportional‐integral‐derivative controller was used to modulate the temperature. Its operation was demonstrated in a phantom as well as in mouse and rat animal models, where the standard deviation of the temperature of the animal upon convergence was less than a 10th of a degree. An application where brain temperature of a mouse was modulated was demonstrated using an invasive optical probe and noninvasive magnetic resonance spectroscopic thermometry measurements.


  • Open Access

    An experimental system for detection and localization of hemorrhage using ultra-wideband microwaves with deep learning

    by Eisa Hedayati, Fatemeh Safari, George Verghese, Vito R. Ciancia, Daniel K. Sodickson, Seena Dehkharghani, Leeor Alon

    Stroke is a leading cause of mortality and disability. Emergent diagnosis and intervention are critical, and predicated upon initial brain imaging; however, existing clinical imaging modalities are generally costly, immobile, and demand highly specialized operation and interpretation. Low-energy microwaves have been explored as low-cost, small form factor, fast, and safe probes of tissue dielectric properties, with both imaging and diagnostic potential. Nevertheless, challenges inherent to microwave reconstruction have impeded progress, hence microwave imaging (MWI) remains an elusive scientific aim. Herein, we introduce a dedicated experimental framework comprising a robotic navigation system to translate blood-mimicking phantoms within an anatomically realistic human head model. An 8-element ultra-wideband (UWB) array of modified antipodal Vivaldi antennas was developed and driven by a two-port vector network analyzer spanning 0.6-9.0 GHz at an operating power of 1 mw. Complex scattering parameters were measured, and dielectric signatures of hemorrhage were learned using a dedicated deep neural network for prediction of hemorrhage classes and localization. An overall sensitivity and specificity for detection >0.99 was observed, with Rayliegh mean localization error of 1.65 mm. The study establishes the feasibility of a robust experimental model and deep learning solution for UWB microwave stroke detection.

  • Open Access

    In-vivo measurement of radio frequency electric fields in mice brain

    by Omid Yaghmazadeh, Seth Schoenhardt, Arya Sarabandi, Ali Sabet, Kazem Sabet, Fatemeh Safari, Leeor Alon, György Buzsáki


  • Open Access

    Open-source versatile 3D-print animal conditioning platform design for in-vivo preclinical brain imaging in awake mice and anesthetized mice and rats

    by Zakia Ben Youss Gironda, Tanzil Mahmud Arefin, Sawwal Qayyum, Jiangyang Zhang, Youssef Zaim Wadghiri, Leeor Alon, Omid Yaghmazadeh

    Proper animal conditioning is a key factor in the quality and success of preclinical neuroimaging applications. We introduce an open-source easy-to-modify multi-modal 3D printable design for rodent conditioning for magnetic resonance imaging (MRI) or other imaging modalities. Our design can be used for brain imaging in anesthetized or awake mice and anesthetized rats. We show ease-of-use and reproducibility of subject conditioning with anatomical T2-weighted imaging for both mice and rats. We also demonstrate application of our design for awake fMRI in mice using both visual evoked potential and olfactory stimulation paradigms. In addition, we demonstrate that our proposed cradle design can be extended to multiple imaging modalities combining MRI, Positron emission tomography and X-ray computed tomography.


  • Open Access

    Multinuclear absolute magnetic resonance thermometry

    by Emilia V. Silletta, Alexej Jerschow, Guillaume Madelin, Leeor Alon

    Non-invasive measurement of absolute temperature is important for proper characterization of various pathologies and for evaluation of thermal dose during interventional procedures. The proton (hydrogen nucleus) magnetic resonance (MR) frequency shift method can be used to map relative temperature changes. However, spatiotemporal variations in the main magnetic field and the lack of local internal frequency reference challenge the determination of absolute temperature. Here, we introduce a multinuclear method for absolute MR thermometry, based on the fact that the hydrogen and sodium nuclei exhibit a unique and distinct characteristic frequency dependence with temperature and with electrolyte concentration. A one-to-one mapping between the precession frequency difference of the two nuclei and absolute temperature is demonstrated. Proof-of-concept experiments were conducted in aqueous solutions with different NaCl concentrations, in agarose gel samples, and in freshly excised ex vivo mouse tissues. One-dimensional chemical shift imaging experiments also demonstrated excellent agreement with infrared measurements.


  • Prospects for Millimeter-Wave Compliance Measurement Technologies [Measurements Corner]

    by Leeor Alon, Sami Gabriel, Gene Young Cho, Ryan Brown, Cem Murat Deniz

    In recent years, there has been an increasing interest in millimeterwave (mm-wave) technologies operating at frequencies between 10 and 300 GHz. mm-wave communication provides higher transfer rates that will be employed in the next-generation wireless networks. However, mm-wave device exposure compliance assessment is challenging due to a reduced wavelength and an increased number of antennas. In this article, we discuss physical features of future mmwave communication networks and describe the requirements for proper exposure compliance assessment. Leading technologies that can be prospectively used for mm-wave exposure compliance are surveyed. Their pros and cons with respect to operating frequency, availability, sensitivity, and speed are discussed.