Robert J. Cooper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert J. Cooper has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Alison C. Jones
Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, United Kingdom
3 shared publicationsSophie Williams
Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
2 shared publications- Aiqin Liu
School of Biomedical Sciences, University of Leeds, Leeds LS2 9JT, UK
1 shared publication - Alison C. Jones
School of Mechanical Engineering, University of Leeds, Leeds, UK
1 shared publication Dawn Groves
Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
1 shared publication- Gavin A. Day
Institute of Medical and Biological Engineering, Mechanical Engineering, University of Leeds, UK
1 shared publication
Latest Publications
- Open Access
- 1 September 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 109, 103797
Development of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms
- 1 September 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 109, 103797
Open AccessDevelopment of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms
- Open Access
- 3 September 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 74 (1) , 1-12
Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges
The knee joint is a complex mechanical system, and computational modelling can provide vital information for the prediction of disease progression and of the potential for therapeutic interventions. This review provides an overview of the challenges involved in developing finite element models of the tibiofemoral joint, including the representation of appropriate geometry and material properties, loads and motions, and establishing pertinent outputs. The importance of validation for computational models in biomechanics has been highlighted by a number of papers, and finite element models of the tibiofemoral joint are a particular area in which validation can be challenging, due to the complex nature of the knee joint, its geometry and its constituent tissue properties. A variety of study designs have emerged to tackle these challenges, and these can be categorised into several different types. The role of validation, and the strategies adopted by these different study types, are discussed. Models representing trends and sensitivities often utilise generic representations of the knee and provide conclusions with relevance to general populations, usually without explicit validation. Models representing in vitro specimens or in vivo subjects can, to varying extents, be more explicitly validated, and their conclusions are more subject-specific. The potential for these approaches to examine the effects of patient variation is explored, which could lead to future applications in defining how treatments may be stratified for subgroups of patients.
- 3 September 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 74 (1) , 1-12
Open AccessFinite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges
The knee joint is a complex mechanical system, and computational modelling can provide vital information for the prediction of disease progression and of the potential for therapeutic interventions. This review provides an overview of the challenges involved in developing finite element models of the tibiofemoral joint, including the representation of appropriate geometry and material properties, loads and motions, and establishing pertinent outputs. The importance of validation for computational models in biomechanics has been highlighted by a number of papers, and finite element models of the tibiofemoral joint are a particular area in which validation can be challenging, due to the complex nature of the knee joint, its geometry and its constituent tissue properties. A variety of study designs have emerged to tackle these challenges, and these can be categorised into several different types. The role of validation, and the strategies adopted by these different study types, are discussed. Models representing trends and sensitivities often utilise generic representations of the knee and provide conclusions with relevance to general populations, usually without explicit validation. Models representing in vitro specimens or in vivo subjects can, to varying extents, be more explicitly validated, and their conclusions are more subject-specific. The potential for these approaches to examine the effects of patient variation is explored, which could lead to future applications in defining how treatments may be stratified for subgroups of patients.
- Open Access
- 1 May 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 54, 62-70
Patient-specific parameterised cam geometry in finite element models of femoroacetabular impingement of the hip
- 1 May 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 54, 62-70
Open AccessPatient-specific parameterised cam geometry in finite element models of femoroacetabular impingement of the hip
- Open Access
- 5 April 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 33 (11)
Three‐dimensional assessment of impingement risk in geometrically parameterised hips compared with clinical measures
Abnormal bony morphology is a factor implicated in hip joint soft tissue damage and an increased lifetime risk of osteoarthritis. Standard 2‐dimensional radiographic measurements for diagnosis of hip deformities, such as cam deformities on the femoral neck, do not capture the full joint geometry and are not indicative of symptomatic damage.In this study, a 3‐dimensional geometric parameterisation system was developed to capture key variations in the femur and acetabulum of subjects with clinically diagnosed cam deformity. The parameterisation was performed for computed tomography scans of 20 patients (10 female and 10 male). Novel quantitative measures of cam deformity were taken and used to assess differences in morphological deformities between males and females.The parametric surfaces matched the more detailed, segmented hip bone geometry with low fitting error. The quantitative severity measures captured both the size and the position of cams and distinguished between cam and control femurs. The precision of the measures was sufficient to identify differences between subjects that could not be seen with the sole use of 2‐dimensional imaging. In particular, cams were found to be more superiorly located in males than in females.As well as providing a means to distinguish between subjects more clearly, the new geometric hip parameterisation facilitates the flexible and rapid generation of a range of realistic hip geometries including cams. When combined with material property models, these stratified cam shapes can be used for further assessment of the effect of the geometric variation under impingement conditions.
- 5 April 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 33 (11)
Open AccessThree‐dimensional assessment of impingement risk in geometrically parameterised hips compared with clinical measures
Abnormal bony morphology is a factor implicated in hip joint soft tissue damage and an increased lifetime risk of osteoarthritis. Standard 2‐dimensional radiographic measurements for diagnosis of hip deformities, such as cam deformities on the femoral neck, do not capture the full joint geometry and are not indicative of symptomatic damage.In this study, a 3‐dimensional geometric parameterisation system was developed to capture key variations in the femur and acetabulum of subjects with clinically diagnosed cam deformity. The parameterisation was performed for computed tomography scans of 20 patients (10 female and 10 male). Novel quantitative measures of cam deformity were taken and used to assess differences in morphological deformities between males and females.The parametric surfaces matched the more detailed, segmented hip bone geometry with low fitting error. The quantitative severity measures captured both the size and the position of cams and distinguished between cam and control femurs. The precision of the measures was sufficient to identify differences between subjects that could not be seen with the sole use of 2‐dimensional imaging. In particular, cams were found to be more superiorly located in males than in females.As well as providing a means to distinguish between subjects more clearly, the new geometric hip parameterisation facilitates the flexible and rapid generation of a range of realistic hip geometries including cams. When combined with material property models, these stratified cam shapes can be used for further assessment of the effect of the geometric variation under impingement conditions.