Hideki Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hideki Tanaka has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Motomune Kodama
Research & Development Group, Hitachi Ltd, 7-1-1 Omika-cho, Hitachi-shi, Ibaraki, 319-1292, Japan
11 shared publications Hiroshi Kotaki
6 shared publicationsTakaaki Suzuki
6 shared publications- Akiyoshi Matsumoto
National Institute for Materials Science
4 shared publications - Gen Nishijima
National Institute for Materials Science
4 shared publications - Takaaki Suzuki
Hitachi Ltd., Research & Development Group, Hitachi-shi, Ibaraki-ken Japan
4 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Effects of coronene addition and roller die drawing on critical current density in superconducting MgB2 wires fabricated from mechanically milled powder
Mechanical milling of magnesium and boron powders generates metal-matrix composite particles, in which boron particles are distributed inside a magnesium matrix. In the case of superconducting MgB2 wires, this distinctive particle structure effectively reduces filament porosity and increases critical current density. However, the precursor particles are hard to handle because of their poor deformability. To fulfil their potential, the wires need to be prepared under suitable conditions. In this paper, the effectiveness of roller die drawing and moderate coronene addition is clarified. Unlike conventional drawing, roller die drawing causes the precursor particles to deform and adhere to each other owing to longitudinal compressive stress at neutral point. As is well known, carbon in coronene is substituted for boron in MgB2, strengthens carrier scattering, and improves critical current density at a high magnetic field. Moreover, the coronene addition has an extra effect on the mechanical milling process; that is, coronene particles are dispersed in the magnesium matrix during milling, soften the precursor particles, and prevent generation of visible voids and cracks in the filaments.
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffects of coronene addition and roller die drawing on critical current density in superconducting MgB2 wires fabricated from mechanically milled powder
Mechanical milling of magnesium and boron powders generates metal-matrix composite particles, in which boron particles are distributed inside a magnesium matrix. In the case of superconducting MgB2 wires, this distinctive particle structure effectively reduces filament porosity and increases critical current density. However, the precursor particles are hard to handle because of their poor deformability. To fulfil their potential, the wires need to be prepared under suitable conditions. In this paper, the effectiveness of roller die drawing and moderate coronene addition is clarified. Unlike conventional drawing, roller die drawing causes the precursor particles to deform and adhere to each other owing to longitudinal compressive stress at neutral point. As is well known, carbon in coronene is substituted for boron in MgB2, strengthens carrier scattering, and improves critical current density at a high magnetic field. Moreover, the coronene addition has an extra effect on the mechanical milling process; that is, coronene particles are dispersed in the magnesium matrix during milling, soften the precursor particles, and prevent generation of visible voids and cracks in the filaments.
- 17 December 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (1) , 015019
Examination of factors affecting strain tolerance of multifilament MgB2 wires with Fe barrier
There are two fabrication processes, the wind and react method and the react and wind method, that are used to manufacture magnesium diboride (MgB2) magnets. The react and wind method is more desirable to simplify the coil fabrication process, but the understanding of the strain tolerance of the sintered MgB2 wire is insufficient. Hence, this study focused on determining the main factors that contribute to the strain tolerance of the MgB2 wire with Fe barrier. It is generally thought that irreversible strain of sintered MgB2 wire is mainly determined from the residual strain of MgB2 filament, which is caused by the difference in the coefficient of thermal expansion among MgB2 and metal sheaths. To estimate the residual strain of MgB2 wire, the effect of yielded material must be considered. We calculated the residual strain of each constituent material used in the ten filament MgB2 wire in which copper was yielded during the cooling process from sintering temperature to room temperature. The calculated residual strains of metal sheaths except copper were compared with yield strains, and whether they yield was confirmed. The estimated residual strain of the MgB2 filament was also compared with the experimentally obtained irreversible strain, and the difference in these strains suggests the strain tolerance of the MgB2 filament. By measuring the irreversible strains of the MgB2 with different sintering times but the same residual strain, it was confirmed that the effect of the mechanical strength of the MgB2 filament on the strain tolerance of the MgB2 wire is slight but certain.
- 17 December 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (1) , 015019
Examination of factors affecting strain tolerance of multifilament MgB2 wires with Fe barrier
There are two fabrication processes, the wind and react method and the react and wind method, that are used to manufacture magnesium diboride (MgB2) magnets. The react and wind method is more desirable to simplify the coil fabrication process, but the understanding of the strain tolerance of the sintered MgB2 wire is insufficient. Hence, this study focused on determining the main factors that contribute to the strain tolerance of the MgB2 wire with Fe barrier. It is generally thought that irreversible strain of sintered MgB2 wire is mainly determined from the residual strain of MgB2 filament, which is caused by the difference in the coefficient of thermal expansion among MgB2 and metal sheaths. To estimate the residual strain of MgB2 wire, the effect of yielded material must be considered. We calculated the residual strain of each constituent material used in the ten filament MgB2 wire in which copper was yielded during the cooling process from sintering temperature to room temperature. The calculated residual strains of metal sheaths except copper were compared with yield strains, and whether they yield was confirmed. The estimated residual strain of the MgB2 filament was also compared with the experimentally obtained irreversible strain, and the difference in these strains suggests the strain tolerance of the MgB2 filament. By measuring the irreversible strains of the MgB2 with different sintering times but the same residual strain, it was confirmed that the effect of the mechanical strength of the MgB2 filament on the strain tolerance of the MgB2 wire is slight but certain.
- 17 August 2022
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (9) , 094007
Relation between constituent material fraction in multifilamentary MgB2 wires and requirements for MRI magnets
Magnetic resonance imaging (MRI) occupies the largest segment of the commercial applications of superconductivity. The NbTi wire is typically applied to MRI magnets and fulfils their strict requirements. On the other hand, the dramatically large energy margin in the MgB2 wire is attractive for liquid helium-saving MRI magnets. However, there are many types of cross-sections in the MgB2 wires. This makes it difficult to analyse the applicability of the MgB2 wires to the MRI magnets systematically. This paper focuses on the in situ MgB2 wires with an iron matrix and a Monel reinforced member. Multiple evaluations are conducted for several types of MgB2 wires, and their applicability to the MRI magnets is discussed. Because the critical current density of the superconducting filaments does not largely depend on the cross-section of the wires, the engineering critical current density (J e) is roughly proportional to the superconducting fraction (λ sc). The acceptable bending strain of the heat-treated wires increases with the Monel fraction and is in the range of 0.3%–0.65%, which is larger than the value required for coil winding of the MRI magnets. Two types of protection approaches of the magnet are considered. One is an active protection. This approach requires a large fraction of the copper stabilizer in the cross-section of the wire and relatively reduces λ sc and J e. The other is the avoidance of quenches over the product lifetime using quick ramp-down of the magnet for unfortunate events, such as cooling system failure and emergency rundown. This approach requires no copper stabilizer and increases λ sc and J e thus widens the acceptable operational temperature range. The cross-section of the MgB2 wire can be designed with a certain level of freedom depending on its functional requirements.
- 17 August 2022
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (9) , 094007
Relation between constituent material fraction in multifilamentary MgB2 wires and requirements for MRI magnets
Magnetic resonance imaging (MRI) occupies the largest segment of the commercial applications of superconductivity. The NbTi wire is typically applied to MRI magnets and fulfils their strict requirements. On the other hand, the dramatically large energy margin in the MgB2 wire is attractive for liquid helium-saving MRI magnets. However, there are many types of cross-sections in the MgB2 wires. This makes it difficult to analyse the applicability of the MgB2 wires to the MRI magnets systematically. This paper focuses on the in situ MgB2 wires with an iron matrix and a Monel reinforced member. Multiple evaluations are conducted for several types of MgB2 wires, and their applicability to the MRI magnets is discussed. Because the critical current density of the superconducting filaments does not largely depend on the cross-section of the wires, the engineering critical current density (J e) is roughly proportional to the superconducting fraction (λ sc). The acceptable bending strain of the heat-treated wires increases with the Monel fraction and is in the range of 0.3%–0.65%, which is larger than the value required for coil winding of the MRI magnets. Two types of protection approaches of the magnet are considered. One is an active protection. This approach requires a large fraction of the copper stabilizer in the cross-section of the wire and relatively reduces λ sc and J e. The other is the avoidance of quenches over the product lifetime using quick ramp-down of the magnet for unfortunate events, such as cooling system failure and emergency rundown. This approach requires no copper stabilizer and increases λ sc and J e thus widens the acceptable operational temperature range. The cross-section of the MgB2 wire can be designed with a certain level of freedom depending on its functional requirements.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Measurement of Irreversible External-Compressive Strain at RT and Enhancing Strain Tolerance at RT on MgB2 Multifilament Wire
The strain tolerance of magnesium dioboride (MgB 2 ) wire should be enhanced at room temperature for fabricating MgB 2 coils by using the react and wind method. The irreversible external-compressive strain of MgB 2 filaments was measured by evaluating the critical current degradation of bent sample wires. From the results, MgB 2 filaments can accept -1.77% strain, and the pre-compressive strain should be -0.88% at room temperature to minimize its reversible bending radius. A stainless-steel reinforced 18-filament MgB 2 wire was fabricated and its strain tolerance was evaluated through bending and tensile tests at room temperature. The irreversible strain of this wire is 0.60%, and this wire seems to be suitable for the react and wind method. The filling factor of MgB 2 of this wire is 17%, so this wire has both suitable strain tolerance for the react and wind method and higher engineering current density.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Measurement of Irreversible External-Compressive Strain at RT and Enhancing Strain Tolerance at RT on MgB2 Multifilament Wire
The strain tolerance of magnesium dioboride (MgB 2 ) wire should be enhanced at room temperature for fabricating MgB 2 coils by using the react and wind method. The irreversible external-compressive strain of MgB 2 filaments was measured by evaluating the critical current degradation of bent sample wires. From the results, MgB 2 filaments can accept -1.77% strain, and the pre-compressive strain should be -0.88% at room temperature to minimize its reversible bending radius. A stainless-steel reinforced 18-filament MgB 2 wire was fabricated and its strain tolerance was evaluated through bending and tensile tests at room temperature. The irreversible strain of this wire is 0.60%, and this wire seems to be suitable for the react and wind method. The filling factor of MgB 2 of this wire is 17%, so this wire has both suitable strain tolerance for the react and wind method and higher engineering current density.
- 7 June 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (7) , 074003
Feasibility study of novel rapid ramp-down procedure in MgB 2 MRI magnet using persistent current switch with high off-resistivity
Dry magnets using high temperature superconductors and MgB 2 are attractive options to depart from dependence on liquid helium in MRI scanners. In the dry magnets, however, lack of thermal mass of cryogen makes a controlled quench difficult and extends time for restarting the magnets after the quench. In this study, a novel rapid ramp-down procedure, which can be substituted for the controlled quench in emergency rundown, is proposed, and its feasibility is proven for a 1.5 T whole-body MgB 2 MRI magnet. In this procedure, a power supply receives current from a persistent current switch (PCS), the PCS is turned off by heating, the power supply is interrupted by a breaker, and the stored energy in the magnet is mostly consumed at an external resistor. Owing to the large energy margin of MgB 2 wires, the AC loss during the ramp-down does not bring a quench of the MgB 2 coils. A niobium–titanium sheathed MgB 2 wire 0.60 mm in diameter is made, and a PCS with high off-resistivity is designed using this wire. The shunt current during the ramp-down does not bring the burnout of the PCS when the wire length is sufficiently long, typically hundreds of metres. Because heat generation inside the cryostat during the ramp-down is a few per cent of the stored energy in the magnet, the magnet is not heated excessively. As a result, the proposed ramp-down procedure should shorten the downtime of MRI scanners.
- 7 June 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (7) , 074003
Feasibility study of novel rapid ramp-down procedure in MgB 2 MRI magnet using persistent current switch with high off-resistivity
Dry magnets using high temperature superconductors and MgB 2 are attractive options to depart from dependence on liquid helium in MRI scanners. In the dry magnets, however, lack of thermal mass of cryogen makes a controlled quench difficult and extends time for restarting the magnets after the quench. In this study, a novel rapid ramp-down procedure, which can be substituted for the controlled quench in emergency rundown, is proposed, and its feasibility is proven for a 1.5 T whole-body MgB 2 MRI magnet. In this procedure, a power supply receives current from a persistent current switch (PCS), the PCS is turned off by heating, the power supply is interrupted by a breaker, and the stored energy in the magnet is mostly consumed at an external resistor. Owing to the large energy margin of MgB 2 wires, the AC loss during the ramp-down does not bring a quench of the MgB 2 coils. A niobium–titanium sheathed MgB 2 wire 0.60 mm in diameter is made, and a PCS with high off-resistivity is designed using this wire. The shunt current during the ramp-down does not bring the burnout of the PCS when the wire length is sufficiently long, typically hundreds of metres. Because heat generation inside the cryostat during the ramp-down is a few per cent of the stored energy in the magnet, the magnet is not heated excessively. As a result, the proposed ramp-down procedure should shorten the downtime of MRI scanners.
- 8 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
An MgB2 Superconducting Joint With Its Own Heat-Treatment Schedule
We suggested an MgB 2 joint process with its own heat-treatment schedule to apply it for our 1.5-T MgB 2 “finger” MRI magnet. In fabricating the MgB 2 magnet, the optimal heat-treatment schedule to attain a reproducible and high critical current is different in a joint and a coil. To solve this problem, we introduced an additional heating system, which is composed of a cartridge heater and a thermocouple connected with a copper block, into a box-type furnace. Then, we carried out heat-treatments with exclusively increasing the joint-part temperature above the Mg melting point of 645 °C —the joint was actually heated up to 700 °C . We evaluated a critical current and a crystal structure of the obtained MgB 2 joint. From experimental results, we found that the joint heated with the own heat-treatment schedule, which is 700 °C for 1 h + 600°C for 11 h, showed a good I c of over 450 A at 15K under self-field. The joint resistance was estimated by the coil operation for 18 days, and it was expected to be less than 10 −12 Ω.
- 8 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
An MgB2 Superconducting Joint With Its Own Heat-Treatment Schedule
We suggested an MgB 2 joint process with its own heat-treatment schedule to apply it for our 1.5-T MgB 2 “finger” MRI magnet. In fabricating the MgB 2 magnet, the optimal heat-treatment schedule to attain a reproducible and high critical current is different in a joint and a coil. To solve this problem, we introduced an additional heating system, which is composed of a cartridge heater and a thermocouple connected with a copper block, into a box-type furnace. Then, we carried out heat-treatments with exclusively increasing the joint-part temperature above the Mg melting point of 645 °C —the joint was actually heated up to 700 °C . We evaluated a critical current and a crystal structure of the obtained MgB 2 joint. From experimental results, we found that the joint heated with the own heat-treatment schedule, which is 700 °C for 1 h + 600°C for 11 h, showed a good I c of over 450 A at 15K under self-field. The joint resistance was estimated by the coil operation for 18 days, and it was expected to be less than 10 −12 Ω.
- 14 January 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (2) , 025018
Critical current density defined at low electric field criterion and energy margin of superconducting MgB 2 wires in wide temperature and magnetic field range
High-temperature superconductors (HTS) and MgB 2 may potentially improve the usability of superconducting magnets dramatically owing to their large energy margin. When HTS and MgB 2 wires are used for magnets operated in the persistent current mode, such as in magnetic resonance imaging (MRI) scanners, the electric field generated in the wires must be lower than 10 −10 V m −1 . In this paper, critical current density, J c , defined at an electric field criterion of 10 −10 V m −1 is evaluated from a magnetisation decay measurement for state-of-the-art monofilamentary MgB 2 wires. By using the obtained J c , a critical line of our multifilamentary MgB 2 wire is shown on the temperature-magnetic field plane. Here, the critical line is defined as a line on which an electric field of 10 −10 V m −1 is generated at a coil current density of 150 A mm −2 . The area inside the critical line is demonstrated to be large enough to fulfil the requirement of 1.5 T MRI scanners operated at 10K–15K. In addition, the iso energy-margin lines are shown on the temperature-magnetic field plane and compared with those of NbTi wires. The MgB 2 wire has an order of magnitude greater energy margin than the NbTi wires in most of the area inside the critical line. This suggests that the MgB 2 wire is highly unlikely to be quenched due to mechanical disturbances.
- 14 January 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (2) , 025018
Critical current density defined at low electric field criterion and energy margin of superconducting MgB 2 wires in wide temperature and magnetic field range
High-temperature superconductors (HTS) and MgB 2 may potentially improve the usability of superconducting magnets dramatically owing to their large energy margin. When HTS and MgB 2 wires are used for magnets operated in the persistent current mode, such as in magnetic resonance imaging (MRI) scanners, the electric field generated in the wires must be lower than 10 −10 V m −1 . In this paper, critical current density, J c , defined at an electric field criterion of 10 −10 V m −1 is evaluated from a magnetisation decay measurement for state-of-the-art monofilamentary MgB 2 wires. By using the obtained J c , a critical line of our multifilamentary MgB 2 wire is shown on the temperature-magnetic field plane. Here, the critical line is defined as a line on which an electric field of 10 −10 V m −1 is generated at a coil current density of 150 A mm −2 . The area inside the critical line is demonstrated to be large enough to fulfil the requirement of 1.5 T MRI scanners operated at 10K–15K. In addition, the iso energy-margin lines are shown on the temperature-magnetic field plane and compared with those of NbTi wires. The MgB 2 wire has an order of magnitude greater energy margin than the NbTi wires in most of the area inside the critical line. This suggests that the MgB 2 wire is highly unlikely to be quenched due to mechanical disturbances.
- 18 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Design of a Magnet and Gradient Coils for a Tabletop Liquid-Helium-Free, Persistent-Mode 1.5-T MgB$_2$ Osteoporosis MRI
We have finalized the design of a full-scale tabletop 1.5-T/90-mm MgB 2 finger MRI magnet system for osteoporosis screening based on our preliminary test results of small coils and superconducting joints. The magnet will operate in persistent mode at 10 K with an additional 5 K temperature margin. The magnet design which includes six main coils and an iron shield satisfies the required specification of a field intensity of 1.5 T, homogeneity of ≤5 ppm over a 20-mm diameter of spherical volume, and a fringe field of ≤5 gauss at 0.5 m in radius from the magnet center. An active protection method using external heaters will be applied to prevent a local hot spot in the MgB 2 windings from being overheated when quench occurs. Active shield transverse and axial gradient coils for this tabletop osteoporosis MRI, having primary and shield coil pairs, are designed to minimize stray fields that can induce eddy currents on nearby metal surface and thus imaging artifacts. This paper covers design and analysis of: 1) the main coils and iron shield; 2) coil former; 3) quench protection; and 4) active shield gradient coils. We also discuss design changes of the cryostat and equipment plan for the overall system. The magnet system will be completed and then, equipped with other MRI hardware components including an in-house-made gradient coil assembly and RF coils for demonstration of 1.5-T finger MRI in 2020.
- 18 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Design of a Magnet and Gradient Coils for a Tabletop Liquid-Helium-Free, Persistent-Mode 1.5-T MgB$_2$ Osteoporosis MRI
We have finalized the design of a full-scale tabletop 1.5-T/90-mm MgB 2 finger MRI magnet system for osteoporosis screening based on our preliminary test results of small coils and superconducting joints. The magnet will operate in persistent mode at 10 K with an additional 5 K temperature margin. The magnet design which includes six main coils and an iron shield satisfies the required specification of a field intensity of 1.5 T, homogeneity of ≤5 ppm over a 20-mm diameter of spherical volume, and a fringe field of ≤5 gauss at 0.5 m in radius from the magnet center. An active protection method using external heaters will be applied to prevent a local hot spot in the MgB 2 windings from being overheated when quench occurs. Active shield transverse and axial gradient coils for this tabletop osteoporosis MRI, having primary and shield coil pairs, are designed to minimize stray fields that can induce eddy currents on nearby metal surface and thus imaging artifacts. This paper covers design and analysis of: 1) the main coils and iron shield; 2) coil former; 3) quench protection; and 4) active shield gradient coils. We also discuss design changes of the cryostat and equipment plan for the overall system. The magnet system will be completed and then, equipped with other MRI hardware components including an in-house-made gradient coil assembly and RF coils for demonstration of 1.5-T finger MRI in 2020.