Mohammed Qintar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammed Qintar has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Hussam Al Hennawi
Department of Internal Medicine, Jefferson Abington Hospital, Abington, Pennsylvania, USA
6 shared publications John A. Spertus
Saint Luke's Mid America Heart Institute and the University of Missouri-Kansas City, Kansas City, Missouri
6 shared publicationsShaurya Srivastava
Department of Cardiology, Michigan State University/University of Michigan Health Sparrow Hospital, Lansing, Michigan, USA
6 shared publicationsPedro Villablanca
Division of Cardiology, Center for Structural Heart Disease Henry Ford Health System Detroit Michigan USA
5 shared publicationsSuzanne V. Arnold
Saint Luke's Mid America Heart Institute and the University of Missouri-Kansas City, Kansas City, Missouri
5 shared publicationsAhmad Abulshamat
Division of Cardiology, Jordan University Hospital, Amman, Jordan
4 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Global Cardiology Science and Practice in Global Cardiology Science and Practice
- Vol. 2026 (4)
Fully biodegradable versus nitinol occluder devices for transcatheter patent foramen ovale closure: A systematic review
Background: The optimal device platform for transcatheter patent foramen ovale (PFO) closure remains uncertain. Permanent nitinol occluders are widely used, but concerns persist regarding long-term foreign-body exposure and device-related complications. Fully biodegradable occluders have been developed to provide temporary septal support during endothelialization before gradual resorption, with the intended benefit accruing only after the device has resorbed. Methods: We systematically searched Medline, PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and trial registries through 17 February 2026. Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using RoB 2 for randomized evidence and ROBINS-I for non-randomized evidence. Because of clinical and methodological heterogeneity, findings were synthesized narratively. Results: Three comparative studies were included — one randomized trial and two retrospective cohorts — comprising 481 analyzed participants. Procedural success was high with both device types. Residual shunt generally decreased over time, with no clear advantage for either platform. Serious adverse events, device thrombosis, embolization or detachment, and atrial arrhythmias were uncommon, though event counts were small. Two of the three studies were migraine-specific cohorts, and the randomized trial enrolled a mixed-indication population in which treatment-resistant migraine was the most common single indication; the available evidence therefore reflects device-platform performance predominantly in migraine populations. No study followed participants substantially beyond the expected biodegradation window. Conclusion: Current evidence suggests similar short- to mid-term performance of biodegradable and nitinol occluders, but certainty is low to very low, and no study yet assesses the post-resorption period in which any advantage of a biodegradable platform would be expected to emerge. Larger multicenter studies with standardized imaging, rhythm monitoring, and follow-up extending beyond biodegradation are needed. Because two of the three studies were migraine-specific and event counts were small, these findings should not be extrapolated to stroke-prevention populations, and the absence of observed between-device differences should not be interpreted as equivalence.
- 31 August 2026
- Published by Global Cardiology Science and Practice in Global Cardiology Science and Practice
- Vol. 2026 (4)
Open AccessFully biodegradable versus nitinol occluder devices for transcatheter patent foramen ovale closure: A systematic review
Background: The optimal device platform for transcatheter patent foramen ovale (PFO) closure remains uncertain. Permanent nitinol occluders are widely used, but concerns persist regarding long-term foreign-body exposure and device-related complications. Fully biodegradable occluders have been developed to provide temporary septal support during endothelialization before gradual resorption, with the intended benefit accruing only after the device has resorbed. Methods: We systematically searched Medline, PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and trial registries through 17 February 2026. Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using RoB 2 for randomized evidence and ROBINS-I for non-randomized evidence. Because of clinical and methodological heterogeneity, findings were synthesized narratively. Results: Three comparative studies were included — one randomized trial and two retrospective cohorts — comprising 481 analyzed participants. Procedural success was high with both device types. Residual shunt generally decreased over time, with no clear advantage for either platform. Serious adverse events, device thrombosis, embolization or detachment, and atrial arrhythmias were uncommon, though event counts were small. Two of the three studies were migraine-specific cohorts, and the randomized trial enrolled a mixed-indication population in which treatment-resistant migraine was the most common single indication; the available evidence therefore reflects device-platform performance predominantly in migraine populations. No study followed participants substantially beyond the expected biodegradation window. Conclusion: Current evidence suggests similar short- to mid-term performance of biodegradable and nitinol occluders, but certainty is low to very low, and no study yet assesses the post-resorption period in which any advantage of a biodegradable platform would be expected to emerge. Larger multicenter studies with standardized imaging, rhythm monitoring, and follow-up extending beyond biodegradation are needed. Because two of the three studies were migraine-specific and event counts were small, these findings should not be extrapolated to stroke-prevention populations, and the absence of observed between-device differences should not be interpreted as equivalence.
- Open Access
- 3 July 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (17) , 103792
A uniQue wAy of Transcatheter mAss extraction
- 3 July 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (17) , 103792
Open AccessA uniQue wAy of Transcatheter mAss extraction
- Open Access
- 27 March 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (6) , 103421
Transcatheter Repair of Mitral Valve Leaflet Perforation Using Occluder Plug
- 27 March 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (6) , 103421
Open AccessTranscatheter Repair of Mitral Valve Leaflet Perforation Using Occluder Plug
- Open Access
- 18 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (24) , 102865
Aspiration of Left Atrial Masses Using the Large-Bore Manual Aspiration System
- 18 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (24) , 102865
Open AccessAspiration of Left Atrial Masses Using the Large-Bore Manual Aspiration System
- Open Access
- 4 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (1) , 102721
The DIMASHQ Procedure
- 4 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (1) , 102721
Open AccessThe DIMASHQ Procedure
- Open Access
- 6 November 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (21) , 102652
Successful Transcatheter Mitral Valve Mass Extraction With Complete Resolution of the Severe Mitral Regurgitation
- 6 November 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (21) , 102652
Open AccessSuccessful Transcatheter Mitral Valve Mass Extraction With Complete Resolution of the Severe Mitral Regurgitation
- Open Access
- 6 September 2024
- Published by Elsevier in Structural Heart
- Vol. 9 (3) , 100355
Transcatheter Closure of Complex Multifenestrated Atrial Septal Defect Using Three Septal Occluders: Is Three Too Many?
- 6 September 2024
- Published by Elsevier in Structural Heart
- Vol. 9 (3) , 100355
Open AccessTranscatheter Closure of Complex Multifenestrated Atrial Septal Defect Using Three Septal Occluders: Is Three Too Many?
- Open Access
- 7 August 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (15) , 102448
The MICHIGAN Procedure
- 7 August 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (15) , 102448
Open AccessThe MICHIGAN Procedure
- Open Access
- 3 June 2024
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 20 (1) , 40-44
Combining Novel Thrombectomy Devices for Intracardiac Mass Extraction: The Kong and Godzilla of Mass Extraction
Transcatheter extraction of an intracardiac mass is a newer approach that may lead to nonsurgical treatment of complex cardiac masses. We present a case in which thrombectomy devices were combined to extract a right atrial mass, which highlights new frontiers in the treatment of complex transcatheter mass extraction. The combined use of two transcatheter thrombectomy devices (Kong and Godzilla) may provide a powerful addition to the existing armamentarium.
- 3 June 2024
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 20 (1) , 40-44
Open AccessCombining Novel Thrombectomy Devices for Intracardiac Mass Extraction: The Kong and Godzilla of Mass Extraction
Transcatheter extraction of an intracardiac mass is a newer approach that may lead to nonsurgical treatment of complex cardiac masses. We present a case in which thrombectomy devices were combined to extract a right atrial mass, which highlights new frontiers in the treatment of complex transcatheter mass extraction. The combined use of two transcatheter thrombectomy devices (Kong and Godzilla) may provide a powerful addition to the existing armamentarium.
- 15 June 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 200, 171-177
Management of Atrial Fibrillation Post Transcatheter Aortic Valve Implantation
- 15 June 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 200, 171-177
Management of Atrial Fibrillation Post Transcatheter Aortic Valve Implantation