Bijan Hashemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bijan Hashemi has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Mohsen Bakhshandeh
Department of Radiology Technology, Allied Medical Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran
10 shared publications - Seied Rabi Mahdavi
Iran University of Medical Sciences
6 shared publications - Amin Banaei
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
5 shared publications Bahram Mofid
Shahid Beheshti University of Medical Sciences
5 shared publicationsAzim Arbabi
Department of Radiotherapy, Imam Hossein (A.S.) Hospital, Shahid Beheshti University of Medical Science, Tehran, Iran
4 shared publicationsAmin Banaei
Department ofMedical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
3 shared publications
Latest Publications
- 2 June 2026
- Published by Elsevier in Physica Medica
- Vol. 147, 105827
Advancing radiotherapy with deep Learning: A review of dose prediction models
- 2 June 2026
- Published by Elsevier in Physica Medica
- Vol. 147, 105827
Advancing radiotherapy with deep Learning: A review of dose prediction models
- Open Access
- 1 January 2025
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 23  (1) , 239-244
Predicting prostate cancer radiotherapy complications: An integrated approach using radiomics, dosiomics, and machine learning
Background: We aimed to develop a robust prognostic model for assessing the risk of complications associated with radiotherapy in prostate cancer patients using radiomics and dosiomics feature and machine learning. Materials and Methods: A cohort of 60 patients undergoing pelvic radiation therapy was analyzed. The patients’ radiomics and dosiomics features were extracted ...
- 1 January 2025
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 23  (1) , 239-244
Open AccessPredicting prostate cancer radiotherapy complications: An integrated approach using radiomics, dosiomics, and machine learning
Background: We aimed to develop a robust prognostic model for assessing the risk of complications associated with radiotherapy in prostate cancer patients using radiomics and dosiomics feature and machine learning. Materials and Methods: A cohort of 60 patients undergoing pelvic radiation therapy was analyzed. The patients’ radiomics and dosiomics features were extracted ...
- Open Access
- 1 January 2023
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 19  (2) , 447-451
Effect of 13.56 MHz radiofrequency hyperthermia on mitotic cell cycle arrest in MCF7 breast cancer cell line and suggest a time interval for radiotherapy
Introduction: After surgery, radiotherapy is the most common technique to treat breast cancer. Over the past decades, the thermal effects of radiofrequency-wave hyperthermia combined with radiotherapy have been used to increase radiosensitivity in cancer treatment. The cells have various radiation and thermal sensitivities at different stages of the mitotic cycle. Furthermore, ionizing radiation and the thermal effect of hyperthermia affect the cells’ mitotic cycle and can partly induce cell cycle arrest. However, the time interval between hyperthermia and radiotherapy, as an essential factor influencing hyperthermia effect on cancer cells’ cycle arrest, has not been studied before. In this study, we investigated the effect of hyperthermia on the MCF7 cancer cell cycle arrest in mitotic cycles at various selected time intervals after hyperthermia to find and propose appropriate time intervals between hyperthermia and radiotherapy. Method and Materials: In this experimental study, we used the MCF7 breast cancer cell line to investigate the effect of 13.56 MHz hyperthermia (at a temperature of 43°C for a period of 20 min) on their cell cycle arrest. We performed the flowcytometry assay to assess the changes in the mitotic phases of the cell population at different time intervals (1, 6, 24, and 48 h) after hyperthermia. Results: Our flowcytometry results indicated the 24-h time interval has the most significant effect on the cell population at S and G2/M phases. Therefore, the 24-h time interval can be proposed as the most appropriate time after hyperthermia for carrying out combinational radiotherapy procedure. Conclusion: Among various investigated time intervals examined in our research, the 24-h time interval can be proposed as the most appropriate time between hyperthermia and radiotherapy for combinational therapy of breast cancer cells.
- 1 January 2023
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 19  (2) , 447-451
Open AccessEffect of 13.56 MHz radiofrequency hyperthermia on mitotic cell cycle arrest in MCF7 breast cancer cell line and suggest a time interval for radiotherapy
Introduction: After surgery, radiotherapy is the most common technique to treat breast cancer. Over the past decades, the thermal effects of radiofrequency-wave hyperthermia combined with radiotherapy have been used to increase radiosensitivity in cancer treatment. The cells have various radiation and thermal sensitivities at different stages of the mitotic cycle. Furthermore, ionizing radiation and the thermal effect of hyperthermia affect the cells’ mitotic cycle and can partly induce cell cycle arrest. However, the time interval between hyperthermia and radiotherapy, as an essential factor influencing hyperthermia effect on cancer cells’ cycle arrest, has not been studied before. In this study, we investigated the effect of hyperthermia on the MCF7 cancer cell cycle arrest in mitotic cycles at various selected time intervals after hyperthermia to find and propose appropriate time intervals between hyperthermia and radiotherapy. Method and Materials: In this experimental study, we used the MCF7 breast cancer cell line to investigate the effect of 13.56 MHz hyperthermia (at a temperature of 43°C for a period of 20 min) on their cell cycle arrest. We performed the flowcytometry assay to assess the changes in the mitotic phases of the cell population at different time intervals (1, 6, 24, and 48 h) after hyperthermia. Results: Our flowcytometry results indicated the 24-h time interval has the most significant effect on the cell population at S and G2/M phases. Therefore, the 24-h time interval can be proposed as the most appropriate time after hyperthermia for carrying out combinational radiotherapy procedure. Conclusion: Among various investigated time intervals examined in our research, the 24-h time interval can be proposed as the most appropriate time between hyperthermia and radiotherapy for combinational therapy of breast cancer cells.
- Open Access
- 1 January 2023
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 19  (Suppl 1) , S67-S73
Radiosensitization effect of radiofrequency hyperthermia in the presence of PEGylated-gold nanoparticles on the MCF-7 breast cancer cells under 6 MeV electron irradiation
Purpose: The purpose of the study was to investigate the radiosensitization effect of radiofrequency (RF) hyperthermia in combination with PEGylated gold nanoparticles (PEG-GNPs) on MCF-7 breast cancer cells under electron beam radiotherapy (EBRT) based on the clonogenic assay. Materials and Methods: The cell death of MCF-7 breast cancer cells treated with 13.56 MHz capacitive RF hyperthermia (power: 150W) for 2, 5, 10, and 15 min combined with 6 MeV EBRT, with a dose of 2 Gy, was evaluated in the presence of 20 nm PEG-GNPs with a low nontoxic concentration (20 mg/l). All the treatment groups were incubated for 14 days. Thereafter, survival fractions and viability of the cells were calculated and analyzed against the control group. Results: The presence of PEG-GNPs inside the MCF-7 cancer cells during electron irradiation decreased cell survival significantly (16.7%) compared to irradiated cells without GNPs. Applying hyperthermia before electron irradiation with a capacitive RF system decreased cell survival by about 53.7%, while hyperthermia without irradiation did not show any significant effect on cell survival. Combining the hyperthermia with the presence of PEG-GNPs in the cells decreased the cell survival by about 67% at the electron irradiation, showing their additive radiosensitization effect. Conclusion: Low nontoxic concentration of 20 nm PEG-GNPs increases the radiosensitization effect of combining 6 MeV EBRT and RF hyperthermia on MCF-7 cancer cells. Combining hyperthermia with PEG-GNPs in electron radiotherapy could be an appropriate method for enhancing radiotherapy effectiveness on cancerous cells which can be studied on different cells and electron energies in future research.
- 1 January 2023
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 19  (Suppl 1) , S67-S73
Open AccessRadiosensitization effect of radiofrequency hyperthermia in the presence of PEGylated-gold nanoparticles on the MCF-7 breast cancer cells under 6 MeV electron irradiation
Purpose: The purpose of the study was to investigate the radiosensitization effect of radiofrequency (RF) hyperthermia in combination with PEGylated gold nanoparticles (PEG-GNPs) on MCF-7 breast cancer cells under electron beam radiotherapy (EBRT) based on the clonogenic assay. Materials and Methods: The cell death of MCF-7 breast cancer cells treated with 13.56 MHz capacitive RF hyperthermia (power: 150W) for 2, 5, 10, and 15 min combined with 6 MeV EBRT, with a dose of 2 Gy, was evaluated in the presence of 20 nm PEG-GNPs with a low nontoxic concentration (20 mg/l). All the treatment groups were incubated for 14 days. Thereafter, survival fractions and viability of the cells were calculated and analyzed against the control group. Results: The presence of PEG-GNPs inside the MCF-7 cancer cells during electron irradiation decreased cell survival significantly (16.7%) compared to irradiated cells without GNPs. Applying hyperthermia before electron irradiation with a capacitive RF system decreased cell survival by about 53.7%, while hyperthermia without irradiation did not show any significant effect on cell survival. Combining the hyperthermia with the presence of PEG-GNPs in the cells decreased the cell survival by about 67% at the electron irradiation, showing their additive radiosensitization effect. Conclusion: Low nontoxic concentration of 20 nm PEG-GNPs increases the radiosensitization effect of combining 6 MeV EBRT and RF hyperthermia on MCF-7 cancer cells. Combining hyperthermia with PEG-GNPs in electron radiotherapy could be an appropriate method for enhancing radiotherapy effectiveness on cancerous cells which can be studied on different cells and electron energies in future research.
- Open Access
- 23 November 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17  (1) , 1-10
Introducing new plan evaluation indices for prostate dose painting IMRT plans based on apparent diffusion coefficient images
Dose painting planning would be more complicated due to different levels of prescribed doses and more complex evaluation with conventional plan quality indices considering uniform dose prescription. Therefore, we tried to introduce new indices for evaluating the dose distribution conformity and homogeneity of treatment volumes based on the tumoral cell density and relative volumes of each lesion in prostate IMRT. CT and MRI scans of 20 male patients having local prostate cancer were used for IMRT DP planning. Apparent diffusion coefficient (ADC) images were imported to a MATLAB program to identify lesion regions based on ADC values automatically. Regions with ADC values lower than 750 mm2/s and regions with ADC values higher than 750 and less than 1500 mm2/s were considered CTV70Gy (clinical tumor volume with 70 Gy prescribed dose), and CTV60Gy, respectively. Other regions of the prostate were considered as CTV53Gy. New plan evaluation indices based on evaluating the homogeneity (IOE(H)), and conformity (IOE(C)) were introduced, considering the relative volume of each lesion and cellular density obtained from ADC images. These indices were compared with conventional homogeneity and conformity indices and IOEs without considering cellular density. Furthermore, tumor control probability (TCP) was calculated for each patient, and the relationship of the assessed indices were evaluated with TCP values. IOE (H) and IOE (C) with considering cellular density had significantly lower values compared to conventional indices and IOEs without considering cellular density. (P < 0.05). TCP values had a stronger relationship with IOE(H) considering cell density (R2 = -0.415), and IOE(C) without considering cell density (R2 = 0.624). IOE plan evaluation indices proposed in this study can be used for evaluating prostate IMRT dose painting plans. We suggested to consider cell densities in the IOE(H) calculation formula and it’s appropriate to calculate IOE(C) without considering cell density values.
- 23 November 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17  (1) , 1-10
Open AccessIntroducing new plan evaluation indices for prostate dose painting IMRT plans based on apparent diffusion coefficient images
Dose painting planning would be more complicated due to different levels of prescribed doses and more complex evaluation with conventional plan quality indices considering uniform dose prescription. Therefore, we tried to introduce new indices for evaluating the dose distribution conformity and homogeneity of treatment volumes based on the tumoral cell density and relative volumes of each lesion in prostate IMRT. CT and MRI scans of 20 male patients having local prostate cancer were used for IMRT DP planning. Apparent diffusion coefficient (ADC) images were imported to a MATLAB program to identify lesion regions based on ADC values automatically. Regions with ADC values lower than 750 mm2/s and regions with ADC values higher than 750 and less than 1500 mm2/s were considered CTV70Gy (clinical tumor volume with 70 Gy prescribed dose), and CTV60Gy, respectively. Other regions of the prostate were considered as CTV53Gy. New plan evaluation indices based on evaluating the homogeneity (IOE(H)), and conformity (IOE(C)) were introduced, considering the relative volume of each lesion and cellular density obtained from ADC images. These indices were compared with conventional homogeneity and conformity indices and IOEs without considering cellular density. Furthermore, tumor control probability (TCP) was calculated for each patient, and the relationship of the assessed indices were evaluated with TCP values. IOE (H) and IOE (C) with considering cellular density had significantly lower values compared to conventional indices and IOEs without considering cellular density. (P < 0.05). TCP values had a stronger relationship with IOE(H) considering cell density (R2 = -0.415), and IOE(C) without considering cell density (R2 = 0.624). IOE plan evaluation indices proposed in this study can be used for evaluating prostate IMRT dose painting plans. We suggested to consider cell densities in the IOE(H) calculation formula and it’s appropriate to calculate IOE(C) without considering cell density values.
- Open Access
- 4 August 2022
- Published by Springer Nature in Research Square
Introducing new plan evaluation indices for prostate dose painting IMRT plans based on apparent diffusion coefficient images
Background: Dose painting planning would be more complicated due to different levels of prescribed doses and more complex evaluation with conventional plan quality indices considering uniform dose prescription. Therefore, we tried to introduce new indices for evaluating the dose distribution conformity and homogeneity of treatment volumes based on the tumoral cell density and relative volumes of each lesion in prostate IMRT. Methods: CT and MRI scans of 20 male patients having local prostate cancer were used for IMRT DP planning. Apparent diffusion coefficient (ADC) images were imported to a MATLAB program to identify lesion regions based on ADC values automatically. Regions with ADC values lower than 750 mm2/s and regions with ADC values higher than 750 and less than 1500 mm2/s were considered CTV70Gy (clinical tumor volume with 70Gy prescribed dose), and CTV60Gy, respectively. Other regions of the prostate were considered as CTV53Gy. New plan evaluation indices based on evaluating the homogeneity (IOE(H)), and conformity (IOE(C)) were introduced, considering the relative volume of each lesion and cellular density obtained from ADC images. These indices were compared with conventional homogeneity and conformity indices and IOEs without considering cellular density. Furthermore, tumor control probability (TCP) was calculated for each patient, and the relationship of the assessed indices were evaluated with TCP values.Results: IOE (H) and IOE (C) with considering cellular density had significantly lower values compared to conventional indices and IOEs without considering cellular density. (P2=-0.415), and IOE(C) without considering cell density (R2=0.624). Conclusion: IOE plan evaluation indices proposed in this study can be used for evaluating prostate IMRT dose painting plans. We suggested to consider cell densities in the IOE(H) calculation formula and it’s appropriate to calculate IOE(C) without considering cell density vaqlues.
- 4 August 2022
- Published by Springer Nature in Research Square
Open AccessIntroducing new plan evaluation indices for prostate dose painting IMRT plans based on apparent diffusion coefficient images
Background: Dose painting planning would be more complicated due to different levels of prescribed doses and more complex evaluation with conventional plan quality indices considering uniform dose prescription. Therefore, we tried to introduce new indices for evaluating the dose distribution conformity and homogeneity of treatment volumes based on the tumoral cell density and relative volumes of each lesion in prostate IMRT. Methods: CT and MRI scans of 20 male patients having local prostate cancer were used for IMRT DP planning. Apparent diffusion coefficient (ADC) images were imported to a MATLAB program to identify lesion regions based on ADC values automatically. Regions with ADC values lower than 750 mm2/s and regions with ADC values higher than 750 and less than 1500 mm2/s were considered CTV70Gy (clinical tumor volume with 70Gy prescribed dose), and CTV60Gy, respectively. Other regions of the prostate were considered as CTV53Gy. New plan evaluation indices based on evaluating the homogeneity (IOE(H)), and conformity (IOE(C)) were introduced, considering the relative volume of each lesion and cellular density obtained from ADC images. These indices were compared with conventional homogeneity and conformity indices and IOEs without considering cellular density. Furthermore, tumor control probability (TCP) was calculated for each patient, and the relationship of the assessed indices were evaluated with TCP values.Results: IOE (H) and IOE (C) with considering cellular density had significantly lower values compared to conventional indices and IOEs without considering cellular density. (P2=-0.415), and IOE(C) without considering cell density (R2=0.624). Conclusion: IOE plan evaluation indices proposed in this study can be used for evaluating prostate IMRT dose painting plans. We suggested to consider cell densities in the IOE(H) calculation formula and it’s appropriate to calculate IOE(C) without considering cell density vaqlues.
- Open Access
- 1 April 2022
- Published by CMV Verlag in International Journal of Radiation Research
- Vol. 20  (2) , 307-315
Assessment of developed IMRT and 3D-CRT planning protocols for treating nasopharyngeal cancer patients based on the target and organs at risks common volumes
Background: Various developed intensity modulated radiation therapy (IMRT) and a three dimensional conformal radiation therapy (3D-CRT) protocols were assessed for treating nasopharyngeal cancer (NPC) based on radiobiological parameters. Materials and Methods: Treatment plans were made for 30 NPC patients using 15 developed IMRT and 3D-CRT protocols. The IMRT protocols comprised of ...
- 1 April 2022
- Published by CMV Verlag in International Journal of Radiation Research
- Vol. 20  (2) , 307-315
Open AccessAssessment of developed IMRT and 3D-CRT planning protocols for treating nasopharyngeal cancer patients based on the target and organs at risks common volumes
Background: Various developed intensity modulated radiation therapy (IMRT) and a three dimensional conformal radiation therapy (3D-CRT) protocols were assessed for treating nasopharyngeal cancer (NPC) based on radiobiological parameters. Materials and Methods: Treatment plans were made for 30 NPC patients using 15 developed IMRT and 3D-CRT protocols. The IMRT protocols comprised of ...
- Open Access
- 20 January 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17  (1) , 1-16
Estimating cancer risks due to whole lungs low dose radiotherapy with different techniques for treating COVID-19 pneumonia
Background: Low dose radiotherapy (LDRT) of whole lungs with photon beams is a novel method for treating COVID-19 pneumonia. This study aimed to estimate cancer risks induced by lung LDRT for different radiotherapy delivery techniques. Method: Four different radiotherapy techniques, including 3D-conformal with anterior and posterior fields (3D-CRT AP–PA), 3D-conformal with 8 coplanar fields (3D-CRT 8 fields), eight fields intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy using 2 full arcs (VMAT) were planned on the CT images of 32 COVID-19 patients with the prescribed dose of 1 Gy to the lungs. Organ average and maximum doses, and PTV dose distribution indexes were compared between different techniques. The radiation-induced cancer incidence and cancer-specific mortality, and cardiac heart disease risks were estimated for the assessed techniques. Results: In IMRT and VMAT techniques, heart (mean and max), breast (mean, and max), and stomach (mean) doses and also maximum dose in the body were significantly lower than the 3D-CRT techniques. The calculated conformity indexes were similar in all the techniques. However, the homogeneity indexes were lower (i.e., better) in intensity-modulated techniques (P < 0.03) with no significant differences between IMRT and VMAT plans. Lung cancer incident risks for all the delivery techniques were similar (P > 0.4). Cancer incidence and mortality risks for organs located closer to lungs like breast and stomach were higher in 3D-CRT techniques than IMRT or VMAT techniques (excess solid tumor cancer incidence risks for a 30 years man: 1.94 ± 0.22% Vs. 1.68 ± 0.17%; and women: 6.66 ± 0.81% Vs. 4.60 ± 0.43%: cancer mortality risks for 30 years men: 1.63 ± 0.19% Vs. 1.45 ± 0.15%; and women: 3.63 ± 0.44% Vs. 2.94 ± 0.23%). Conclusion: All the radiotherapy techniques had low cancer risks. However, the overall estimated risks induced by IMRT and VMAT radiotherapy techniques were lower than the 3D-CRT techniques and can be used clinically in younger patients or patients having greater concerns about radiation induced cancers.
- 20 January 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17  (1) , 1-16
Open AccessEstimating cancer risks due to whole lungs low dose radiotherapy with different techniques for treating COVID-19 pneumonia
Background: Low dose radiotherapy (LDRT) of whole lungs with photon beams is a novel method for treating COVID-19 pneumonia. This study aimed to estimate cancer risks induced by lung LDRT for different radiotherapy delivery techniques. Method: Four different radiotherapy techniques, including 3D-conformal with anterior and posterior fields (3D-CRT AP–PA), 3D-conformal with 8 coplanar fields (3D-CRT 8 fields), eight fields intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy using 2 full arcs (VMAT) were planned on the CT images of 32 COVID-19 patients with the prescribed dose of 1 Gy to the lungs. Organ average and maximum doses, and PTV dose distribution indexes were compared between different techniques. The radiation-induced cancer incidence and cancer-specific mortality, and cardiac heart disease risks were estimated for the assessed techniques. Results: In IMRT and VMAT techniques, heart (mean and max), breast (mean, and max), and stomach (mean) doses and also maximum dose in the body were significantly lower than the 3D-CRT techniques. The calculated conformity indexes were similar in all the techniques. However, the homogeneity indexes were lower (i.e., better) in intensity-modulated techniques (P < 0.03) with no significant differences between IMRT and VMAT plans. Lung cancer incident risks for all the delivery techniques were similar (P > 0.4). Cancer incidence and mortality risks for organs located closer to lungs like breast and stomach were higher in 3D-CRT techniques than IMRT or VMAT techniques (excess solid tumor cancer incidence risks for a 30 years man: 1.94 ± 0.22% Vs. 1.68 ± 0.17%; and women: 6.66 ± 0.81% Vs. 4.60 ± 0.43%: cancer mortality risks for 30 years men: 1.63 ± 0.19% Vs. 1.45 ± 0.15%; and women: 3.63 ± 0.44% Vs. 2.94 ± 0.23%). Conclusion: All the radiotherapy techniques had low cancer risks. However, the overall estimated risks induced by IMRT and VMAT radiotherapy techniques were lower than the 3D-CRT techniques and can be used clinically in younger patients or patients having greater concerns about radiation induced cancers.
- Open Access
- 19 November 2021
- Published by Springer Nature in Research Square
Dosimetric Evaluation of a Set of Specifically Designed Grids for Treating Subcutaneous Superficial Tumor with 6 and 18 MeV Electron Beam External Radiotherapy
Background: Conventional electron beam radiotherapy used for treating superficial cancer tumors suffers from the disadvantage of low skin sparing effect. Furthermore, increasing electron energy for treating deeper-seated tumors leads to significant increase of skin dose. To overcome this, various grids are recommended for electron beam radiotherapy of subcutaneous tumors. However, appropriate grids are required to be designed for decreasing skin dose while delivering uniform high doses to deep-seated superficial tumors. Our goal was to design, examine and propose appropriate grid(s) for optimum electron beam radiotherapy of subcutaneous tumors with the best skin sparing with 6 and 18 MeV energies.Materials and Methods: Relevant dosimetric characteristics were determined and analyzed for five grids manufactured from dry lead having various cavity diameters (1.5, 2.0, 2.5, 3.0, 3.5 cm) and shielded areas (0.3, 0.4, 0.5, 0.6, 0.7 cm) among the cavities but the same fraction of cavity/open (68%) and shielded/closed (38%) areas under the grid plates. Isodose distributions and dose profiles resulted from the grids were investigated using EDR2 films and MATLAB software. Results: The grids with 2 and 2.5 cm diameter cavities and 0.4 and 0.5 cm shielded areas were the most appropriate grids for 6 and 18 MeV radiotherapy, respectively. With these grids, the 100% PDDs (percentage depth doses) located at 1.25 and 2.5 cm for an open filed (without the grids) were moved down to 1.87 and 5.4 cm for 6 and 18 MeV energies, respectively. Furthermore, the proposed grids provided the least peak to valley dose variations hence the most uniform doses delivered at their relevant depths of treatment. Conclusions: To decrease the skin dose in 6 and 18 MeV electron beam radiotherapy of superficial subcutaneous tumors, various home-made grids were designed and investigated. The most appropriate grids (having 2 and 2.5 cm cavity diameters for 6 and 18 MeV, respectively) provided the optimum dose delivery for superficial subcutaneous tumors locating around 1.5 and 5 cm depth for 6 and 18 MeV energies. Our comprehensive study provides reliable results that could be considered and developed more for a wider range of MeV electron grid therapies in routine clinical practices.
- 19 November 2021
- Published by Springer Nature in Research Square
Open AccessDosimetric Evaluation of a Set of Specifically Designed Grids for Treating Subcutaneous Superficial Tumor with 6 and 18 MeV Electron Beam External Radiotherapy
Background: Conventional electron beam radiotherapy used for treating superficial cancer tumors suffers from the disadvantage of low skin sparing effect. Furthermore, increasing electron energy for treating deeper-seated tumors leads to significant increase of skin dose. To overcome this, various grids are recommended for electron beam radiotherapy of subcutaneous tumors. However, appropriate grids are required to be designed for decreasing skin dose while delivering uniform high doses to deep-seated superficial tumors. Our goal was to design, examine and propose appropriate grid(s) for optimum electron beam radiotherapy of subcutaneous tumors with the best skin sparing with 6 and 18 MeV energies.Materials and Methods: Relevant dosimetric characteristics were determined and analyzed for five grids manufactured from dry lead having various cavity diameters (1.5, 2.0, 2.5, 3.0, 3.5 cm) and shielded areas (0.3, 0.4, 0.5, 0.6, 0.7 cm) among the cavities but the same fraction of cavity/open (68%) and shielded/closed (38%) areas under the grid plates. Isodose distributions and dose profiles resulted from the grids were investigated using EDR2 films and MATLAB software. Results: The grids with 2 and 2.5 cm diameter cavities and 0.4 and 0.5 cm shielded areas were the most appropriate grids for 6 and 18 MeV radiotherapy, respectively. With these grids, the 100% PDDs (percentage depth doses) located at 1.25 and 2.5 cm for an open filed (without the grids) were moved down to 1.87 and 5.4 cm for 6 and 18 MeV energies, respectively. Furthermore, the proposed grids provided the least peak to valley dose variations hence the most uniform doses delivered at their relevant depths of treatment. Conclusions: To decrease the skin dose in 6 and 18 MeV electron beam radiotherapy of superficial subcutaneous tumors, various home-made grids were designed and investigated. The most appropriate grids (having 2 and 2.5 cm cavity diameters for 6 and 18 MeV, respectively) provided the optimum dose delivery for superficial subcutaneous tumors locating around 1.5 and 5 cm depth for 6 and 18 MeV energies. Our comprehensive study provides reliable results that could be considered and developed more for a wider range of MeV electron grid therapies in routine clinical practices.
- Open Access
- 1 October 2021
- Published by CMV Verlag in International Journal of Radiation Research
- Vol. 19  (4) , 843-852
Comparison of various common whole pelvic radiotherapy (WPRT) and local radiotherapy (LRT) procedures to treat prostate cancer based on dosimetric parameters and radiobiological models
Background: Comparing three whole pelvic radiotherapy (WPRT) procedures as well as two local radiotherapy (LRT) procedures with each other for the treatment of prostate cancer patients using dosimetric parameters and radiobiological models: tumor control probability (TCP), normal tissue complication probability (NTCP), and equivalent uniform dose (EUD). Materials and Methods: Two ...
- 1 October 2021
- Published by CMV Verlag in International Journal of Radiation Research
- Vol. 19  (4) , 843-852
Open AccessComparison of various common whole pelvic radiotherapy (WPRT) and local radiotherapy (LRT) procedures to treat prostate cancer based on dosimetric parameters and radiobiological models
Background: Comparing three whole pelvic radiotherapy (WPRT) procedures as well as two local radiotherapy (LRT) procedures with each other for the treatment of prostate cancer patients using dosimetric parameters and radiobiological models: tumor control probability (TCP), normal tissue complication probability (NTCP), and equivalent uniform dose (EUD). Materials and Methods: Two ...