JOJorge Mario Fuentes Orrego

Jorge Mario Fuentes Orrego

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jorge Mario Fuentes Orrego has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Distinguishing hemangiomas from metastases on liver MRI performed with gadoxetate disodium: Value of the extended washout sign

    by Sheela Agarwal, Joseph R. Grajo, Jorge M. Fuentes-Orrego, Seyed Mahdi Abtahi, Mukesh G. Harisinghani, Sanjay Saini, Peter F. Hahn


  • A Quantitative Comparison of Noise Reduction Across Five Commercial (Hybrid and Model-Based) Iterative Reconstruction Techniques: An Anthropomorphic Phantom Study

    by Manuel Patino, Jorge M. Fuentes, Koichi Hayano, Avinash R. Kambadakone, Jennifer W. Uyeda, Dushyant V. Sahani

    OBJECTIVE. The objective of our study was to compare the performance of three hybrid iterative reconstruction techniques (IRTs) (ASiR, iDose4, SAFIRE) and their respective strengths for image noise reduction on low-dose CT examinations using filtered back projection (FBP) as the standard reference. Also, we compared the performance of these three hybrid IRTs with two model-based IRTs (Veo and IMR) for image noise reduction on low-dose examinations. MATERIALS AND METHODS. An anthropomorphic abdomen phantom was scanned at 100 and 120 kVp and different tube current-exposure time products (25-100 mAs) on three CT systems (for ASiR and Veo, Discovery CT750 HD; for iDose4 and IMR, Brilliance iCT; and for SAFIRE, Somatom Definition Flash). Images were reconstructed using FBP and using IRTs at various strengths. Nine noise measurements (mean ROI size, 423 mm(2)) on extracolonic fat for the different strengths of IRTs were recorded and compared with FBP using ANOVA. Radiation dose, which was measured as the volume CT dose index and dose-length product, was also compared. RESULTS. There were no significant differences in radiation dose and image noise among the scanners when FBP was used (p > 0.05). Gradual image noise reduction was observed with each increasing increment of hybrid IRT strength, with a maximum noise suppression of approximately 50% (48.2-53.9%). Similar noise reduction was achieved on the scanners by applying specific hybrid IRT strengths. Maximum noise reduction was higher on model-based IRTs (68.3-81.1%) than hybrid IRTs (48.2-53.9%) (p < 0.05). CONCLUSION. When constant scanning parameters are used, radiation dose and image noise on FBP are similar for CT scanners made by different manufacturers. Significant image noise reduction is achieved on low-dose CT examinations rendered with IRTs. The image noise on various scanners can be matched by applying specific hybrid IRT strengths. Model-based IRTs attain substantially higher noise reduction than hybrid IRTs irrespective of the radiation dose.


  • Inflammatory Hepatocellular Adenomas Can Mimic Focal Nodular Hyperplasia on Gadoxetic Acid–Enhanced MRI

    by Sheela Agarwal, Jorge M. Fuentes-Orrego, Thomas Arnason, Joseph Misdraji, Kartik S. Jhaveri, Mukesh Harisinghani, Peter F. Hahn

    Inflammatory hepatocellular adenoma (HCA) is a recently categorized entity of hepatocellular neoplasms. We investigated whether gadoxetic acid-enhanced MRI can distinguish inflammatory HCA from focal nodular hyperplasia (FNH). From January 1, 2009, through January 1, 2013, gadoxetic acid-enhanced MRI examinations from two institutions were reviewed for HCA, with specific histologic features of inflammatory HCA. Biopsy and resection slides were reviewed, and immunohistochemistry for glutamine synthetase was performed in a subset to confirm the initial diagnosis. A total of 10 possible cases of inflammatory HCA were identified in the pathology database. On the basis of glutamine synthetase staining performed for this study, three cases were rediagnosed as FNH and thus were excluded from the study. Therefore, a total of seven patients with inflammatory HCA were identified. On gadoxetic acid-enhanced MRI, four of these patients had classic features of FNH (group A, FNH mimics), and three had imaging features suggestive of HCA (group B, typical inflammatory HCA). Imaging features that were considered diagnostic of FNH included isointense or minimal T2 hyperintensity, arterial enhancement, and diffuse hyperintensity on hepatobiliary phase. Three of the four patients with FNH mimics had slides available for pathologic rereview, and the diagnosis of inflammatory HCA was supported by glutamine synthetase immunohistochemistry findings. The pathology reports of the remaining four cases were rereviewed and were also found to have features consistent with inflammatory HCA. Inflammatory HCA can mimic FNH on MRI, including hepatobiliary phase hyperintensity. Moreover, conventional pathology using histopathology alone may lead to misclassification of inflammatory HCA.


  • New and Evolving Concepts in CT for Abdominal Vascular Imaging

    by Jorge M. Fuentes-Orrego, Daniella Pinho, Naveen M. Kulkarni, Mukta Agrawal, Brian B. Ghoshhajra, Dushyant V. Sahani

    Computed tomographic (CT) angiography has become the standard of care, supplanting invasive angiography for comprehensive initial evaluation of acute and chronic conditions affecting the vascular system in the abdomen and elsewhere. Over the past decade, the capabilities of CT have improved substantially; simultaneously, the expectations of the referring physician and vascular surgeons have also evolved. Increasingly, CT angiography is used as an imaging biomarker for treatment selection and assessment of effectiveness. However, the growing use of CT angiography has also introduced some challenges, as potential radiation-associated and contrast media-induced risks need to be addressed. These concerns can be partly confronted by modifying scanning parameters (applying a low tube voltage) with or without using software-based solutions. Most recently, multienergy technology has endowed CT with new capabilities offering improved CT angiographic image quality and novel plaque characterization while decreasing radiation and iodine dose. In this article, we discuss current and new approaches using both conventional and multienergy CT for studying vascular disease in the abdomen. We propose various approaches to overcoming commonly encountered image quality challenges in CT angiography. In addition, we describe supplemental strategies for improving patient safety that leverage the available technology. (C) RSNA, 2014


  • Stratification of Patients With Liver Fibrosis Using Dual-Energy CT

    by Peter Lamb, Dushyant V. Sahani, Jorge M. Fuentes-Orrego, Manuel Patino, Asish Ghosh, Paulo R. S. Mendonca

    Assessing the severity of liver fibrosis has direct clinical implications for patient diagnosis and treatment. Liver biopsy, typically considered the gold standard, has limited clinical utility due to its invasiveness. Therefore, several imaging-based techniques for staging liver fibrosis have emerged, such as magnetic resonance elastography (MRE) and ultrasound elastography (USE), but they face challenges that include limited availability, high cost, poor patient compliance, low repeatability, and inaccuracy. Computed tomography (CT) can address many of these limitations, but is still hampered by inaccuracy in the presence of confounding factors, such as liver fat. Dual-energy CT (DECT), with its ability to discriminate between different tissue types, may offer a viable alternative to these methods. By combining the "multi-material decomposition" (MMD) algorithm with a biologically driven hypothesis we developed a method for assessing liver fibrosis from DECT images. On a twelve-patient cohort the method produced quantitative maps showing the spatial distribution of liver fibrosis, as well as a fibrosis score for each patient with statistically significant correlation with the severity of fibrosis across a wide range of disease severities. A preliminary comparison of the proposed algorithm against MRE showed good agreement between the two methods. Finally, the application of the algorithm to longitudinal DECT scans of the cohort produced highly repeatable results. We conclude that our algorithm can successfully stratify patients with liver fibrosis and can serve to supplement and augment current clinical practice and the role of DECT imaging in staging liver fibrosis.


  • Dose-modified 256-MDCT of the Abdomen Using Low Tube Current and Hybrid Iterative Reconstruction

    by Jorge M. Fuentes-Orrego, Koichi Hayano, Avinash R. Kambadakone, Peter F. Hahn, Dushyant V. Sahani


  • New Liver Imaging Techniques

    by Mukta D. Agrawal, Sheela Agarwal, Jorge M. Fuentes-Oreego, Koichi Hayano, Dushyant V. Sahani


  • Low-dose CT in clinical diagnostics

    by Jorge M Fuentes-Orrego, Dushyant V Sahani, Md

    Computed tomography (CT) has become key for patient management due to its outstanding capabilities for detecting disease processes and assessing treatment response, which has led to expansion in CT imaging for diagnostic and image-guided therapeutic interventions. Despite these benefits, the growing use of CT has raised concerns as radiation risks associated with radiation exposure. The purpose of this article is to familiarize the reader with fundamental concepts of dose metrics for assessing radiation exposure and weighting radiation-associated risks. The article also discusses general approaches for reducing radiation dose while preserving diagnostic quality. The authors provide additional insight for undertaking protocol optimization, customizing scanning techniques based on the patients' clinical scenario and demographics. Supplemental strategies are postulated using more advanced post-processing techniques for achieving further dose improvements. The technologic offerings of CT are integral to modern medicine and its role will continue to evolve. Although, the estimated risks from low levels of radiation of a single CT exam are uncertain, it is prudent to minimize the dose from CT by applying common sense solutions and using other simple strategies as well as exploiting technologic innovations. These efforts will enable us to take advantage of all the clinical benefits of CT while minimizing the likelihood of harm to patients.


  • Performance of Iterative Reconstruction and Automated Tube Voltage Selection on the Image Quality and Radiation Dose in Abdominal CT Scans

    by Gaurav S. Desai, Jorge M. Fuentes Orrego, Avinash R. Kambadakone, Dushyant V. Sahani

    Objective To study the impact of sinogram-affirmed iterative reconstruction (SAFIRE) and concurrent application of automated tube voltage selection (ATVS) on image quality (IQ) and radiation dose. Methods A phantom was scanned using various computed tomography (CT) parameters (kV, 80–120; mAs, 50–200). Abdomen contrast-enhanced CT (CECTs) in 170 adults were performed using dose-modified protocols: in 145 patients (group I), ATVS was applied (mAs, 111–649); in 25 (group II), the kV was fixed at 120 (reference mAs, 150). In 95 patients, standard-dose (SD) scan was available. Two readers evaluated the IQ of filtered back projection (FBP) and SAFIRE (levels 1, 3, and 5) images. Results In phantom, nonlinear drop in noise with increasing strengths of IR (levels S1–S5) was noted. The dose-modified IR scan was rated diagnostic in all 170 patients, with IQ score comparable to that of SD-FBP (P = 0.3). Lower kV (100/80) was prescribed by ATVS in 70% examinations in group I. In comparison with SD-FBP, the mean dose in CT dose index in group I (IR, 3.2 mGy; SD-FBP, 13.02 mGy; P < 0.0001) and in group II (IR, 4.8 mGy; SD-FBP, 11.8 mGy; P < 0.001) was 75.4% and 59.3% lower. Conclusions Use of SAFIRE and ATVS provides diagnostic quality images at 59.3% to 75.4% reduced dose compared with SD-FBP scan.


  • Open Access

    Quantitative characterization of hepatocellular carcinoma and metastatic liver tumor by CT perfusion

    by Koichi Hayano, Gaurav S. Desai, Avinash R. Kambadakone, Jorge M. Fuentes, Kenneth K. Tanabe, Dushyant V. Sahani

    To evaluate the diagnostic value of computed tomography perfusion (CTP) in the distinction of hepatocellular carcinomas (HCCs) from metastatic liver tumors. CTP data from 90 liver tumors (HCC 38, metastasis 52) in 31 patients (16 men and 15 women; mean age 60.3 years) were studied. CTP was performed on a 16/64 multidetector-row CT scanner using a 30-s duration cine acquisition after rapid bolus injection (5-7 ml/s) of 50-70 ml of iodinated contrast medium. The CTP data were analyzed using a deconvolution model. Metastatic tumors were grouped into hypovascular (n = 36) and hypervascular (n = 16) tumors. The hypovascular metastases showed a significantly lower blood flow (BF) and blood volume (BV), and higher mean transit time (MTT) than HCC (all P < 0.0001). BF, BV, and MTT of HCCs were substantially lower than those of hypervascular metastases (P = 0.02, P < 0.0001, P = 0.03, respectively). A receiver-operating characteristic analysis showed that BV was a useful marker to distinguish HCCs from hypervascular metastases.