AJAdria Junyent-Ferre

Adria Junyent-Ferre

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adria Junyent-Ferre has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Safe Deep Reinforcement Learning Approach to Mitigating Demand Response Load Rebounds for TSOs

    by Pau Fisco-Compte, Adrià Junyent-Ferré, Marc Juanpera, Matteo Ranaboldo, Eduard Bullich-Massagué, Andreas Sumper

    Industrial demand response is essential for grid stability amid increasing variable renewable energy penetration. However, explicit demand response adoption is hindered by post-activation demand spikes, known as load rebounds. This paper proposes a methodology for transmission system operators to manage load rebounds in high-voltage networks with limited supply-side flexibility. First, a rolling-horizon model combining mixed-integer linear and constraint programming schedules an energy-intensive steel plant under implicit and explicit demand response programmes and generates feasible flexibility offers for balancing markets. Second, the industrial model is embedded in a modified high-voltage CIGRE stress-test network to simulate load rebounds after flexibility activations. Finally, in a safe deep reinforcement learning approach, a recurrent Proximal Policy Optimisation agent dispatches distributed demand-side flexibility and the reactive power of static var compensators to manage the network and mitigate load rebounds. A safety projection verifies each action of the agent with a power flow and, when an operational limit is violated, corrects it with a quadratic program built on exact power flow sensitivities; when no safe action exists, the action of minimal measured violation is applied. Compared with local voltage control alone, the agent reduces the hours with voltage violations from 12.2\% to 1.2\% and those with line loadings above the operational limit of 80\% of the thermal rating from 45.9\% to 3.6\%, with limited demand-side and no supply-side flexibility. The results support coordination schemes between transmission and distribution system operators in which distributed flexibility absorbs the rebounds of large industrial activations, enabling broader industrial participation in balancing markets through dynamic, voluntary flexibility.

  • Top Cited Papers
    Open Access

    Data center workload flexibility for power system demand response: Evidence from Alibaba traces

    by Adriano Caprara, Ying Yu, Fei Teng, Adrià Junyent-Ferré, Eduard Bullich-Massagué, Mònica Aragüés-Peñalba


  • Hybrid Frequency-Phase-Shift Modulation with Natural Synchronous Rectification for CLLC Converters

    by Chengwei Liu, Huan Chen, Leheng Wang, Kai Zhang, Kai Sun, Adrià Junyent-Ferré

    Synchronous rectification (SR) is an effective method to improve the efficiency of the CLLC resonant converter. However, existing SR methods typically rely on calculating specific SR angles based on pulse frequency modulation (PFM) or phase shift modulation (PSM), which do not overcome the intrinsic efficiency drawbacks of these modulations. To address this, this paper proposes a hybrid modulation that integrates switching frequency and phase shift to achieve natural SR and modulation optimization simultaneously. Rather than SR angle calculation, the proposed modulation combines the two control variables to synchronize the operation of the primary side switches and secondary side rectifiers (diodes or SR switches). This alignment enables natural SR by gating the secondary switches concurrently with the primary switches. Furthermore, the proposed modulation reduces the RMS value of inductor current and extends the ZVS range compared to PSM. In contrast to PFM, the proposed method operates at a lower switching frequency, thereby reducing switching losses. The modulation is achieved by a closed-loop control for switching frequency and a precomputed fitting curve for phase shift. A series of experimental results have verified the effectiveness of the proposed modulation.

  • Model Order Reduction of Large-Scale Wind Farms: A Data-Driven Approach

    by Zilong Gong, Junyu Mao, Adrià Junyent-Ferré, Giordano Scarciotti

    This paper proposes a data-driven algorithm for model order reduction (MOR) of large-scale wind farms and studies the effects that the obtained reduced-order model (ROM) has when this is integrated into the power grid. With respect to standard MOR methods, the proposed algorithm has the advantages of having low computational complexity and not requiring any knowledge of the high order model. Using time-domain measurements, the obtained ROM achieves the moment matching conditions at selected interpolation points (frequencies). With respect to the state of the art, the method achieves the so-called two-sided moment matching, doubling the accuracy by doubling the interpolated points. The proposed algorithm is validated on a combined model of a 200-turbine wind farm (which is reduced) interconnected to the IEEE 14-bus system (which represents the unreduced study area) by comparing the full-order model and the reduced-order model in terms of their Bode plots, eigenvalues and the point of common coupling voltages in extensive fault scenarios of the integrated power system.


  • Open Access

    A fault detection and location algorithm for the LVDC interconnection network in rural area

    by Chengwei Liu, Joan Marc Rodriguez‐Bernuz, Di Liu, Saizhao Yang, Yitong Li, Qiteng Hong, Adrià Junyent‐Ferré

    Low voltage DC (LVDC) microgrids (MGs) can be linked together through an interconnection network to enhance the utilization of their energy resources in remote locations, particularly in rural low‐income areas. However, the identification of the fault is challenging due to the fast fault transients and equipment limitations, where there are no sensors and DC circuit breakers (DCCBs) in the lines. To solve this problem, this article proposes a fault detection and location algorithm without requiring extra sensors and DCCBs in lines. The proposed algorithm uses the sensors of the interface converters to detect the fault. Following this, a coordinated current injection method is used to identify the faulty element by coordinating converters with disconnectors. This process employs two strategies “weight check” and “scope check” to minimize the time and the number of actions. The algorithm is robust to various fault impedance, fault types and network topology modifications. The effectiveness of the algorithm is validated through a series of simulation case studies.


  • Open Access

    Adaptive Single-Terminal Fault Location for DC Microgrids

    by Vaibhav Nougain, Sukumar Mishra, Joan-Marc Rodriguez-Bernuz, Adria Junyent-Ferre, Aditya Shekhar, Aleksandra Lekic

    Identifying faulty lines and their accurate location is key for rapidly restoring distribution systems. This will become a greater challenge as the penetration of power electronics increases, and contingencies are seen across larger areas. This paper proposes a single terminal methodology (i.e., no communication involved) that is robust to variations of key parameters (e.g., sampling frequency, system parameters, etc.) and performs particularly well for low resistance faults that constitute the majority of faults in low voltage DC systems. The proposed method uses local measurements to estimate the current caused by the other terminals affected by the contingency. This mimics the strategy followed by double terminal methods that require communications and decouples the accuracy of the methodology from the fault resistance. The algorithm takes consecutive voltage and current samples, including the estimated current of the other terminal, into the analysis. This mathematical methodology results in a better accuracy than other single-terminal approaches found in the literature. The robustness of the proposed strategy against different fault resistances and locations is demonstrated using MATLAB simulations.

  • Open Access

    Personalized Federated Learning With Cost-Oriented Load Forecasting for Home Energy Management Systems

    by Sara Barja-Martinez, Fei Teng, Adrià Junyent-Ferré, Mònica Aragüés-Peñalba

    Accurate day-ahead demand forecasting is crucial for optimizing the performance of home energy management systems. Traditional forecasting methods often decouple the forecasting task and the subsequent decision marking, resulting in imbalanced economic penalties from load deviations. Furthermore, the rise of digitization has led to a massive increase in fine-grained smart meter data stored daily, posing significant challenges to customers' data privacy and security. To address these technical challenges, this study proposes a personalized federated learning methodology that incorporates a cost-oriented loss function. This methodology is designed to learn end-user-specific patterns, reduce penalization costs, and preserve customer privacy. Comparative analyses reveal that the proposed method, which utilizes a cost-oriented loss function and $L^{2}$ regularization, outperforms traditional symmetric loss functions in terms of efficiency and economic benefits. The results confirm that this personalized federated learning approach consistently achieves the lowest error rates and penalization costs compared to other methods. Additionally, sensitivity analyses indicate that even households with limited historical consumption data can achieve accurate load predictions using the personalized federated learning approach.


  • Open Access

    E-bike load demand estimation for transport using cartographic data

    by Aimable Ngendahayo, Adrià Junyent-Ferré, Joan-Marc Rodriguez-Bernuz, Etienne Ntagwirumugara

    In remote areas of Sub-Saharan Africa, as well as in Rwanda, communities face the problem of finding an affordable and suitable way of transport for their daily life. Currently, the short-range transportation of people and goods rely on manual traction (e.g., bicycles, handmade wooden bicycle, etc.) and on small combustion engines. However, this region has a large renewable energy source (solar) which can help to mitigate this problem. Electric bicycles may be used to tackle the problem, although their use is still not largely widespread despite its potential. In addition, the local society does not have an easy way to accurately estimate the amount of energy consumed for a certain itinerary to be sure of how the electric vehicles perform. Thus, characteristic analysis of consumed energy is very important to analyze the performance of electric vehicle storage systems, model charging infrastructure, size vehicles, planning for itineraries, etc. This paper presents a methodology to estimate the power consumed by electric bikes for specific itineraries. In order to accomplish so, the WebPlotDigitizer tool and Google Maps were used to produce driving profile patterns. The results are compared against experimental data, showing the accuracy of the methodology presented. The simulated results show that the consumed power value differs by only 1.68% from the experimental recorded value; the difference can be explained by traffic congestion, the density of traffic, and the intersection that occurred during the experiment. The presented method of driving energy requirement estimation using WebPlotDigitizer is attractive, affordable, and easy to use.

  • An Inductance-Current-Minimization Optimization Scheme Based on Hardware Decoupling for Modular Multi-Active-Bridge Converter

    by Chengwei Liu, Di Mou, Yitong Li, Ka-Hong Loo, Vardan Saxena, Xiao Du, Adrià Junyent-Ferré

    Modular multiactive-bridge (MMAB) converter is increasingly recognized as a potential solution for efficient power conversion in the integration of distributed energy resources, storage systems, and loads. However, optimizing MMAB converters for high-efficiency operation remains a challenge due to the inherent coupling across ports. To address this problem, this article proposes an inductance-current-minimization optimization scheme based on a hardware decoupling method. The decoupling across ports is achieved by eliminating the inductance at one of the ports, which simplifies the complexity of the system significantly. Based on the decoupled MMAB converter, an optimization scheme is proposed to minimize the root mean square value of the inductor current. Compared with the conventional modulation scheme, this scheme can reduce the inductor current and expand the soft-switching region across various power ranges and voltage ratios, thereby enhancing the operation efficiency. Furthermore, the proposed scheme is based on analytical solutions, enabling online implementation without the need for lookup tables and scalable to accommodate any number of ports. The effectiveness of the proposed scheme has been verified by a series of simulations and experiments based on a four-port MMAB converter prototype.