Takamitsu Okada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takamitsu Okada has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Naoya Kozono
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Japan
16 shared publications Hidehiko Higaki
Department of Life Science, Faculty of Life Science, Kyushu Sangyo University, 2-3-1, Matsukadai, Higashi-ku, Fukuoka City, Fukuoka 813-8503, Japan
12 shared publicationsTakeshi Shimoto
Department of Information and System Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1, Higashi-ku, Fukuoka City, Fukuoka 811-0295, Japan
11 shared publicationsNaohide Takeuchi
Department of Orthopaedic Surgery, School of Medicine, Kyushu University, 3-1-1, Maidashi, Higashiku, Fukuoka-shi, Fukuoka, 812-8582, Japan
6 shared publications- Yoshitaka Nakanishi
Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto, Japan
6 shared publications - Satoshi Hamai
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
5 shared publications
Latest Publications
- Open Access
- 1 December 2019
- Published by Elsevier in Regenerative Therapy
- Vol. 11, 47-55
Histological evaluation of tendon formation using a scaffold-free three-dimensional-bioprinted construct of human dermal fibroblasts under in vitro static tensile culture
- 1 December 2019
- Published by Elsevier in Regenerative Therapy
- Vol. 11, 47-55
Open AccessHistological evaluation of tendon formation using a scaffold-free three-dimensional-bioprinted construct of human dermal fibroblasts under in vitro static tensile culture
- 1 October 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 69, 191-196
Biomechanical analysis of four different medial row configurations of suture bridge rotator cuff repair
- 1 October 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 69, 191-196
Biomechanical analysis of four different medial row configurations of suture bridge rotator cuff repair
- 1 March 2019
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 258-262
Evaluation of humeral head cartilage using magnetic resonance imaging T1 rho mapping for patients with small-to-medium rotator cuff tears: A pilot study
- 1 March 2019
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 258-262
Evaluation of humeral head cartilage using magnetic resonance imaging T1 rho mapping for patients with small-to-medium rotator cuff tears: A pilot study
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2019, 1P2-B10
Analyze the relative relationship between the head of humerus and the glenoid of scapula using kinetic analysis software for natural joint.
In the field of orthopedics, it is important to analyze the kinetics of the shoulder joint. Our research group can analyze kinetic analysis of shoulder joints with high accuracy using the software developed. Kinetic analysis calculates six degrees of freedom of the humerus and scapula. This result is also important, however in the shoulder it is important to analyze the movement of the humeral head relative to the glenoid of scapula. Therefore, based on six degrees of freedom data, the relative relationship of bones on 3D-CAD was reproduced and the relative relationship between the humeral head and the glenoid of scapula was analyzed. We focused on the shoulder kinematics about dynamic scapular plane full abduction. Patients with rotator cuff tears and healthy subjects were seven and ten, respectively. As a result, the difference between the normal shoulder and the rotator cuff tears in scapular plane full abduction was confirmed.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2019, 1P2-B10
Analyze the relative relationship between the head of humerus and the glenoid of scapula using kinetic analysis software for natural joint.
In the field of orthopedics, it is important to analyze the kinetics of the shoulder joint. Our research group can analyze kinetic analysis of shoulder joints with high accuracy using the software developed. Kinetic analysis calculates six degrees of freedom of the humerus and scapula. This result is also important, however in the shoulder it is important to analyze the movement of the humeral head relative to the glenoid of scapula. Therefore, based on six degrees of freedom data, the relative relationship of bones on 3D-CAD was reproduced and the relative relationship between the humeral head and the glenoid of scapula was analyzed. We focused on the shoulder kinematics about dynamic scapular plane full abduction. Patients with rotator cuff tears and healthy subjects were seven and ten, respectively. As a result, the difference between the normal shoulder and the rotator cuff tears in scapular plane full abduction was confirmed.
- 1 December 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 60, 95-99
In vivo dynamic acromiohumeral distance in shoulders with rotator cuff tears
- 1 December 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 60, 95-99
In vivo dynamic acromiohumeral distance in shoulders with rotator cuff tears
- Open Access
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Dynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Open AccessDynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 1 January 2018
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 43 (1) , 79.e1-79.e8
A Biomechanical Comparison Between Asymmetric Pennington Technique and Conventional Core Suture Techniques: 6-Strand Flexor Tendon Repair
- 1 January 2018
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 43 (1) , 79.e1-79.e8
A Biomechanical Comparison Between Asymmetric Pennington Technique and Conventional Core Suture Techniques: 6-Strand Flexor Tendon Repair
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 2C13
Strength Evaluation of Asymmetric 6-strands Pennington modified Kessler core suture in Flexor Tendon Repair
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 2C13
Strength Evaluation of Asymmetric 6-strands Pennington modified Kessler core suture in Flexor Tendon Repair
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- Open Access
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 84 (859) , 17-00191
Evaluation of suture strength of asymmetric six-strands pennington suture in finger flexor tendon suture
For the medical treatment of damage or ruptures in the flexor digital tendon, finger flexor tendon suture surgery is utilized. In previous studies, various core suture methods have indicated that important factors affect biomechanical properties, including the number of suture strands. In many suture methods, Fore-strands core suture and Six-strands core suture are used. Recently, asymmetric sutures have been reported to be effective in the gap formation. However, what has not been studied is the optimal asymmetry or required degree of asymmetry. Therefore, this study was aimed to evaluate the strength in asymmetric core sutures under cyclic load testing. Porcine flexor tendons were used in this study. We sutured porcine flexor tendons using combinations of six-strands Pennington suture and interlocking cross-stitch peripheral suture. This study looked at one symmetrical and five types of asymmetrical six-strands Pennington suture. In reference to the suture standard suture length (10 mm) from the end of the porcine flexor tendon, an asymmetric suture was shifted 1 mm, 2 mm, 3 mm, 4 mm and 5 mm from the reference position, respectively. This experiment was performed under cyclic load testing using an evaluation simulator our research group developed. A 2 N preload was applied to each of the sutured tendons. Tendons were tested with an initial load of 10 N for 500 cycles. If no evidence of failure was noted after the 500 cycles, the force was increased by 5 N for each additional 500 cycles. This procedure was continued until rupture. The sutured tendons were pulled at a constant distraction rate of 300 mm/min. As a result, tendons with 2 mm or more asymmetry had significantly greater the number of cycles to rupture than tendons with symmetry and with 3 mm or more asymmetry had significantly greater the number of cycles to rupture than tendons with asymmetry 1 mm. Tendons with 3 mm or more asymmetry had significantly less gap formation than tendons with symmetry. Furthermore, tendons with asymmetry 3 mm and 4 mm had significantly less gap formation than tendons with asymmetry 1 mm. Asymmetry 3 mm was the highest in both number of cycles to rupture and fatigue strength. Furthermore, it had the smallest value in the gap formation. Therefore, our results support that asymmetry 3 mm produces better beneficial had results compared to the others.
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 84 (859) , 17-00191
Open AccessEvaluation of suture strength of asymmetric six-strands pennington suture in finger flexor tendon suture
For the medical treatment of damage or ruptures in the flexor digital tendon, finger flexor tendon suture surgery is utilized. In previous studies, various core suture methods have indicated that important factors affect biomechanical properties, including the number of suture strands. In many suture methods, Fore-strands core suture and Six-strands core suture are used. Recently, asymmetric sutures have been reported to be effective in the gap formation. However, what has not been studied is the optimal asymmetry or required degree of asymmetry. Therefore, this study was aimed to evaluate the strength in asymmetric core sutures under cyclic load testing. Porcine flexor tendons were used in this study. We sutured porcine flexor tendons using combinations of six-strands Pennington suture and interlocking cross-stitch peripheral suture. This study looked at one symmetrical and five types of asymmetrical six-strands Pennington suture. In reference to the suture standard suture length (10 mm) from the end of the porcine flexor tendon, an asymmetric suture was shifted 1 mm, 2 mm, 3 mm, 4 mm and 5 mm from the reference position, respectively. This experiment was performed under cyclic load testing using an evaluation simulator our research group developed. A 2 N preload was applied to each of the sutured tendons. Tendons were tested with an initial load of 10 N for 500 cycles. If no evidence of failure was noted after the 500 cycles, the force was increased by 5 N for each additional 500 cycles. This procedure was continued until rupture. The sutured tendons were pulled at a constant distraction rate of 300 mm/min. As a result, tendons with 2 mm or more asymmetry had significantly greater the number of cycles to rupture than tendons with symmetry and with 3 mm or more asymmetry had significantly greater the number of cycles to rupture than tendons with asymmetry 1 mm. Tendons with 3 mm or more asymmetry had significantly less gap formation than tendons with symmetry. Furthermore, tendons with asymmetry 3 mm and 4 mm had significantly less gap formation than tendons with asymmetry 1 mm. Asymmetry 3 mm was the highest in both number of cycles to rupture and fatigue strength. Furthermore, it had the smallest value in the gap formation. Therefore, our results support that asymmetry 3 mm produces better beneficial had results compared to the others.