AMAllan Maas

Allan Maas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Allan Maas has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Patellar thickness can critically impact knee joint biomechanics after total knee arthroplasty

    by Ning Guo, Allan Maas, Thomas M. Grupp, Pascal Schütz, Henning Windhagen, William R. Taylor, Seyyed Hamed Hosseini Nasab

    Aims: Despite the potential benefits of an increased moment arm of the knee extensor mechanism with a thicker patellar button in patients undergoing total knee arthroplasty (TKA), many surgeons are reluctant to alter the natural patellar thickness (PTh) during resurfacing. Clinically, this hesitation stems from concerns about straining the extensor apparatus under passive motion exercises and the potential consequences on postoperative joint biomechanics, but also because many patients with a thinner patella experience improved functionality, range of motion, and possibly also reduced soft-tissue pain in the short term postoperatively. However, the biomechanical relationships underlying such short- and long-term consequences remain unexplored. Our aim was to investigate the influence of PTh on knee biomechanics after TKA. Methods: This study used advanced computational modelling techniques to undertake a systematic exploration of the influence of PTh variation on knee joint kinematics, contact mechanics, and muscle and soft-tissue loading patterns during level walking and squatting. Results: Our results indicate that increased PTh efficiency enhances the extensor mechanism, which is consistent with previous studies, but our investigation additionally demonstrates the reduction in tibiofemoral loading conditions, especially at higher flexion angles. Conversely, a thinner patella induces reduced patellofemoral contact forces and pressure, and may offer increased joint range of motion. Conclusion: PTh was found to influence knee biomechanics in clinically relevant ways. A modest increase in thickness improved quadriceps efficiency and reduced tibiofemoral forces by up to ~10%, but also raised patellofemoral pressures by up to ~5 MPa. Conversely, thinner buttons lowered patellofemoral loading and may facilitate early comfort and flexion. These trade-offs were consistent across implant congruency designs, highlighting the need for patient-specific resurfacing strategies. Cite this article: Bone Joint Res 2026;15(5):472–481.

  • Open Access

    Machine Learning-Based Estimation of Knee Joint Mechanics from Kinematic and Neuromuscular Inputs: A Proof-of-Concept Using the CAMS-Knee Datasets

    by Yara N. Derungs, Martin Bertsch, Kushal Malla, Allan Maas, Thomas M. Grupp, Adam Trepczynski, Philipp Damm, Seyyed Hamed Hosseini Nasab

    This study explores the feasibility of estimating tibiofemoral joint contact forces using deep learning models trained on in vivo biomechanical data. Leveraging the comprehensive CAMS-Knee datasets, we developed and evaluated two machine learning network architectures, a bidirectional Long Short-Term-Memory Network with a Multilayer Perceptron (biLSTM-MLP) and a Temporal Convolutional Network (TCN) model, to predict medial and lateral knee contact forces (KCFs) across various activities of daily living. Using a leave-one-subject-out validation approach, the biLSTM-MLP model achieved root mean square errors (RMSEs) as low as 0.16 body weight (BW) and Pearson correlation coefficients up to 0.98 for the total KCF (Ftot) during walking. Although the prediction of individual force components showed slightly lower accuracy, the model consistently demonstrated high predictive accuracy and strong temporal coherence. In contrast to the biLSTM-MLP model, the TCN model showed more variable performance across force components and activities. Leave-one-feature-out analyses underscored the dominant role of lower-limb kinematics and ground reaction forces in driving model accuracy, while EMG features contributed only marginally to the overall predictive performance. Collectively, these findings highlight deep learning as a scalable and reliable alternative to traditional musculoskeletal simulations for personalized knee load estimation, establishing a foundation for future research on larger and more heterogeneous populations.


  • Open Access

    Knee contact force alone is insufficient to validate joint mechanics in musculoskeletal models

    by Ning Guo, Allan Maas, Thomas M. Grupp, Adam Trepczynski, Philipp Damm, William R. Taylor, Seyyed Hamed Hosseini Nasab


  • Open Access

    On the consequences of intra-operative release versus over-tensioning of the posterior cruciate ligament in total knee arthroplasty

    by Seyyed Hamed Hosseini Nasab, Sabrina Hörmann, Thomas M. Grupp, William R. Taylor, Allan Maas

    Intra-operative tensioning of the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) is commonly based on the surgeon’s experience, resulting in a possibly loose or overly tight PCL. To date, the consequences of different PCL tensioning scenarios for the post-operative biomechanics of the knee remain unclear. Using a comprehensive musculoskeletal modelling approach that allows predictive joint kinematic and kinetic balance, we assessed variations in the movement and loading patterns of the knee as well as changes in ligament and muscle forces during walking in response to systematic variations in the PCL reference strain. The results indicate only small differences in the tibiofemoral and patellofemoral kinematics and kinetics for scenarios involving up to 10% release of the PCL (relative to the baseline reference scenario with 2% residual strain). These observations remain valid for simulations performed with high- as well as with low-conformity implant designs. However, over-tensioning of the ligament was found to considerably overload the tibiofemoral joint, including altered contact mechanics, and may therefore shorten the implant longevity. Finally, no meaningful impact of the PCL reference strain on the muscle force patterns was observed. This study therefore favours balancing the knee with a slightly loose rather than tense PCL, if appropriate intra-operative PCL tension cannot be objectively achieved.


  • Open Access

    Comparison of IMU-Based Knee Kinematics with and without Harness Fixation against an Optical Marker-Based System

    by Jana G. Weber, Ariana Ortigas-Vásquez, Adrian Sauer, Ingrid Dupraz, Michael Utz, Allan Maas, Thomas M. Grupp

    The use of inertial measurement units (IMUs) as an alternative to optical marker-based systems has the potential to make gait analysis part of the clinical standard of care. Previously, an IMU-based system leveraging Rauch–Tung–Striebel smoothing to estimate knee angles was assessed using a six-degrees-of-freedom joint simulator. In a clinical setting, however, accurately measuring abduction/adduction and external/internal rotation of the knee joint is particularly challenging, especially in the presence of soft tissue artefacts. In this study, the in vivo IMU-based joint angles of 40 asymptomatic knees were assessed during level walking, under two distinct sensor placement configurations: (1) IMUs fixed to a rigid harness, and (2) IMUs mounted on the skin using elastic hook-and-loop bands (from here on referred to as “skin-mounted IMUs”). Estimates were compared against values obtained from a harness-mounted optical marker-based system. The comparison of these three sets of kinematic signals (IMUs on harness, IMUs on skin, and optical markers on harness) was performed before and after implementation of a REference FRame Alignment MEthod (REFRAME) to account for the effects of differences in coordinate system orientations. Prior to the implementation of REFRAME, in comparison to optical estimates, skin-mounted IMU-based angles displayed mean root-mean-square errors (RMSEs) up to 6.5°, while mean RMSEs for angles based on harness-mounted IMUs peaked at 5.1°. After REFRAME implementation, peak mean RMSEs were reduced to 4.1°, and 1.5°, respectively. The negligible differences between harness-mounted IMUs and the optical system after REFRAME revealed that the IMU-based system was capable of capturing the same underlying motion pattern as the optical reference. In contrast, obvious differences between the skin-mounted IMUs and the optical reference indicated that the use of a harness led to fundamentally different joint motion being measured, even after accounting for reference frame misalignments. Fluctuations in the kinematic signals associated with harness use suggested the rigid device oscillated upon heel strike, likely due to inertial effects from its additional mass. Our study proposes that optical systems can be successfully replaced by more cost-effective IMUs with similar accuracy, but further investigation (especially in vivo and upon heel strike) against moving videofluoroscopy is recommended.


  • Open Access

    Validation of Inertial-Measurement-Unit-Based Ex Vivo Knee Kinematics during a Loaded Squat before and after Reference-Frame-Orientation Optimisation

    by Svenja Sagasser, Adrian Sauer, Christoph Thorwächter, Jana G. Weber, Allan Maas, Matthias Woiczinski, Thomas M. Grupp, Ariana Ortigas-Vásquez

    Recently, inertial measurement units have been gaining popularity as a potential alternative to optical motion capture systems in the analysis of joint kinematics. In a previous study, the accuracy of knee joint angles calculated from inertial data and an extended Kalman filter and smoother algorithm was tested using ground truth data originating from a joint simulator guided by fluoroscopy-based signals. Although high levels of accuracy were achieved, the experimental setup leveraged multiple iterations of the same movement pattern and an absence of soft tissue artefacts. Here, the algorithm is tested against an optical marker-based system in a more challenging setting, with single iterations of a loaded squat cycle simulated on seven cadaveric specimens on a force-controlled knee rig. Prior to the optimisation of local coordinate systems using the REference FRame Alignment MEthod (REFRAME) to account for the effect of differences in local reference frame orientation, root-mean-square errors between the kinematic signals of the inertial and optical systems were as high as 3.8° ± 3.5° for flexion/extension, 20.4° ± 10.0° for abduction/adduction and 8.6° ± 5.7° for external/internal rotation. After REFRAME implementation, however, average root-mean-square errors decreased to 0.9° ± 0.4° and to 1.5° ± 0.7° for abduction/adduction and for external/internal rotation, respectively, with a slight increase to 4.2° ± 3.6° for flexion/extension. While these results demonstrate promising potential in the approach’s ability to estimate knee joint angles during a single loaded squat cycle, they highlight the limiting effects that a reduced number of iterations and the lack of a reliable consistent reference pose inflicts on the sensor fusion algorithm’s performance. They similarly stress the importance of adapting underlying assumptions and correctly tuning filter parameters to ensure satisfactory performance. More importantly, our findings emphasise the notable impact that properly aligning reference-frame orientations before comparing joint kinematics can have on results and the conclusions derived from them.


  • Open Access

    A Reproducible and Robust Representation of Tibiofemoral Kinematics of the Healthy Knee Joint during Stair Descent using REFRAME – Part I: REFRAME Foundations and Validation

    by Ariana Ortigas-Vásquez, William R. Taylor, Barbara Postolka, Pascal Schütz, Allan Maas, Matthias Woiczinski, Thomas M. Grupp, Adrian Sauer

    In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by a lack of consensus around joint coordinate frame definitions, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation. Consequently, for consistent interpretation of joint motion (especially direct comparison) to be possible, differences in local frame position and orientation must first be addressed. Here, building on previous work that introduced a frame orientation optimisation method and demonstrated its potential to induce convergence towards a consistent kinematic signal, we present the REference FRame Alignment MEthod (REFRAME) that addresses both rotational and translational kinematics, is validated here for a healthy tibiofemoral joint, and allows flexible selection of optimisation criteria to fittingly address specific research questions. While not claiming to improve the accuracy of joint kinematics or reference frame axes, REFRAME does enable a representation of knee kinematic signals that accounts for differences in local frames (regardless of how these differences were introduced, e.g. anatomical heterogeneity, use of different data capture modalities or joint axis approaches, intra- and inter-rater reliability, etc.), as evidenced by peak root-mean-square errors of 0.24° ± 0.17° and 0.03 mm ± 0.01 mm after its implementation. By using a self-contained optimisation approach to systematically re-align the position and orientation of reference frames, REFRAME allows researchers to better assess whether two kinematic signals represent fundamentally similar or different underlying knee motion. The openly available implementation of REFRAME could therefore allow the consistent interpretation and comparison of knee kinematic signals across trials, subjects, examiners, or even research institutes.


  • Open Access

    A Framework for Analytical Validation of Inertial-Sensor-Based Knee Kinematics Using a Six-Degrees-of-Freedom Joint Simulator

    by Ariana Ortigas Vásquez, Allan Maas, Renate List, Pascal Schütz, William R. Taylor, Thomas M. Grupp

    The success of kinematic analysis that relies on inertial measurement units (IMUs) heavily depends on the performance of the underlying algorithms. Quantifying the level of uncertainty associated with the models and approximations implemented within these algorithms, without the complication of soft-tissue artefact, is therefore critical. To this end, this study aimed to assess the rotational errors associated with controlled movements. Here, data of six total knee arthroplasty patients from a previously published fluoroscopy study were used to simulate realistic kinematics of daily activities using IMUs mounted to a six-degrees-of-freedom joint simulator. A model-based method involving extended Kalman filtering to derive rotational kinematics from inertial measurements was tested and compared against the ground truth simulator values. The algorithm demonstrated excellent accuracy (root-mean-square error ≤0.9°, maximum absolute error ≤3.2°) in estimating three-dimensional rotational knee kinematics during level walking. Although maximum absolute errors linked to stair descent and sit-to-stand-to-sit rose to 5.2° and 10.8°, respectively, root-mean-square errors peaked at 1.9° and 7.5°. This study hereby describes an accurate framework for evaluating the suitability of the underlying kinematic models and assumptions of an IMU-based motion analysis system, facilitating the future validation of analogous tools.


  • Open Access

    The Influence of Mathematical Definitions on Patellar Kinematics Representations

    by Adrian Sauer, Maeruan Kebbach, Allan Maas, William M. Mihalko, Thomas M. Grupp

    A correlation between patellar kinematics and anterior knee pain is widely accepted. However, there is no consensus on how they are connected or what profile of patellar kinematics would minimize anterior knee pain. Nevertheless, answering this question by merging existing studies is further complicated by the variety of ways to describe patellar kinematics. Therefore, this study describes the most frequently used conventions for defining patellar kinematics, focusing on the rotations. The similarities and differences between the Cardan sequences and angles calculated by projecting axes are analyzed. Additionally, a tool is provided to enable the conversion of kinematic data between definitions in different studies. The choice of convention has a considerable impact on the absolute values and the clinical characteristics of the patello-femoral angles. In fact, the angles that result from using different mathematical conventions to describe a given patello-femoral rotation from our analyses differ up to a Root Mean Squared Error of 111.49° for patellar flexion, 55.72° for patellar spin and 35.39° for patellar tilt. To compare clinical kinematic patello-femoral results, every dataset must follow the same convention. Furthermore, researchers should be aware of the used convention’s implications to ensure reproducibility when interpreting and comparing such data.


  • Open Access

    Towards a New, Pre-Clinical, Subject-Independent Test Model for Kinematic Analysis after Total Knee Arthroplasty—Influence of the Proximo-Distal Patella Position and Patellar Tendon Stiffness

    by Adrian Sauer, Allan Maas, Svenja Ottawa, Alexander Giurea, Thomas M. Grupp

    Although simulation models are heavily used in biomechanical research and testing of TKA implants, pre-clinical tools for a holistic estimation of implant performance under dynamic loading conditions are rare. The objective of this study was the development of an efficient pre-clinical test method for analyzing knee contact mechanics and kinematics based on a dynamic FE model and to evaluate the effects of the proximo-distal patella position and the patellar tendon stiffness on the patellar kinematics. A finite element-based workflow for knee prostheses designs was developed based on standardized in vivo load data, which included the tibial forces and moments. In a new research approach, the tibial forces are used as input for the model, whereas the tibial moments were used to validate the results. For the standardized sit down, stand up, and knee bend load cycles, the calculated tibial moments show only small deviations from the reference values—especially for high flexion angles. For the knee bend cycle, the maximum absolute value of patellar flexion decreases for higher patellar tendon stiffness and more distally placed patellar components. Therefore, patella-related clinical problems caused by patella baja may also arise if the patellar tendon is too weak for high tibiofemoral flexion angles.