ILIlkka Laakso

Ilkka Laakso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ilkka Laakso has a total of 264 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of neuronal activation thresholds for low-frequency electromagnetic exposure using morphologically realistic neuron models

    by Joaquín Gázquez, Carolina Camacho Cadena, Wenzhe He, Eikei Yamada, Carsten Alteköster, Florian Soyka, Ilkka Laakso, Akimasa Hirata, Wout Joseph, Thomas Tarnaud, et al.

    Objective. International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In these frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study aimed to evaluate LF EMF-induced neural activation using morphologically realistic neuron models representing all cortical layers. Approach. Twenty-five morphologically realistic neuron models were embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Main results. Excitation thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE International Committee on Electromagnetic Safety and International Commission on Non-Ionizing Radiation Protection. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. Significance. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based central nervous system activation models.

  • Open Access

    Evaluation of Neuronal Activation Thresholds for Low-Frequency Electromagnetic Exposure Using Morphologically Realistic Neuron Models

    by Joaquín Gázquez, Carolina Camacho Cadena, Wenzhe He, Eikei Yamada, Carsten Altekoester, Florian Soyka, Ilkka Laakso, Akimasa Hirata, Wout Joseph, Thomas Tarnaud, et al.

    International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In the frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study evaluates LF EMF-induced neural activation using 25 morphologically realistic neuron models spanning all cortical layers, embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE ICES and ICNIRP. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based CNS activation models.

  • Top Cited Papers
    Open Access

    Model Variability in Assessment of Human Exposure to Radiofrequency Fields

    by Akimasa Hirata, Ilkka Laakso, Francesca Apollonio, Sachiko Kodera, Yoshiki Kubota, Junqing Lan, Kun Li, Micaela Liberti, Dragan Poljak, Kensuke Sasaki, et al.

    The recent advances in computational dosimetry for electromagnetics and thermodynamics are reviewed to assess human exposure to electromagnetic fields in the MHz-to-terahertz range. This review emphasizes model variability in computational dosimetry. Apart from computational electromagnetic methods and their usage, the developments in anatomical phantoms and tissue dielectric properties characterization are also surveyed. In addition, the rationale for dosimetric quantities prescribed in international exposure guidelines, such as the specific absorption rate (SAR) and absorbed power density, is revisited in relation to their correlation with local and core temperature rises in various tissues and populations. A heating factor, which is defined as a steady-state temperature rise per SAR, for the brain, eye lens, skin, and body core is evaluated to estimate heating resulting from exposure to electromagnetic fields. The transition of a physical quantity in the guidelines at 6 GHz, from SAR to the absorbed power density, is discussed along with the optimal spatial averaging volume and areas. Computational evaluations of product compliance, 5G devices, and wireless power transfer systems are also reviewed. This review aims to synthesize the current knowledge, identify key sources of computational model variability and uncertainty, and outline further research needs for setting exposure guidelines and compliance assessment.


  • Open Access

    Optimal coil orientation in transcranial magnetic stimulation of the hand motor area: integration of experimental and computational analyses

    by Yosuke Nagata, Akimasa Hirata, Sachiko Kodera, Ilkka Laakso, Yoshikazu Ugawa

    Objective. This study aimed to determine the optimal coil orientation for transcranial magnetic stimulation (TMS) of the hand motor area by integrating physiological and computational approaches. Approach. Resting motor thresholds (RMTs) were measured in 10 healthy volunteers for the first dorsal interosseous (FDI) and abductor digiti minimi (ADM) muscles when stimulating the primary motor cortex (M1) with a coil set at several orientations ranging from 0° to 90°. Electric field (EF) distributions were estimated using individualized head models constructed from magnetic resonance imaging (MRI) data of the same 10 participants in the measurements, as well as additional 135 MRI-derived models. Simulations employed a scalar-potential finite-difference method to quantify the EF magnitude in the M1-hand region across orientations. Main results. The lowest RMTs were obtained between 30° and 45° for both muscles, and the optimal angle depended on the target muscle (44.3 ± 9.8° for FDI and 37.9 ± 10.3° for ADM). Calculated EF magnitudes correlated negatively with the measured RMT values. Analysis of the additional 135 MRI-derived head models showed that coil orientations of 30°–45° most frequently produced high EF, and this coil-angle dependence remained stable even when the coil position was slightly displaced. Anatomical analysis revealed that the cortical surface orientations in the M1-hand area were frequently 30°–45° to the parasagittal plane. Significance. These findings support the current guidelines’ recommendation of a ∼45° orientation, but suggest that a 30°–45° range better aligns EF with cortical geometry. Individualized optimization can further improve the precision and efficacy of TMS.


  • Open Access

    Distinct cortical excitability and connectivity profiles within the human SMA complex

    by Francesco Lomi, Ali Jafarov, Fiammetta Iannuzzo, Timo Roine, Ida Granö, Juha Gogulski, Dogu Baran Aydogan, Ilkka Laakso, Mario Rosanova, Simone Rossi, et al.

    Introduction and aim: Understanding brain functions increasingly relies on a network-based perspective, emphasizing interactions across distributed regions. High-order cognitive functions, like language and executive processes, engage such networks rather than isolated cortical areas, yet mapping their dynamics in humans remains challenging. The supplementary motor area (SMA) complex serves as a crucial hub, functioning as an interface between cognitive and sensorimotor processing. Navigated transcranial magnetic stimulation combined with electroencephalography (TMS–EEG) enables causal, time-resolved assessment of cortical excitability and connectivity with high temporal and spatial precision. Extending prior proof-of-concept work, this study aims to provide normative neurophysiological signatures of the SMA complex (pre-SMA and SMA). Methods: Twenty-one healthy subjects underwent a TMS–EEG session where six stimulation targets over the SMA complex (three in pre-SMA, one in the border between pre-SMA and SMA, two in SMA) were recorded. Global cortical excitability via global mean field power (GMFP) was computed over three time-windows (10–50, 50–100, and 100–200 ms) and compared across targets. Normalized power in different frequency bands (α, β1, β2, γ) and natural frequency (NF) were also computed and compared across stimulation sites. Then, we calculated tractography-derived connectivity metrics to examine corticothalamic projections from each stimulation site. Apparent fiber density (AFD)-derived connection strength quantified intra-axonal fibre volume along pathways to the whole thalamus, whereas fibre bundle capacity (FBC) assessed the aggregate intra-axonal cross-sectional area at pathway endpoints, providing an estimate of information transmission capacity to each of the 23 thalamic nuclei. Results: Cortical excitability and oscillatory properties varied significantly across TMS targets. A gradient in cortical excitability was observed, where anterior and middle portions of pre-SMA exhibited significantly lower GMFP in the early post-stimulus phase (i.e., 10–50 ms) than SMA portions; interestingly, these differences were clearly dampened in a later time-window (50–100 ms) and disappeared after this period. Furthermore, higher α and lower β2 power were observed in anterior pre-SMA than posterior pre-SMA portions. No differences were observed in NF. Crucially, we also observed significant differences in whole- and single-nuclei thalamic structural connectivity. Discussion: These findings provide direct human in vivo evidence for distinct neurophysiological and structural connectivity profiles of the pre-SMA and SMA, possibly reflecting their different cytoarchitectonic, myeloarchitectonic and connectivity properties. Variations in cortical excitability, oscillatory dynamics, and FBC along the rostro-caudal axis may mirror functional specialization, with pre-SMA supporting cognitive control processes and SMA engaging motor-related thalamocortical networks. Together, the results demonstrate the sensitivity of TMS–EEG and diffusion-weighted connectomics to measure fine-grained neurophysiological differences of corticothalamic projections, which can lead to individualized neuromodulation targeting.


  • Open Access

    Roadmap towards personalized approaches and safety considerations in non-ionizing radiation: from dosimetry to therapeutic and diagnostic applications

    by Ilkka Laakso, Maarten M Paulides, Sachiko Kodera, Seungyoung Ahn, Christopher L Brace, Marta Cavagnaro, Ji Chen, Zhi-De Deng, Valerio De Santis, Yinliang Diao, et al.

    This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis.


  • Tensor-based SPFD method for accurate low-frequency magnetic field dosimetry in anatomical models

    by Eikei Yamada, Yinliang Diao, Ilkka Laakso, Akimasa Hirata

    Objective. Concerns regarding the potential adverse health effects of electromagnetic field exposure are increasing. At low frequencies, international guidelines have adopted the induced electric field within the human body as an index for safety assessment. However, because direct, non-invasive measurement of the induced field is not feasible, computational analysis using anatomically realistic human models is commonly employed. However, these models rely on tissue segmentation and are prone to numerical artifacts, particularly staircasing errors, at tissue interfaces with sharp conductivity contrast. To address this issue, we propose a novel three-dimensional scalar-potential finite-difference (SPFD) method that incorporates a tensor-conductance model and applies it to realistic human head models for the first time. Approach. We propose a three-dimensional SPFD method incorporating a tensor-conductance model, applied here for the first time to anatomically realistic human head models. The method was validated with multilayer spherical models and evaluated under uniform magnetic field exposure and transcranial magnetic stimulation (TMS). Main Results. In spherical models, the proposed method reduced root-mean-square error by up to 65% and improved agreement with theoretical values compared to the conventional method. In head models, it consistently suppressed numerical artifacts and reduced maximum electric field values by up to 22% under uniform exposure and by 5%–8% under TMS. Computational efficiency was improved using a multigrid method, achieving a 25-fold speedup without compromising accuracy. Significance. The tensor-based 3D SPFD method significantly improves field estimation accuracy while reducing computational artifacts in complex anatomical models. This approach may contribute to refining exposure limits and enhancing simulation fidelity for medical applications.


  • Open Access

    Roadmap towards Personalized Approaches and Safety Considerations in Non-Ionizing Radiation: From Dosimetry to Therapeutic and Diagnostic Applications

    by Ilkka Laakso, Margarethus Marius Paulides, Sachiko Kodera, Seungyoung Ahn, Christopher L. Brace, Marta Cavagnaro, Ji Chen, Zhi-De Deng, Valerio De Santis, Yinliang Diao, et al.

    This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis.


  • Open Access

    Alvar whole-body model: impact of muscle anisotropy on computational dosimetry

    by Otto Kangasmaa, Tuukka Lehtinen, Ilkka Laakso

    Objective. Computational electromagnetic dosimetry relies on accurate whole-body models to assess human exposure to electromagnetic fields. However, existing models lack anisotropic properties of tissues. This work addresses these limitations by introducing a whole-body model, Alvar, containing fully anisotropic skeletal muscles. Approach. The Alvar model has been constructed based on an anatomic atlas and developed specifically for computational dosimetry. Anisotropic models of skeletal muscles were created using Laplacian vector field simulations. Computational dosimetry was performed using anisotropic and isotropic versions of Alvar and six existing isotropic body models to estimate the electric fields induced due to exposure to spatially uniform magnetic and electric fields at 50 Hz. Main results. Modelling skeletal muscle anisotropy resulted in small variations in the 99th percentile induced electric field values (±5%) when the Alvar model was exposed to a magnetic field. When exposed to an external electric field, using anisotropic muscles systematically decreased the 99th percentile values by 13%. However, local differences in the induced electric field were larger (26%–29%) and even more significant inside muscle tissue (35%–39%). Significance. The results show that isotropic models are sufficient for calculating 99th percentile values when assessing whole-body exposure at power line frequencies but can lead to errors in local electric fields, especially in muscle tissue. This research contributes to the characterisation of uncertainty in low-frequency electromagnetic dosimetry, which can inform the development of human exposure limits.