Daniel Louis Polders
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Louis Polders has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Peter R. Luijten
3 shared publications- Alexander Leemans
Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
2 shared publications Jeroen Hendrikse
Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publications- Alexander Jan Eberhard Raaijmakers
Department of Radiology University Medical Center Utrecht Utrecht the Netherlands
1 shared publication - Astrid L. H. M. W. van Lier
Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584CX Utrecht, Netherlands
1 shared publication - Craig K. Jones
Department of Computer Science, Johns Hopkins University, Baltimore, USA
1 shared publication
Latest Publications
- Open Access
- 5 March 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (1) , 381-389
Local specific absorption rate in brain tumors at 7 tesla
Purpose MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in patients who have large lesions with potentially abnormal dielectric properties, e.g., brain tumors. Theory and Methods In this study, brain tumor patient models are constructed based on scans of four patients with high grade brain tumors. Dielectric properties for the modeled tumors are assigned based on electrical properties tomography data for the same patients. Simulations were performed to determine SAR. Results Local SAR increases in the tumors by as much as 30%. However, the location of the maximum 10-gram averaged SAR typically occurs outside of the tumor, and thus does not increase. In the worst case, if the tumor model is moved to the location of maximum electric field intensity, then we do observe an increase in the estimated peak 10-gram SAR directly related to the tumor. Conclusion Peak local SAR estimation made on the results of a healthy patient model simulation may underestimate the true peak local SAR in a brain tumor patient. Magn Reson Med 75:381–389, 2016.
- 5 March 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (1) , 381-389
Open AccessLocal specific absorption rate in brain tumors at 7 tesla
Purpose MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in patients who have large lesions with potentially abnormal dielectric properties, e.g., brain tumors. Theory and Methods In this study, brain tumor patient models are constructed based on scans of four patients with high grade brain tumors. Dielectric properties for the modeled tumors are assigned based on electrical properties tomography data for the same patients. Simulations were performed to determine SAR. Results Local SAR increases in the tumors by as much as 30%. However, the location of the maximum 10-gram averaged SAR typically occurs outside of the tumor, and thus does not increase. In the worst case, if the tumor model is moved to the location of maximum electric field intensity, then we do observe an increase in the estimated peak 10-gram SAR directly related to the tumor. Conclusion Peak local SAR estimation made on the results of a healthy patient model simulation may underestimate the true peak local SAR in a brain tumor patient. Magn Reson Med 75:381–389, 2016.
- 1 July 2013
- Published by Elsevier in PET Clinics
- Vol. 8 (3) , 245-257
Chemical Exchange Saturation Transfer MR Imaging
- 1 July 2013
- Published by Elsevier in PET Clinics
- Vol. 8 (3) , 245-257
Chemical Exchange Saturation Transfer MR Imaging
- 1 November 2012
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 224, 53-60
Uncertainty estimations for quantitative in vivo MRI T1 mapping
- 1 November 2012
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 224, 53-60
Uncertainty estimations for quantitative in vivo MRI T1 mapping
- Open Access
- 14 November 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (6) , 1579-1589
In vivo three‐dimensional whole‐brain pulsed steady‐state chemical exchange saturation transfer at 7 T
Chemical exchange saturation transfer (CEST) is a technique to indirectly detect pools of exchangeable protons through the water signal. To increase its applicability to human studies, it is needed to develop sensitive pulse sequences for rapidly acquiring whole‐organ images while adhering to stringent amplifier duty cycle limitations and specific absorption rate restrictions. In addition, the interfering effects of direct water saturation and conventional magnetization transfer contrast complicate CEST quantification and need to be reduced as much as possible. It is shown that for protons exchanging with rates of less than 50–100 Hz, such as imaged in amide proton transfer experiments, these problems can be addressed by using a three‐dimensional steady state pulsed acquisition of limited B1 strength (∼1 μT). Such an approach exploits the fact that the direct water saturation width, magnetization transfer contrast magnitude, and specific absorption rate increase strongly with B1, while the size of the CEST effect for such protons depends minimally on B1. A short repetition time (65 ms) steady‐state sequence consisting of a brief saturation pulse (25 ms) and a segmented echo‐planar imaging train allowed acquisition of a three‐dimensional whole‐brain volume in approximately 11 s per saturation frequency, while remaining well within specific absorption rate and duty cycle limits. Magnetization transfer contrast was strongly reduced, but substantial saturation effects were found at frequencies upfield from water, which still confound the use of magnetization transfer asymmetry analysis. Fortunately, the limited width of the direct water saturation signal could be exploited to fit it with a Lorentzian function allowing CEST quantification. Amide proton transfer effects ranged between 1.5% and 2.5% in selected white and grey matter regions. This power and time‐efficient 3D pulsed CEST acquisition scheme should aid endogenous CEST quantification at both high and low fields. Magn Reson Med, 2011.
- 14 November 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (6) , 1579-1589
Open AccessIn vivo three‐dimensional whole‐brain pulsed steady‐state chemical exchange saturation transfer at 7 T
Chemical exchange saturation transfer (CEST) is a technique to indirectly detect pools of exchangeable protons through the water signal. To increase its applicability to human studies, it is needed to develop sensitive pulse sequences for rapidly acquiring whole‐organ images while adhering to stringent amplifier duty cycle limitations and specific absorption rate restrictions. In addition, the interfering effects of direct water saturation and conventional magnetization transfer contrast complicate CEST quantification and need to be reduced as much as possible. It is shown that for protons exchanging with rates of less than 50–100 Hz, such as imaged in amide proton transfer experiments, these problems can be addressed by using a three‐dimensional steady state pulsed acquisition of limited B1 strength (∼1 μT). Such an approach exploits the fact that the direct water saturation width, magnetization transfer contrast magnitude, and specific absorption rate increase strongly with B1, while the size of the CEST effect for such protons depends minimally on B1. A short repetition time (65 ms) steady‐state sequence consisting of a brief saturation pulse (25 ms) and a segmented echo‐planar imaging train allowed acquisition of a three‐dimensional whole‐brain volume in approximately 11 s per saturation frequency, while remaining well within specific absorption rate and duty cycle limits. Magnetization transfer contrast was strongly reduced, but substantial saturation effects were found at frequencies upfield from water, which still confound the use of magnetization transfer asymmetry analysis. Fortunately, the limited width of the direct water saturation signal could be exploited to fit it with a Lorentzian function allowing CEST quantification. Amide proton transfer effects ranged between 1.5% and 2.5% in selected white and grey matter regions. This power and time‐efficient 3D pulsed CEST acquisition scheme should aid endogenous CEST quantification at both high and low fields. Magn Reson Med, 2011.
- Open Access
- 17 May 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (6) , 1456-1463
Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
Purpose: To compare diffusion tensor imaging (DTI) measurements at ultra high field strength (7 Tesla [T]) in human volunteers with DTI measurements performed at 1.5 and 3 Tesla.Materials and Methods: The signal to noise ratio (SNR) and the uncertainty in fitted DTI parameters fractional anisotropy and primary eigenvector are assessed with tractography based regions of interest, measured in nine volunteers at 1.5T, 3T, and 7T with clinically available hardware configurations.Results: An increase in SNR is observed on the 7T system compared with the 1.5 or 3T system. The measured increase in SNR at 7T is larger than expected from field strength alone, indicating the large influence of improved receive coil hardware. Additionally, while the average fractional anisotropy remains relatively constant across field strengths, a decrease in uncertainty in the fitted values for fractional anisotropy and the principal eigenvector of the DTI tensor was found. Increased spatial heterogeneity of signal intensities is observed at 7T.Conclusion: Given the current hardware constraints, DTI at ultra‐high field strengths is possible with improved performance in selected regions of interest. J. Magn. Reson. Imaging 2011;33:1456–1463.
- 17 May 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (6) , 1456-1463
Open AccessSignal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
Purpose: To compare diffusion tensor imaging (DTI) measurements at ultra high field strength (7 Tesla [T]) in human volunteers with DTI measurements performed at 1.5 and 3 Tesla.Materials and Methods: The signal to noise ratio (SNR) and the uncertainty in fitted DTI parameters fractional anisotropy and primary eigenvector are assessed with tractography based regions of interest, measured in nine volunteers at 1.5T, 3T, and 7T with clinically available hardware configurations.Results: An increase in SNR is observed on the 7T system compared with the 1.5 or 3T system. The measured increase in SNR at 7T is larger than expected from field strength alone, indicating the large influence of improved receive coil hardware. Additionally, while the average fractional anisotropy remains relatively constant across field strengths, a decrease in uncertainty in the fitted values for fractional anisotropy and the principal eigenvector of the DTI tensor was found. Increased spatial heterogeneity of signal intensities is observed at 7T.Conclusion: Given the current hardware constraints, DTI at ultra‐high field strengths is possible with improved performance in selected regions of interest. J. Magn. Reson. Imaging 2011;33:1456–1463.
- Open Access
- 21 November 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (5) , 1221-1226
Diffusion-weighted MR neurography of the sacral plexus with unidirectional motion probing gradients
Background This technical note introduces diffusion-weighted (DW) MR neurography (MRN) of the sacral plexus with unidirectional motion probing gradients (MPGs). Methods This is compared with DW MRN with three-directional and six-directional MPGs. Results and conclusion This paper indicates that DW MRN of the sacral plexus should be performed with unidirectional MPGs.
- 21 November 2009
- Published by Springer Nature in European Radiology
- Vol. 20 (5) , 1221-1226
Open AccessDiffusion-weighted MR neurography of the sacral plexus with unidirectional motion probing gradients
Background This technical note introduces diffusion-weighted (DW) MR neurography (MRN) of the sacral plexus with unidirectional motion probing gradients (MPGs). Methods This is compared with DW MRN with three-directional and six-directional MPGs. Results and conclusion This paper indicates that DW MRN of the sacral plexus should be performed with unidirectional MPGs.
- 1 September 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 188 (1) , 10-23
A novel improved method for analysis of 2D diffusion–relaxation data—2D PARAFAC-Laplace decomposition
- 1 September 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 188 (1) , 10-23
A novel improved method for analysis of 2D diffusion–relaxation data—2D PARAFAC-Laplace decomposition