THTaras Hanulia

Taras Hanulia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Taras Hanulia has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep learning-enabled detection of rare circulating tumor cell clusters in whole blood using label-free, flow cytometry

    by Nilay Vora, Prashant Shekar, Taras Hanulia, Michael Esmail, Abani Patra, Irene Georgakoudi

    We present a deep-learning enabled, label-free flow cytometry platform for identifying circulating tumor cell clusters in whole blood based on the endogenous scattering detected at three wavelengths. The method has potential for in vivo translation.


  • Open Access

    Enhanced DNA Raman modes probed by SiO2 photonic crystals

    by M. Olenchuk, T. Hanulia, A. Nikolenko, G. Dovbeshko

    The study of large biomolecules, in particular DNA, is of practical interest. Marker bands of the Raman spectrum of DNA provide information about the conformational state and structure of the macromolecule. At the same time, when dealing with biological experiments, a small amount of DNA is available, which is why it is important to enhance the signal from DNA and find the proper substrate. However, it is difficult to enhance Raman spectra for large molecules as DNA without functionalization that could introduce changes in the DNA structure. In this work, a conventional substrate as CaF2 and a photonic crystal as a substrate with enhancer signal property and without DNA functionalization were applied. The factor of enhancement for DNA from salmon testes was reached up to 10 without Raman spectra distortion. The Raman spectral bands on different types of substrates are analyzed and compared.

  • Laser induced visible and infrared emission of a tungsten filament

    by Wieslaw Strek, Mariusz Stefanski, Taras Hanulia, Robert Tomala, Przemyslaw Wiewiorski

    The measurements of laser induced emission (LIE) of a tungsten filament upon irradiation with the focused beam of a CW IR laser diode are reported. It was found that the emission occurred in visible and infrared range. The influence of the applied DC electric field significantly affected the intensity of LIE of the tungsten filament. The origin of LIE is discussed in terms of multiphoton ionization of tungsten W+ atoms assisted by light emission due to the intervalence charge transfer in the tungsten hybrid domain (W, W+).


  • Open Access

    Investigation of coherence properties of white light emission of tungsten lamp additionally excited with laser radiation

    by T. Hanulia, M. Oleszko, R. Tomala, W. Strek

    The coherence properties of white light emission of a tungsten incandescent lamp additionally excited with laser radiation are investigated. The degree of spatial coherence is determined from measurements of the contrast of interference fringe patterns obtained for a tungsten bulb as the light source. It is demonstrated that the degree of spatial coherence of an incandescent lamp is increased by additional excitation of the filament with focused laser radiation. Furthermore, the degree of spatial coherence can be adjusted by selecting the voltage applied to the filament. Such light sources can find applications in imaging techniques where precise control of spatial coherence of illumination is required.


  • Open Access

    Coherent white emission of graphene

    by W. Strek, M. Oleszko, P. Wiewiórski, R. Tomala, T. Hanulia

    The coherence properties of broadband white light emitted by graphene foam after irradiation with intense light of laser diodes were investigated. The interference fringes assigned to spatial and temporal coherence were observed for graphene white-light emission excited by two different excitation wavelengths of 975 nm and 808 nm of laser diodes. Both light sources were spectrally filtered to a narrow bandwidth in order to exclude the effect of temporal coherence. It was found that the coherence degree of white light emission of graphene differs depending on the excitation wavelength; however, no excitation power effect on the coherence degree was observed. The origin of coherence of laser-induced white emission of graphene is the stimulated emission due to the inversion population.


  • Fluorescence lifetime measurement excited with ultraviolet surface plasmon resonance

    by Taras Hanulia, Wataru Inami, Atsushi Ono, Yoshimasa Kawata


  • Aluminum Film Thickness Dependence of Surface Plasmon Resonance in the Far- and Deep-ultraviolet Regions

    by Ichiro Tanabe, Yoshito Y. Tanaka, Koji Watari, Taras Hanulia, Takeyoshi Goto, Wataru Inami, Yoshimasa Kawata, Yukihiro Ozaki

    Aluminum film thickness dependence of surface plasmon resonance (SPR) in the far- and deep-ultraviolet regions (170–300 nm) was revealed using an attenuated total reflectance spectrometer. In the far-ultraviolet region (<200 nm), films of thicknesses 23 and 9 nm showed strong SPR excitations in air and 1,1,1,3,3,3-hexafluoro-2-propanol, which were reproduced by simulations based on the Fresnel equations, respectively. Therefore, Al-SPR sensors are expected to work both in air and in liquids by controlling the film thickness.


  • Open Access

    Far- and deep-ultraviolet surface plasmon resonance sensors working in aqueous solutions using aluminum thin films

    by Ichiro Tanabe, Yoshito Y. Tanaka, Koji Watari, Taras Hanulia, Takeyoshi Goto, Wataru Inami, Yoshimasa Kawata, Yukihiro Ozaki

    Surface plasmon resonance (SPR) sensors detect refractive index changes on metal thin films and are frequently used in aqueous solutions as bio- and chemical-sensors. Recently, we proposed new SPR sensors using aluminum (Al) thin films that work in the far- and deep-ultraviolet (FUV-DUV, 120–300 nm) regions and investigated SPR properties by an attenuated total reflectance (ATR) based spectrometer. The FUV-DUV-SPR sensors are expected to have three advantages compared to visible-SPR sensors: higher sensitivity, material selectivity, and surface specificity. However, in this study, it was revealed that the Al thin film on a quartz prism cannot be used as the FUV-DUV-SPR sensor in water solutions. This is because its SPR wavelength shifts to the visible region owing to the presence of water. On the other hand, the SPR wavelength of the Al thin film on the sapphire prism remained in the DUV region even in water. In addition, the SPR wavelength shifted to longer wavelengths with increasing refractive index on the Al thin film. These results mean that the Al thin film on the sapphire prism can be used as the FUV-DUV-SPR sensor in solutions, which may lead to the development of novel and sophisticated SPR sensors.


  • Deposition condition influence on optical properties of indium tin oxide

    by Taras O. Hanulia, Olga Lopatynska, Vasyl V. Lendel, Leonid V. Poperenko

    Indium tin oxide (ITO) is a solid solution of indium (III) oxide (In2O3) and tin (IV) oxide (SnO2). It is a typical object for research in modern optoelectronics. This material combines high transparency (in the visible) and conductivity simultaneously. It is used in the production of transparent electrodes of liquid crystal screens and solar cells. The optical properties of thin films of ITO were investigated using ellipsometry. Optical constants of these films were calculated using obtained ellipsometric parameters. Films thicknesses are equal to 21-34 nm, and their refractive indices vary in interval of 2,05-2,12. Also, it was found out how the deposition conditions of ITO films influences their optical properties.

  • Angular and azimuthal ellipsometry of indium tin oxide films

    by Taras O. Hanulia, Olga Lopatynska, Vasyl V. Lendel, Leonid V. Poperenko

    We investigated the optical properties of indium tin oxide thin (ITO) films, produced by reactive magnetron sputtering. Ellipsometric parameters were determined by laser ellipsometer. The refractive index and thickness of ITO films were calculated.