Jakub Kletecka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jakub Kletecka has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Jan Benes
Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine in Plzen, Charles University, Plzen, Czech Republic -
8 shared publications - Jan Zatloukal
Department of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine in Pilsen, University Hospital Plzeň and Charles University, Plzeň-Lochotín, Czech Republic
4 shared publications Jan Zatloukal
Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
3 shared publications- Richard Pradl
Department of Anesthesiology and Intensive Care, Pilsen University Hospital, Faculty of Medicine, Charles University Prague, Pilsen, Czech Republic
3 shared publications Irena Holeckova
Department of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital Pilsen - Pilsen, Czech Republic
2 shared publications- Ivan Chytra
Department of Anaesthesiology and Intensive Care, The University Hospital and The Faculty of Medicine in Plzen - Charles University, Alej Svobody 80, 304 60, Plzen, Czech Republic
2 shared publications
Latest Publications
- 14 December 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (4) , 1533-1544
Influence of an EDTA-based catheter lock solution on blood discard volume in PICC
Background: Vascular access devices (VADs) are increasingly used for blood sampling, yet optimal discard volumes remain uncertain, particularly when EDTA-based lock solutions are used. Objective: To evaluate whether discarding 1 mL is sufficient for reliable laboratory testing after use of 4% tetrasodium EDTA catheter lock solution (Kitelock™) in PICC. Methods: In a prospective study, 10 patients with single-lumen peripherally inserted central catheters (polyurethane, 4F, open-ended) underwent blood sampling after flushing the catheter and discarding 1 mL, corresponding to approximately two dead spaces for the shortened catheters used. Five consecutive tubes were analyzed per sample type (biochemistry, hematology, coagulation). Agreement with the reference tube (tube 5) was assessed using Bland–Altman plots, clinically acceptable intervals (CAI), intraclass correlation coefficient (ICC), and Lin’s concordance correlation coefficient (CCC). Results: In the first tube, several analytes reached 10/10 comparisons within the CAI (urea, sodium, potassium, calcium, magnesium, alkaline phosphatase, erythrocytes, hematocrit, MCV, leucocytes, thrombin time). Others showed 9/10 comparisons (total protein, albumin, chloride, hemoglobin, thrombocytes, APTT, prothrombin time, fibrinogen). Only creatinine reached 8/10. Conclusions: Discarding 1 mL appeared sufficient for reliable testing after Kitelock™ use in our cohort, but confirmation in larger studies is warranted.
- 14 December 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (4) , 1533-1544
Influence of an EDTA-based catheter lock solution on blood discard volume in PICC
Background: Vascular access devices (VADs) are increasingly used for blood sampling, yet optimal discard volumes remain uncertain, particularly when EDTA-based lock solutions are used. Objective: To evaluate whether discarding 1 mL is sufficient for reliable laboratory testing after use of 4% tetrasodium EDTA catheter lock solution (Kitelock™) in PICC. Methods: In a prospective study, 10 patients with single-lumen peripherally inserted central catheters (polyurethane, 4F, open-ended) underwent blood sampling after flushing the catheter and discarding 1 mL, corresponding to approximately two dead spaces for the shortened catheters used. Five consecutive tubes were analyzed per sample type (biochemistry, hematology, coagulation). Agreement with the reference tube (tube 5) was assessed using Bland–Altman plots, clinically acceptable intervals (CAI), intraclass correlation coefficient (ICC), and Lin’s concordance correlation coefficient (CCC). Results: In the first tube, several analytes reached 10/10 comparisons within the CAI (urea, sodium, potassium, calcium, magnesium, alkaline phosphatase, erythrocytes, hematocrit, MCV, leucocytes, thrombin time). Others showed 9/10 comparisons (total protein, albumin, chloride, hemoglobin, thrombocytes, APTT, prothrombin time, fibrinogen). Only creatinine reached 8/10. Conclusions: Discarding 1 mL appeared sufficient for reliable testing after Kitelock™ use in our cohort, but confirmation in larger studies is warranted.
- 29 November 2023
- Published by Springer Nature
- p. 117-122
Herpesviridae. A Young Man with Acute Liver Failure and Hemolysis
- 29 November 2023
- Published by Springer Nature
- p. 117-122
Herpesviridae. A Young Man with Acute Liver Failure and Hemolysis
- Open Access
- 8 March 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (3) , 486
Individualizing Fluid Management in Patients with Acute Respiratory Distress Syndrome and with Reduced Lung Tissue Due to Surgery—A Narrative Review
Fluids are the cornerstone of therapy in all critically ill patients. During the last decades, we have made many steps to get fluid therapy personalized and based on individual needs. In patients with lung involvement—acute respiratory distress syndrome—finding the right amount of fluids after lung surgery may be extremely important because lung tissue is one of the most vulnerable to fluid accumulation. In the current narrative review, we focus on the actual perspectives of fluid therapy with the aim of showing the possibilities to tailor the treatment to a patient’s individual needs using fluid responsiveness parameters and other therapeutic modalities.
- 8 March 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (3) , 486
Open AccessIndividualizing Fluid Management in Patients with Acute Respiratory Distress Syndrome and with Reduced Lung Tissue Due to Surgery—A Narrative Review
Fluids are the cornerstone of therapy in all critically ill patients. During the last decades, we have made many steps to get fluid therapy personalized and based on individual needs. In patients with lung involvement—acute respiratory distress syndrome—finding the right amount of fluids after lung surgery may be extremely important because lung tissue is one of the most vulnerable to fluid accumulation. In the current narrative review, we focus on the actual perspectives of fluid therapy with the aim of showing the possibilities to tailor the treatment to a patient’s individual needs using fluid responsiveness parameters and other therapeutic modalities.
- Open Access
- 1 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
SepsEast Registry indicates high mortality associated with COVID-19 caused acute respiratory failure in Central-Eastern European intensive care units
The coronavirus disease (COVID-19) pandemic caused unprecedented research activity all around the world but publications from Central-Eastern European countries remain scarce. Therefore, our aim was to characterise the features of the pandemic in the intensive care units (ICUs) among members of the SepsEast (Central-Eastern European Sepsis Forum) initiative. We conducted a retrospective, international, multicentre study between March 2020 and February 2021. All adult patients admitted to the ICU with pneumonia caused by COVID-19 were enrolled. Data on baseline and treatment characteristics, organ support and mortality were collected. Eleven centres from six countries provided data from 2139 patients. Patient characteristics were: median 68, [IQR 60–75] years of age; males: 67%; body mass index: 30.1 [27.0–34.7]; and 88% comorbidities. Overall mortality was 55%, which increased from 2020 to 2021 (p = 0.004). The major causes of death were respiratory (37%), cardiovascular (26%) and sepsis with multiorgan failure (21%). 1061 patients received invasive mechanical ventilation (mortality: 66%) without extracorporeal membrane oxygenation (n = 54). The rest of the patients received non-invasive ventilation (n = 129), high flow nasal oxygen (n = 317), conventional oxygen therapy (n = 122), as the highest level of ventilatory support, with mortality of 50%, 39% and 22%, respectively. This is the largest COVID-19 dataset from Central-Eastern European ICUs to date. The high mortality observed especially in those receiving invasive mechanical ventilation renders the need of establishing national–international ICU registries and audits in the region that could provide high quality, transparent data, not only during the pandemic, but also on a regular basis.
- 1 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Open AccessSepsEast Registry indicates high mortality associated with COVID-19 caused acute respiratory failure in Central-Eastern European intensive care units
The coronavirus disease (COVID-19) pandemic caused unprecedented research activity all around the world but publications from Central-Eastern European countries remain scarce. Therefore, our aim was to characterise the features of the pandemic in the intensive care units (ICUs) among members of the SepsEast (Central-Eastern European Sepsis Forum) initiative. We conducted a retrospective, international, multicentre study between March 2020 and February 2021. All adult patients admitted to the ICU with pneumonia caused by COVID-19 were enrolled. Data on baseline and treatment characteristics, organ support and mortality were collected. Eleven centres from six countries provided data from 2139 patients. Patient characteristics were: median 68, [IQR 60–75] years of age; males: 67%; body mass index: 30.1 [27.0–34.7]; and 88% comorbidities. Overall mortality was 55%, which increased from 2020 to 2021 (p = 0.004). The major causes of death were respiratory (37%), cardiovascular (26%) and sepsis with multiorgan failure (21%). 1061 patients received invasive mechanical ventilation (mortality: 66%) without extracorporeal membrane oxygenation (n = 54). The rest of the patients received non-invasive ventilation (n = 129), high flow nasal oxygen (n = 317), conventional oxygen therapy (n = 122), as the highest level of ventilatory support, with mortality of 50%, 39% and 22%, respectively. This is the largest COVID-19 dataset from Central-Eastern European ICUs to date. The high mortality observed especially in those receiving invasive mechanical ventilation renders the need of establishing national–international ICU registries and audits in the region that could provide high quality, transparent data, not only during the pandemic, but also on a regular basis.
- 29 April 2019
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part A: Central European Neurosurgery
- Vol. 80 (05) , 341-344
Patient Satisfaction with General versus Local Anesthesia during Carotid Endarterectomy
Background and Study Aims Both general and local anesthesia are used in our department for carotid endarterectomy (CEA). The decision as to which anesthetic technique to use during surgery is made individually. The aim of our study was to evaluate patient satisfaction and preference with the anesthesia type used. Material and Methods The satisfaction of a group of 205 patients with regard to anesthesia used and their future preferences were evaluated prospectively through a questionnaire. The reasons for dissatisfaction were assessed. Results CEA was performed under general anesthesia (GA) in 159 cases (77.6%) and under local anesthesia (LA) in 46 cases (22.4%). In the GA group, 148 patients (93.1%) were satisfied; 30 patients (65.2%) in the LA group were satisfied (p < 0.0001). The reason for dissatisfaction with GA were postoperative nausea and vomiting (7 patients), postoperative psychological alteration (3), and fear of GA (1). The reasons for dissatisfaction with LA were intraoperative pain (9 patients), intraoperative discomfort and stress (5), and intraoperative breathing problems (2). Of the GA group, 154 (96.9%) patients would prefer GA again, and of the LA group, 28 (60.9%) patients would prefer LA if operated on again (p < 0.0001). Overall, 172 patients (83.9%) would prefer GA in the future, and 33 patients (16.1%) would prefer LA. Conclusion Overall patient satisfaction with CEA performed under both GA and LA is high. Nevertheless, in the GA group, patient satisfaction and future preference were significantly higher. Both GA and LA have advantages and disadvantages for CEA. An optimal approach is to make use of both anesthetic techniques based on their individual indications and patient preference.
- 29 April 2019
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part A: Central European Neurosurgery
- Vol. 80 (05) , 341-344
Patient Satisfaction with General versus Local Anesthesia during Carotid Endarterectomy
Background and Study Aims Both general and local anesthesia are used in our department for carotid endarterectomy (CEA). The decision as to which anesthetic technique to use during surgery is made individually. The aim of our study was to evaluate patient satisfaction and preference with the anesthesia type used. Material and Methods The satisfaction of a group of 205 patients with regard to anesthesia used and their future preferences were evaluated prospectively through a questionnaire. The reasons for dissatisfaction were assessed. Results CEA was performed under general anesthesia (GA) in 159 cases (77.6%) and under local anesthesia (LA) in 46 cases (22.4%). In the GA group, 148 patients (93.1%) were satisfied; 30 patients (65.2%) in the LA group were satisfied (p < 0.0001). The reason for dissatisfaction with GA were postoperative nausea and vomiting (7 patients), postoperative psychological alteration (3), and fear of GA (1). The reasons for dissatisfaction with LA were intraoperative pain (9 patients), intraoperative discomfort and stress (5), and intraoperative breathing problems (2). Of the GA group, 154 (96.9%) patients would prefer GA again, and of the LA group, 28 (60.9%) patients would prefer LA if operated on again (p < 0.0001). Overall, 172 patients (83.9%) would prefer GA in the future, and 33 patients (16.1%) would prefer LA. Conclusion Overall patient satisfaction with CEA performed under both GA and LA is high. Nevertheless, in the GA group, patient satisfaction and future preference were significantly higher. Both GA and LA have advantages and disadvantages for CEA. An optimal approach is to make use of both anesthetic techniques based on their individual indications and patient preference.
- 18 March 2019
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part A: Central European Neurosurgery
- Vol. 80 (04) , 250-254
Indications for General versus Local Anesthesia during Carotid Endarterectomy
Background and Study Aims Both general anesthesia (GA) and local anesthesia (LA) are used in our department for carotid endarterectomy. The decision of which anesthetic technique to use during surgery is made on an individual basis. The aim of our study was to analyze the reasons for using GA or LA. Material and Methods The reasons that led to the selection of either GA or LA were analyzed retrospectively in a group of 409 patients. Results GA was used in 304 patients (74%) and LA in 105 patients (26%). The reasons for a preference for GA were clopidogrel use (88 patients), patient preference (80), increased risk of shunt insertion (43), unfavorable anatomical conditions (41), surgeon preference (21), simultaneous carotid endarterectomy and cardiac surgery (18), emergent carotid endarterectomy (12), and sleep apnea syndrome (1). The reasons for selecting LA were internal comorbidities (46 patients), patient preference (39), unavailability of intraoperative electrophysiologic monitoring (15), and pacemaker (5). Conclusion GA is the dominant choice for carotid endarterectomy in our department because of its prevailing benefits and its preference among neurosurgeons and patients. However, in some subgroups of patients, LA is preferable. An optimal approach is therefore an individual indication for both anesthesia techniques.
- 18 March 2019
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part A: Central European Neurosurgery
- Vol. 80 (04) , 250-254
Indications for General versus Local Anesthesia during Carotid Endarterectomy
Background and Study Aims Both general anesthesia (GA) and local anesthesia (LA) are used in our department for carotid endarterectomy. The decision of which anesthetic technique to use during surgery is made on an individual basis. The aim of our study was to analyze the reasons for using GA or LA. Material and Methods The reasons that led to the selection of either GA or LA were analyzed retrospectively in a group of 409 patients. Results GA was used in 304 patients (74%) and LA in 105 patients (26%). The reasons for a preference for GA were clopidogrel use (88 patients), patient preference (80), increased risk of shunt insertion (43), unfavorable anatomical conditions (41), surgeon preference (21), simultaneous carotid endarterectomy and cardiac surgery (18), emergent carotid endarterectomy (12), and sleep apnea syndrome (1). The reasons for selecting LA were internal comorbidities (46 patients), patient preference (39), unavailability of intraoperative electrophysiologic monitoring (15), and pacemaker (5). Conclusion GA is the dominant choice for carotid endarterectomy in our department because of its prevailing benefits and its preference among neurosurgeons and patients. However, in some subgroups of patients, LA is preferable. An optimal approach is therefore an individual indication for both anesthesia techniques.
- 31 October 2018
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 33 (4) , 665-673
Propofol versus sevoflurane anaesthesia: effect on cognitive decline and event-related potentials
Postoperative cognitive dysfunction (POCD) is diagnosed in up to 30% patients after anaesthesia. The causative role of anaesthetic toxicity remains unclear. Using clinical tests, no clear-cut differences have been observed between anaesthetics so far. The aim of this trial was to compare the incidence of POCD diagnosed by a battery of neuropsychologic tests after propofol and sevoflurane anaesthesia. Secondary goal was to examine possible relationship between POCD positivity and changes in auditory event-related potentials (ERPs). Sixty patients undergoing lumbar discectomy were prospectively randomized to receive depth-controlled sevoflurane (SEVO) or propofol (PROP) based anaesthesia. The neuropsychological examination and auditory event-related potentials (N1, P3a and P3b components) recording was performed preoperatively and on days 1, 6 and 42 after surgery. POCD was defined as a decline of more than one standard deviation in three or more tests. In 43 patients (20 in PROP and 23 in SEVO group) all selected tests were performed and used for the evaluation. POCD was present in 48%/60%, 18%/20% and 17%/11% (SEVO/PROP) of patients on days 1, 6 and 42 after surgery, with no significant intergroup difference. Among neuropsychologic tests, the most significant decline was observed in Semantic Verbal Fluency and Letter-Number Sequencing Test scores, congruently in both groups on days 1 and 6, with full recovery on the last control. Transient deteriorations in other tests were observed as well. No association of POCD positivity and ERPs changes was found, although long-term modifications of P3a and P3b components were observed, mainly in SEVO group. In our study, sevoflurane and propofol anaesthesia was associated with the similar incidence of POCD. Cognitive decline, mainly affecting executive functions, was temporary in most of the patients. Prolonged ERPs alterations after the anaesthesia seem not to have any relationship with the impairment registered by the neuropsychological examination and may represent subclinical changes.
- 31 October 2018
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 33 (4) , 665-673
Propofol versus sevoflurane anaesthesia: effect on cognitive decline and event-related potentials
Postoperative cognitive dysfunction (POCD) is diagnosed in up to 30% patients after anaesthesia. The causative role of anaesthetic toxicity remains unclear. Using clinical tests, no clear-cut differences have been observed between anaesthetics so far. The aim of this trial was to compare the incidence of POCD diagnosed by a battery of neuropsychologic tests after propofol and sevoflurane anaesthesia. Secondary goal was to examine possible relationship between POCD positivity and changes in auditory event-related potentials (ERPs). Sixty patients undergoing lumbar discectomy were prospectively randomized to receive depth-controlled sevoflurane (SEVO) or propofol (PROP) based anaesthesia. The neuropsychological examination and auditory event-related potentials (N1, P3a and P3b components) recording was performed preoperatively and on days 1, 6 and 42 after surgery. POCD was defined as a decline of more than one standard deviation in three or more tests. In 43 patients (20 in PROP and 23 in SEVO group) all selected tests were performed and used for the evaluation. POCD was present in 48%/60%, 18%/20% and 17%/11% (SEVO/PROP) of patients on days 1, 6 and 42 after surgery, with no significant intergroup difference. Among neuropsychologic tests, the most significant decline was observed in Semantic Verbal Fluency and Letter-Number Sequencing Test scores, congruently in both groups on days 1 and 6, with full recovery on the last control. Transient deteriorations in other tests were observed as well. No association of POCD positivity and ERPs changes was found, although long-term modifications of P3a and P3b components were observed, mainly in SEVO group. In our study, sevoflurane and propofol anaesthesia was associated with the similar incidence of POCD. Cognitive decline, mainly affecting executive functions, was temporary in most of the patients. Prolonged ERPs alterations after the anaesthesia seem not to have any relationship with the impairment registered by the neuropsychological examination and may represent subclinical changes.
- 1 January 2018
- Published by Elsevier in Clinical Neurophysiology
- Vol. 129 (1) , 246-253
Cognitive impairment measured by event-related potentials during early and late postoperative period following intravenous or inhalation anaesthesia
- 1 January 2018
- Published by Elsevier in Clinical Neurophysiology
- Vol. 129 (1) , 246-253
Cognitive impairment measured by event-related potentials during early and late postoperative period following intravenous or inhalation anaesthesia
- 1 October 2017
- Published by Edizioni Minerva Medica in Minerva Anestesiologica
- Vol. 83 (10) , 1051-1060
Comparison of absolute fluid restriction versus relative volume redistribution strategy in low central venous pressure anesthesia in liver resection surgery: a randomized controlled trial
Article: Comparison of absolute fluid restriction versus relative volume redistribution strategy in low central venous pressure anesthesia in liver resection surgery: a randomized controlled trial - Minerva Anestesiologica 2017 October;83(10):1051-60 - Minerva Medica - Journals
- 1 October 2017
- Published by Edizioni Minerva Medica in Minerva Anestesiologica
- Vol. 83 (10) , 1051-1060
Comparison of absolute fluid restriction versus relative volume redistribution strategy in low central venous pressure anesthesia in liver resection surgery: a randomized controlled trial
Article: Comparison of absolute fluid restriction versus relative volume redistribution strategy in low central venous pressure anesthesia in liver resection surgery: a randomized controlled trial - Minerva Anestesiologica 2017 October;83(10):1051-60 - Minerva Medica - Journals
- 27 October 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (6) , 949-956
Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room
The laboratory analysis provides accurate, but time consuming hemoglobin level estimation especially in the emergency setting. The reliability of time-sparing point of care devices (POCT) remains uncertain. We tested two POCT devices accuracy (HemoCue®201+ and Gem®Premier™3000) in routine emergency department workflow. Blood samples taken from patients admitted to the emergency department were analyzed for hemoglobin concentration using a laboratory reference Beckman Coulter LH 750 (HBLAB), the HemoCue (HBHC) and the Gem Premier 3000 (HBGEM). Pairwise comparison for each device and HbLAB was performed using correlation and the Bland–Altman methods. The reliability of transfusion decision was assessed using three-zone error grid. A total of 292 measurements were performed in 99 patients. Mean hemoglobin level were 115 ± 33, 110 ± 28 and 111 ± 30 g/l for HbHC, HbGEM and HbLAB respectively. A significant correlation was observed for both devices: HbHC versus HbLAB (r2 = 0.93, p < 0.001) and HBGEM versus HBLAB (r2 = 0.86, p < 0.001). The Bland–Altman method revealed bias of −3.7 g/l (limits of agreement −20.9 to 13.5) for HBHC and HBLAB and 2.5 g/l (−18.6 to 23.5) for HBGEM and HBLAB, which significantly differed between POCT devices (p < 0.001). Using the error grid methodology: 94 or 91 % of values (HbHC and HbGEM) fell in the zone of acceptable difference (A), whereas 0 and 1 % (HbHC and HbGEM) were unacceptable (zone C). The absolute accuracy of tested POCT devices was low though reaching a high level of correlation with laboratory measurement. The results of the Morey´s error grid were unfavorable for both POCT devices.
- 27 October 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (6) , 949-956
Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room
The laboratory analysis provides accurate, but time consuming hemoglobin level estimation especially in the emergency setting. The reliability of time-sparing point of care devices (POCT) remains uncertain. We tested two POCT devices accuracy (HemoCue®201+ and Gem®Premier™3000) in routine emergency department workflow. Blood samples taken from patients admitted to the emergency department were analyzed for hemoglobin concentration using a laboratory reference Beckman Coulter LH 750 (HBLAB), the HemoCue (HBHC) and the Gem Premier 3000 (HBGEM). Pairwise comparison for each device and HbLAB was performed using correlation and the Bland–Altman methods. The reliability of transfusion decision was assessed using three-zone error grid. A total of 292 measurements were performed in 99 patients. Mean hemoglobin level were 115 ± 33, 110 ± 28 and 111 ± 30 g/l for HbHC, HbGEM and HbLAB respectively. A significant correlation was observed for both devices: HbHC versus HbLAB (r2 = 0.93, p < 0.001) and HBGEM versus HBLAB (r2 = 0.86, p < 0.001). The Bland–Altman method revealed bias of −3.7 g/l (limits of agreement −20.9 to 13.5) for HBHC and HBLAB and 2.5 g/l (−18.6 to 23.5) for HBGEM and HBLAB, which significantly differed between POCT devices (p < 0.001). Using the error grid methodology: 94 or 91 % of values (HbHC and HbGEM) fell in the zone of acceptable difference (A), whereas 0 and 1 % (HbHC and HbGEM) were unacceptable (zone C). The absolute accuracy of tested POCT devices was low though reaching a high level of correlation with laboratory measurement. The results of the Morey´s error grid were unfavorable for both POCT devices.