SDSteven Dirven

Steven Dirven

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven Dirven has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Stretchable Array of Electronic Receptors for Esophageal Swallowing Robot for Biomimetic Simulations of Bolus Transport

    by Sattar Din, Weiliang Xu, Leo K. Cheng, Steven Dirven

    This paper presents the design, fabrication, calibration, and implementation of a novel stretchable array of capacitive sensors that mimics human receptors for an esophageal swallowing robot. The array is used to measure deformation of the esophageal conduit wall and interaction between food bolus and the esophagus in the form of pressure and shear stress, which is a novel in vitro method of food bolus transport study. It is constructed from a thin sheet of copper-polyimide laminate via a cost effective fabrication process involving photolithography, wet etching, and laser engraving technique. Calibration is conducted individually on the pressure, shear, and strain sensor elements of the array. The pressure, shear, and strain sensors response exhibit an average hysteresis of 10.17%, 11.78%, and 26.37% caused by the soft silicon rubber encapsulation. Linear regression technique is used to determine the linear sensitivity transfer function for all the three sensors. The array is embedded beneath the surface of the esophageal conduit of the swallowing robot and a series of swallowing experiments are conducted. Three types of food bolus with a viscosity of 0.18, 0.62, and 1.55 Pa.s are prepared using a commercial food thickener. The swallowing robot generates a peristaltic wave of 60 mm wavefront length and 40 mm.s-1 wave speed to mimic the swallowing action seen in the human esophagus. Manometer measurements are taken alongside for validation. The pressure sensor records maximum pressures of 2.24 kPa, 3.17 kPa, and 7.74 kPa respectively for the three types of bolus during swallowing. By comparison, the maximum pressures recorded by the manometer are 1.68 kPa, 2.82 kPa, and 8.08 kPa. The shear sensor on the other hand records maximum shear values of -0.3 kPa, -0.35 kPa, and -0.37 kPa respectively for the three food bolus mixtures. This works proves that the novel stretchable array of capacitive sensors can be used to mimic mechanoreceptors for the esophageal swallowing robot, which significantly extends its capability to be used by food scientists as a platform for a new novel method of bolus transport study.


  • Biomimetic evaluation of bolus transit in modelled esophageal swallowing

    by Sattar Din, Peter Xu, Leo Cheng, Steven Dirven

    There are many commercially available rheometric instruments that link bolus formulation and flow characteristics to quantitative engineering metrics. However, the exploration of these relationships does not necessarily capture the macroscale of bolus transport or arguably the most important interaction: what pressure the alimentary tract imparts on a bolus during swallowing, and to what end is viscosity a good predictor of food bolus transit behaviour? In order to investigate this relationship, a biomimetic esophageal swallowing robot has been developed that can transport boluses in a continuous peristaltic manner. In swallowing, physical interactions between the food boluses and the esophageal wall are modulated based on the feedback from mechanoreceptors, which are pressure and strain sensitive. This work focuses on expanding the functionality of the esophageal swallowing robot by introducing sensing elements to mimic the mechanoreceptors of the esophagus. The sensors also function as built-in measurement probes to complement some of the clinical bolus transit evaluation instrumentations. This robot integrates the knowledge of the swallowing physiology into the scientific rheological evaluation instrumentation to help food scientists identify food attributes that have more clinical relevance to safe and efficient bolus transport.

  • Self morphing soft-robotic gripper for handling and manipulation of delicate produce in horticultural applications

    by Dean Venter, Steven Dirven

    The task of autonomously gripping delicate objects such as fresh produce remains a challenge even in modern robotics. Current robotics grippers are mostly made of mechanical linkages and actuators which follow very structured trajectories. As these exhibit little mechanical compliance they can readily apply too much pressure as a point load, leading to blemishing or bruising of produce (eg. kiwifruit). In order to overcome this, this paper proposes a soft-robotic approach, which has the ability to morph and conform around the grasped object. This increases the contact area between the object and the gripper, resulting in a more equal distribution of force, and a lower effective contact pressure. Additionally, this allows for a more secure grip to be achieved. The proposed gripper design is inspired by the soft-touch of the human hand, which is presently the most suitable manipulator for fruit-picking tasks. The soft robotic device is manufactured from a composite of Ecoflex 00-30 Room Temperature Vulcanisation Rubber and polymer mesh. This paper describes the specification, design, manufacture and validation of the novel soft robotic gripper as it emerged from the conceptual phase into its application domain (kiwifruit gripping and manipulation). The physical results are crossexamined with those from FEA analysis.


  • A Systematic Design Strategy for Antagonistic Joints Actuated by Artificial Muscles

    by Steven Dirven, Andrew McDaid

    Characterization, modeling, and control of pneumatic artificial muscles is typically demonstrated in an antagonistic architecture. There are many conflicting design constraints when designing these systems, resulting in many different styles of testing apparatus. A novel, systematic design methodology is proposed to improve these architectural constraints and describe the envelope of possible system outputs in terms of displacement and torque/force. It is founded upon a mathematical expression of actuator-model convolution. The proposed systematic antagonistic design by convolution (SADC) method involves three steps. First, model the workspace capability of each fluidic muscle. Second, devise the physical layout of the antagonistic apparatus by convolution, which investigates the structure for output workspace dexterity. Finally, establish trajectories and control, which is left to the application engineer. This method reduces the focus on the actuator capability, and instead represents a general method to approach system-level specification and design. The new SADC methodology facilitates design for a larger symmetric force capability. It is demonstrated for two cases, a symmetric and an asymmetric antagonistic system. It contributes a new pathway to explore optimization of antagonistic workspace symmetry at a system level and aids the engineer in visualizing architectural tradeoffs. It is independent of the application's control methodology and can be modified to examine alternative cost functions that require optimization.


  • Biomimetic Investigation of Intrabolus Pressure Signatures by a Peristaltic Swallowing Robot

    by Steven Dirven, Weiliang Xu, Leo K. Cheng, Jacqueline Allen

    The relationships among bolus formulation, engineering rheometric quantities, and peristaltic transport effects are examined in this paper. Investigation of a series of synthetic bolus materials and swallowing strategies is conducted using a novel peristaltic swallowing robot inspired by esophageal swallowing, which manifests as a benchtop rheological instrument. To determine the validity of biomimetic swallowing, manometry, a clinical technique for capturing swallowing pressure profiles is used to establish congruence between the robotic findings and those of a clinical nature. To determine the contribution of the bolus and swallowing strategy to the intraluminal pressure signature (ILPS), three parameters were varied: peristaltic wave velocity (20, 30, 40 mm s -1 ), wavefront length (40, 50, and 60 mm) and starch thickener (Nutulis, Nutricia) concentration (25, 50, 75, 100, and 150 g L -1 ) were investigated. Wave velocity and starch-based bolus formulation concentration were found to exhibit the most profound changes in the intrabolus pressure signatures. The highest bolus tail pressure gradient of 0.33 kPa mm -1 was achieved with a 150 g L -1 bolus formulation being transported at 40 mm s -1 with a wavefront length of 60 mm. In each dimension, the relationship between the parameters and features of the manometric pressure signature are found to be nonlinear owing to the shear-thinning, non-Newtonian nature of the model bolus fluid. The robotic ILPSs are synonymous with those of a clinical nature, suggesting that the swallowing robot has merit as a novel, biologically inspired, bolus investigation tool external to the human body.


  • Sinusoidal Peristaltic Waves in Soft Actuator for Mimicry of Esophageal Swallowing

    by Steven Dirven, Weiliang Xu, Leo K. Cheng

    In order to understand fluid transport throughout esophageal swallowing in man, a biologically inspired soft-robotic peristaltic actuator has been designed and manufactured to perform biomimetic swallowing. To achieve congruence with current mathematical modeling techniques for esophageal peristalsis, this paper examines the capability of the device (empirical) towards achieving sinusoidal transport waves with variations of clinically significant parameters such as amplitude and wavelength. The performance of the device to fit the commanded trajectory, by minimization of mean squared error, is tested over the range of wavefront length 30 ≤ λ/2 ≤ 60 mm and amplitude 6-8 mm in a two-dimensional capability analysis. It is found that the device is capable of achieving propagation of families of wave shapes with less than 5% full scale mean error, which improves for increasing wavefront length and reducing amplitude. The aim for the device in the future is to inspire a novel rheometric technique in the physical domain which characterizes fluid formulations based on intrabolus pressure signatures. This analysis expresses the trajectory generation technique and performance of the novel device to produce continuous peristaltic waves towards biomimetic swallowing.


  • Soft Actuator Mimicking Human Esophageal Peristalsis for a Swallowing Robot

    by F. J. Chen, S. Dirven, W. L. Xu, X. N. Li

    Provision of modified foods and drinks is one of the approaches for dysphagia management, which is based on the assumption that food with proper texture and rheological properties will allow dysphagia patients to swallow safely and maintain adequate nutrition. However, lack of information about the in vivo swallowing process and its interaction with food flow has obstructed the effective management of dysphagia. In the esophageal swallowing stage, masticated food is transported through the esophagus to the stomach by a peristaltic mechanism, which is generated by sequential contraction and relaxation of esophageal muscles. Inspired by this behavior, a soft actuator is proposed to provide a nonrisk environment aiming to facilitate investigations of the most effective properties of food for the management of the swallowing disorders. The wave-like motion is first specified according to the in vivo measurement of human esophageal peristalsis. Finite-element analysis simulations are carried out to aid the structure design before prototype manufacture. Constructed by casting silicon rubber in a three-dimensional (3-D) printed customized mold, the novel actuator has soft structure resembling its human counterpart, which has a flexible muscular structure. Multiple layers of inflatable chambers are embedded and distributed along the axis of a food passage regularly, which locates at the center of the actuator. The actuator is capable of generating a peristaltic wave and pushing a bolus along the passage. The closure of the tube and the velocity of the propagation wave are going to be adjusted to achieve the trajectories recorded experimentally, by regulating the compressed air pressure pumped into chambers actively.


  • Design and Characterization of a Peristaltic Actuator Inspired by Esophageal Swallowing

    by Steven Dirven, Feijiao Chen, Weiliang Xu, John E. Bronlund, Jacqueline Allen, Leo K. Cheng

    The specification and design of a novel peristaltic actuator is communicated. The actuation manifests as a continuous, distributed, and compliant peristaltic actuation. The occlusive nature of force distribution on the transport conduit results in materials being transported in front of a wave which has features of geometry and wave tail seal pressure. The behavior of these aspects profoundly affects the transport process. The device, of silicone rubber construction, has no internal skeletal structure and is pneumatically actuated which allows for continuous and compliant transport. The device is characterized by the synergy of geometrical and occlusive pressure measurements in response to actuation. This is performed for the “dry swallow” case (with no bolus) for single peak, single inflection waves. Techniques typical of medical investigation were exploited. Wave geometry was captured by articulography, complemented by wave seal pressure investigation by manometry. This paper describes the inspiration, specification, and experimental techniques used to develop and characterize the behavior of the biologically inspired, peristaltic, robotic device for assertion pressures up to 71.5 kPa. It is found that the device is capable of producing wave amplitudes and seal pressures of a similar magnitude (complete occlusion with >15-kPa seal) to the human esophagus which confirms achievement of the fundamental peristaltic parameters.


  • Design and Fabrication of a Soft Actuator for a Swallowing Robot

    by Fei-Jiao Chen, Steven Dirven, Weiliang Xu, Xiao-Ning Li, John Bronlund