Simeon Nill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simeon Nill has a total of 202 co-authors. Here are the top co-authors by number of shared publications:
- Uwe Oelfke
Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, London, SM2 5PT, United Kingdom of Great Britain and Northern Ireland
14 shared publications - Uwe Oelfke
Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK and Joint Department of Physics The Royal Marsden NHS Foundation Trust London UK
12 shared publications - Alex Dunlop
The Joint Department of Physics, The Royal Marsden Hospital and the Institute of Cancer Research, London, UK
9 shared publications - Sophie E. Alexander
Department of Radiation Oncology, The Royal Marsden Hospital NHS Foundation Trust, London, United Kingdom; The Institute of Cancer Research, London, United Kingdom
8 shared publications - Adam Mitchell
Joint Department of Physics, The Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, London, United Kingdom
7 shared publications - Martin F. Fast
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
7 shared publications
Latest Publications
- 4 July 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111356
Pre-treatment PSQA – Do we still need to measure and what are adequate alternatives?
- 4 July 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111356
Pre-treatment PSQA – Do we still need to measure and what are adequate alternatives?
- Open Access
- 3 June 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 60, 101207
Is rectal preparation necessary in contemporary image-guided prostate radiotherapy?
- 3 June 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 60, 101207
Open AccessIs rectal preparation necessary in contemporary image-guided prostate radiotherapy?
- Open Access
- 30 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 220, 111547
Factors associated with arm swelling in patients undergoing surgery and radiotherapy for breast cancer within the FAST-Forward trial nodal sub-study
- 30 April 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 220, 111547
Open AccessFactors associated with arm swelling in patients undergoing surgery and radiotherapy for breast cancer within the FAST-Forward trial nodal sub-study
- Open Access
- 20 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9)
Impact of daily volumetric imaging on target tracking without fiducial markers during robotic treatment of pancreas
Objective. Treatment of pancreas using Cyberknife is usually accomplished using radio-opaque fiducial markers that can be visualised on the orthogonal kilovoltage imaging system, but implantation of markers can lead to complications. This study therefore describes a method for pancreas tracking without fiducial markers and estimates the improvement in accuracy that can be achieved by additional daily pre-treatment volumetric imaging. Approach. Fiducial markers were artificially removed from the digitally reconstructed radiographs and treatment images of eight previously treated patients. Pancreas position was identified using a combination of local rigid registrations and inter- and intra-fraction motion models. The optimum effect of daily volumetric imaging was simulated by correcting the mean tracking position to match the mean position observed using fiducials. The impact of residual error on the dose distribution was estimated by shifting and recalculating the treatment plan. Main results. Median absolute tracking accuracy without fiducials over the 2823 acquired images is 3.8 mm (range 0.2 mm – 19.9 mm) without daily volumetric imaging. The lower bound of accuracy is 2.3 mm (0.1 mm – 18.5 mm) when daily volumetric imaging is used. The former scenario reduces the D95% of the planning target volume by a median of 2.5 Gy (1.0 Gy – 10.2 Gy) compared to the planned dose distribution, whereas the latter scenario reduces D95% by 1.4 Gy (0.4 Gy – 2.8 Gy). In neither case is the D95% of the clinical target volume substantially lowered below the prescription. Median D0.5cc to critical structures changes by less than 2 Gy. Significance. When tracking the target without fiducial markers, a planning target margin of 3–5 mm is sufficient to ensure that the clinical target volume receives the desired prescribed dose, but the spatial accuracy and target coverage are considerably improved by using daily volumetric imaging.
- 20 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9)
Open AccessImpact of daily volumetric imaging on target tracking without fiducial markers during robotic treatment of pancreas
Objective. Treatment of pancreas using Cyberknife is usually accomplished using radio-opaque fiducial markers that can be visualised on the orthogonal kilovoltage imaging system, but implantation of markers can lead to complications. This study therefore describes a method for pancreas tracking without fiducial markers and estimates the improvement in accuracy that can be achieved by additional daily pre-treatment volumetric imaging. Approach. Fiducial markers were artificially removed from the digitally reconstructed radiographs and treatment images of eight previously treated patients. Pancreas position was identified using a combination of local rigid registrations and inter- and intra-fraction motion models. The optimum effect of daily volumetric imaging was simulated by correcting the mean tracking position to match the mean position observed using fiducials. The impact of residual error on the dose distribution was estimated by shifting and recalculating the treatment plan. Main results. Median absolute tracking accuracy without fiducials over the 2823 acquired images is 3.8 mm (range 0.2 mm – 19.9 mm) without daily volumetric imaging. The lower bound of accuracy is 2.3 mm (0.1 mm – 18.5 mm) when daily volumetric imaging is used. The former scenario reduces the D95% of the planning target volume by a median of 2.5 Gy (1.0 Gy – 10.2 Gy) compared to the planned dose distribution, whereas the latter scenario reduces D95% by 1.4 Gy (0.4 Gy – 2.8 Gy). In neither case is the D95% of the clinical target volume substantially lowered below the prescription. Median D0.5cc to critical structures changes by less than 2 Gy. Significance. When tracking the target without fiducial markers, a planning target margin of 3–5 mm is sufficient to ensure that the clinical target volume receives the desired prescribed dose, but the spatial accuracy and target coverage are considerably improved by using daily volumetric imaging.
- Open Access
- 6 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 216, 111363
Acute adverse events in the DESTINATION 1 trial: A prospective prostate SBRT dose de-escalation feasibility study
- 6 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 216, 111363
Open AccessAcute adverse events in the DESTINATION 1 trial: A prospective prostate SBRT dose de-escalation feasibility study
- Open Access
- 4 October 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 36, 100348
Evaluating participant experiences and tolerability with MR Linac imaging
- 4 October 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 36, 100348
Open AccessEvaluating participant experiences and tolerability with MR Linac imaging
- Open Access
- 19 July 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 211, 111053
Towards rapid and efficient simulation-free radiotherapy: MR guided adaptive prostate radiotherapy on the MR-Linac using diagnostic MRI reference planning
- 19 July 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 211, 111053
Open AccessTowards rapid and efficient simulation-free radiotherapy: MR guided adaptive prostate radiotherapy on the MR-Linac using diagnostic MRI reference planning
- Open Access
- 17 June 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 54, 100994
Evaluation of therapeutic radiographer target volume contouring for magnetic resonance image guided online adaptive bladder radiotherapy
- 17 June 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 54, 100994
Open AccessEvaluation of therapeutic radiographer target volume contouring for magnetic resonance image guided online adaptive bladder radiotherapy
- Open Access
- 24 March 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1171) , 993-1004
The importance of standardization and challenges of dosimetry in conventional preclinical radiation biology research
To fully exploit the prospects presented by the increasing focus on biological approaches for enhancing radiotherapy outcomes, improvements in repeatability and translatability of radiobiological and preclinical studies are required. This requires the development and adoption of appropriate dosimetric standards and reproducible approaches to increase confidence in the studies, enabling inter-laboratory validation and facilitating clinical translation. An Institute of Physics and Engineering in Medicine (IPEM) working party reviewed the current status and challenges associated with dosimetry of medium-energy X-rays and make recommendations with the aim to optimize the potential clinical significance of radiobiological preclinical investigations. The paper discusses the currently available resources with technical recommendations for performing dosimetry in medium-energy X-rays, along with the consequences of lack of standardization and implications of dose inhomogeneity. It is clear that there is still a gap in understanding the needs for standardization of dosimetric aspects of preclinical and radiobiological studies. It is recommended that these radiobiology studies should be conducted in partnership with medical/radiation physicists. This collaboration ensures the correct utilization of suitable dosimetry systems, thus guaranteeing accuracy and consistency of dose delivery. Appropriate calibration and traceability to national/international standards laboratory, along with regular quality assurance of radiation devices, are paramount to reproducibility. Additionally, it is critical that experimental details and associated dosimetry are sufficiently reported to ensure accurate replication that enables reanalysis including evaluation of dose distributions. Increasing awareness among the researchers and the funding bodies was identified as a crucial step to improve translatability and appropriate resources are budgeted to increase the value for money of research proposals. The proposed recommendations will serve as a vital resource for researchers, encouraging uniformity in experimental design and improving the translatability of preclinical research to clinical settings.
- 24 March 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1171) , 993-1004
Open AccessThe importance of standardization and challenges of dosimetry in conventional preclinical radiation biology research
To fully exploit the prospects presented by the increasing focus on biological approaches for enhancing radiotherapy outcomes, improvements in repeatability and translatability of radiobiological and preclinical studies are required. This requires the development and adoption of appropriate dosimetric standards and reproducible approaches to increase confidence in the studies, enabling inter-laboratory validation and facilitating clinical translation. An Institute of Physics and Engineering in Medicine (IPEM) working party reviewed the current status and challenges associated with dosimetry of medium-energy X-rays and make recommendations with the aim to optimize the potential clinical significance of radiobiological preclinical investigations. The paper discusses the currently available resources with technical recommendations for performing dosimetry in medium-energy X-rays, along with the consequences of lack of standardization and implications of dose inhomogeneity. It is clear that there is still a gap in understanding the needs for standardization of dosimetric aspects of preclinical and radiobiological studies. It is recommended that these radiobiology studies should be conducted in partnership with medical/radiation physicists. This collaboration ensures the correct utilization of suitable dosimetry systems, thus guaranteeing accuracy and consistency of dose delivery. Appropriate calibration and traceability to national/international standards laboratory, along with regular quality assurance of radiation devices, are paramount to reproducibility. Additionally, it is critical that experimental details and associated dosimetry are sufficiently reported to ensure accurate replication that enables reanalysis including evaluation of dose distributions. Increasing awareness among the researchers and the funding bodies was identified as a crucial step to improve translatability and appropriate resources are budgeted to increase the value for money of research proposals. The proposed recommendations will serve as a vital resource for researchers, encouraging uniformity in experimental design and improving the translatability of preclinical research to clinical settings.