Martin Stauber
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin Stauber has a total of 174 co-authors. Here are the top co-authors by number of shared publications:
- Ralph Müller
Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
30 shared publications - Gerrit Harry van Lenthe
KU Leuven
9 shared publications Marco Stampanoni
Institute for Biomedical Engineering, Zurich 8092, Zurich, Zürich, 8092, SWITZERLAND
8 shared publicationsM. Stampanoni
5 shared publications- Philipp Schneider
University of Southampton
5 shared publications R. Voide
Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
5 shared publications
Latest Publications
- 14 February 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (3) , 032502
Bottom-up Gold Filling of Trenches in Curved Wafers
A Bi 3 + -stimulated Au electrodeposition process in slightly alkaline Na 3 Au SO 3 2 + Na 2 SO 3 electrolytes has been previously demonstrated for void-free extreme bottom-up filling of high aspect ratio trenches in gratings that are key to advanced X-ray imaging technologies. Effective use of the full area of the gratings with conventional X-ray sources requires they have a finite radius of curvature to align the high aspect ratio Au-filled trenches with divergent X-rays. With that in mind, this work demonstrates bottom-up Au filling in gratings that are attached to curved holders. Contactless mapping of the Au-filled gratings captures residual curvature that is retained after their release from the curved holders (i.e., intrinsic curvature). X-ray diffraction captures the elastic strains in the Si underlying the Au-filled trenches of the grating. Complementary measurements on the surfaces of unpatterned Si wafers mounted on curved holders capture the actual curvatures and strains imposed in the mounted gratings. The gratings, either intrinsically curved or re-bent, provide high visibility across the entire field of view of an X-ray phase contrast imaging system with elastic strains substantially below those in planar gratings bent to the same radius.
- 14 February 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (3) , 032502
Bottom-up Gold Filling of Trenches in Curved Wafers
A Bi 3 + -stimulated Au electrodeposition process in slightly alkaline Na 3 Au SO 3 2 + Na 2 SO 3 electrolytes has been previously demonstrated for void-free extreme bottom-up filling of high aspect ratio trenches in gratings that are key to advanced X-ray imaging technologies. Effective use of the full area of the gratings with conventional X-ray sources requires they have a finite radius of curvature to align the high aspect ratio Au-filled trenches with divergent X-rays. With that in mind, this work demonstrates bottom-up Au filling in gratings that are attached to curved holders. Contactless mapping of the Au-filled gratings captures residual curvature that is retained after their release from the curved holders (i.e., intrinsic curvature). X-ray diffraction captures the elastic strains in the Si underlying the Au-filled trenches of the grating. Complementary measurements on the surfaces of unpatterned Si wafers mounted on curved holders capture the actual curvatures and strains imposed in the mounted gratings. The gratings, either intrinsically curved or re-bent, provide high visibility across the entire field of view of an X-ray phase contrast imaging system with elastic strains substantially below those in planar gratings bent to the same radius.
- Open Access
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (3) , 1033-1044
Data-Driven Gradient Regularization for Quasi-Newton Optimization in Iterative Grating Interferometry CT Reconstruction
Grating interferometry CT (GI-CT) is a promising technology that could play an important role in future breast cancer imaging. Thanks to its sensitivity to refraction and small-angle scattering, GI-CT could augment the diagnostic content of conventional absorption-based CT. However, reconstructing GI-CT tomographies is a complex task because of ill problem conditioning and high noise amplitudes. It has previously been shown that combining data-driven regularization with iterative reconstruction is promising for tackling challenging inverse problems in medical imaging. In this work, we present an algorithm that allows seamless combination of data-driven regularization with quasi-Newton solvers, which can better deal with ill-conditioned problems compared to gradient descent-based optimization algorithms. Contrary to most available algorithms, our method applies regularization in the gradient domain rather than in the image domain. This comes with a crucial advantage when applied in conjunction with quasi-Newton solvers: the Hessian is approximated solely based on denoised data. We apply the proposed method, which we call GradReg, to both conventional breast CT and GI-CT and show that both significantly benefit from our approach in terms of dose efficiency. Moreover, our results suggest that thanks to its sharper gradients that carry more high spatial-frequency content, GI-CT can benefit more from GradReg compared to conventional breast CT. Crucially, GradReg can be applied to any image reconstruction task which relies on gradient-based updates.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (3) , 1033-1044
Open AccessData-Driven Gradient Regularization for Quasi-Newton Optimization in Iterative Grating Interferometry CT Reconstruction
Grating interferometry CT (GI-CT) is a promising technology that could play an important role in future breast cancer imaging. Thanks to its sensitivity to refraction and small-angle scattering, GI-CT could augment the diagnostic content of conventional absorption-based CT. However, reconstructing GI-CT tomographies is a complex task because of ill problem conditioning and high noise amplitudes. It has previously been shown that combining data-driven regularization with iterative reconstruction is promising for tackling challenging inverse problems in medical imaging. In this work, we present an algorithm that allows seamless combination of data-driven regularization with quasi-Newton solvers, which can better deal with ill-conditioned problems compared to gradient descent-based optimization algorithms. Contrary to most available algorithms, our method applies regularization in the gradient domain rather than in the image domain. This comes with a crucial advantage when applied in conjunction with quasi-Newton solvers: the Hessian is approximated solely based on denoised data. We apply the proposed method, which we call GradReg, to both conventional breast CT and GI-CT and show that both significantly benefit from our approach in terms of dose efficiency. Moreover, our results suggest that thanks to its sharper gradients that carry more high spatial-frequency content, GI-CT can benefit more from GradReg compared to conventional breast CT. Crucially, GradReg can be applied to any image reconstruction task which relies on gradient-based updates.
- 18 July 2023
- Published by Optica Publishing Group in Optica
- Vol. 10 (7) , 938-943
Increased dose efficiency of breast CT with grating interferometry
Refraction-based x-ray imaging can overcome the fundamental contrast limit of computed tomography (CT), particularly in soft tissue, but so far has been constrained to high-dose ex vivo applications or required highly coherent x-ray sources, such as synchrotrons. Here we demonstrate that grating interferometry (GI) is more dose efficient than conventional CT in imaging of human breast under close-to-clinical conditions. Our system, based on a conventional source and commercial gratings, outperformed conventional CT for spatial resolutions better than 263 µm and absorbed dose of 16 mGy. The sensitivity of GI is constrained by grating fabrication, and further progress will lead to significant improvements of clinical CT.
- 18 July 2023
- Published by Optica Publishing Group in Optica
- Vol. 10 (7) , 938-943
Increased dose efficiency of breast CT with grating interferometry
Refraction-based x-ray imaging can overcome the fundamental contrast limit of computed tomography (CT), particularly in soft tissue, but so far has been constrained to high-dose ex vivo applications or required highly coherent x-ray sources, such as synchrotrons. Here we demonstrate that grating interferometry (GI) is more dose efficient than conventional CT in imaging of human breast under close-to-clinical conditions. Our system, based on a conventional source and commercial gratings, outperformed conventional CT for spatial resolutions better than 263 µm and absorbed dose of 16 mGy. The sensitivity of GI is constrained by grating fabrication, and further progress will lead to significant improvements of clinical CT.
- 24 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (5) , 9052-9071
Towards clinical-dose grating interferometry breast CT with fused intensity-based iterative reconstruction
X-ray grating interferometry CT (GI-CT) is an emerging imaging modality which provides three complementary contrasts that could increase the diagnostic content of clinical breast CT: absorption, phase, and dark-field. Yet, reconstructing the three image channels under clinically compatible conditions is challenging because of severe ill-conditioning of the tomographic reconstruction problem. In this work we propose to solve this problem with a novel reconstruction algorithm that assumes a fixed relation between the absorption and the phase-contrast channel to reconstruct a single image by automatically fusing the absorption and phase channels. The results on both simulations and real data show that, enabled by the proposed algorithm, GI-CT outperforms conventional CT at a clinical dose.
- 24 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (5) , 9052-9071
Towards clinical-dose grating interferometry breast CT with fused intensity-based iterative reconstruction
X-ray grating interferometry CT (GI-CT) is an emerging imaging modality which provides three complementary contrasts that could increase the diagnostic content of clinical breast CT: absorption, phase, and dark-field. Yet, reconstructing the three image channels under clinically compatible conditions is challenging because of severe ill-conditioning of the tomographic reconstruction problem. In this work we propose to solve this problem with a novel reconstruction algorithm that assumes a fixed relation between the absorption and the phase-contrast channel to reconstruct a single image by automatically fusing the absorption and phase channels. The results on both simulations and real data show that, enabled by the proposed algorithm, GI-CT outperforms conventional CT at a clinical dose.
- Open Access
Analysis of the Morpho-Geometrical Changes of the Root Canal System Produced by TF Adaptive vs. BioRace: A Micro-Computed Tomography Study
We aimed to analyze the morpho-geometric changes of the root canal system created by two rotary systems (TF Adaptive and BioRace) using micro-CT technology. Two concepts of rotary file system kinematics, continuous rotation and adaptive kinematics, were used in root canal preparation. Twenty mandibular molars (n = 20) were selected with the following criteria: the teeth have mesial roots with a single and continuous isthmus connecting the mesiobuccal and mesiolingual canals (Vertucci’s Type I configuration) and distal roots with independent canals. Teeth were scanned at a resolution of 14 μm. Canals were divided equally into two groups and then enlarged sequentially using the BioRace system and TF Adaptive system according to manufacturer protocol. Co-registered images, before and after preparation, were evaluated for morphometric measurements of canal surface area, volume, structure model index, thickness, straightening, and un-instrumented surface area. Before and after preparation, data were statistically analyzed using a paired sample t-test. After preparation, data were analyzed using an unpaired sample test. The preparation by both systems significantly changed canal surface area, volume, structure model index, and thickness in both systems. There were no significant differences between instrument types with respect to these parameters (p > 0.05). TF Adaptive was associated with less straightening (8% compared with 17% for BioRace in the mesial canal, p > 0.05). Both instrumentation systems produced canal preparations with adequate geometrical changes. BioRace straightened the mesial canals more than TF Adaptive.
Open AccessAnalysis of the Morpho-Geometrical Changes of the Root Canal System Produced by TF Adaptive vs. BioRace: A Micro-Computed Tomography Study
We aimed to analyze the morpho-geometric changes of the root canal system created by two rotary systems (TF Adaptive and BioRace) using micro-CT technology. Two concepts of rotary file system kinematics, continuous rotation and adaptive kinematics, were used in root canal preparation. Twenty mandibular molars (n = 20) were selected with the following criteria: the teeth have mesial roots with a single and continuous isthmus connecting the mesiobuccal and mesiolingual canals (Vertucci’s Type I configuration) and distal roots with independent canals. Teeth were scanned at a resolution of 14 μm. Canals were divided equally into two groups and then enlarged sequentially using the BioRace system and TF Adaptive system according to manufacturer protocol. Co-registered images, before and after preparation, were evaluated for morphometric measurements of canal surface area, volume, structure model index, thickness, straightening, and un-instrumented surface area. Before and after preparation, data were statistically analyzed using a paired sample t-test. After preparation, data were analyzed using an unpaired sample test. The preparation by both systems significantly changed canal surface area, volume, structure model index, and thickness in both systems. There were no significant differences between instrument types with respect to these parameters (p > 0.05). TF Adaptive was associated with less straightening (8% compared with 17% for BioRace in the mesial canal, p > 0.05). Both instrumentation systems produced canal preparations with adequate geometrical changes. BioRace straightened the mesial canals more than TF Adaptive.
- 9 November 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 23 (7) , 3063-3071
Microstructural volumetric analysis of lateral ridge augmentation using differently conditioned tooth roots
Previous research revealed that autogenous tooth roots may be biologically equivalent to conventional bone grafts for lateral ridge augmentation. However, these analyses were limited to two dimensions, whereas healing is a volumetric process. The present study aimed at volumetrically assessing the microstructure following lateral ridge augmentation using extracted tooth roots.
- 9 November 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 23 (7) , 3063-3071
Microstructural volumetric analysis of lateral ridge augmentation using differently conditioned tooth roots
Previous research revealed that autogenous tooth roots may be biologically equivalent to conventional bone grafts for lateral ridge augmentation. However, these analyses were limited to two dimensions, whereas healing is a volumetric process. The present study aimed at volumetrically assessing the microstructure following lateral ridge augmentation using extracted tooth roots.
- 6 January 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (3) , 389-396
Patient-specific estimation of detailed cochlear shape from clinical CT images
A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detailed patient-specific cochlear shape from CT images.
- 6 January 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (3) , 389-396
Patient-specific estimation of detailed cochlear shape from clinical CT images
A personalized estimation of the cochlear shape can be used to create computational anatomical models to aid cochlear implant (CI) surgery and CI audio processor programming ultimately resulting in improved hearing restoration. The purpose of this work is to develop and test a method for estimation of the detailed patient-specific cochlear shape from CT images.
- Open Access
Automatic registration of 2D histological sections to 3D microCT volumes: Trabecular bone
- Open Access
- 19 September 2017
- Published by Springer Nature in Scientific Data
- Vol. 4 (1) , 170132
A multiscale imaging and modelling dataset of the human inner ear
Understanding the human inner ear anatomy and its internal structures is paramount to advance hearing implant technology. While the emergence of imaging devices allowed researchers to improve understanding of intracochlear structures, the difficulties to collect appropriate data has resulted in studies conducted with few samples. To assist the cochlear research community, a large collection of human temporal bone images is being made available. This data descriptor, therefore, describes a rich set of image volumes acquired using cone beam computed tomography and micro-CT modalities, accompanied by manual delineations of the cochlea and sub-compartments, a statistical shape model encoding its anatomical variability, and data for electrode insertion and electrical simulations. This data makes an important asset for future studies in need of high-resolution data and related statistical data objects of the cochlea used to leverage scientific hypotheses. It is of relevance to anatomists, audiologists, computer scientists in the different domains of image analysis, computer simulations, imaging formation, and for biomedical engineers designing new strategies for cochlear implantations, electrode design, and others.
- 19 September 2017
- Published by Springer Nature in Scientific Data
- Vol. 4 (1) , 170132
Open AccessA multiscale imaging and modelling dataset of the human inner ear
Understanding the human inner ear anatomy and its internal structures is paramount to advance hearing implant technology. While the emergence of imaging devices allowed researchers to improve understanding of intracochlear structures, the difficulties to collect appropriate data has resulted in studies conducted with few samples. To assist the cochlear research community, a large collection of human temporal bone images is being made available. This data descriptor, therefore, describes a rich set of image volumes acquired using cone beam computed tomography and micro-CT modalities, accompanied by manual delineations of the cochlea and sub-compartments, a statistical shape model encoding its anatomical variability, and data for electrode insertion and electrical simulations. This data makes an important asset for future studies in need of high-resolution data and related statistical data objects of the cochlea used to leverage scientific hypotheses. It is of relevance to anatomists, audiologists, computer scientists in the different domains of image analysis, computer simulations, imaging formation, and for biomedical engineers designing new strategies for cochlear implantations, electrode design, and others.