Alison Deary
Research Subjects
Alison Deary has a total of 176 co-authors. Here are the top co-authors by number of shared publications:
- Nicola Curry
Oxford Haemophilia and Thrombosis Centre, Nuffield Orthopaedic Centre, Oxford, UK
5 shared publications - Ross Davenport
Barts Health NHS Trust, London, UK
4 shared publications - Simon J. Stanworth
NHS Blood and Transplant Bristol UK
4 shared publications Charlotte Llewelyn
3 shared publications- Helen Thomas
NHS Blood and Transplant Clinical Trials Unit, Bristol, UK
3 shared publications - Laura Green
Transfusion Transformation Programme NHS Blood and Transplant (NHSBT) Oxford UK
3 shared publications
Latest Publications
- 23 January 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (2)
Multicenter Double-Blind Study Evaluating AI-Driven Detection of Proximal Deep Vein Thrombosis
- 23 January 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (2)
Multicenter Double-Blind Study Evaluating AI-Driven Detection of Proximal Deep Vein Thrombosis
- Open Access
- 1 November 2024
- Published by National Institute for Health and Care Research in Health Technology Assessment
- Vol. 28 (76) , 1-69
Early high-dose cryoprecipitate to reduce mortality in adult patients with traumatic haemorrhage: the CRYOSTAT-2 RCT with cost-effectiveness analysis
Background: Traumatic haemorrhage is common after severe injury, leading to disability and death. Cryoprecipitate, a source of fibrinogen, may improve outcomes for patients with traumatic haemorrhage. Objective: To investigate the effects of early fibrinogen supplementation in the form of 3 pools (15 units, approximately 6 g of fibrinogen) of cryoprecipitate on 28-day mortality. Design: A randomised, parallel-group, unblinded, multicentre, international trial and economic evaluation. Patients were randomised to either the intervention (early cryoprecipitate) or the comparator (standard major haemorrhage protocol) arm via opaque, sealed envelopes in the emergency department or the transfusion laboratory/blood bank. All analyses were performed on an intention-to-treat basis. A cost-effectiveness analysis was undertaken. Setting: Twenty-five major trauma centres in the UK and one level 1 trauma centre in the USA. Participants: Adults who had traumatic haemorrhage following severe injury requiring activation of the major haemorrhage protocol and had received a blood transfusion. Intervention: Early cryoprecipitate – 3 pools (equivalent to 15 single units of cryoprecipitate or 6 g of fibrinogen supplementation), infused as rapidly as possible, within 90 minutes of arrival at hospital in addition to standard major haemorrhage protocol or standard major haemorrhage protocol only. Main outcome measures: The primary outcome was all-cause mortality at 28 days. The secondary outcomes were all-cause mortality at 6 hours, 24 hours, 6 months and 12 months from admission; death from bleeding at 6 hours and 24 hours; transfusion requirements at 24 hours from admission; destination of participant at discharge; quality-of-life measurements (EuroQol-5 Dimensions, five-level version and Glasgow Outcome Scale) at discharge/day 28 and 6 months after injury; and hospital resource use up to discharge or day 28 (including ventilator-days, hours spent in critical care and inpatient stays). Results: Eight hundred and five patients were randomised to receive the standard major haemorrhage protocol (control arm). Seven hundred and ninety-nine patients were randomised to receive an additional three pools of cryoprecipitate in addition to standard care (intervention arm). Baseline characteristics appeared well matched. Patients had a median age of 39 (interquartile range 26–55) years, and the majority (79%) were male. All-cause 28-day mortality (n = 1531 patients; intention to treat) was 25.3% in the intervention arm compared with 26.1% in the control arm (odds ratio 0.96; p = 0.74). Limitations: There was variability in the timing of cryoprecipitate administration, with overlap between the treatment arms, limiting the degree of intervention separation. Conclusions: There was no evidence that early empiric administration of high-dose cryoprecipitate reduced the risk of death in unselected patients with traumatic haemorrhage. There was also no difference in adverse events. The cost-effectiveness of the intervention was similar to that of standard care. Future work: Research to evaluate if fibrinogen replacement is more beneficial for selected patients, for example those with low fibrinogen blood levels, is needed, as is further exploration of whether there is a difference in outcome according to mechanism of injury. Trial registration: This trial is registered as ISRCTN14998314. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 15/57/02) and is published in full in Health Technology Assessment; Vol. 28, No. 76. See the NIHR Funding and Awards website for further award information.
- 1 November 2024
- Published by National Institute for Health and Care Research in Health Technology Assessment
- Vol. 28 (76) , 1-69
Open AccessEarly high-dose cryoprecipitate to reduce mortality in adult patients with traumatic haemorrhage: the CRYOSTAT-2 RCT with cost-effectiveness analysis
Background: Traumatic haemorrhage is common after severe injury, leading to disability and death. Cryoprecipitate, a source of fibrinogen, may improve outcomes for patients with traumatic haemorrhage. Objective: To investigate the effects of early fibrinogen supplementation in the form of 3 pools (15 units, approximately 6 g of fibrinogen) of cryoprecipitate on 28-day mortality. Design: A randomised, parallel-group, unblinded, multicentre, international trial and economic evaluation. Patients were randomised to either the intervention (early cryoprecipitate) or the comparator (standard major haemorrhage protocol) arm via opaque, sealed envelopes in the emergency department or the transfusion laboratory/blood bank. All analyses were performed on an intention-to-treat basis. A cost-effectiveness analysis was undertaken. Setting: Twenty-five major trauma centres in the UK and one level 1 trauma centre in the USA. Participants: Adults who had traumatic haemorrhage following severe injury requiring activation of the major haemorrhage protocol and had received a blood transfusion. Intervention: Early cryoprecipitate – 3 pools (equivalent to 15 single units of cryoprecipitate or 6 g of fibrinogen supplementation), infused as rapidly as possible, within 90 minutes of arrival at hospital in addition to standard major haemorrhage protocol or standard major haemorrhage protocol only. Main outcome measures: The primary outcome was all-cause mortality at 28 days. The secondary outcomes were all-cause mortality at 6 hours, 24 hours, 6 months and 12 months from admission; death from bleeding at 6 hours and 24 hours; transfusion requirements at 24 hours from admission; destination of participant at discharge; quality-of-life measurements (EuroQol-5 Dimensions, five-level version and Glasgow Outcome Scale) at discharge/day 28 and 6 months after injury; and hospital resource use up to discharge or day 28 (including ventilator-days, hours spent in critical care and inpatient stays). Results: Eight hundred and five patients were randomised to receive the standard major haemorrhage protocol (control arm). Seven hundred and ninety-nine patients were randomised to receive an additional three pools of cryoprecipitate in addition to standard care (intervention arm). Baseline characteristics appeared well matched. Patients had a median age of 39 (interquartile range 26–55) years, and the majority (79%) were male. All-cause 28-day mortality (n = 1531 patients; intention to treat) was 25.3% in the intervention arm compared with 26.1% in the control arm (odds ratio 0.96; p = 0.74). Limitations: There was variability in the timing of cryoprecipitate administration, with overlap between the treatment arms, limiting the degree of intervention separation. Conclusions: There was no evidence that early empiric administration of high-dose cryoprecipitate reduced the risk of death in unselected patients with traumatic haemorrhage. There was also no difference in adverse events. The cost-effectiveness of the intervention was similar to that of standard care. Future work: Research to evaluate if fibrinogen replacement is more beneficial for selected patients, for example those with low fibrinogen blood levels, is needed, as is further exploration of whether there is a difference in outcome according to mechanism of injury. Trial registration: This trial is registered as ISRCTN14998314. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 15/57/02) and is published in full in Health Technology Assessment; Vol. 28, No. 76. See the NIHR Funding and Awards website for further award information.
- 2 November 2022
- Published by Wiley in Transfusion Medicine
- Vol. 33 (2) , 123-131
The CRYOSTAT2 trial: The rationale and study protocol for a multi‐Centre, randomised, controlled trial evaluating the effects of early high‐dose cryoprecipitate in adult patients with major trauma haemorrhage requiring major haemorrhage protocol activation
Objectives: To describe the protocol for a multinational randomised, parallel, superiority trial, in which patients were randomised to receive early high‐dose cryoprecipitate in addition to standard major haemorrhage protocol (MHP), or Standard MHP alone.Background: Blood transfusion support for trauma‐related major bleeding includes red cells, plasma and platelets. The role of concentrated sources of fibrinogen is less clear and has not been evaluated in large clinical trials. Fibrinogen is a key pro‐coagulant factor that is essential for stable clot formation. A pilot trial had demonstrated that it was feasible to deliver cryoprecipitate as a source of fibrinogen within 90 min of admission.Methods: Randomisation was via opaque sealed envelopes held securely in participating Emergency Departments or transfusion laboratories. Early cryoprecipitate, provided as 3 pools (equivalent to 15 single units of cryoprecipitate or 6 g fibrinogen supplementation), was transfused as rapidly as possible, and started within 90 min of admission. Participants in both arms received standard treatment defined in the receiving hospital MHP. The primary outcome measure was all‐cause mortality at 28 days. Symptomatic thrombotic events including venous thromboembolism and arterial thrombotic events (myocardial infarction, stroke) were collected from randomisation up to day 28 or discharge from hospital. EQ5D‐5Land Glasgow Outcome Score were completed at discharge and 6 months. All analyses will be performed on an intention to treat basis, with per protocol sensitivity analysis.Results: The trial opened for recruitment in June 2017 and the final patient completed follow‐up in May 2022.Discussion: This trial will provide firmer evidence to evaluate the effectiveness and cost‐effectiveness of early high‐dose cryoprecipitate alongside the standard MHP in major traumatic haemorrhage.
- 2 November 2022
- Published by Wiley in Transfusion Medicine
- Vol. 33 (2) , 123-131
The CRYOSTAT2 trial: The rationale and study protocol for a multi‐Centre, randomised, controlled trial evaluating the effects of early high‐dose cryoprecipitate in adult patients with major trauma haemorrhage requiring major haemorrhage protocol activation
Objectives: To describe the protocol for a multinational randomised, parallel, superiority trial, in which patients were randomised to receive early high‐dose cryoprecipitate in addition to standard major haemorrhage protocol (MHP), or Standard MHP alone.Background: Blood transfusion support for trauma‐related major bleeding includes red cells, plasma and platelets. The role of concentrated sources of fibrinogen is less clear and has not been evaluated in large clinical trials. Fibrinogen is a key pro‐coagulant factor that is essential for stable clot formation. A pilot trial had demonstrated that it was feasible to deliver cryoprecipitate as a source of fibrinogen within 90 min of admission.Methods: Randomisation was via opaque sealed envelopes held securely in participating Emergency Departments or transfusion laboratories. Early cryoprecipitate, provided as 3 pools (equivalent to 15 single units of cryoprecipitate or 6 g fibrinogen supplementation), was transfused as rapidly as possible, and started within 90 min of admission. Participants in both arms received standard treatment defined in the receiving hospital MHP. The primary outcome measure was all‐cause mortality at 28 days. Symptomatic thrombotic events including venous thromboembolism and arterial thrombotic events (myocardial infarction, stroke) were collected from randomisation up to day 28 or discharge from hospital. EQ5D‐5Land Glasgow Outcome Score were completed at discharge and 6 months. All analyses will be performed on an intention to treat basis, with per protocol sensitivity analysis.Results: The trial opened for recruitment in June 2017 and the final patient completed follow‐up in May 2022.Discussion: This trial will provide firmer evidence to evaluate the effectiveness and cost‐effectiveness of early high‐dose cryoprecipitate alongside the standard MHP in major traumatic haemorrhage.
- 1 March 2022
- Published by National Institute for Health and Care Research in Programme Grants for Applied Research
- Vol. 10 (2) , 1-112
Enhanced feedback interventions to promote evidence-based blood transfusion guidance and reduce unnecessary use of blood components: the AFFINITIE research programme including two cluster factorial RCTs
Background: Blood transfusion is a common but costly treatment. Repeated national audits in the UK suggest that up to one-fifth of transfusions are unnecessary when judged against recommendations for good clinical practice. Audit and feedback seeks to improve patient care and outcomes by comparing clinical care against explicit standards. It is widely used internationally in quality improvement. Audit and feedback generally has modest but variable effects on patient care. A considerable scope exists to improve the impact that audit and feedback has, particularly through head-to-head trials comparing different ways of delivering feedback. Objectives: The AFFINITIE (Development & Evaluation of Audit and Feedback INterventions to Increase evidence-based Transfusion practIcE) programme aimed to design and evaluate enhanced feedback interventions, within a national blood transfusion audit programme, to promote evidence-based guidance and reduce the unnecessary use of blood components. We developed, piloted and refined two feedback interventions, ‘enhanced content’ and ‘enhanced follow-on’ (workstream 1), evaluated the effectiveness and cost-effectiveness of the two feedback interventions compared with standard feedback practice (workstream 2), examined intervention fidelity and contextual influences (workstream 3) and developed general implementation recommendations and tools for other audit and feedback programmes (workstream 4). Design: Interviews, observations and documentary analysis in four purposively sampled hospitals explored contemporary practice and opportunities for strengthening feedback. We developed two interventions: ‘enhanced content’, to improve the clarity and utility of feedback reports, and ‘enhanced follow-on’, to help hospital staff with action-planning (workstream 1). We conducted two linked 2 × 2 factorial cross-sectional cluster-randomised trials within transfusion audits for major surgery and haematological oncology, respectively (workstream 2). We randomised hospital clusters (the organisational level at which hospital transfusion teams operate) to enhanced or standard content or enhanced or standard follow-on. Outcome assessment was masked to assignment. Decision-analytic modelling evaluated the costs, benefits and cost-effectiveness of the feedback interventions in both trials from the perspective of the NHS. A parallel process evaluation used semistructured interviews, documentary analyses and web analytics to assess the fidelity of delivery, receipt and enactment and to identify contextual influences (workstream 3). We explored ways of improving the impact of national audits with their representatives (workstream 4). Setting and participants: All NHS hospital trusts and health boards participating in the National Comparative Audit of Blood Transfusions were invited to take part. Among 189 hospital trusts and health boards screened, 152 hospital clusters participated in the surgical audit. Among 187 hospital trusts and health boards screened, 141 hospital clusters participated in the haematology audit. Interventions: ‘Enhanced content’ aimed to ensure that the content and format of feedback reports were consistent with behaviour change theory and evidence. ‘Enhanced follow-on’ comprised a web-based toolkit and telephone support to facilitate local dissemination, planning and response to feedback. Main outcome measures: Proportions of acceptable transfusions, based on existing evidence and guidance and algorithmically derived from national audit data. Data sources: Trial primary outcomes were derived from manually collected, patient-level audit data. Secondary outcomes included routinely collected data for blood transfusion. Results: With regard to the transfusions in the major surgery audit, 135 (89%) hospital clusters participated from 152 invited. We randomised 69 and 66 clusters to enhanced and standard content, respectively, and 68 and 67 clusters to enhanced and standard follow-on, respectively. We analysed a total of 2222 patient outcomes at 12 months in 54 and 58 (enhanced and standard content, respectively) and 54 and 58 (enhanced and standard follow-on, respectively) hospital clusters. With regard to the haematology audit, 134 hospital clusters (95%) participated from 141 invited. We randomised 66 and 68 clusters to enhanced and standard content, respectively, and 67 clusters to both enhanced and standard follow-on. We analysed a total of 3859 patient outcomes at 12 months in 61 and 61 (enhanced and standard content, respectively) and 63 and 59 (enhanced and standard follow-on) hospital clusters. We found no effect of either of the enhanced feedback interventions in either trial across all outcomes. Incremental enhanced intervention costs ranged from £18 to £248 per site. The enhanced feedback interventions were dominated by the standard intervention in cost-effectiveness analyses. The interventions were delivered as designed and intended, but subsequent local engagement was low. Although the enhancements were generally acceptable, doubts about the credibility of the blood transfusion audits undermined the case for change. Limitations: Limitations included the number of participating clusters; loss to follow-up of trial clusters, reducing statistical power and validity; incomplete audit and cost data contributing to outcome measures; participant self-selection; reporting; missing data related to additional staff activity generated in response to receiving feedback; and recall biases in the process evaluation interviews. Conclusions: The enhanced feedback interventions were acceptable to recipients but were more costly and no more effective than standard feedback in reducing unnecessary use of blood components, and, therefore, should not be recommended on economic grounds. Future work: We have demonstrated the feasibility of embedding ambitious large-scale rigorous research within national audit programmes. Further head-to-head comparisons of different feedback interventions are needed in these programmes to identify cost-effective ways of increasing the impact of the interventions. Trial registration: This trial is registered as ISRCTN15490813. Funding: This project was funded by the National Institute for Health Research (NIHR) Programme Grants for Applied Research programme and will be published in full in Programme Grants for Applied Research; Vol. 10, No. 2. See the NIHR Journals Library website for further project information.
- 1 March 2022
- Published by National Institute for Health and Care Research in Programme Grants for Applied Research
- Vol. 10 (2) , 1-112
Enhanced feedback interventions to promote evidence-based blood transfusion guidance and reduce unnecessary use of blood components: the AFFINITIE research programme including two cluster factorial RCTs
Background: Blood transfusion is a common but costly treatment. Repeated national audits in the UK suggest that up to one-fifth of transfusions are unnecessary when judged against recommendations for good clinical practice. Audit and feedback seeks to improve patient care and outcomes by comparing clinical care against explicit standards. It is widely used internationally in quality improvement. Audit and feedback generally has modest but variable effects on patient care. A considerable scope exists to improve the impact that audit and feedback has, particularly through head-to-head trials comparing different ways of delivering feedback. Objectives: The AFFINITIE (Development & Evaluation of Audit and Feedback INterventions to Increase evidence-based Transfusion practIcE) programme aimed to design and evaluate enhanced feedback interventions, within a national blood transfusion audit programme, to promote evidence-based guidance and reduce the unnecessary use of blood components. We developed, piloted and refined two feedback interventions, ‘enhanced content’ and ‘enhanced follow-on’ (workstream 1), evaluated the effectiveness and cost-effectiveness of the two feedback interventions compared with standard feedback practice (workstream 2), examined intervention fidelity and contextual influences (workstream 3) and developed general implementation recommendations and tools for other audit and feedback programmes (workstream 4). Design: Interviews, observations and documentary analysis in four purposively sampled hospitals explored contemporary practice and opportunities for strengthening feedback. We developed two interventions: ‘enhanced content’, to improve the clarity and utility of feedback reports, and ‘enhanced follow-on’, to help hospital staff with action-planning (workstream 1). We conducted two linked 2 × 2 factorial cross-sectional cluster-randomised trials within transfusion audits for major surgery and haematological oncology, respectively (workstream 2). We randomised hospital clusters (the organisational level at which hospital transfusion teams operate) to enhanced or standard content or enhanced or standard follow-on. Outcome assessment was masked to assignment. Decision-analytic modelling evaluated the costs, benefits and cost-effectiveness of the feedback interventions in both trials from the perspective of the NHS. A parallel process evaluation used semistructured interviews, documentary analyses and web analytics to assess the fidelity of delivery, receipt and enactment and to identify contextual influences (workstream 3). We explored ways of improving the impact of national audits with their representatives (workstream 4). Setting and participants: All NHS hospital trusts and health boards participating in the National Comparative Audit of Blood Transfusions were invited to take part. Among 189 hospital trusts and health boards screened, 152 hospital clusters participated in the surgical audit. Among 187 hospital trusts and health boards screened, 141 hospital clusters participated in the haematology audit. Interventions: ‘Enhanced content’ aimed to ensure that the content and format of feedback reports were consistent with behaviour change theory and evidence. ‘Enhanced follow-on’ comprised a web-based toolkit and telephone support to facilitate local dissemination, planning and response to feedback. Main outcome measures: Proportions of acceptable transfusions, based on existing evidence and guidance and algorithmically derived from national audit data. Data sources: Trial primary outcomes were derived from manually collected, patient-level audit data. Secondary outcomes included routinely collected data for blood transfusion. Results: With regard to the transfusions in the major surgery audit, 135 (89%) hospital clusters participated from 152 invited. We randomised 69 and 66 clusters to enhanced and standard content, respectively, and 68 and 67 clusters to enhanced and standard follow-on, respectively. We analysed a total of 2222 patient outcomes at 12 months in 54 and 58 (enhanced and standard content, respectively) and 54 and 58 (enhanced and standard follow-on, respectively) hospital clusters. With regard to the haematology audit, 134 hospital clusters (95%) participated from 141 invited. We randomised 66 and 68 clusters to enhanced and standard content, respectively, and 67 clusters to both enhanced and standard follow-on. We analysed a total of 3859 patient outcomes at 12 months in 61 and 61 (enhanced and standard content, respectively) and 63 and 59 (enhanced and standard follow-on) hospital clusters. We found no effect of either of the enhanced feedback interventions in either trial across all outcomes. Incremental enhanced intervention costs ranged from £18 to £248 per site. The enhanced feedback interventions were dominated by the standard intervention in cost-effectiveness analyses. The interventions were delivered as designed and intended, but subsequent local engagement was low. Although the enhancements were generally acceptable, doubts about the credibility of the blood transfusion audits undermined the case for change. Limitations: Limitations included the number of participating clusters; loss to follow-up of trial clusters, reducing statistical power and validity; incomplete audit and cost data contributing to outcome measures; participant self-selection; reporting; missing data related to additional staff activity generated in response to receiving feedback; and recall biases in the process evaluation interviews. Conclusions: The enhanced feedback interventions were acceptable to recipients but were more costly and no more effective than standard feedback in reducing unnecessary use of blood components, and, therefore, should not be recommended on economic grounds. Future work: We have demonstrated the feasibility of embedding ambitious large-scale rigorous research within national audit programmes. Further head-to-head comparisons of different feedback interventions are needed in these programmes to identify cost-effective ways of increasing the impact of the interventions. Trial registration: This trial is registered as ISRCTN15490813. Funding: This project was funded by the National Institute for Health Research (NIHR) Programme Grants for Applied Research programme and will be published in full in Programme Grants for Applied Research; Vol. 10, No. 2. See the NIHR Journals Library website for further project information.
- 21 January 2021
- Published by American Society of Hematology in Blood
- Vol. 137 (3) , 310-322
An epitope-based approach of HLA-matched platelets for transfusion: a noninferiority crossover randomized trial
Platelet transfusion refractoriness results in adverse outcomes and increased health care costs. Managing refractoriness resulting from HLA alloimmunization necessitates the use of HLA antigen–matched platelets but requires a large platelet donor pool and does not guarantee full matching. We report the first randomized, double-blind, noninferiority, crossover trial comparing HLA epitope–matched (HEM) platelets with HLA standard antigen–matched (HSM) platelet transfusions. Alloimmunized, platelet-refractory, thrombocytopenic patients with aplastic anemia, myelodysplastic syndrome, or acute myeloid leukemia were eligible. HEM platelets were selected using HLAMatchMaker epitope (specifically eplet) matching. Patients received up to 8 prophylactic HEM and HSM transfusions provided in random order. The primary outcome was 1-hour posttransfusion platelet count increment (PCI). Forty-nine patients were randomized at 14 UK hospitals. For intention to treat, numbers of evaluable transfusions were 107 and 112 for HEM and HSM methods, respectively. Unadjusted mean PCIs for HEM and HSM methods were 23.9 (standard deviation [SD], 15) and 23.5 (SD, 14.1), respectively (adjusted mean difference, −0.1; 95% confidence interval [CI], −2.9 to 2.8). Because the lower limit of the 95% CI was not greater than the predefined noninferiority limit, the HEM approach was declared noninferior to the HSM approach. There were no differences in secondary outcomes of platelet counts, transfusion requirements, and bleeding events. Adequate 1-hour PCI was more frequently observed, with a mean number of 3.2 epitope mismatches, compared with 5.5 epitope mismatches for inadequate 1-hour increments. For every additional epitope mismatch, the likelihood of an adequate PCI decreased by 15%. Epitope-matched platelets should be considered to support HLA alloimmunized patients. This trial was registered at www.isrctn.com as #ISRCTN23996532.
- 21 January 2021
- Published by American Society of Hematology in Blood
- Vol. 137 (3) , 310-322
An epitope-based approach of HLA-matched platelets for transfusion: a noninferiority crossover randomized trial
Platelet transfusion refractoriness results in adverse outcomes and increased health care costs. Managing refractoriness resulting from HLA alloimmunization necessitates the use of HLA antigen–matched platelets but requires a large platelet donor pool and does not guarantee full matching. We report the first randomized, double-blind, noninferiority, crossover trial comparing HLA epitope–matched (HEM) platelets with HLA standard antigen–matched (HSM) platelet transfusions. Alloimmunized, platelet-refractory, thrombocytopenic patients with aplastic anemia, myelodysplastic syndrome, or acute myeloid leukemia were eligible. HEM platelets were selected using HLAMatchMaker epitope (specifically eplet) matching. Patients received up to 8 prophylactic HEM and HSM transfusions provided in random order. The primary outcome was 1-hour posttransfusion platelet count increment (PCI). Forty-nine patients were randomized at 14 UK hospitals. For intention to treat, numbers of evaluable transfusions were 107 and 112 for HEM and HSM methods, respectively. Unadjusted mean PCIs for HEM and HSM methods were 23.9 (standard deviation [SD], 15) and 23.5 (SD, 14.1), respectively (adjusted mean difference, −0.1; 95% confidence interval [CI], −2.9 to 2.8). Because the lower limit of the 95% CI was not greater than the predefined noninferiority limit, the HEM approach was declared noninferior to the HSM approach. There were no differences in secondary outcomes of platelet counts, transfusion requirements, and bleeding events. Adequate 1-hour PCI was more frequently observed, with a mean number of 3.2 epitope mismatches, compared with 5.5 epitope mismatches for inadequate 1-hour increments. For every additional epitope mismatch, the likelihood of an adequate PCI decreased by 15%. Epitope-matched platelets should be considered to support HLA alloimmunized patients. This trial was registered at www.isrctn.com as #ISRCTN23996532.
- Top Cited Papers
- 17 January 2019
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 380 (3) , 242-251
Randomized Trial of Platelet-Transfusion Thresholds in Neonates
Platelet transfusions are commonly used to prevent bleeding in preterm infants with thrombocytopenia. Data are lacking to provide guidance regarding thresholds for prophylactic platelet transfusions in preterm neonates with severe thrombocytopenia. In this multicenter trial, we randomly assigned infants born at less than 34 weeks of gestation in whom severe thrombocytopenia developed to receive a platelet transfusion at platelet-count thresholds of 50,000 per cubic millimeter (high-threshold group) or 25,000 per cubic millimeter (low-threshold group). Bleeding was documented prospectively with the use of a validated bleeding-assessment tool. The primary outcome was death or new major bleeding within 28 days after randomization. A total of 660 infants (median birth weight, 740 g; and median gestational age, 26.6 weeks) underwent randomization. In the high-threshold group, 90% of the infants (296 of 328 infants) received at least one platelet transfusion, as compared with 53% (177 of 331 infants) in the low-threshold group. A new major bleeding episode or death occurred in 26% of the infants (85 of 324) in the high-threshold group and in 19% (61 of 329) in the low-threshold group (odds ratio, 1.57; 95% confidence interval [CI], 1.06 to 2.32; P=0.02). There was no significant difference between the groups with respect to rates of serious adverse events (25% in the high-threshold group and 22% in the low-threshold group; odds ratio, 1.14; 95% CI, 0.78 to 1.67). Among preterm infants with severe thrombocytopenia, those randomly assigned to receive platelet transfusions at a platelet-count threshold of less than 50,000 per cubic millimeter had a significantly higher rate of death or major bleeding within 28 days after randomization than those in the group that received less than 25,000 per cubic millimeter. (Funded by the National Health Service Blood and Transplant Research and Development Committee and others; Current Controlled Trials number, ISRCTN87736839.)
- 17 January 2019
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 380 (3) , 242-251
Top Cited PapersRandomized Trial of Platelet-Transfusion Thresholds in Neonates
Platelet transfusions are commonly used to prevent bleeding in preterm infants with thrombocytopenia. Data are lacking to provide guidance regarding thresholds for prophylactic platelet transfusions in preterm neonates with severe thrombocytopenia. In this multicenter trial, we randomly assigned infants born at less than 34 weeks of gestation in whom severe thrombocytopenia developed to receive a platelet transfusion at platelet-count thresholds of 50,000 per cubic millimeter (high-threshold group) or 25,000 per cubic millimeter (low-threshold group). Bleeding was documented prospectively with the use of a validated bleeding-assessment tool. The primary outcome was death or new major bleeding within 28 days after randomization. A total of 660 infants (median birth weight, 740 g; and median gestational age, 26.6 weeks) underwent randomization. In the high-threshold group, 90% of the infants (296 of 328 infants) received at least one platelet transfusion, as compared with 53% (177 of 331 infants) in the low-threshold group. A new major bleeding episode or death occurred in 26% of the infants (85 of 324) in the high-threshold group and in 19% (61 of 329) in the low-threshold group (odds ratio, 1.57; 95% confidence interval [CI], 1.06 to 2.32; P=0.02). There was no significant difference between the groups with respect to rates of serious adverse events (25% in the high-threshold group and 22% in the low-threshold group; odds ratio, 1.14; 95% CI, 0.78 to 1.67). Among preterm infants with severe thrombocytopenia, those randomly assigned to receive platelet transfusions at a platelet-count threshold of less than 50,000 per cubic millimeter had a significantly higher rate of death or major bleeding within 28 days after randomization than those in the group that received less than 25,000 per cubic millimeter. (Funded by the National Health Service Blood and Transplant Research and Development Committee and others; Current Controlled Trials number, ISRCTN87736839.)
- Open Access
- 18 June 2018
- Published by Springer Nature in Critical Care
- Vol. 22 (1) , 1-9
Early fibrinogen concentrate therapy for major haemorrhage in trauma (E-FIT 1): results from a UK multi-centre, randomised, double blind, placebo-controlled pilot trial
There is increasing interest in the timely administration of concentrated sources of fibrinogen to patients with major traumatic bleeding. Following evaluation of early cryoprecipitate in the CRYOSTAT 1 trial, we explored the use of fibrinogen concentrate, which may have advantages of more rapid administration in acute haemorrhage. The aims of this pragmatic study were to assess the feasibility of fibrinogen concentrate administration within 45 minutes of hospital admission and to quantify efficacy in maintaining fibrinogen levels ≥ 2 g/L during active haemorrhage. We conducted a blinded, randomised, placebo-controlled trial at five UK major trauma centres with adult trauma patients with active bleeding who required activation of the major haemorrhage protocol. Participants were randomised to standard major haemorrhage therapy plus 6 g of fibrinogen concentrate or placebo. Twenty-seven of 39 participants (69%; 95% CI, 52–83%) across both arms received the study intervention within 45 minutes of admission. There was some evidence of a difference in the proportion of participants with fibrinogen levels ≥ 2 g/L between arms (p = 0.10). Fibrinogen levels in the fibrinogen concentrate (FgC) arm rose by a mean of 0.9 g/L (SD, 0.5) compared with a reduction of 0.2 g/L (SD, 0.5) in the placebo arm and were significantly higher in the FgC arm (p < 0.0001) at 2 hours. Fibrinogen levels were not different at day 7. Transfusion use and thromboembolic events were similar between arms. All-cause mortality at 28 days was 35.5% (95% CI, 23.8–50.8%) overall, with no difference between arms. In this trial, early delivery of fibrinogen concentrate within 45 minutes of admission was not feasible. Although evidence points to a key role for fibrinogen in the treatment of major bleeding, researchers need to recognise the challenges of timely delivery in the emergency setting. Future studies must explore barriers to rapid fibrinogen therapy, focusing on methods to reduce time to randomisation, using ‘off-the-shelf’ fibrinogen therapies (such as extended shelf-life cryoprecipitate held in the emergency department or fibrinogen concentrates with very rapid reconstitution times) and limiting the need for coagulation test-based transfusion triggers. ISRCTN67540073 . Registered on 5 August 2015.
- 18 June 2018
- Published by Springer Nature in Critical Care
- Vol. 22 (1) , 1-9
Open AccessEarly fibrinogen concentrate therapy for major haemorrhage in trauma (E-FIT 1): results from a UK multi-centre, randomised, double blind, placebo-controlled pilot trial
There is increasing interest in the timely administration of concentrated sources of fibrinogen to patients with major traumatic bleeding. Following evaluation of early cryoprecipitate in the CRYOSTAT 1 trial, we explored the use of fibrinogen concentrate, which may have advantages of more rapid administration in acute haemorrhage. The aims of this pragmatic study were to assess the feasibility of fibrinogen concentrate administration within 45 minutes of hospital admission and to quantify efficacy in maintaining fibrinogen levels ≥ 2 g/L during active haemorrhage. We conducted a blinded, randomised, placebo-controlled trial at five UK major trauma centres with adult trauma patients with active bleeding who required activation of the major haemorrhage protocol. Participants were randomised to standard major haemorrhage therapy plus 6 g of fibrinogen concentrate or placebo. Twenty-seven of 39 participants (69%; 95% CI, 52–83%) across both arms received the study intervention within 45 minutes of admission. There was some evidence of a difference in the proportion of participants with fibrinogen levels ≥ 2 g/L between arms (p = 0.10). Fibrinogen levels in the fibrinogen concentrate (FgC) arm rose by a mean of 0.9 g/L (SD, 0.5) compared with a reduction of 0.2 g/L (SD, 0.5) in the placebo arm and were significantly higher in the FgC arm (p < 0.0001) at 2 hours. Fibrinogen levels were not different at day 7. Transfusion use and thromboembolic events were similar between arms. All-cause mortality at 28 days was 35.5% (95% CI, 23.8–50.8%) overall, with no difference between arms. In this trial, early delivery of fibrinogen concentrate within 45 minutes of admission was not feasible. Although evidence points to a key role for fibrinogen in the treatment of major bleeding, researchers need to recognise the challenges of timely delivery in the emergency setting. Future studies must explore barriers to rapid fibrinogen therapy, focusing on methods to reduce time to randomisation, using ‘off-the-shelf’ fibrinogen therapies (such as extended shelf-life cryoprecipitate held in the emergency department or fibrinogen concentrates with very rapid reconstitution times) and limiting the need for coagulation test-based transfusion triggers. ISRCTN67540073 . Registered on 5 August 2015.
- 13 July 2017
- Published by American Society of Hematology in Blood
- Vol. 130 (2) , 214-220
The effect of variation in donor platelet function on transfusion outcome: a semirandomized controlled trial
The effect of variation in platelet function in platelet donors on patient outcome following platelet transfusion is unknown. This trial assessed the hypothesis that platelets collected from donors with highly responsive platelets to agonists in vitro assessed by flow cytometry (high-responder donors) are cleared more quickly from the circulation than those from low-responder donors, resulting in lower platelet count increments following transfusion. This parallel group, semirandomized double-blinded trial was conducted in a single center in the United Kingdom. Eligible patients were those 16 or older with thrombocytopenia secondary to bone marrow failure, requiring prophylactic platelet transfusion. Patients were randomly assigned to receive a platelet donation from a high- or low-responder donor when both were available, or when only 1 type of platelet was available, patients received that. Participants, investigators, and those assessing outcomes were masked to group assignment. The primary end point was the platelet count increment 10 to 90 minutes following transfusion. Analysis was by intention to treat. Fifty-one patients were assigned to receive platelets from low-responder donors, and 49 from high-responder donors (47 of which were randomized and 53 nonrandomized). There was no significant difference in platelet count increment 10 to 90 minutes following transfusion in patients receiving platelets from high-responder (mean, 21.0 × 109/L; 95% confidence interval [CI], 4.9-37.2) or low-responder (mean, 23.3 × 109/L; 95% CI, 7.8-38.9) donors (mean difference, 2.3; 95% CI, −1.1 to 5.7; P = .18). These results support the current policy of not selecting platelet donors on the basis of platelet function for prophylactic platelet transfusion. Publisher9s Note: There is an Inside Blood Commentary on this article in this issue. Key Points There is variation in platelet function between normal individuals, and this function is consistent within the same individual over time. The data from this study suggest that variation in donor platelet function does not affect the outcome of prophylactic transfusion.
- 13 July 2017
- Published by American Society of Hematology in Blood
- Vol. 130 (2) , 214-220
The effect of variation in donor platelet function on transfusion outcome: a semirandomized controlled trial
The effect of variation in platelet function in platelet donors on patient outcome following platelet transfusion is unknown. This trial assessed the hypothesis that platelets collected from donors with highly responsive platelets to agonists in vitro assessed by flow cytometry (high-responder donors) are cleared more quickly from the circulation than those from low-responder donors, resulting in lower platelet count increments following transfusion. This parallel group, semirandomized double-blinded trial was conducted in a single center in the United Kingdom. Eligible patients were those 16 or older with thrombocytopenia secondary to bone marrow failure, requiring prophylactic platelet transfusion. Patients were randomly assigned to receive a platelet donation from a high- or low-responder donor when both were available, or when only 1 type of platelet was available, patients received that. Participants, investigators, and those assessing outcomes were masked to group assignment. The primary end point was the platelet count increment 10 to 90 minutes following transfusion. Analysis was by intention to treat. Fifty-one patients were assigned to receive platelets from low-responder donors, and 49 from high-responder donors (47 of which were randomized and 53 nonrandomized). There was no significant difference in platelet count increment 10 to 90 minutes following transfusion in patients receiving platelets from high-responder (mean, 21.0 × 109/L; 95% confidence interval [CI], 4.9-37.2) or low-responder (mean, 23.3 × 109/L; 95% CI, 7.8-38.9) donors (mean difference, 2.3; 95% CI, −1.1 to 5.7; P = .18). These results support the current policy of not selecting platelet donors on the basis of platelet function for prophylactic platelet transfusion. Publisher9s Note: There is an Inside Blood Commentary on this article in this issue. Key Points There is variation in platelet function between normal individuals, and this function is consistent within the same individual over time. The data from this study suggest that variation in donor platelet function does not affect the outcome of prophylactic transfusion.
- 1 July 2015
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 115 (1) , 76-83
Early cryoprecipitate for major haemorrhage in trauma: a randomised controlled feasibility trial
Low fibrinogen (Fg) concentrations in trauma haemorrhage are associated with poorer outcomes. Cryoprecipitate is the standard source for Fg administration in the UK and USA and is often given in the later stages of transfusion therapy. It is not known whether early cryoprecipitate therapy improves clinical outcomes. The primary aim of this feasibility study was to determine whether it was possible to administer cryoprecipitate, within 90 min of admission to hospital. Secondary aims were to evaluate laboratory measures of Fg and clinical outcomes including thrombotic events, organ failure, length of hospital stay and mortality. This was an unblinded RCT, conducted at two civilian UK major trauma centres of adult trauma patients (age ≥16 yrs), with active bleeding and requiring activation of the major haemorrhage protocol. Participants were randomised to standard major haemorrhage therapy (STANDARD) (n=22), or to standard haemorrhage therapy plus two early pools of cryoprecipitate (CRYO) (n=21). 85% (95% CI: 69-100%) CRYO participants received cryoprecipitate within 90 min, median time 60 min (IQR: 57-76) compared with 108 min (67-147), CRYO and STANDARD arms respectively (P=0.002). Fg concentrations were higher in the CRYO arm and were maintained above 1.8 g litre(-1) at all time-points during active haemorrhage. All-cause mortality at 28 days was not significantly different (P=0.14). Early Fg supplementation using cryoprecipitate is feasible in trauma patients. This study supports the need for a definitive RCT to determine the effect of early Fg supplementation on mortality and other clinical outcomes. ISRCTN55509212.
- 1 July 2015
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 115 (1) , 76-83
Early cryoprecipitate for major haemorrhage in trauma: a randomised controlled feasibility trial
Low fibrinogen (Fg) concentrations in trauma haemorrhage are associated with poorer outcomes. Cryoprecipitate is the standard source for Fg administration in the UK and USA and is often given in the later stages of transfusion therapy. It is not known whether early cryoprecipitate therapy improves clinical outcomes. The primary aim of this feasibility study was to determine whether it was possible to administer cryoprecipitate, within 90 min of admission to hospital. Secondary aims were to evaluate laboratory measures of Fg and clinical outcomes including thrombotic events, organ failure, length of hospital stay and mortality. This was an unblinded RCT, conducted at two civilian UK major trauma centres of adult trauma patients (age ≥16 yrs), with active bleeding and requiring activation of the major haemorrhage protocol. Participants were randomised to standard major haemorrhage therapy (STANDARD) (n=22), or to standard haemorrhage therapy plus two early pools of cryoprecipitate (CRYO) (n=21). 85% (95% CI: 69-100%) CRYO participants received cryoprecipitate within 90 min, median time 60 min (IQR: 57-76) compared with 108 min (67-147), CRYO and STANDARD arms respectively (P=0.002). Fg concentrations were higher in the CRYO arm and were maintained above 1.8 g litre(-1) at all time-points during active haemorrhage. All-cause mortality at 28 days was not significantly different (P=0.14). Early Fg supplementation using cryoprecipitate is feasible in trauma patients. This study supports the need for a definitive RCT to determine the effect of early Fg supplementation on mortality and other clinical outcomes. ISRCTN55509212.
- 15 May 2014
- Published by S. Karger AG in Neonatology
- Vol. 106 (2) , 102-106
Platelets for Neonatal Transfusion - Study 2: A Randomised Controlled Trial to Compare Two Different Platelet Count Thresholds for Prophylactic Platelet Transfusion to Preterm Neonates
Introduction: Neonatal thrombocytopenia is a common and important clinical problem in preterm neonates. A trial assessing clinically relevant outcomes in relation to the different platelet count thresholds used to trigger transfusion has never been undertaken in preterm neonates with severe thrombocytopenia. Objectives: Platelets for Neonatal Transfusion - Study 2 (PlaNeT-2) aims to assess whether a higher prophylactic platelet transfusion threshold is superior to the lower thresholds in current standard practice in reducing the proportion of patients who have a major bleed or die up to study day 28. Methods: PlaNeT-2 is a two-stage, randomised, parallel-group, superiority trial. PlaNet-2 compares clinical outcomes in preterm neonates (<34 weeks' gestation at birth) randomised to receive prophylactic platelet transfusions to maintain platelet counts at or above either 25 × 109/l or 50 × 109/l. The primary outcome measure is the proportion of patients who either die or experience a major bleed up to and including study day 28. A total of 660 infants will be randomised. Results and Conclusions: This trial will help define optimal platelet transfusion support for severely thrombocytopenic preterm neonates by evaluating the risks and benefits of two different prophylactic neonatal platelet transfusion thresholds.
- 15 May 2014
- Published by S. Karger AG in Neonatology
- Vol. 106 (2) , 102-106
Platelets for Neonatal Transfusion - Study 2: A Randomised Controlled Trial to Compare Two Different Platelet Count Thresholds for Prophylactic Platelet Transfusion to Preterm Neonates
Introduction: Neonatal thrombocytopenia is a common and important clinical problem in preterm neonates. A trial assessing clinically relevant outcomes in relation to the different platelet count thresholds used to trigger transfusion has never been undertaken in preterm neonates with severe thrombocytopenia. Objectives: Platelets for Neonatal Transfusion - Study 2 (PlaNeT-2) aims to assess whether a higher prophylactic platelet transfusion threshold is superior to the lower thresholds in current standard practice in reducing the proportion of patients who have a major bleed or die up to study day 28. Methods: PlaNeT-2 is a two-stage, randomised, parallel-group, superiority trial. PlaNet-2 compares clinical outcomes in preterm neonates (<34 weeks' gestation at birth) randomised to receive prophylactic platelet transfusions to maintain platelet counts at or above either 25 × 109/l or 50 × 109/l. The primary outcome measure is the proportion of patients who either die or experience a major bleed up to and including study day 28. A total of 660 infants will be randomised. Results and Conclusions: This trial will help define optimal platelet transfusion support for severely thrombocytopenic preterm neonates by evaluating the risks and benefits of two different prophylactic neonatal platelet transfusion thresholds.