Valery Chernov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Valery Chernov has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
- Marcelino Barboza-Flores
Universidad de Sonora
50 shared publications R. Meléndrez
30 shared publications- Martin Pedroza Montero
Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, México
23 shared publications E. Cruz-Zaragoza
11 shared publicationsS. Gastélum
Departamento de Investigación en Física Universidad de Sonora Hermosillo Sonora 83000 México
10 shared publicationsB. Rogalev
Institute of Geochemistry, POB 4019, Irkutsk 664033, Russia
9 shared publications
Latest Publications
- 4 August 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (8) , 085003
Simplified grading scale for IR breast thermography using as a first-line component of a multi-imaging breast cancer detection strategy
Objective. In this study, we propose a simplified, objective grading scale (mild, moderate, or severe) for infrared breast thermography, intended as a first-line component of a multi-imaging breast cancer detection strategy. The goal was to provide a repeatable, automated alternative to traditional scales, such as the Ville Marie scale, which rely on subjective vascular assessments. Approach. Thermal images of the anterior view of the breasts from 246 asymptomatic volunteers and 54 women with biopsy-confirmed breast cancer were analyzed. Five distinct areas of interest were identified and segmented: the nipples and areolas, the breast tissue, the axillary tails, the axillas, and the submammary region. Breast hyperthermia, which is the difference between the maximal temperature of one breast (without the nipple and areola) and the mean temperature of the contralateral breast, was calculated. To minimize physiological and environmental variability, temperature differences relative to the body surface temperature were calculated. Abnormality and asymmetry levels were quantified using empirical z -scores. To evaluate the global abnormality and asymmetry grading levels of the thermal images, Mahalanobis distances were calculated to assess the joint probability of six thermal variables against an empirical 6-dimensional normal distribution. Main results. Utilizing relative temperatures reduced variability from 1.0 °C – 1.5 °C to 0.4 °C – 0.9 °C compared to absolute measurements for images of asymptomatic women. While the axillary and submammary regions showed no correlation with the presence of cancer, the nipple with areola, breast regions, and breast hyperthermia exhibited significant differences in cases with confirmed cancer. Based on the maximum severity rule, 64.8% of women with cancer presented moderate or severe abnormality grades, whereas 94.7% of asymptomatic women fell within the mild-to-moderate range. Significance. The proposed model is fully objective and suitable for automated processing, thereby reducing the dependence on technician experience. It establishes a clear clinical triage protocol: mild cases indicate no thermographic abnormalities, moderate cases require follow-up within several months, and severe cases should be immediately referred for medical evaluation.
- 4 August 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (8) , 085003
Simplified grading scale for IR breast thermography using as a first-line component of a multi-imaging breast cancer detection strategy
Objective. In this study, we propose a simplified, objective grading scale (mild, moderate, or severe) for infrared breast thermography, intended as a first-line component of a multi-imaging breast cancer detection strategy. The goal was to provide a repeatable, automated alternative to traditional scales, such as the Ville Marie scale, which rely on subjective vascular assessments. Approach. Thermal images of the anterior view of the breasts from 246 asymptomatic volunteers and 54 women with biopsy-confirmed breast cancer were analyzed. Five distinct areas of interest were identified and segmented: the nipples and areolas, the breast tissue, the axillary tails, the axillas, and the submammary region. Breast hyperthermia, which is the difference between the maximal temperature of one breast (without the nipple and areola) and the mean temperature of the contralateral breast, was calculated. To minimize physiological and environmental variability, temperature differences relative to the body surface temperature were calculated. Abnormality and asymmetry levels were quantified using empirical z -scores. To evaluate the global abnormality and asymmetry grading levels of the thermal images, Mahalanobis distances were calculated to assess the joint probability of six thermal variables against an empirical 6-dimensional normal distribution. Main results. Utilizing relative temperatures reduced variability from 1.0 °C – 1.5 °C to 0.4 °C – 0.9 °C compared to absolute measurements for images of asymptomatic women. While the axillary and submammary regions showed no correlation with the presence of cancer, the nipple with areola, breast regions, and breast hyperthermia exhibited significant differences in cases with confirmed cancer. Based on the maximum severity rule, 64.8% of women with cancer presented moderate or severe abnormality grades, whereas 94.7% of asymptomatic women fell within the mild-to-moderate range. Significance. The proposed model is fully objective and suitable for automated processing, thereby reducing the dependence on technician experience. It establishes a clear clinical triage protocol: mild cases indicate no thermographic abnormalities, moderate cases require follow-up within several months, and severe cases should be immediately referred for medical evaluation.
- 15 July 2025
- Published by Elsevier in Journal of Luminescence
- Vol. 286
On the intrinsic defect nature of persistent luminescence in undoped and Eu-doped CaAl2O4
- 15 July 2025
- Published by Elsevier in Journal of Luminescence
- Vol. 286
On the intrinsic defect nature of persistent luminescence in undoped and Eu-doped CaAl2O4
- 29 July 2022
- Published by Wiley in Physica Status Solidi (a)
- Vol. 220 (4)
Thermal Annealing Effect on the Thermoluminescence Properties of Commercial High‐Pressure High‐Temperature Diamond Powders
Diamond applications as thermoluminescence (TL) radiation detectors and dosimeters are extensively studied, especially in synthetic chemical vapor deposition (CVD) and high‐pressure high‐temperature (HPHT) diamonds. Herein, a comparative study of the thermal annealing (TA) effect on the TL properties of four samples of commercial HPHT microdiamonds (MD) powder with a 10–600 μm‐sized range purchased from PlasmaChem is reported. The TL measurements and irradiations are performed using a RISØ TL/OSL reader (β‐radiation, 90Sr/90Y). The TL glow curve analysis and dose behavior are studied with and without TA. The TL glow curves are composed of mainly two broadbands located around room temperature (RT) at 127 °C and 127–400 °C. TA at higher temperatures produces a shift of the maximum TL peak toward the higher‐temperature side. After TA at 1000 °C, the TL repeatability is significantly improved with deviations around 3.4%, showing better TL performance. The TL fading in 24 h immediately after irradiation at RT is observed to be around 49–60% without TA and 18–26% after TA at 1000 °C. The present findings demonstrate that TA at 1000 °C increases the TL performance of the HPHT MD particles as TL dosimeters suitable for ionizing radiation.
- 29 July 2022
- Published by Wiley in Physica Status Solidi (a)
- Vol. 220 (4)
Thermal Annealing Effect on the Thermoluminescence Properties of Commercial High‐Pressure High‐Temperature Diamond Powders
Diamond applications as thermoluminescence (TL) radiation detectors and dosimeters are extensively studied, especially in synthetic chemical vapor deposition (CVD) and high‐pressure high‐temperature (HPHT) diamonds. Herein, a comparative study of the thermal annealing (TA) effect on the TL properties of four samples of commercial HPHT microdiamonds (MD) powder with a 10–600 μm‐sized range purchased from PlasmaChem is reported. The TL measurements and irradiations are performed using a RISØ TL/OSL reader (β‐radiation, 90Sr/90Y). The TL glow curve analysis and dose behavior are studied with and without TA. The TL glow curves are composed of mainly two broadbands located around room temperature (RT) at 127 °C and 127–400 °C. TA at higher temperatures produces a shift of the maximum TL peak toward the higher‐temperature side. After TA at 1000 °C, the TL repeatability is significantly improved with deviations around 3.4%, showing better TL performance. The TL fading in 24 h immediately after irradiation at RT is observed to be around 49–60% without TA and 18–26% after TA at 1000 °C. The present findings demonstrate that TA at 1000 °C increases the TL performance of the HPHT MD particles as TL dosimeters suitable for ionizing radiation.
- 1 July 2021
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
See-through reflective optical elements with embedded wavelike films.
The recently proposed optical elements containing semitransparent wavelike films embedded into the transparent material are investigated. Such optical elements do not distort a wave transmitted through them. Novel optical elements can be fabricated using well-known embossing methods. Their possible applications are discussed. The optical elements containing holographic wavelike films can be used for color holography, for augmented reality wearable glasses, as a beam combiner for head-up displays. The optical elements containing diffuse wavelike films can be used as an alternative for tinted car windows, instead of mirror-glass windows in high-rise buildings, for shop-windows, for one-way privacy windows, for printing images on eyeglasses. The scheme of a waveguide display with a single-layer holographic wavelike films is analyzed. The feasibility of the proposed applications is verified by estimation of the optical elements’ parameters and computer simulation, and measurements conducted on an experimental specimen.
- 1 July 2021
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
See-through reflective optical elements with embedded wavelike films.
The recently proposed optical elements containing semitransparent wavelike films embedded into the transparent material are investigated. Such optical elements do not distort a wave transmitted through them. Novel optical elements can be fabricated using well-known embossing methods. Their possible applications are discussed. The optical elements containing holographic wavelike films can be used for color holography, for augmented reality wearable glasses, as a beam combiner for head-up displays. The optical elements containing diffuse wavelike films can be used as an alternative for tinted car windows, instead of mirror-glass windows in high-rise buildings, for shop-windows, for one-way privacy windows, for printing images on eyeglasses. The scheme of a waveguide display with a single-layer holographic wavelike films is analyzed. The feasibility of the proposed applications is verified by estimation of the optical elements’ parameters and computer simulation, and measurements conducted on an experimental specimen.
- 1 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (13) , 135007
Quantification of the radiosensitization effect of high-Z nanoparticles on photon irradiated cells: combining Monte Carlo simulations and an analytical approach to the local effect model
In vitro experiments show significant reduction in the survival fraction of cells under irradiation treatments assisted with high- Z nanoparticles (NPs). In order to predict the radiosensitization effect of NPs, a modification of the local effect model (LEM), in which the energy deposition from NPs is assessed by Monte Carlo (MC) radiation transport codes, has been employed in the past. In this work, a combined framework that splits the consideration of the radiosensitization effect into two steps is proposed. The first step is the evaluation of the radial dose distribution (RDD) around a single NP ionized by a photon beam with given energy spectrum using MC simulation. Thereafter, an analytical approach based of the LEM and the calculated RDD is used for evaluation of the average dose and the average number of lethal lesions in a cell target due to a set of ionized NPs. The explicit expressions were derived for the case of a spherical cell target and the RDD describing by the power law function. RDDs around gold NPs (GNPs) of different radii were simulated using the MC technique and fitted by a power law function. The fitted RDD and the derived expressions were applied for calculation of the survival curves and relative biological effectiveness of a spherical MDA-MB-231 cell loaded with GNPs and irradiated with monoenergetic photons of 10–150 keV. The proposed framework provides a practical alternative to time-consuming MC simulations, enabling the assessment of the response of cell cultures to an irradiation treatment assisted with NPs for a wide variety of cell geometries, NP distributions and irradiation schemes.
- 1 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (13) , 135007
Quantification of the radiosensitization effect of high-Z nanoparticles on photon irradiated cells: combining Monte Carlo simulations and an analytical approach to the local effect model
In vitro experiments show significant reduction in the survival fraction of cells under irradiation treatments assisted with high- Z nanoparticles (NPs). In order to predict the radiosensitization effect of NPs, a modification of the local effect model (LEM), in which the energy deposition from NPs is assessed by Monte Carlo (MC) radiation transport codes, has been employed in the past. In this work, a combined framework that splits the consideration of the radiosensitization effect into two steps is proposed. The first step is the evaluation of the radial dose distribution (RDD) around a single NP ionized by a photon beam with given energy spectrum using MC simulation. Thereafter, an analytical approach based of the LEM and the calculated RDD is used for evaluation of the average dose and the average number of lethal lesions in a cell target due to a set of ionized NPs. The explicit expressions were derived for the case of a spherical cell target and the RDD describing by the power law function. RDDs around gold NPs (GNPs) of different radii were simulated using the MC technique and fitted by a power law function. The fitted RDD and the derived expressions were applied for calculation of the survival curves and relative biological effectiveness of a spherical MDA-MB-231 cell loaded with GNPs and irradiated with monoenergetic photons of 10–150 keV. The proposed framework provides a practical alternative to time-consuming MC simulations, enabling the assessment of the response of cell cultures to an irradiation treatment assisted with NPs for a wide variety of cell geometries, NP distributions and irradiation schemes.
- 23 December 2019
- Published by Bryansk State Technical University BSTU
- p. 321-324
RESEARCH OF BRIDGE CURRENT AMPLIFIER WITH PI CONTROLLER
A bridge current amplifier with proportional integral control was studied, a circuit diagram was built in the simulation program, and its modeling was carried out. On the basis of the results suggests the possibility of the device model.
- 23 December 2019
- Published by Bryansk State Technical University BSTU
- p. 321-324
RESEARCH OF BRIDGE CURRENT AMPLIFIER WITH PI CONTROLLER
A bridge current amplifier with proportional integral control was studied, a circuit diagram was built in the simulation program, and its modeling was carried out. On the basis of the results suggests the possibility of the device model.
- Open Access
- 16 October 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (30) , 8914
Optical elements containing semitransparent wavelike films: erratum
This erratum corrects errors in Eqs. ( 12 ) and ( 19 ) of the original paper, Appl. Opt. 56, 6146 (2017) [CrossRef] .
- 16 October 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (30) , 8914
Open AccessOptical elements containing semitransparent wavelike films: erratum
This erratum corrects errors in Eqs. ( 12 ) and ( 19 ) of the original paper, Appl. Opt. 56, 6146 (2017) [CrossRef] .
- 11 June 2015
- Published by Wiley in Physica Status Solidi (a)
- Vol. 212 (11) , 2507-2511
Thermoluminescence studies on HPHT diamond crystals exposed to β-irradiation
- 11 June 2015
- Published by Wiley in Physica Status Solidi (a)
- Vol. 212 (11) , 2507-2511
Thermoluminescence studies on HPHT diamond crystals exposed to β-irradiation
- 1 January 2015
- Published by QIRT Council
Using Breast Contour to Generate a Measure of Shape and Size Symmetry
- 1 January 2015
- Published by QIRT Council
Using Breast Contour to Generate a Measure of Shape and Size Symmetry