RSRyan Snodgrass

Ryan Snodgrass

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ryan Snodgrass has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low-frequency cryocoolers are compressed inefficiently

    by Ryan Snodgrass, Vincent Kotsubo, Jens Höhne, Joel Ullom

    Millikelvin refrigerators are enabling tools for many fields of modern science, including quantum information processing. They are typically precooled to 4 K by low-frequency pulse-tube refrigerators, which perform a thermodynamic cycle based on compressing and expanding helium gas. Although the efficiency of these refrigerators is known to be poor, only the loss mechanisms that occur near the cold end have been sufficiently studied and characterized. Here, we combine thermoacoustic calculations with measurements from a commercial pulse-tube refrigerator to determine the efficiency of the generation and transmission of acoustic power, which the refrigerator uses to provide cooling. We find that electrical power consumed by the compressor is converted to acoustic power at a rate of only 0.24, while acoustic power is transmitted through the refrigerator at a comparatively high efficiency of 0.66. The compression process therefore dominates the portion of the system efficiency that is not limited by fluid and material properties. To show that more efficient compression is possible, we also performed measurements on a new metal-bellows compressor that converts electricity to acoustic power at factors up to 0.43. Our results show that low temperatures may be achievable with two or perhaps even three times less electricity.

  • Open Access

    Dynamic acoustic optimization of pulse tube refrigerators for rapid cooldown

    by Ryan Snodgrass, Vincent Kotsubo, Scott Backhaus, Joel Ullom

    Pulse tube refrigerators are a critical enabling technology for many disciplines that require low temperatures. These refrigerators dominate the total power consumption of most modern cryostats, including those that reach millikelvin temperatures using additional cooling stages. In state-of-the-art commercial pulse tube refrigerators, the acoustic coupling between the driving compressor and the refrigerator is fixed and optimized for operation at base temperature. We show that this optimization is incorrect during the cooldown process, which results in wasted power consumption by the compressor and slow cooldown speed. After developing analytic expressions that demonstrate the need for acoustic tuning as a function of temperature, we dynamically optimize the acoustics of a commercial pulse tube refrigerator and show that the cooldown speed can be increased to 1.7 to 3.5 times the original value. Acoustic power measurements show that loss mechanism(s)—and not the capacity of the compressor—limit the maximum cooling available at high temperatures, suggesting that even faster cooldown speeds can be achieved in the future. This work has implications for the accessibility of cryogenic temperatures and the cadence of research in many disciplines such as quantum computing.


  • Open Access

    Simplified detection of Epstein-Barr virus for diagnosis of endemic Burkitt lymphoma

    by Andrea Gardner, Julio Alvarez, Caitlyn Genovese, Ryan Snodgrass, Varun Kopparthy, David Erickson, Ethel Cesarman

    Andrea L Garner, Julio Alvarez, Caitlyn Genovese, Ryan Snodgrass, Varun Kopparthy, David Erickson, Ethel Cesarman; Simplified Detection of Epstein-Barr Virus fo


  • Open Access

    An energy-flexible mechanism for qPCR thermal cycling using shape memory alloys

    by Ryan Snodgrass, Duncan McCloskey, Paul Benecke, David Erickson

    We present a mechanism for thermal cycling that does not require electricity; instead, the device functions as a heat engine and requires only a generic heat source and a shape memory alloy (SMA) spring. The SMA spring mechanically translates to a low-temperature reservoir when heated, and the subsequent cooling of the spring causes translation back to a high-temperature reservoir. The usefulness of the mechanism is displayed by performing the quantitative polymerase chain reaction (qPCR), an important biological assay that requires thermal cycling for amplification of nucleic acids. The ability to perform qPCR with a generic heat source enables a variety of significant health diagnostic tests to be performed in resource limited settings, where electricity access may not be available or reliable. We demonstrate robust thermal cycling using a direct flame, sunlight, and electricity as heat sources, with maximum heating and cooling rates of 4.4 °C s−1 and −2.7 °C s−1, respectively.

  • Holographic diagnosis of lymphoma

    by Varun L. Kopparthy, Ryan Snodgrass, David Erickson


  • A portable device for nucleic acid quantification powered by sunlight, a flame or electricity

    by Ryan Snodgrass, Andrea Gardner, Aggrey Semeere, Varun Lingaiah Kopparthy, Jens Duru, Toby Maurer, Jeffrey Martin, Ethel Cesarman, David Erickson

    A decentralized approach to diagnostics can decrease the time to treatment of infectious diseases in resource-limited settings, yet most modern diagnostic tools require stable electricity and are not portable. Here, we describe a portable device for isothermal nucleic acid quantification that can operate with power from electricity, sunlight or a flame, and that can store heat from intermittent energy sources for operation when electrical power is not available or reliable. We deployed the device in two Ugandan health clinics, where it successfully operated through multiple power outages, with equivalent performance when powered via sunlight or electricity. A direct comparison between the portable device and commercial quantitative polymerase chain reaction machines for samples from 71 Ugandan patients (29 of which were tested in Uganda) for the presence of Kaposi’s sarcoma-associated herpesvirus DNA showed 94% agreement, with the four discordant samples having the lowest concentration of the herpesvirus DNA. The device’s flexibility in power supply provides a needed solution for on-field diagnostics.


  • Open Access

    Solar-thermal complex sample processing for nucleic acid based diagnostics in limited resource settings

    by Abdurrahman Gumus, Syed Ahsan, Belgin Dogan, Li Jiang, Ryan Snodgrass, Andrea Gardner, Zhengda Lu, Kenneth Simpson, David Erickson

    The use of point-of-care (POC) devices in limited resource settings where access to commonly used infrastructure, such as water and electricity, can be restricted represents simultaneously one of the best application fits for POC systems as well as one of the most challenging places to deploy them. Of the many challenges involved in these systems, the preparation and processing of complex samples like stool, vomit, and biopsies are particularly difficult due to the high number and varied nature of mechanical and chemical interferents present in the sample. Previously we have demonstrated the ability to use solar-thermal energy to perform PCR based nucleic acid amplifications. In this work demonstrate how the technique, using similar infrastructure, can also be used to perform solar-thermal based sample processing system for extracting and isolating Vibrio Cholerae nucleic acids from fecal samples. The use of opto-thermal energy enables the use of sunlight to drive thermal lysing reactions in large volumes without the need for external electrical power. Using the system demonstrate the ability to reach a 95°C threshold in less than 5 minutes and maintain a stable sample temperature of +/− 2°C following the ramp up. The system is demonstrated to provide linear results between 104 and 108 CFU/mL when the released nucleic acids were quantified via traditional means. Additionally, we couple the sample processing unit with our previously demonstrated solar-thermal PCR and tablet based detection system to demonstrate very low power sample-in-answer-out detection.


  • Open Access

    KS-Detect – Validation of Solar Thermal PCR for the Diagnosis of Kaposi’s Sarcoma Using Pseudo-Biopsy Samples

    by Ryan Snodgrass, Andrea Gardner, Li Jiang, Cheng Fu, Ethel Cesarman, David Erickson

    Resource-limited settings present unique engineering challenges for medical diagnostics. Diagnosis is often needed for those unable to reach central healthcare systems, making portability and independence from traditional energy infrastructure essential device parameters. In 2014, our group presented a microfluidic device that performed a solar-powered variant of the polymerase chain reaction, which we called solar thermal PCR. In this work, we expand on our previous effort by presenting an integrated, portable, solar thermal PCR system targeted towards the diagnosis of Kaposi’s sarcoma. We call this system KS-Detect, and we now report the system’s performance as a diagnostic tool using pseudo-biopsy samples made from varying concentrations of human lymphoma cell lines positive for the KS herpesvirus (KSHV). KS-Detect achieved 83% sensitivity and 70% specificity at high (≥10%) KSHV+ cell concentrations when diagnosing pseudo-biopsy samples by smartphone image. Using histology, we confirm that our prepared pseudo-biopsies contain similar KSHV+ cell concentrations as human biopsies positive for KS. Through our testing of samples derived from human cell lines, we validate KS-Detect as a viable, portable KS diagnostic tool, and we identify critical engineering considerations for future solar-thermal PCR devices.