Avinash G. Patwardhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Avinash G. Patwardhan has a total of 358 co-authors. Here are the top co-authors by number of shared publications:
Gerard Carandang
Edward Hines Jr. VA Hospital Hines Illinois
34 shared publications- Robert M. Havey
IL, USA
29 shared publications Robert M. Havey
Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital, Hines, IL, USA
28 shared publicationsLeonard I. Voronov
Edward Hines Jr. VA Hospital, Hines, IL, USA; Loyola University Medical Center Dept. of Orthopaedic Surgery, Maywood, IL, USA
24 shared publicationsAlexander J. Ghanayem
Musculoskeletal Biomechanics Laboratory, Edward Hines Jr. VA Hospital, Hines, IL, USA
14 shared publications- Leonard I. Voronov
Loyola University Chicago/Edward Hines Jr. VA Hospital, Hines, IL, US
13 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
Likelihood of Achieving Physiological Mobility After Cervical Disc Arthroplasty—Assessing Physiological Motion Restoration vs Physiological Motion Preservation
Background A previous study investigated the likelihood of cervical artificial discs achieving post-cervical disc arthroplasty (CDA) range of motion (ROM) in the physiological range, defined as 5° to 16°. Here, we delve deeper into the capability of a disc prosthesis to restore physiological motion when the patient is preoperatively hypomobile (ROM < 5°) or hypermobile (ROM > 16°), and capability to preserve physiological mobility when the preoperative ROM falls in the 5° to 16° range. Methods This is a secondary analysis of prospectively collected radiographic data from 131 patients who participated in a 1-level clinical trial of the M6-C (Orthofix) artificial disc. We chose this prosthesis for demonstration purposes due to the availability of pre- and postoperative flexion-extension ROM data on each individual patient. This allowed calculation of the number of implanted levels with preoperative and postoperative flexion-extension ROM in the following motion ranges: hypomobile (ROM < 5°), physiological mobility (ROM: 5°–16°), and hypermobile (ROM > 16°), resulting in a preoperative vs postoperative 3 × 3 mobility matrix. Results Preoperatively, 35 of the 131 implanted levels were hypomobile (ROM: 2.2° ± 1.5°). Of these, physiological ROM was restored to 26 implanted segments by 2 years after CDA (ROM: 7.6° ± 2.0°). A total of 89 of 131 levels had physiological mobility preoperatively (ROM: 9.1° ± 3.3°). Of these, 73 segments preserved their physiological range 2 years after CDA (ROM: 10.2° ± 3.1°). Seven of 131 segments were hypermobile preoperatively (ROM: 18.5° ± 0.9°). Of these, physiological motion was restored to 4 segments by 2 years after CDA (10.9° ± 1.4°). Since the group of patients with preoperative hypermobility was small (n = 7), we combined preoperatively hypo- and hypermobile groups in calculating the restoration rate, resulting in a 2 × 2 mobility matrix. The calculated physiological motion restoration rate was 71% (30/[35 + 7] = 0.71), and preservation rate was 82% (73/89 = 0.82). The combined result was that the prosthesis had a 79% likelihood of yielding physiological mobility at 2 years post-CDA follow-up ([73 + 30]/131). Conclusions The ability to restore and preserve physiological motion are 2 distinct mechanisms that combine to yield physiological motion after CDA. The cervical disc prosthesis analyzed in this study restored physiological motion to 71% of segments with preoperatively nonphysiological (hypomobile plus hypermobile) ROM, while preserving physiological mobility in 82% of segments with preoperative ROM in the physiological range. Clinical Relevance Knowing the likelihood of achieving an ideal postoperative motion outcome for a range of preoperative mobilities can help in guiding patient expectations about CDA and give clinicians additional information to use during implant selection. Level of Evidence 2.
- 1 October 2026
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
Open AccessLikelihood of Achieving Physiological Mobility After Cervical Disc Arthroplasty—Assessing Physiological Motion Restoration vs Physiological Motion Preservation
Background A previous study investigated the likelihood of cervical artificial discs achieving post-cervical disc arthroplasty (CDA) range of motion (ROM) in the physiological range, defined as 5° to 16°. Here, we delve deeper into the capability of a disc prosthesis to restore physiological motion when the patient is preoperatively hypomobile (ROM < 5°) or hypermobile (ROM > 16°), and capability to preserve physiological mobility when the preoperative ROM falls in the 5° to 16° range. Methods This is a secondary analysis of prospectively collected radiographic data from 131 patients who participated in a 1-level clinical trial of the M6-C (Orthofix) artificial disc. We chose this prosthesis for demonstration purposes due to the availability of pre- and postoperative flexion-extension ROM data on each individual patient. This allowed calculation of the number of implanted levels with preoperative and postoperative flexion-extension ROM in the following motion ranges: hypomobile (ROM < 5°), physiological mobility (ROM: 5°–16°), and hypermobile (ROM > 16°), resulting in a preoperative vs postoperative 3 × 3 mobility matrix. Results Preoperatively, 35 of the 131 implanted levels were hypomobile (ROM: 2.2° ± 1.5°). Of these, physiological ROM was restored to 26 implanted segments by 2 years after CDA (ROM: 7.6° ± 2.0°). A total of 89 of 131 levels had physiological mobility preoperatively (ROM: 9.1° ± 3.3°). Of these, 73 segments preserved their physiological range 2 years after CDA (ROM: 10.2° ± 3.1°). Seven of 131 segments were hypermobile preoperatively (ROM: 18.5° ± 0.9°). Of these, physiological motion was restored to 4 segments by 2 years after CDA (10.9° ± 1.4°). Since the group of patients with preoperative hypermobility was small (n = 7), we combined preoperatively hypo- and hypermobile groups in calculating the restoration rate, resulting in a 2 × 2 mobility matrix. The calculated physiological motion restoration rate was 71% (30/[35 + 7] = 0.71), and preservation rate was 82% (73/89 = 0.82). The combined result was that the prosthesis had a 79% likelihood of yielding physiological mobility at 2 years post-CDA follow-up ([73 + 30]/131). Conclusions The ability to restore and preserve physiological motion are 2 distinct mechanisms that combine to yield physiological motion after CDA. The cervical disc prosthesis analyzed in this study restored physiological motion to 71% of segments with preoperatively nonphysiological (hypomobile plus hypermobile) ROM, while preserving physiological mobility in 82% of segments with preoperative ROM in the physiological range. Clinical Relevance Knowing the likelihood of achieving an ideal postoperative motion outcome for a range of preoperative mobilities can help in guiding patient expectations about CDA and give clinicians additional information to use during implant selection. Level of Evidence 2.
- 19 June 2025
- Published by Elsevier in The Spine Journal
- Vol. 25 (12) , 2819-2827
Shear resistance of a posterior lumbar total joint replacement prosthesis
- 19 June 2025
- Published by Elsevier in The Spine Journal
- Vol. 25 (12) , 2819-2827
Shear resistance of a posterior lumbar total joint replacement prosthesis
- 17 March 2025
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 38 (4) , 189-196
Influence of 1-Level Versus 2-Level Cervical Disc Replacements and Disc Prosthesis Design on Motion Outcomes 2-Year Postdisc Arthroplasty in 835 Patients From 4 US IDE Clinical Trials
Study Design/Setting: Analysis of 24-month postoperative flexion-extension range of motion (ROM) data from 1-level and 2-level clinical trials of cervical disc arthroplasty (CDA). Objective: To investigate the influence of (a) 1-level versus 2-level implantations, and (b) prosthesis design, on the proportions of reconstructed segments that achieved physiological mobility (5–16 degrees). Summary of Background Data: The functional goals of CDA are to restore enough ROM to reduce the risk of accelerated adjacent segment degeneration but also limit excessive motion to obtain a biomechanically stable segment. This motion range is termed “physiological” and is defined as 5–16 degrees based on scientific evidence. Methods: We analyzed 24-month post-CDA flexion-extension (FE) ROM data from investigational device exemption studies of artificial disc prostheses approved for both 1-level and 2-level use (Mobi-C, Prestige LP, and Simplify). Only the Prestige LP and Mobi-C trials had data presenting how many implanted levels yielded postoperative ROM of a given degree, and only these 2 discs are included in this analysis. Eight hundred thirty-five patients participated in the 1-level and 2-level clinical trials. We calculated the proportion of implanted levels with postoperative FE-ROM in the following motion ranges: hypomobile (0–4 degrees), physiological (5–16 degrees), and hypermobile (≥17 degrees). Results: On average, two-thirds of implanted levels in these clinical trials yielded FE-ROM of 9.5±3.1 degrees (physiological mobility). Twenty-five percent of the levels moved 2.4±1.2 degrees (hypomobility), and 9% had ROM of 19.8±2.9 degrees (hypermobility). Prestige LP disc had significantly fewer patients exhibiting hypermobility at 24 months in both single-level and 2-level cases than the Mobi-C disc (PP=0.58). Prosthesis design did influence segmental mobility in both 1-level and 2-level constructs. Surgeons may choose to use a specific implant depending on whether a more- or less-constrained design would be best in a specific clinical situation.
- 17 March 2025
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 38 (4) , 189-196
Influence of 1-Level Versus 2-Level Cervical Disc Replacements and Disc Prosthesis Design on Motion Outcomes 2-Year Postdisc Arthroplasty in 835 Patients From 4 US IDE Clinical Trials
Study Design/Setting: Analysis of 24-month postoperative flexion-extension range of motion (ROM) data from 1-level and 2-level clinical trials of cervical disc arthroplasty (CDA). Objective: To investigate the influence of (a) 1-level versus 2-level implantations, and (b) prosthesis design, on the proportions of reconstructed segments that achieved physiological mobility (5–16 degrees). Summary of Background Data: The functional goals of CDA are to restore enough ROM to reduce the risk of accelerated adjacent segment degeneration but also limit excessive motion to obtain a biomechanically stable segment. This motion range is termed “physiological” and is defined as 5–16 degrees based on scientific evidence. Methods: We analyzed 24-month post-CDA flexion-extension (FE) ROM data from investigational device exemption studies of artificial disc prostheses approved for both 1-level and 2-level use (Mobi-C, Prestige LP, and Simplify). Only the Prestige LP and Mobi-C trials had data presenting how many implanted levels yielded postoperative ROM of a given degree, and only these 2 discs are included in this analysis. Eight hundred thirty-five patients participated in the 1-level and 2-level clinical trials. We calculated the proportion of implanted levels with postoperative FE-ROM in the following motion ranges: hypomobile (0–4 degrees), physiological (5–16 degrees), and hypermobile (≥17 degrees). Results: On average, two-thirds of implanted levels in these clinical trials yielded FE-ROM of 9.5±3.1 degrees (physiological mobility). Twenty-five percent of the levels moved 2.4±1.2 degrees (hypomobility), and 9% had ROM of 19.8±2.9 degrees (hypermobility). Prestige LP disc had significantly fewer patients exhibiting hypermobility at 24 months in both single-level and 2-level cases than the Mobi-C disc (PP=0.58). Prosthesis design did influence segmental mobility in both 1-level and 2-level constructs. Surgeons may choose to use a specific implant depending on whether a more- or less-constrained design would be best in a specific clinical situation.
- Open Access
- 6 August 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 19, 100544
Sequential correction of sagittal vertical alignment and lumbar lordosis in adult flatback deformity
- 6 August 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 19, 100544
Open AccessSequential correction of sagittal vertical alignment and lumbar lordosis in adult flatback deformity
- 28 January 2024
- Published by Elsevier in The Spine Journal
- Vol. 24 (6) , 969-978
Prosthesis design and likelihood of achieving physiological range of motion after cervical disc arthroplasty: analysis of range of motion data from 1,173 patients from 7 IDE clinical trials
- 28 January 2024
- Published by Elsevier in The Spine Journal
- Vol. 24 (6) , 969-978
Prosthesis design and likelihood of achieving physiological range of motion after cervical disc arthroplasty: analysis of range of motion data from 1,173 patients from 7 IDE clinical trials
- Open Access
- 15 September 2022
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 12, 100170
Kinematics of a cervical disc prosthesis implanted above or below one- and two-level fusions
- 15 September 2022
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 12, 100170
Open AccessKinematics of a cervical disc prosthesis implanted above or below one- and two-level fusions
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S161-S162
P74. During activities of daily living two-level motion preservation and hybrid constructs may be protective of adjacent segments
- 19 August 2022
- Published by Elsevier in The Spine Journal
- Vol. 22 (9) , S161-S162
P74. During activities of daily living two-level motion preservation and hybrid constructs may be protective of adjacent segments
- 1 October 2021
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 32 (4) , 493-504
Biomechanics of Cervical Disc Arthroplasty Devices
- 1 October 2021
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 32 (4) , 493-504
Biomechanics of Cervical Disc Arthroplasty Devices
- 1 April 2021
- Published by Elsevier in The Spine Journal
- Vol. 21 (4) , 708-719
Loading of the lumbar spine during transition from standing to sitting: effect of fusion versus motion preservation at L4–L5 and L5–S1
- 1 April 2021
- Published by Elsevier in The Spine Journal
- Vol. 21 (4) , 708-719
Loading of the lumbar spine during transition from standing to sitting: effect of fusion versus motion preservation at L4–L5 and L5–S1
- 17 September 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (11) , 2722
Correction to: Prosthesis design influences segmental contribution to total cervical motion after cervical disc arthroplasty
Unfortunately, figures 1 and 2 have been incorrectly published in the original publication. The complete correct figures are given below with the capt
- 17 September 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (11) , 2722
Correction to: Prosthesis design influences segmental contribution to total cervical motion after cervical disc arthroplasty
Unfortunately, figures 1 and 2 have been incorrectly published in the original publication. The complete correct figures are given below with the capt