Yangzi Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yangzi Zheng has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Chi Chiu Chan
School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
1 shared publicationChunliu Zhao
Institute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, China
1 shared publication- Jingyi Yang
Department of Physics & Astronomy University of California Irvine CA 92697 USA
1 shared publication Li Han Chen
Energy Research Institute, Nanyang Technological University, Singapore
1 shared publication- Liyang Shao
Southern University of Science and Technology
1 shared publication Ping Lam So
School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore
1 shared publication
Latest Publications
- 9 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (2) , 322-326
Fiber Optic Fabry–Perot Optofluidic Sensor With a Focused Ion Beam Ablated Microslot For Fast Refractive Index and Magnetic Field Measurement
A compact fiber-optic Fabry-Perot interferometric sensor with an embedded microfluidic channel for static magnetic field measurement is proposed and implemented. Fabrication of the Fabry-Perot structure involved cascading two silica capillary tubes with different inner diameters, followed by milling of a microslot directly on the sidewall of the large inner diameter silica capillary tube, by focused ion beam micromachining. The microslot, together with the hollow structure of the small inner diameter silica capillary tubes forms an open Fabry-Perot cavity to function as a microfluidic channel. The microslot was found to improve the response time of the Fabry-Perot sensor to changes in refractive index (RI) of the cavity. Magnetic fluid was introduced in the Fabry-Perot cavity, thereby, enabling implementation of an optofluidics system for magnetic field measurement. The sensing scheme is based on the magnetic field strength induced RI change of the magnetic fluid which in turn modulates the interference spectrum of the sensor. Wavelength shifts were monitored real time for the continuous measurement of magnetic field strength. The sensor calibration curves with respect to magnetic field were plotted and the sensor exhibits a relative high magnetic field sensitivity of ~418.7 pm/Oe relative to the dip wavelength around 1590 nm.
- 9 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 23 (2) , 322-326
Fiber Optic Fabry–Perot Optofluidic Sensor With a Focused Ion Beam Ablated Microslot For Fast Refractive Index and Magnetic Field Measurement
A compact fiber-optic Fabry-Perot interferometric sensor with an embedded microfluidic channel for static magnetic field measurement is proposed and implemented. Fabrication of the Fabry-Perot structure involved cascading two silica capillary tubes with different inner diameters, followed by milling of a microslot directly on the sidewall of the large inner diameter silica capillary tube, by focused ion beam micromachining. The microslot, together with the hollow structure of the small inner diameter silica capillary tubes forms an open Fabry-Perot cavity to function as a microfluidic channel. The microslot was found to improve the response time of the Fabry-Perot sensor to changes in refractive index (RI) of the cavity. Magnetic fluid was introduced in the Fabry-Perot cavity, thereby, enabling implementation of an optofluidics system for magnetic field measurement. The sensing scheme is based on the magnetic field strength induced RI change of the magnetic fluid which in turn modulates the interference spectrum of the sensor. Wavelength shifts were monitored real time for the continuous measurement of magnetic field strength. The sensor calibration curves with respect to magnetic field were plotted and the sensor exhibits a relative high magnetic field sensitivity of ~418.7 pm/Oe relative to the dip wavelength around 1590 nm.
- Open Access
- 1 January 2013
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2013, 1-4
Relative Humidity Sensor Based on Microfiber Loop Resonator
A novel relative humidity (RH) sensor based on a microfiber loop resonator (MLR) is proposed and experimentally demonstrated. As refractive index of the microfiber in the MLR is modified by environmental humidity, resonant wavelength of the MLR changes with RH level. By detecting this wavelength shift, RH measurement is realized with a linear response sensitivity of 1.8 pm/% RH. The obvious advantage of this technique over others is that no coating of humidity-sensitive material is required.
- 1 January 2013
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2013, 1-4
Open AccessRelative Humidity Sensor Based on Microfiber Loop Resonator
A novel relative humidity (RH) sensor based on a microfiber loop resonator (MLR) is proposed and experimentally demonstrated. As refractive index of the microfiber in the MLR is modified by environmental humidity, resonant wavelength of the MLR changes with RH level. By detecting this wavelength shift, RH measurement is realized with a linear response sensitivity of 1.8 pm/% RH. The obvious advantage of this technique over others is that no coating of humidity-sensitive material is required.