JSJennifer Sahmel

Jennifer Sahmel

*This is an algorithmically generated author record based on publicly available information.

Jennifer Sahmel has a total of 131 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Critical Review of Scientific Data Pertaining to Dermal Exposures to Per‐ and Polyfluoroalkyl Substances (PFAS)

    by Jonathan Heywood, Jennifer Sahmel, Stephanie Tack, Jason Lotter, Shannon H. Gaffney, Scott G. Dotson

    Per‐ and polyfluoroalkyl substances (PFAS) are synthetic highly fluorinated organic compounds that have been used in a variety of industries and commercial and consumer products such as non‐stick cookware, food packaging, medical devices, textiles, firefighting foam, and cosmetics and personal care products (PCPs). Due to concerns regarding the environmental and human health risk of PFAS, numerous studies have been published that investigated topics such as environmental fate, oral toxicology, and potential exposure pathways and routes. Few studies have characterized dermal exposure and uptake potential of PFAS, despite recognition that dermal contact may represent a viable exposure route in certain scenarios. This analysis includes a targeted literature review of studies evaluating PFAS dermal exposure potential, including (1) the potential for transfer and loading onto the skin surface as a result of common dermal exposure pathways, (2) empirical data regarding dermal exposure assessment factors, and (3) estimates of external dermal doses associated with different PFAS exposure sources in addition to any internal dose estimates. Across 37 relevant studies identified, 18 evaluated PFAS exposure from use of cosmetics and PCPs, eight from clothing, six from dust, and five from other scenarios (e.g., site contamination, electronic waste). Estimates for human dermal exposure were generally 100 ng/kg‐bw/day for select scenarios. Studies generally reported that dermal PFAS exposures, when measurable, constituted a small fraction of total PFAS exposure relative to other routes. The toxicological relevance of dermal PFAS exposures at these levels remains unclear.


  • Evaluation of airborne chrysotile concentrations associated with packing replacement during valve repair or overhaul

    by Fian Louie, Joshua R. Maskrey, Deanna E. Badger, Stephanie A. Tack, Shannon H. Gaffney, Jennifer Sahmel

    Asbestos was used in certain packing products for much of the twentieth century. The objective of this study was to characterize exposure from working with and around chrysotile-containing packing during valve repair and overhaul to better understand the exposure potential of career pipefitters and other tradesmen, as well as bystanders and household contacts. Airborne fiber and chrysotile concentrations during packing (20.91-62.77% chrysotile) replacement were measured during standard and nonstandard work tasks involving valve repair and overhaul, cleanup, and clothes handling. Packing replacement was performed on 21 valves by a career engineer at a facility with no mechanical ventilation. Out of 126 air samples, 56 had airborne fiber concentrations above the limit of detection using phase contrast microscopy (PCM) analysis and were subsequently analyzed by transmission electron microscopy (TEM); chrysotile was detected in 21 of the 56 samples. Packing replacement in 16 valves in succession without additional manipulation (such as sanding or compressed air blowout) resulted in a task-based personal average concentration of 0.0378 f/cc, PCM-equivalent asbestos-specific fibers or PCME, while one valve replacement event with compressed air use resulted in an average concentration of 0 f/cc, PCME, and compressed air and sanding combined resulted in an average concentration of 0.0018 f/cc, PCME. Task-based personal sampling during cleanup resulted in concentrations averaging 0.0047 to 0.0162 f/cc, PCME; no chrysotile was detected in task-based close bystander area samples, nor in any samples collected during clothes handling and post-handling cleanup. Regression analysis showed no correlation between PCM concentrations and measured size-fractionated and total airborne particulate matter concentrations. The results indicated that for packing replacement, including work on 16 valves in succession, lack of mechanical ventilation, and nonstandard work practices, all partial-shift and task-based average personal and area airborne fiber concentrations were below the OSHA 8-hr Time-Weighted Average (TWA) Permissible Exposure Limit (PEL) of 0.1 f/cc and 30-min TWA Excursion Limit (EL) for asbestos of 1 f/cc, consistent with previous literature.

  • Excess Absolute Risk: Translating Occupational Measures of Relative Risk to Expected Lifetime Risk Among the General Population—An Example Using Occupational Epidemiological Studies of Cosmetic Talc Miners and Millers and Mesothelioma

    by M. Anthony Cappello, Alexander S. Riordan, Elizabeth A. Best, Hannah C. Mazzotta, Jennifer Sahmel

    Measures of relative risk obtained from occupational epidemiological studies present only part of a risk evaluation needed when conducting public health risk assessments (e.g., among members of the general population). Relative risk alone can often mask the true magnitude of effect and may significantly overestimate the actual risk at the population level, particularly if the background rate of the disease or condition is rare. It is recognized in public health risk assessment and epidemiology that significantly increased relative risk estimates observed in occupational epidemiological studies may not necessarily translate to a significant or excess public health risk. To estimate the expected risk of a given health endpoint among the general population, and thus effectively translate measures of relative risk observed in observational occupational studies, the focus must shift from relative risk models to those of absolute risk. This can be achieved through the epidemiological calculation of excess absolute risk. In this perspective report, the authors discuss the importance of using excess absolute risk calculations in public health risk assessments of rare diseases and demonstrate its application using the body of published occupational epidemiological studies on cosmetic talc miners and millers and mesothelioma risk. By calculating the excess absolute risk among the general population, the argument that cosmetic talc exposure is associated with an increased mesothelioma risk is disputed, and further demonstrates epidemiologically that there is no to negligible (if any) increased risk of mesothelioma from cosmetic talc exposures in the general public.


  • Evaluation of airborne asbestos concentrations associated with the maintenance of brakes on an industrial overhead crane

    by Tyler Ferracini, Sarah Brown, Brooke Simmons, Heather Avens, Shannon Gaffney, Scott Dotson, Jennifer Sahmel

    ObjectivesTo evaluate potential airborne asbestos exposures during brake maintenance and repair activities on a P&H overhead crane, and during subsequent handling of the mechanic's clothing.MethodsPersonal (n = 27) and area (n = 61) airborne fiber concentrations were measured during brake tests, removal, hand sanding, compressed air use, removal and reattachment of chrysotile-containing brake linings, and reinstallation of the brake linings. The mechanic's clothing was used to measure potential exposure during clothes handling.ResultsAll brake linings contained between 19.9% to 52.4% chrysotile asbestos. No amphibole fibers were detected in any bulk or airborne samples. The average full-shift airborne chrysotile concentration was 0.035 f/cc (PCM-equivalent asbestos-specific fibers, or PCME). Average task-based personal air samples collected during brake maintenance, sanding, compressed air use, and brake lining removal tasks ranged from 0 to 0.48 f/cc (PCME). The calculated 30-minute time-weighted average (TWA) airborne chrysotile concentration associated with 5-15 minutes of clothes handling was 0-0.035 f/cc PCME.ConclusionThe results indicated that personal and area TWA fiber concentrations measured during all crane brake maintenance and clothes handling tasks were below the current OSHA 8-h TWA Permissible Exposure Limit for asbestos of 0.1 f/cc. Further, no airborne asbestos fibers were measured during routine brake maintenance tasks following the manufacturer's maintenance manual procedures. All short-term airborne chrysotile concentrations measured during non-routine tasks were below the current 30-minute OSHA excursion limit for asbestos of 1 f/cc. This study adds to the available data regarding chrysotile exposure potential during maintenance on overhead cranes.

  • Accuracy of professional judgments for dermal exposure assessment using deterministic models

    by Jennifer Sahmel, Susan F. Arnold, Gurumurthy Ramachandran

    The accuracy of exposure judgments, particularly for scenarios where only qualitative information is available or a systematic approach is not used, have been evaluated and shown to have a relatively low level of accuracy. This is particularly true for dermal exposures, where less information is generally available compared to inhalation exposures. Relatively few quantitative validation efforts have been performed for scenarios where dermal exposures are of interest. In this study, a series of dermal exposure judgments were collected from 90 volunteer U.S. occupational health practitioners in a workshop format to assess the accuracy of their judgments for three specific scenarios. Accuracy was defined as the ability of the participants to identify the correct reference exposure category, as defined by the quantitative exposure banding categories utilized by the American Industrial Hygiene Association (AIHA). The participants received progressively additional information and training regarding dermal exposure assessments and scenario-specific information during the workshop, and the relative accuracy of their category judgments over time was compared. The results of the study indicated that despite substantial education and training in exposure assessment generally, the practitioners had very little experience in performing dermal exposure assessments and a low level of comfort in performing these assessments. Further, contrary to studies of practitioners performing inhalation exposure assessments demonstrating a trend towards underestimating exposures, participants in this study consistently overestimated the potential for dermal exposure without quantitative data specific to the scenario of interest. Finally, it was found that participants were able to identify the reference or “true” category of dermal exposure acceptability when provided with relevant, scenario-specific dermal and/or surface loading data for use in the assessment process. These results support the need for additional training and education of practitioners in performing dermal exposure assessments. A closer analysis of default loading values used in dermal exposure assessments to evaluate their accuracy relative to real-world or measured dermal loading values, along with consistent improvements in current dermal models, is also needed.


  • Comparison of Hydration Index, Percent Hydration, and Trans-Epidermal Water Loss Measurements for Dermal Exposure and Risk Assessment

    by J Sahmel, G Ramachandran

    Skin hydration and the barrier properties of the stratum corneum have been reported to be influential factors in the potential for retention of solid and semi-solid substances on the skin surface. The measurement of these characteristics of the skin, however, remains relatively uncommon in exposure assessments performed by industrial or occupational hygienists, even when the focus of the assessment is exposure to the skin. This study provides measurements of skin hydration using multiple instruments and multiple relevant skin site locations for comparative analysis. Three different measurement metrics, trans-epidermal water loss (TEWL), hydration index (HI), and percent hydration, were measured for 25 healthy volunteers at two different body locations for comparison: the center of the volar forearm, as previously recommended for interindividual comparison of hydration and barrier property measurements, and also the palmar tip of the index finger. The purpose of the comparative measurements was to allow for comparison between other published baseline volar forearm measurements and the palmar skin, which has not often been quantitatively assessed and reported in the literature, but is a relevant skin surface for sampling of the hands. This comparison will allow for consideration of the potential influence of palmar wipe sampling protocols on TEWL or skin hydration, and for the evaluation of the influence of skin hydration and TEWL on measured dermal transfer values. Collectively, the skin hydration levels and barrier properties at these two different measurement locations were found to be statistically significantly different, and as a result it is suggested that they be measured and recorded separately. Both measurement types and locations are likely to be important for the purposes of establishing skin hydration and health. Volar forearm measurements can also be important for understanding the underlying condition and barrier function of the skin, and palmar index finger measurements are necessary to understand the influence of both TEWL and skin hydration on quantitative dermal loading and transfer of solids and semi-volatile materials.


  • Potential Influence of Skin Hydration and Transepidermal Water Loss on the Dermal Transfer and Loading of Elemental Metallic Lead

    by Jennifer Sahmel, Gurumurthy Ramachandran

    The factors influencing transfer of chemicals or other contaminants to and from the surface of the skin are often poorly understood. Previous research has indicated that environmental conditions, skin hydration, and repeated contacts may all influence the quantity of dermal transfer. The aim of this analysis was to evaluate the influence of skin hydration and condition on quantitative chemical transfer in a series of systematic measurements using human subjects for 5 and 10 repeated contacts. Elemental metallic lead was used as the exemplar test substance for the measurements collected. Skin hydration index (HI) was assessed using a corneometer and skin condition and barrier function were measured using an open-chamber transepidermal water loss (TEWL) instrument. Results indicated that for the palmar surface of the index finger where sampling was conducted, the relative hydration level of the skin was higher for males (n = 6) versus females (n = 4) (mean HI = 4.0 for females; mean HI = 5.5 for males) but this difference was not statistically significant. Overall, the skin hydration level was not significantly associated with dermal loading for either the 5 contact scenario (Pearson correlation = 0.27; R2 = 0.07; P = 0.45) or the 10 contact scenario (Pearson correlation = 0.26; R2 = 0.07; P = 0.47). When the results were stratified by higher versus lower hydration levels (HI = 1–5 versus HI = 5–10), for the higher hydration levels (HI = 5–10; mean HI = 7), there was a moderately positive association between skin hydration and loading, but this was not statistically significant for either the 5 contact scenario (Pearson correlation = 0.75; R2 = 0.56; P = 0.15) or the 10 contact scenario (Pearson correlation = 0.6; R2 = 0.36; P = 0.28). No clear relationship was observed between the lower hydration levels (HI = 1–5) and dermal loading. For the palmar index finger, there was a negative correlation between the TEWL measurements and both the 5 contact (Pearson correlation = −0.45; R2 = 0.2; P = 0.19) and 10 contact (Pearson correlation = −0.3; R2 = 0.09; P = 0.4) scenarios, but this was not statistically significant. The results of this study are consistent with the limited results of other analyses, which have suggested that there may be nuances with respect to the effects of skin hydration on the quantitative dermal transfer to and from the skin, although additional data are needed to better understand these potential differences.

  • Open Access

    Evaluation of Airborne Asbestos Concentrations Associated with the Operation and Maintenance of Brakes and Clutches on Nonautomated Heavy Equipment

    by J. Sahmel, H. Avens, T. Ferracini, A. Banducci, K. Rickabaugh

    This study evaluated the potential for chrysotile asbestos exposure during maintenance and operation of older, nonautomated heavy equipment with chrysotile‐containing brake and clutch linings. Recent reports indicate that such equipment may be in current use in the U.S. and other locations, including developing countries, due to its lower cost and ease of maintenance compared to newer equipment. Personal and area airborne fiber concentrations were measured for cranes with draglines during brake and clutch repair, equipment operation, shop cleanup, and clothes handling of the mechanic’s coveralls over a period of three days. The range of airborne chrysotile concentrations during the complete friction band replacement process, including band removal from the equipment, friction lining replacement, and reinstallation, ranged from 0.0053 to 0.0273 f/cc (phase contrast microscopy‐equivalent or PCME) over 3.3 to 6.2 hours. Additional bench work tasks, including electric wire brushing, hand sanding, riveting, and compressed air use were also performed. Full shift airborne chrysotile concentrations (6.1–8.5 hours) for all combined maintenance activities were 0.0093, 0.0414, and 0.0445 f/cc (PCME), on days 1, 2, and 3, respectively. Personal short‐term samples (14–36 minutes) for lining removal, installation, wire brushing, hand sanding, and compressed air use ranged from nondetect (ND) to 0.238 f/cc (PCME), below the U.S. Occupational Safety and Health Administration's (OSHA's) 30‐minute excursion limit of 1 f/cc. Short‐term samples during crane operation, shop cleanup, and simulated laundry activities with the mechanic’s coveralls ranged from ND to 0.01 f/cc (PCME; 15–36 minutes). The results indicated that full‐shift measured airborne chrysotile concentrations during the brake and clutch maintenance activities evaluated remained below the U.S. 8‐hour time‐weighted average (TWA) permissible exposure limit (PEL) for asbestos of 0.1 f/cc. The results are likely to be relevant to farmers, construction workers, and vehicle maintenance workers historically, as well as today for those who choose to continue using and maintaining such equipment.


  • A pilot study to characterize hand-to-mouth transfer efficiency of organophosphate flame retardants identified in infant products

    by Lauren E. Gloekler, Christy A. Barlow, Brooke Tvermoes, Mark J. La Guardia, Jennifer Sahmel

    This study aimed to determine levels of flame retardants (FRs) in infant products, and to characterize potential for hand-to-mouth transfer efficiency from these products. Select FR concentrations were found in polyurethane foam (PUF) in ten infant products. We examined dermal loading and hand-to-mouth transfer efficiency by simulating handling of two products by participants (n = 9), one of which was handled with and without a fabric covering. Tris (1-chloro-2-propyl) phosphate (TCIPP) was detected in all infant products. The total TCIPP mass transferred to hands was higher for products without covers; however, the relative transfer efficiency (TE) from hands to saliva was higher after handling the product with the cover. Average TCIPP dermal loading was significantly higher without the cover, indicating that these materials may act as a barrier for FR transfer from the PUF to the skin. Estimated highest average daily TCIPP ingestion in infants and children resulting from hand-to-mouth transfer during normal use was 9390 ng/day (1570 ng/kg bw-day) for the uncovered bath product, assuming 100% TE. This study indicates that further research is needed to understand factors that influence individual variability of dermal loading and transfer efficiency, variability of FR concentrations in PUF, and to elucidate the role of fabric coverings on dermal transfer.


  • Influence of repeated contacts on the transfer of elemental metallic lead between compartments in an integrated conceptual model for dermal exposure assessment

    by J. Sahmel, S. Arnold, G. Ramachandran

    Transfer of contaminants to and from the skin surface has been postulated to occur through a number of different pathways and compartments including: object(s)-to-skin, skin-to-skin, skin-to-clothing, skin-to-gloves, air-to-skin, skin-to-lips, and skin-to-saliva. However, many identified transfer pathways have been only minimally examined to determine the potential for measurable transfer. The purpose of this study was to quantitatively evaluate repeated transfer between different compartments using elemental metallic lead (Pb) in the solid form using a series of systematic measurements in human subjects. The results demonstrated that some transfer pathways and compartments are significantly more important than others. Transfer of Pb could not be measured from skin to cotton clothing or skin to laminate countertop surfaces. However, transfer was consistently measured for skin-to-skin and between the skin and the surface of nitrile gloves, suggesting the potential for significant transfer to or from these compartments in real-world exposure scenarios, and the importance of these pathways. With repeated contacts, transfer increased non-linearly between 1 and 5 contacts, but appeared to approach a steady state distribution among the compartments within 10 contacts. Consistent with other studies, relative to 100% transfer for a single contact, the quantitative transfer efficiency decreased with repeated contacts to 29% after 5 contacts and 11–12% after 10 contacts; for skin-to-skin transfer measurements, transfer efficiency after either 5 or 10 contacts was approximately 50% of the single contact transfer. These data are likely to be useful for refining current approaches to modeling of repeated contacts for dermal exposure and risk assessment.