Miquel Nofrarias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Miquel Nofrarias has a total of 834 co-authors. Here are the top co-authors by number of shared publications:
- Ignacio Mateos
Institut de Ciències de l'Espai (CSIC-IEEC), Campus UAB, Carrer de Can Magrans s/n, 08193 Cerdanyola del Vallès, Spain
47 shared publications - Stefano Vitale
Università di Trento
46 shared publications - Juan Rarnos Castro
Universitat Politecnica de Catalunya
42 shared publications - Ferran Gibert
IsardSAT, S.L., Barcelona, Catalonia
41 shared publications - Carlos Fernandez-Sopuerta
Institut de Ciències de l'Espai (ICE Campus UAB CSIC) Carrer de Can Magrans s/n 08193 Cerdanyola del Vallès Spain
39 shared publications - Nikolaos Karnesis
Aristotle University of Thessaloniki
38 shared publications
Latest Publications
- 1 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Enhanced sensitivity in whispering-gallery-mode sensors through mode hybridization
- 1 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Enhanced sensitivity in whispering-gallery-mode sensors through mode hybridization
- 12 December 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (24) , 245006
Antenna for the detection of electromagnetic audio-band disturbances on-board LISA
The LISA mission will be the first observatory to detect gravitational waves from space within the millihertz frequency band. Magnetic forces have an important impact on the instrument’s sensitivity below the millihertz. Hence, monitoring the magnetic environment within each of the LISA spacecrafts is of utmost importance. In this Letter we present the characterization of the coils that were used in LISA Pathfinder (LPF) when operating as magnetic sensors in the audio frequency band. The necessity of implementing this type of magnetometer is presented in order to monitor high frequency magnetic signals from the electronics on-board. We show that the LPF coils have a performance one order of magnitude better than the current requirements set by the LISA mission at the low end of the audio-band frequency. The LPF coils are able to measure a magnetic noise level of 1.45 pT / Hz at 50 Hz and 0.17 pT / Hz at 500 Hz. Additionally, the LPF coils can reach a magnetic noise floor of 0.1 pT / Hz at frequencies above 1 kHz.
- 12 December 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (24) , 245006
Antenna for the detection of electromagnetic audio-band disturbances on-board LISA
The LISA mission will be the first observatory to detect gravitational waves from space within the millihertz frequency band. Magnetic forces have an important impact on the instrument’s sensitivity below the millihertz. Hence, monitoring the magnetic environment within each of the LISA spacecrafts is of utmost importance. In this Letter we present the characterization of the coils that were used in LISA Pathfinder (LPF) when operating as magnetic sensors in the audio frequency band. The necessity of implementing this type of magnetometer is presented in order to monitor high frequency magnetic signals from the electronics on-board. We show that the LPF coils have a performance one order of magnitude better than the current requirements set by the LISA mission at the low end of the audio-band frequency. The LPF coils are able to measure a magnetic noise level of 1.45 pT / Hz at 50 Hz and 0.17 pT / Hz at 500 Hz. Additionally, the LPF coils can reach a magnetic noise floor of 0.1 pT / Hz at frequencies above 1 kHz.
- 18 February 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (7) , 071401
Magnetic-Induced Force Noise in LISA Pathfinder Free-Falling Test Masses
LISA Pathfinder was a mission designed to test key technologies required for gravitational wave detection in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime, which corresponds to the measurement band of interest for future space-borne gravitational wave observatories. Magnetically induced forces couple to the test mass motion, introducing a contribution to the relative acceleration noise between the free-falling test masses. In this Letter we present the first complete estimate of this term of the instrument performance model. Our results set the magnetic-induced acceleration noise during the February 2017 noise run of 0.25_{-0.08}^{+0.15} fm s^{-2}/sqrt[Hz] at 1 mHz and 1.01_{-0.24}^{+0.73} fm s^{-2}/sqrt[Hz] at 0.1 mHz. We also discuss how the nonstationarities of the interplanetary magnetic field can affect these values during extreme space weather conditions.
- 18 February 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (7) , 071401
Magnetic-Induced Force Noise in LISA Pathfinder Free-Falling Test Masses
LISA Pathfinder was a mission designed to test key technologies required for gravitational wave detection in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime, which corresponds to the measurement band of interest for future space-borne gravitational wave observatories. Magnetically induced forces couple to the test mass motion, introducing a contribution to the relative acceleration noise between the free-falling test masses. In this Letter we present the first complete estimate of this term of the instrument performance model. Our results set the magnetic-induced acceleration noise during the February 2017 noise run of 0.25_{-0.08}^{+0.15} fm s^{-2}/sqrt[Hz] at 1 mHz and 1.01_{-0.24}^{+0.73} fm s^{-2}/sqrt[Hz] at 0.1 mHz. We also discuss how the nonstationarities of the interplanetary magnetic field can affect these values during extreme space weather conditions.
- 18 February 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (4)
Precision measurements of the magnetic parameters of LISA Pathfinder test masses
- 18 February 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (4)
Precision measurements of the magnetic parameters of LISA Pathfinder test masses
- Open Access
Resistive-Based Micro-Kelvin Temperature Resolution for Ultra-Stable Space Experiments
High precision temperature measurements are a transversal need in a wide area of physical experiments. Space-borne gravitational wave detectors are a particularly challenging case, requiring both high precision and high stability in temperature measurement. In this contribution, we present a design able to reach 1 in most of the measuring band down to 1 mHz, and reaching 20 at 0.1 mHz. The scheme is based on resistive sensors in a Wheatstone bridge configuration which is AC modulated to minimize the 1/f noise. As a part of our study, we include the design of a test bench able to guarantee the high stability environment required for measurements. We show experimental results characterising both the test bench and the read-out, and discuss potential noise sources that may limit our measurement.Open AccessResistive-Based Micro-Kelvin Temperature Resolution for Ultra-Stable Space Experiments
High precision temperature measurements are a transversal need in a wide area of physical experiments. Space-borne gravitational wave detectors are a particularly challenging case, requiring both high precision and high stability in temperature measurement. In this contribution, we present a design able to reach 1 in most of the measuring band down to 1 mHz, and reaching 20 at 0.1 mHz. The scheme is based on resistive sensors in a Wheatstone bridge configuration which is AC modulated to minimize the 1/f noise. As a part of our study, we include the design of a test bench able to guarantee the high stability environment required for measurements. We show experimental results characterising both the test bench and the read-out, and discuss potential noise sources that may limit our measurement. - Open Access
- 1 June 2021
- Published by Springer Nature in Experimental Astronomy
- Vol. 51 (3) , 1695-1736
Exploring the foundations of the physical universe with space tests of the equivalence principle
We present the scientific motivation for future space tests of the equivalence principle, and in particular the universality of free fall, at the 10− 17 level or better. Two possible mission scenarios, one based on quantum technologies, the other on electrostatic accelerometers, that could reach that goal are briefly discussed. This publication is a White Paper written in the context of the Voyage 2050 ESA Call for White Papers.
- 1 June 2021
- Published by Springer Nature in Experimental Astronomy
- Vol. 51 (3) , 1695-1736
Open AccessExploring the foundations of the physical universe with space tests of the equivalence principle
We present the scientific motivation for future space tests of the equivalence principle, and in particular the universality of free fall, at the 10− 17 level or better. Two possible mission scenarios, one based on quantum technologies, the other on electrostatic accelerometers, that could reach that goal are briefly discussed. This publication is a White Paper written in the context of the Voyage 2050 ESA Call for White Papers.
- 23 November 2020
- Published by Taylor & Francis in Avian Pathology
- Vol. 50 (1) , 98-106
Infectivity and pathobiology of H7N1 and H5N8 high pathogenicity avian influenza viruses for pigeons (Columba livia var. domestica)
Avian influenza (AI) is one of the most important viral diseases in poultry, wildlife and humans. Available data indicate that pigeons play a minimum role in the epidemiology of AI. However, a degree of variation exists in the susceptibility of pigeons to highly pathogenic AI viruses (HPAIVs), especially since the emergence of the goose/Guangdong H5 lineage. Here, the pathogenesis of H5N8 HPAIV in comparison with a H7N1 HPAIV and the role of pigeons in the epidemiology of these viruses were evaluated. Local and urban pigeons (Columba livia var. domestica) were intranasally inoculated with 105 ELD50 of A/goose/Spain/IA17CR02699/2017 (H5N8) or A/Chicken/Italy/5093/1999 (H7N1) and monitored during 14 days. Several pigeons inoculated with H5N8 or H7N1 seroconverted. However, clinical signs, mortality, microscopic lesions and viral antigen were only detected in a local pigeon inoculated with H5N8 HPAIV. This pigeon presented prostration and neurological signs that correlated with the presence of large areas of necrosis and widespread AIV antigen in the central nervous system, indicating that the fatal outcome was associated with neurological dysfunction. Viral RNA in swabs was detected in some pigeons inoculated with H7N1 and H5N8, but it was inconsistent, short-term and at low titres. The present study demonstrates that the majority of pigeons were resistant to H5N8 and H7N1 HPAIVs, despite several pigeons developing asymptomatic infections. The limited viral shedding indicates a minimum role of pigeons as amplifiers of HPAIVs, regardless of the viral lineage, and suggests that this species may represent a low risk for environmental contamination. RESEARCH HIGHLIGHTS
- 23 November 2020
- Published by Taylor & Francis in Avian Pathology
- Vol. 50 (1) , 98-106
Infectivity and pathobiology of H7N1 and H5N8 high pathogenicity avian influenza viruses for pigeons (Columba livia var. domestica)
Avian influenza (AI) is one of the most important viral diseases in poultry, wildlife and humans. Available data indicate that pigeons play a minimum role in the epidemiology of AI. However, a degree of variation exists in the susceptibility of pigeons to highly pathogenic AI viruses (HPAIVs), especially since the emergence of the goose/Guangdong H5 lineage. Here, the pathogenesis of H5N8 HPAIV in comparison with a H7N1 HPAIV and the role of pigeons in the epidemiology of these viruses were evaluated. Local and urban pigeons (Columba livia var. domestica) were intranasally inoculated with 105 ELD50 of A/goose/Spain/IA17CR02699/2017 (H5N8) or A/Chicken/Italy/5093/1999 (H7N1) and monitored during 14 days. Several pigeons inoculated with H5N8 or H7N1 seroconverted. However, clinical signs, mortality, microscopic lesions and viral antigen were only detected in a local pigeon inoculated with H5N8 HPAIV. This pigeon presented prostration and neurological signs that correlated with the presence of large areas of necrosis and widespread AIV antigen in the central nervous system, indicating that the fatal outcome was associated with neurological dysfunction. Viral RNA in swabs was detected in some pigeons inoculated with H7N1 and H5N8, but it was inconsistent, short-term and at low titres. The present study demonstrates that the majority of pigeons were resistant to H5N8 and H7N1 HPAIVs, despite several pigeons developing asymptomatic infections. The limited viral shedding indicates a minimum role of pigeons as amplifiers of HPAIVs, regardless of the viral lineage, and suggests that this species may represent a low risk for environmental contamination. RESEARCH HIGHLIGHTS
- 1 November 2020
- Published by Taylor & Francis in Avian Pathology
- Vol. 49 (6) , 642-657
Experimental infection of domestic geese (Anser anser var. domesticus) with H5N8 Gs/GD and H7N1 highly pathogenic avian influenza viruses
Prior to the emergence of the Asian-origin H5 Goose/Guangdong/1/96 (Gs/GD) lineage, highly pathogenic avian influenza viruses (HPAIV) had rarely caused high mortalities in domestic geese. In 2016/2017 European epidemics, H5N8 Gs/GD clade 2.3.4.4 Group B produced an unprecedented number of outbreaks in waterfowl holdings. In this study, the pathogenesis of H5N8 HPAIV in comparison with H7N1 HPAIV and the role of domestic geese in the epidemiology of these viruses were evaluated. Local and commercial geese (Anser anser var. domesticus) were intranasally inoculated with 105 ELD50 of A/goose/Spain/IA17CR02699/2017 (H5N8) or A/Chicken/Italy/5093/1999 (H7N1) and monitored daily during 15 days. H5N8 was highly virulent to domestic geese, reaching 100% mortality by day 10 post-infection. Systemic microscopic necrotizing lesions associated to widespread AIV-antigen by IHC techniques were detected, being the most severely-affected the central nervous system. High viral loads by qRT-PCR were present in all samples collected: oral and cloacal swabs, plasma and tissues, and moderate levels in pool water. Domestic geese were also susceptible to H7N1 infection, as demonstrated by seroconversion and detection of viral RNA in tissues and plasma in few geese, but all lacked clinical signs. Viral shedding was confirmed in only some geese and restricted to oral route, but levels were high and still detected at the end of the study. Overall, H7N1 present a lower letality and shedding than H5N8 in geese, however the viral shedding indicate that these species could play a role in the epidemiology of Gs/GD and other lineages of HPAIVs. Highlights
- 1 November 2020
- Published by Taylor & Francis in Avian Pathology
- Vol. 49 (6) , 642-657
Experimental infection of domestic geese (Anser anser var. domesticus) with H5N8 Gs/GD and H7N1 highly pathogenic avian influenza viruses
Prior to the emergence of the Asian-origin H5 Goose/Guangdong/1/96 (Gs/GD) lineage, highly pathogenic avian influenza viruses (HPAIV) had rarely caused high mortalities in domestic geese. In 2016/2017 European epidemics, H5N8 Gs/GD clade 2.3.4.4 Group B produced an unprecedented number of outbreaks in waterfowl holdings. In this study, the pathogenesis of H5N8 HPAIV in comparison with H7N1 HPAIV and the role of domestic geese in the epidemiology of these viruses were evaluated. Local and commercial geese (Anser anser var. domesticus) were intranasally inoculated with 105 ELD50 of A/goose/Spain/IA17CR02699/2017 (H5N8) or A/Chicken/Italy/5093/1999 (H7N1) and monitored daily during 15 days. H5N8 was highly virulent to domestic geese, reaching 100% mortality by day 10 post-infection. Systemic microscopic necrotizing lesions associated to widespread AIV-antigen by IHC techniques were detected, being the most severely-affected the central nervous system. High viral loads by qRT-PCR were present in all samples collected: oral and cloacal swabs, plasma and tissues, and moderate levels in pool water. Domestic geese were also susceptible to H7N1 infection, as demonstrated by seroconversion and detection of viral RNA in tissues and plasma in few geese, but all lacked clinical signs. Viral shedding was confirmed in only some geese and restricted to oral route, but levels were high and still detected at the end of the study. Overall, H7N1 present a lower letality and shedding than H5N8 in geese, however the viral shedding indicate that these species could play a role in the epidemiology of Gs/GD and other lineages of HPAIVs. Highlights
- Top Cited PapersOpen Access
- 28 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (22) , 225017
ELGAR—a European Laboratory for Gravitation and Atom-interferometric Research
Gravitational waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportunity for the future of astronomy, the success of which depends upon the decisions being made on existing and new infrastructures. The prospect of combining observations from the future space-based instrument LISA together with third generation ground based detectors will open the way toward multi-band GW astronomy, but will leave the infrasound (0.1–10 Hz) band uncovered. GW detectors based on matter wave interferometry promise to fill such a sensitivity gap. We propose the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an underground infrastructure based on the latest progress in atomic physics, to study space–time and gravitation with the primary goal of detecting GWs in the infrasound band. ELGAR will directly inherit from large research facilities now being built in Europe for the study of large scale atom interferometry and will drive new pan-European synergies from top research centers developing quantum sensors. ELGAR will measure GW radiation in the infrasound band with a peak strain sensitivity of 3.3 × 1 0 − 22 / Hz at 1.7 Hz. The antenna will have an impact on diverse fundamental and applied research fields beyond GW astronomy, including gravitation, general relativity, and geology.
- 28 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (22) , 225017
Top Cited PapersOpen AccessELGAR—a European Laboratory for Gravitation and Atom-interferometric Research
Gravitational waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportunity for the future of astronomy, the success of which depends upon the decisions being made on existing and new infrastructures. The prospect of combining observations from the future space-based instrument LISA together with third generation ground based detectors will open the way toward multi-band GW astronomy, but will leave the infrasound (0.1–10 Hz) band uncovered. GW detectors based on matter wave interferometry promise to fill such a sensitivity gap. We propose the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an underground infrastructure based on the latest progress in atomic physics, to study space–time and gravitation with the primary goal of detecting GWs in the infrasound band. ELGAR will directly inherit from large research facilities now being built in Europe for the study of large scale atom interferometry and will drive new pan-European synergies from top research centers developing quantum sensors. ELGAR will measure GW radiation in the infrasound band with a peak strain sensitivity of 3.3 × 1 0 − 22 / Hz at 1.7 Hz. The antenna will have an impact on diverse fundamental and applied research fields beyond GW astronomy, including gravitation, general relativity, and geology.
- 18 April 2020
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 494 (2) , 3014-3027
Spacecraft and interplanetary contributions to the magnetic environment on-board LISA Pathfinder
LISA Pathfinder (LPF) has been a space-based mission designed to test new technologies that will be required for a gravitational wave observatory in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime (mHz and below), the measurement band of interest for a space-based observatory. The magnetic field can couple to the magnetic susceptibility and remanent magnetic moment from the test masses and disturb them from their geodesic movement. LPF carried on-board a dedicated magnetic measurement subsystem with noise levels of 10 $\rm nT \ Hz^{-1/2}$ from 1 Hz down to 1 mHz. In this paper we report on the magnetic measurements throughout LPF operations. We characterize the magnetic environment within the spacecraft, study the time evolution of the magnetic field and its stability down to 20 μHz, where we measure values around 200 $\rm nT \ Hz^{-1/2}$, and identify two different frequency regimes, one related to the interplanetary magnetic field and the other to the magnetic field originating inside the spacecraft. Finally, we characterize the non-stationary component of the fluctuations of the magnetic field below the mHz and relate them to the dynamics of the solar wind.- 18 April 2020
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 494 (2) , 3014-3027
Spacecraft and interplanetary contributions to the magnetic environment on-board LISA Pathfinder
LISA Pathfinder (LPF) has been a space-based mission designed to test new technologies that will be required for a gravitational wave observatory in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime (mHz and below), the measurement band of interest for a space-based observatory. The magnetic field can couple to the magnetic susceptibility and remanent magnetic moment from the test masses and disturb them from their geodesic movement. LPF carried on-board a dedicated magnetic measurement subsystem with noise levels of 10 $\rm nT \ Hz^{-1/2}$ from 1 Hz down to 1 mHz. In this paper we report on the magnetic measurements throughout LPF operations. We characterize the magnetic environment within the spacecraft, study the time evolution of the magnetic field and its stability down to 20 μHz, where we measure values around 200 $\rm nT \ Hz^{-1/2}$, and identify two different frequency regimes, one related to the interplanetary magnetic field and the other to the magnetic field originating inside the spacecraft. Finally, we characterize the non-stationary component of the fluctuations of the magnetic field below the mHz and relate them to the dynamics of the solar wind.