Borut Fonda
Research Subjects
Research Interests
Borut Fonda has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Nejc Sarabon
S2P, Science to Practice Ltd., Laboratory for Motor Control and Motor Behaviour, Ljubljana, Slovenia; University of Primorska, Andrej Marusic Institute, Department of Health Study, Koper, Slovenia
7 shared publicationsAndrej Panjan
S2P, Science to Practice Ltd., Laboratory for Motor Control and Motor Behavior, Ljubljana, Slovenia
2 shared publicationsMassimo De Nardi
Krioplanet Ltd., Treviglio, Italy
2 shared publications- Nejc Šarabon
Faculty of Health Sciences, University of Primorska, Polje 42, SI-6310 Izola, Slovenia
2 shared publications - Antonio La Torre
Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20133 Milan, Italy
1 shared publication - François-Xavier Li
School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, UK
1 shared publication
Latest Publications
- Open Access
- 22 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1004
The Medial-Lateral Pedal Force Component Correlates with Q-Angle during Steady-State Cycling at Different Workloads and Cadences
Leg movement during cycling is constrained to the pedal/crank path and predominantly occurs in a sagittal plane. Medial-lateral force (FML) applied to the pedals is considered as a waste and does not contribute to the pedaling. The aim of this study was to examine the changes in FML across different cadences and workloads, and to examine the correlation with lateral knee movement (Q-angle). Twenty-two cyclists completed six trials at three workloads (2, 2.5 and 3 W/kg) and three cadences (75, 85, 95 rpm). Forces were recorded from the force pedal mounted to the left side. Absolute and normalized (to the peak total force) FML were compared across conditions and cross-correlation with Q-angle was calculated. Absolute FML was significantly different across cadences and workloads (p < 0.05) with higher absolute FML at higher cadence. There was no significant difference in normalized FML across the three cadences. There was a significant decrease in normalized FML (~10 N) at higher workloads. Statistically significant correlations were found between the FML and Q-angle (R = 0.70–0.77). The results demonstrate the link between the FML and Q-angle in healthy pain-free cyclists during stationary cycling. It has also been observed that smaller normalized magnitude of the FML is present when the force effectiveness is increased.
- 22 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1004
Open AccessThe Medial-Lateral Pedal Force Component Correlates with Q-Angle during Steady-State Cycling at Different Workloads and Cadences
Leg movement during cycling is constrained to the pedal/crank path and predominantly occurs in a sagittal plane. Medial-lateral force (FML) applied to the pedals is considered as a waste and does not contribute to the pedaling. The aim of this study was to examine the changes in FML across different cadences and workloads, and to examine the correlation with lateral knee movement (Q-angle). Twenty-two cyclists completed six trials at three workloads (2, 2.5 and 3 W/kg) and three cadences (75, 85, 95 rpm). Forces were recorded from the force pedal mounted to the left side. Absolute and normalized (to the peak total force) FML were compared across conditions and cross-correlation with Q-angle was calculated. Absolute FML was significantly different across cadences and workloads (p < 0.05) with higher absolute FML at higher cadence. There was no significant difference in normalized FML across the three cadences. There was a significant decrease in normalized FML (~10 N) at higher workloads. Statistically significant correlations were found between the FML and Q-angle (R = 0.70–0.77). The results demonstrate the link between the FML and Q-angle in healthy pain-free cyclists during stationary cycling. It has also been observed that smaller normalized magnitude of the FML is present when the force effectiveness is increased.
- Open Access
- 7 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (2) , 528
3D Knee Loading during Stationary Cycling: A Comprehensive Model Development and Reliability Analysis
The main purpose of this study was to develop and validate a 3D model for calculating knee joint loads during seated cycling. A 3D inverse dynamics approach was used to calculate knee and ankle joint loads using kinematics and kinetics data. For such a model, four kinematics clusters and three pedal markers were used, integrated with a 6-component force/torque pedal dynamometer. Seven subjects performed one five-minute trial on 75% of their maximum power at fixed cadence of 85 rpms. Data from two consecutive samples of the same cycling trial (first and last minute) were used to validate the model with the mean difference between two samples, Cronbach’s alpha, intraclass correlation coefficient (ICC), and p-value. Results showed high ICC (>0.735) and internal consistency (>0.700) with no statistically significant values (p > 0.050) except for crank angle of peak anterior force and peak axial forces at the knee and minimum normal force (p = 0.010) and minimum crank angle (p = 0.010) on the pedal. Further analyses are required to validate the model between days and to test the sensitivity to mechanical constraints.
- 7 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (2) , 528
Open Access3D Knee Loading during Stationary Cycling: A Comprehensive Model Development and Reliability Analysis
The main purpose of this study was to develop and validate a 3D model for calculating knee joint loads during seated cycling. A 3D inverse dynamics approach was used to calculate knee and ankle joint loads using kinematics and kinetics data. For such a model, four kinematics clusters and three pedal markers were used, integrated with a 6-component force/torque pedal dynamometer. Seven subjects performed one five-minute trial on 75% of their maximum power at fixed cadence of 85 rpms. Data from two consecutive samples of the same cycling trial (first and last minute) were used to validate the model with the mean difference between two samples, Cronbach’s alpha, intraclass correlation coefficient (ICC), and p-value. Results showed high ICC (>0.735) and internal consistency (>0.700) with no statistically significant values (p > 0.050) except for crank angle of peak anterior force and peak axial forces at the knee and minimum normal force (p = 0.010) and minimum crank angle (p = 0.010) on the pedal. Further analyses are required to validate the model between days and to test the sensitivity to mechanical constraints.
- 1 December 2015
- Published by Elsevier in Cryobiology
- Vol. 71 (3) , 511-513
Acute effects of whole-body cryotherapy on sit-and-reach amplitude in women and men
- 1 December 2015
- Published by Elsevier in Cryobiology
- Vol. 71 (3) , 511-513
Acute effects of whole-body cryotherapy on sit-and-reach amplitude in women and men
- 1 July 2015
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 10 (5) , 581-586
Effects of Intermittent Lower-Body Negative Pressure on Recovery After Exercise-Induced Muscle Damage
It has been reported in practice that the application of lower-body negative pressure (LBNP) to elite athletes during periods of intense training can help aid recovery.Purpose: To examine the effects of LBNP on biochemical, pain, and performance parameters during a 5-d recovery period after a damaging plyometric-exercise bout.Design: Randomized controlled study.Methods: 24 healthy young female adults were randomly allocated into 2 groups. Before and 1, 24, 48, and 96 h after the damaging exercise for hamstrings (50 drop jumps and 50 leg curls), participants underwent a series of tests (blood samples, pain sensation, countermovement jump, maximal isometric torque production, maximal explosive isometric torque production, and 10-m sprint). After the damaging exercise, the experimental group was exposed to intermittent LBNP therapy daily for 60 min.Results: There was a statistically significant interaction (P < .05) between the experimental and control groups for maximal strength, explosive strength, pain sensation, and vertical jumps (maximal power and force). No statistically significant interaction was present for the biochemical markers, jump height, and 100-m sprint.Conclusions: LBNP therapy could improve recovery by limiting the loss in muscle strength and power and limiting the presence of pain.
- 1 July 2015
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 10 (5) , 581-586
Effects of Intermittent Lower-Body Negative Pressure on Recovery After Exercise-Induced Muscle Damage
It has been reported in practice that the application of lower-body negative pressure (LBNP) to elite athletes during periods of intense training can help aid recovery.Purpose: To examine the effects of LBNP on biochemical, pain, and performance parameters during a 5-d recovery period after a damaging plyometric-exercise bout.Design: Randomized controlled study.Methods: 24 healthy young female adults were randomly allocated into 2 groups. Before and 1, 24, 48, and 96 h after the damaging exercise for hamstrings (50 drop jumps and 50 leg curls), participants underwent a series of tests (blood samples, pain sensation, countermovement jump, maximal isometric torque production, maximal explosive isometric torque production, and 10-m sprint). After the damaging exercise, the experimental group was exposed to intermittent LBNP therapy daily for 60 min.Results: There was a statistically significant interaction (P < .05) between the experimental and control groups for maximal strength, explosive strength, pain sensation, and vertical jumps (maximal power and force). No statistically significant interaction was present for the biochemical markers, jump height, and 100-m sprint.Conclusions: LBNP therapy could improve recovery by limiting the loss in muscle strength and power and limiting the presence of pain.
- 1 May 2014
- Published by Elsevier in Journal of Thermal Biology
- Vol. 42, 52-55
Effects of whole-body cryotherapy duration on thermal and cardio-vascular response
- 1 May 2014
- Published by Elsevier in Journal of Thermal Biology
- Vol. 42, 52-55
Effects of whole-body cryotherapy duration on thermal and cardio-vascular response
- 6 February 2014
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 32 (10) , 940-946
Validity and reliability of different kinematics methods used for bike fitting
The most common bike fitting method to set the seat height is based on the knee angle when the pedal is in its lowest position, i.e. bottom dead centre (BDC). However, there is no consensus on what method should be used to measure the knee angle. Therefore, the first aim of this study was to compare three dynamic methods to each other and against a static method. The second aim was to test the intra-session reliability of the knee angle at BDC measured by dynamic methods. Eleven cyclists performed five 3-min cycling trials; three at different seat heights (25°, 30° and 35° knee angle at BDC according to static measure) and two at preferred seat height. Thirteen infrared cameras (3D), a high-speed camera (2D), and an electrogoniometer were used to measure the knee angle during pedalling, when the pedal was at the BDC. Compared to 3D kinematics, all other methods statistically significantly underestimated the knee angle (P = 0.00; η2 = 0.73). All three dynamic methods have been found to be substantially different compared to the static measure (effect sizes between 0.4 and 0.6). All dynamic methods achieved good intra-session reliability. 2D kinematics is a valid tool for knee angle assessment during bike fitting. However, for higher precision, one should use correction factor by adding 2.2° to the measured value.
- 6 February 2014
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 32 (10) , 940-946
Validity and reliability of different kinematics methods used for bike fitting
The most common bike fitting method to set the seat height is based on the knee angle when the pedal is in its lowest position, i.e. bottom dead centre (BDC). However, there is no consensus on what method should be used to measure the knee angle. Therefore, the first aim of this study was to compare three dynamic methods to each other and against a static method. The second aim was to test the intra-session reliability of the knee angle at BDC measured by dynamic methods. Eleven cyclists performed five 3-min cycling trials; three at different seat heights (25°, 30° and 35° knee angle at BDC according to static measure) and two at preferred seat height. Thirteen infrared cameras (3D), a high-speed camera (2D), and an electrogoniometer were used to measure the knee angle during pedalling, when the pedal was at the BDC. Compared to 3D kinematics, all other methods statistically significantly underestimated the knee angle (P = 0.00; η2 = 0.73). All three dynamic methods have been found to be substantially different compared to the static measure (effect sizes between 0.4 and 0.6). All dynamic methods achieved good intra-session reliability. 2D kinematics is a valid tool for knee angle assessment during bike fitting. However, for higher precision, one should use correction factor by adding 2.2° to the measured value.
- 1 September 2013
- Vol. 12 (3) , 431-8
Functional and neuromuscular changes in the hamstrings after drop jumps and leg curls.
The purpose of this study was to use a holistic approach to investigate changes in jumping performance, kinaesthesia, static balance, isometric strength and fast stepping on spot during a 5-day recovery period, following an acute bout of damaging exercise consisted of drop jumps and leg curls, where specific emphasis was given on the hamstring muscles. Eleven young healthy subjects completed a series of highly intensive damaging exercises for their hamstring muscles. Prior to the exercise, and during the 5-day recovery period, the subjects were tested for biochemical markers (creatine kinase, aspartate aminotransferase, and lactate dehydrogenase), perceived pain sensation, physical performance (squat jump, counter movement jump, maximal frequency leg stamping, maximal isometric torque production and maximally explosive isometric torque production), kinaesthesia (active torque tracking) and static balance. We observed significant decreases in maximal isometric knee flexion torque production, the rate of torque production, and majority of the parameters for vertical jump performance. No alterations were found in kinaesthesia, static balance and fast stepping on spot. The highest drop in performance and increase in perceived pain sensation generally occurred 24 or 48 hours after the exercise. Damaging exercise substantially alters the neuromuscular functions of the hamstring muscles, which is specifically relevant for sports and rehabilitation experts, as the hamstrings are often stretched to significant lengths, in particular when the knee is extended and hip flexed. These findings are practically important for recovery after high-intensity trainings for hamstring muscles. Key PointsHamstring function is significantly reduced following specifically damaging exercise.It fully recovers 120 hours after the exercise.Prevention of exercise-induced muscle damage is cruicial for maintaining normal training regime.
- 1 September 2013
- Vol. 12 (3) , 431-8
Functional and neuromuscular changes in the hamstrings after drop jumps and leg curls.
The purpose of this study was to use a holistic approach to investigate changes in jumping performance, kinaesthesia, static balance, isometric strength and fast stepping on spot during a 5-day recovery period, following an acute bout of damaging exercise consisted of drop jumps and leg curls, where specific emphasis was given on the hamstring muscles. Eleven young healthy subjects completed a series of highly intensive damaging exercises for their hamstring muscles. Prior to the exercise, and during the 5-day recovery period, the subjects were tested for biochemical markers (creatine kinase, aspartate aminotransferase, and lactate dehydrogenase), perceived pain sensation, physical performance (squat jump, counter movement jump, maximal frequency leg stamping, maximal isometric torque production and maximally explosive isometric torque production), kinaesthesia (active torque tracking) and static balance. We observed significant decreases in maximal isometric knee flexion torque production, the rate of torque production, and majority of the parameters for vertical jump performance. No alterations were found in kinaesthesia, static balance and fast stepping on spot. The highest drop in performance and increase in perceived pain sensation generally occurred 24 or 48 hours after the exercise. Damaging exercise substantially alters the neuromuscular functions of the hamstring muscles, which is specifically relevant for sports and rehabilitation experts, as the hamstrings are often stretched to significant lengths, in particular when the knee is extended and hip flexed. These findings are practically important for recovery after high-intensity trainings for hamstring muscles. Key PointsHamstring function is significantly reduced following specifically damaging exercise.It fully recovers 120 hours after the exercise.Prevention of exercise-induced muscle damage is cruicial for maintaining normal training regime.
- 25 April 2013
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 23 (5) , e270-e278
Effects of whole‐body cryotherapy on recovery after hamstring damaging exercise: A crossover study
The purpose of this study was to examine the effects of whole‐body cryotherapy (WBC) on biochemical, pain, and performance parameters during the 5‐day recovery period after damaging exercise for hamstrings. Participants completed a bout of damaging exercise for the hamstring muscles on two separate occasions (control and experimental condition) separated by 10 weeks. During the control condition, subjects received no treatment after the damaging exercise. The experimental condition consisted of WBC everyday during the recovery period. WBC included single 3‐min daily exposures to low temperatures (−140 to −195 °C) in the cryo‐cabin. During the recovery period, subjects were tested for biochemical markers, perceived pain sensation, and physical performance (squat jump, counter movement jump, maximal isometric torque production, and maximally explosive isometric torque production). Majority of the observed variables showed statistically significant time effects (P < 0.05) in control group, which indicates the presence of muscle damage. Significant interaction between the control and WBC condition was evident for the rate of torque development (P < 0.05). Pain measures substantially differed between the WBC and the control condition after the exercise. Results of this study are not completely supportive of the use of WBC for recovery enhancement after strenuous training.
- 25 April 2013
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 23 (5) , e270-e278
Effects of whole‐body cryotherapy on recovery after hamstring damaging exercise: A crossover study
The purpose of this study was to examine the effects of whole‐body cryotherapy (WBC) on biochemical, pain, and performance parameters during the 5‐day recovery period after damaging exercise for hamstrings. Participants completed a bout of damaging exercise for the hamstring muscles on two separate occasions (control and experimental condition) separated by 10 weeks. During the control condition, subjects received no treatment after the damaging exercise. The experimental condition consisted of WBC everyday during the recovery period. WBC included single 3‐min daily exposures to low temperatures (−140 to −195 °C) in the cryo‐cabin. During the recovery period, subjects were tested for biochemical markers, perceived pain sensation, and physical performance (squat jump, counter movement jump, maximal isometric torque production, and maximally explosive isometric torque production). Majority of the observed variables showed statistically significant time effects (P < 0.05) in control group, which indicates the presence of muscle damage. Significant interaction between the control and WBC condition was evident for the rate of torque development (P < 0.05). Pain measures substantially differed between the WBC and the control condition after the exercise. Results of this study are not completely supportive of the use of WBC for recovery enhancement after strenuous training.
- 13 November 2011
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 112 (7) , 2615-2623
Change of muscle activation patterns in uphill cycling of varying slope
In the present study, we quantitatively described and compared lower extremity neuromuscular patterns during level cycling (LC), 10 and 20% uphill cycling (UC). We hypothesized that both the timing and intensity of activity of selected lower extremity muscles will differ between steep (but not moderate slope) UC condition and LC. Twelve trained mountain bikers performed an experimental test with three different cycling conditions (level, 10% slope and 20% slope) with EMG monitoring of eight lower extremity muscles. Significant changes (p < 0.05) in muscle activation timing during 20% UC compared to LC (15° later onset and 39° earlier offset) were observed in m. rectus femoris (RF). Range of activity during 20% UC compared to LC was also significantly (p < 0.05) modified in m. vastus medialis, m. vastus lateralis (8° and 5° shorter) and m. biceps femoris (BF; 17° longer). Furthermore, a reduction of EMG activity level was observed for RF and m. tibialis anterior (TA) during 20% UC compared to LC (25 and 19%; p < 0.05), while the opposite effect was observed for m. gluteus maximus (GM; 12%; p < 0.05). Peak cross-correlation coefficients in all cycling conditions for all muscles were high (all coefficients ≥0.83). We have shown that altered body orientation during steep, but not moderate, slope UC significantly modified the timing and intensity of several lower extremity muscles, the most affected being those that cross the hip joint and TA. The observed modifications in neuromuscular patterns during 20% UC could have a significant effect on lower extremity joint kinetics and cycling efficiency.
- 13 November 2011
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 112 (7) , 2615-2623
Change of muscle activation patterns in uphill cycling of varying slope
In the present study, we quantitatively described and compared lower extremity neuromuscular patterns during level cycling (LC), 10 and 20% uphill cycling (UC). We hypothesized that both the timing and intensity of activity of selected lower extremity muscles will differ between steep (but not moderate slope) UC condition and LC. Twelve trained mountain bikers performed an experimental test with three different cycling conditions (level, 10% slope and 20% slope) with EMG monitoring of eight lower extremity muscles. Significant changes (p < 0.05) in muscle activation timing during 20% UC compared to LC (15° later onset and 39° earlier offset) were observed in m. rectus femoris (RF). Range of activity during 20% UC compared to LC was also significantly (p < 0.05) modified in m. vastus medialis, m. vastus lateralis (8° and 5° shorter) and m. biceps femoris (BF; 17° longer). Furthermore, a reduction of EMG activity level was observed for RF and m. tibialis anterior (TA) during 20% UC compared to LC (25 and 19%; p < 0.05), while the opposite effect was observed for m. gluteus maximus (GM; 12%; p < 0.05). Peak cross-correlation coefficients in all cycling conditions for all muscles were high (all coefficients ≥0.83). We have shown that altered body orientation during steep, but not moderate, slope UC significantly modified the timing and intensity of several lower extremity muscles, the most affected being those that cross the hip joint and TA. The observed modifications in neuromuscular patterns during 20% UC could have a significant effect on lower extremity joint kinetics and cycling efficiency.
- 1 October 2011
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 21 (5) , 854-860
Adjusted saddle position counteracts the modified muscle activation patterns during uphill cycling
- 1 October 2011
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 21 (5) , 854-860
Adjusted saddle position counteracts the modified muscle activation patterns during uphill cycling