Mohammad E. M. Rizk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad E. M. Rizk has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Sayed Abulanwar
Department of Electrical Engineering, Faculty of Engineering, Mansoura University, Mansoura, Egypt
8 shared publications - Abdelhady Ghanem
Electrical Engineering Department, Mansoura University, Mansoura, Egypt
6 shared publications - Farhan Mahmood
Department of Electrical Engineering, University of Engineering and Technology, Lahore, Pakistan
6 shared publications - Matti Lehtonen
School of Electrical Engineering, Aalto University, 02150 Espoo, Finland
4 shared publications - Noor Ul Ain
Department of Electrical Engineering, University of Engineering and Technology, Lahore, Pakistan
3 shared publications - Yoshihiro Baba
Doshisha University, Kyoto, Japan
3 shared publications
Latest Publications
- 28 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A time-domain extension of ground-surface impedance modeling incorporating frequency-dependent soil parameters
- 28 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A time-domain extension of ground-surface impedance modeling incorporating frequency-dependent soil parameters
- 24 February 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 230
Lightning nowcasting using fuzzy logic — A risk assessment framework for resilience of microgrids
- 24 February 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 230
Lightning nowcasting using fuzzy logic — A risk assessment framework for resilience of microgrids
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 5829-5853
Gaussian Process Regression-Based Predictive Fault Location Algorithm for Three-Terminal Lines Using Two-Terminal PMUs
A novel fault location algorithm for three-terminal line (TTTL) via two-terminal phasor measurement units (PMUs) is presented in this paper. A proposed angular compensation factor (ACF) is imposed into the fault loop equations to compensate for the angular displacement between the tie-point and the fault path currents. To predict the ACF, a trained model that uses the Gaussian process regression (GPR) technique is proposed. The regression space is defined by the response variable ACF and four featured variables. Moreover, the training data points mapped ACFs to the four featured variables for different fault scenarios that are defined by the fault type, location, and resistance. Furthermore, training of the data points is performed via GPR, and the results of the root mean squared errors (RMSEs), which are accuracy scores, indicate that the rational quadratic (RQ) and squared exponential (SE) kernel functions have the best estimations. The suggested approach accurately identifies the faulty section and fault class and reduces the computational burden by targeting relevant equations. Extensive case studies are executed with PSCAD/EMTDC and analyzed with MATLAB. The changes in the fault location, inception angles, synchronization errors, signal noise, interphase fault resistance, measurement errors, network configuration and CT saturation were incorporated.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 5829-5853
Gaussian Process Regression-Based Predictive Fault Location Algorithm for Three-Terminal Lines Using Two-Terminal PMUs
A novel fault location algorithm for three-terminal line (TTTL) via two-terminal phasor measurement units (PMUs) is presented in this paper. A proposed angular compensation factor (ACF) is imposed into the fault loop equations to compensate for the angular displacement between the tie-point and the fault path currents. To predict the ACF, a trained model that uses the Gaussian process regression (GPR) technique is proposed. The regression space is defined by the response variable ACF and four featured variables. Moreover, the training data points mapped ACFs to the four featured variables for different fault scenarios that are defined by the fault type, location, and resistance. Furthermore, training of the data points is performed via GPR, and the results of the root mean squared errors (RMSEs), which are accuracy scores, indicate that the rational quadratic (RQ) and squared exponential (SE) kernel functions have the best estimations. The suggested approach accurately identifies the faulty section and fault class and reduces the computational burden by targeting relevant equations. Extensive case studies are executed with PSCAD/EMTDC and analyzed with MATLAB. The changes in the fault location, inception angles, synchronization errors, signal noise, interphase fault resistance, measurement errors, network configuration and CT saturation were incorporated.
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 245-260
Novel Zonal Fault Detection Scheme for DC Wind Farm via Disposition of Surge Arresters in Multipurpose Grounding System
Recently, a prospective new concept of onshore DC wind farms (DCWFs) employing a large-scale grounding system incorporating sheath-connected protective surge devices (PSDs) to ensure protection against probable surges, keep safety of operators, and increase efficacious energy conversion is suggested. This concept involves connecting ungrounded terminal of single-core cable sheath via PSD to conform manufacturers recommendations to avoid thermal stresses. This paper proposes a novel zonal fault detection scheme for DCWF using the installed PSDs as fault location indicators. The proposed scheme relies on distinctive post-fault behavior of PSDs by processing the respective voltages and/or currents captured at each junction by intelligent devices (IDs) at each terminal. PSDs average currents and/or polarities of average voltages at each terminal over 0.5 ms moving window are computed for detecting the possible fault. Vertical cable faults are detected locally at bottom junctions via monitoring locality PSD voltage and core-current. Whereas, an underground cable fault tripping command is determined by a left-side ID via polarity of local horizontal PSD average voltage besides the received digital signals from right-side ID regarding horizontal and vertical PSDs voltages and sheath currents around the junction. Moreover, junction faults are also discriminated via observing peripheral sheath and local ground currents.
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 245-260
Novel Zonal Fault Detection Scheme for DC Wind Farm via Disposition of Surge Arresters in Multipurpose Grounding System
Recently, a prospective new concept of onshore DC wind farms (DCWFs) employing a large-scale grounding system incorporating sheath-connected protective surge devices (PSDs) to ensure protection against probable surges, keep safety of operators, and increase efficacious energy conversion is suggested. This concept involves connecting ungrounded terminal of single-core cable sheath via PSD to conform manufacturers recommendations to avoid thermal stresses. This paper proposes a novel zonal fault detection scheme for DCWF using the installed PSDs as fault location indicators. The proposed scheme relies on distinctive post-fault behavior of PSDs by processing the respective voltages and/or currents captured at each junction by intelligent devices (IDs) at each terminal. PSDs average currents and/or polarities of average voltages at each terminal over 0.5 ms moving window are computed for detecting the possible fault. Vertical cable faults are detected locally at bottom junctions via monitoring locality PSD voltage and core-current. Whereas, an underground cable fault tripping command is determined by a left-side ID via polarity of local horizontal PSD average voltage besides the received digital signals from right-side ID regarding horizontal and vertical PSDs voltages and sheath currents around the junction. Moreover, junction faults are also discriminated via observing peripheral sheath and local ground currents.
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1684-1694
Induced Electromagnetic Fields on Underground Cable Due to Lightning-Struck Wind Tower
In regions having high activity of lightning flashes, it is important to investigate the lightning-induced electromagnetic (EM) transients affecting buried cables, particularly if such buried conductors are extending close to grounded towers, such as wind towers. In this article, the impact of the grounded wind tower, ground conductivity and permittivity, depth of the cable, and its position from the return stroke on the lightning-induced EM fields on the cable sheath are investigated. In addition, the lightning-induced EM fields on the cable sheath are also calculated with the presence of bare-underground wire above the cable as a protection against lightning strikes. The 3-D finite difference time domain method with nonuniform grid technique is implemented for this study. From the results, it is shown that the presence of wind tower increases the magnitude of lightning-induced EM fields on the cable sheath, particularly for close distances between cable and tower. Moreover, the impact of soil permittivity on lightning-induced EM surges becomes significant for low soil conductivity. Also, the impact of cable depth becomes more significant for higher soil conductivity. Furthermore, the bare-underground wire reduces the magnitude of lightning-induced electric field.
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1684-1694
Induced Electromagnetic Fields on Underground Cable Due to Lightning-Struck Wind Tower
In regions having high activity of lightning flashes, it is important to investigate the lightning-induced electromagnetic (EM) transients affecting buried cables, particularly if such buried conductors are extending close to grounded towers, such as wind towers. In this article, the impact of the grounded wind tower, ground conductivity and permittivity, depth of the cable, and its position from the return stroke on the lightning-induced EM fields on the cable sheath are investigated. In addition, the lightning-induced EM fields on the cable sheath are also calculated with the presence of bare-underground wire above the cable as a protection against lightning strikes. The 3-D finite difference time domain method with nonuniform grid technique is implemented for this study. From the results, it is shown that the presence of wind tower increases the magnitude of lightning-induced EM fields on the cable sheath, particularly for close distances between cable and tower. Moreover, the impact of soil permittivity on lightning-induced EM surges becomes significant for low soil conductivity. Also, the impact of cable depth becomes more significant for higher soil conductivity. Furthermore, the bare-underground wire reduces the magnitude of lightning-induced electric field.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (4) , 1152-1161
A Correction to Rusck Expression for the Evaluation of Lightning-Induced Overvoltages for High-Resistivity Ground
The assessment of the indirect lightning performance of overhead distribution lines is important to enhance the reliability of power systems. This article proposes an approximate formula for the evaluation of peak values of lightning-induced voltages in presence of highly resistive grounds. The simulations have been performed using the finite-difference time-domain method, considering the various parameters, such as peak current, return-stroke velocity, and front time, as well as ground parameters, comprising resistivity and permittivity, along with the stroke location and height of the overhead line. The functional relationship between various influential parameters and lightning-induced voltages has been investigated, and, correspondingly, a correction factor is proposed in the well-known Rusck's formula. The curve-fitting technique has been adopted to propose an expression for the correction factor, and the coefficients are determined. The accuracy of the proposed formula has been validated against finite-difference time-domain simulations and the results available in the literature.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (4) , 1152-1161
A Correction to Rusck Expression for the Evaluation of Lightning-Induced Overvoltages for High-Resistivity Ground
The assessment of the indirect lightning performance of overhead distribution lines is important to enhance the reliability of power systems. This article proposes an approximate formula for the evaluation of peak values of lightning-induced voltages in presence of highly resistive grounds. The simulations have been performed using the finite-difference time-domain method, considering the various parameters, such as peak current, return-stroke velocity, and front time, as well as ground parameters, comprising resistivity and permittivity, along with the stroke location and height of the overhead line. The functional relationship between various influential parameters and lightning-induced voltages has been investigated, and, correspondingly, a correction factor is proposed in the well-known Rusck's formula. The curve-fitting technique has been adopted to propose an expression for the correction factor, and the coefficients are determined. The accuracy of the proposed formula has been validated against finite-difference time-domain simulations and the results available in the literature.
- Open Access
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 53940-53953
Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters
Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations.
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 53940-53953
Open AccessSensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters
Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2757-2765
A Prediction Model For Lightning-Induced Overvoltages Over Lossy Ground Using Gaussian Process Regression
The accurate assessment of lightning-induced over-voltages is essential for proper insulation coordination studies. In this paper, a novel machine learning based Gaussian process regression model is developed for the prediction of lightning-induced over-voltages considering wide range of ground resistivity and permittivity. The lightning-induced over-voltages have been computed using two-dimensional finite-difference time-domain technique associated with Agrawal field to line coupling model. To account for the input space variability, seven predictor variables namely: resistivity, permittivity, return stroke velocity, distance from flashpoint, return stroke peak current, front-time, and height of an overhead line are considered to determine the response variable, that is, lightning-induced over-voltages. Accordingly, the training of the Gaussian process regression model is carried out using lightning-induced over-voltages obtained from two-dimensional finite-difference time-domain technique for both first and the subsequent strokes. The estimation accuracy of model is appraised using root mean squared error indicating that the exponential kernel function has the least error than other kernel types for describing the covariance. The predictive performance is evaluated by corroborating the predictions from the model against the random test cases generated from two-dimensional finite-difference time-domain technique. The predicted results showed a good agreement with those obtained from finite-difference time-domain technique.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2757-2765
A Prediction Model For Lightning-Induced Overvoltages Over Lossy Ground Using Gaussian Process Regression
The accurate assessment of lightning-induced over-voltages is essential for proper insulation coordination studies. In this paper, a novel machine learning based Gaussian process regression model is developed for the prediction of lightning-induced over-voltages considering wide range of ground resistivity and permittivity. The lightning-induced over-voltages have been computed using two-dimensional finite-difference time-domain technique associated with Agrawal field to line coupling model. To account for the input space variability, seven predictor variables namely: resistivity, permittivity, return stroke velocity, distance from flashpoint, return stroke peak current, front-time, and height of an overhead line are considered to determine the response variable, that is, lightning-induced over-voltages. Accordingly, the training of the Gaussian process regression model is carried out using lightning-induced over-voltages obtained from two-dimensional finite-difference time-domain technique for both first and the subsequent strokes. The estimation accuracy of model is appraised using root mean squared error indicating that the exponential kernel function has the least error than other kernel types for describing the covariance. The predictive performance is evaluated by corroborating the predictions from the model against the random test cases generated from two-dimensional finite-difference time-domain technique. The predicted results showed a good agreement with those obtained from finite-difference time-domain technique.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2464-2473
Computation of Lightning-Induced Voltages Considering Ground Impedance of Multi-Conductor Line for Lossy Dispersive Soil
Soil conductivity and permittivity have a substantial influence on lightning-electromagnetic transients in power system. In this paper, lightning-induced voltages are computed on a multi-conductor overhead line due to nearby first and subsequent return strokes. Besides, this study considers the longitudinal complex inductance of the line due to the penetration depth of electromagnetic fields through finitely conducting ground as well as the frequency dependent soil parameters using the finite-difference time-domain method. Various case studies in light of variations of return stroke velocity, line height, and soil conductivity are explored for thoughtful investigations. The obtained results reveal that the influence of this complex inductance on peak values of lightning induced voltages changes with varying the return stroke velocity. Also, the frequency dependence of soil parameters markedly impacts the computed lightning-induced voltages particularly for poor soil conductivity.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2464-2473
Computation of Lightning-Induced Voltages Considering Ground Impedance of Multi-Conductor Line for Lossy Dispersive Soil
Soil conductivity and permittivity have a substantial influence on lightning-electromagnetic transients in power system. In this paper, lightning-induced voltages are computed on a multi-conductor overhead line due to nearby first and subsequent return strokes. Besides, this study considers the longitudinal complex inductance of the line due to the penetration depth of electromagnetic fields through finitely conducting ground as well as the frequency dependent soil parameters using the finite-difference time-domain method. Various case studies in light of variations of return stroke velocity, line height, and soil conductivity are explored for thoughtful investigations. The obtained results reveal that the influence of this complex inductance on peak values of lightning induced voltages changes with varying the return stroke velocity. Also, the frequency dependence of soil parameters markedly impacts the computed lightning-induced voltages particularly for poor soil conductivity.