Jianhua Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jianhua Wang has a total of 282 co-authors. Here are the top co-authors by number of shared publications:
- Yingsan Geng
State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xian Jiaotong University, Xian, China
90 shared publications - Zhiyuan Liu
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
58 shared publications - Jing Yan
Xi’an Jiaotong University
30 shared publications - Bin Xiang
State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xian Jiaotong University, Xian, China
27 shared publications - Yanxin Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xian Jiaotong University, Xian, China
25 shared publications Yingsan Geng
Department of Electrical Engineering, State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
20 shared publications
Latest Publications
- 5 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-11
Arc Behavior and Surface Evolution Under Targeted Current Conditioning
The conditioning of vacuum interrupters (VIs) essentially involves a secondary metallurgical effect on contact surfaces induced by arc energy. The achievement of the following two objectives determines the final metallographic characteristics and conditioning efficacy: precise localization of insulation-weak areas on the contact surfaces to achieve uniform distribution of arc energy, and accurate regulation of energy deposition within the targeted regions to beneficially modify the contact surface. Since the breakdown conditions of the contact gap and the energy-injection conditions are coupled in conventional single-power-source modes, it is difficult to independently and effectively adjust the corresponding spatial and temporal parameters, thereby constraining further exploration of conditioning methodologies. To address the above issues, this article proposes a targeted current conditioning (TCC) technology that accurately locates and breaks down insulation weak spots using low-energy, high-voltage pulses. Subsequently, conditioning is realized by applying a high-current arc with specific amplitude and time constant to the identified region. This method overcomes the bottlenecks of uncontrollable arc energy and uneven energy distribution during conditioning, which can significantly enhance the insulation performance of VIs. Building on this foundation, this study uses high-speed imaging to observe the arc’s transfer characteristics and spatial distribution, which are correlated with field-emission characteristics to analyze the evolution of electrode surface properties. The main objectives of this study are: validating the feasibility of localization during targeted conditioning, revealing the intrinsic mechanisms underlying the evolution of surface features, and performing an in-depth investigation into the physical mechanisms responsible for insulation improvement under targeted current action.
- 5 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-11
Arc Behavior and Surface Evolution Under Targeted Current Conditioning
The conditioning of vacuum interrupters (VIs) essentially involves a secondary metallurgical effect on contact surfaces induced by arc energy. The achievement of the following two objectives determines the final metallographic characteristics and conditioning efficacy: precise localization of insulation-weak areas on the contact surfaces to achieve uniform distribution of arc energy, and accurate regulation of energy deposition within the targeted regions to beneficially modify the contact surface. Since the breakdown conditions of the contact gap and the energy-injection conditions are coupled in conventional single-power-source modes, it is difficult to independently and effectively adjust the corresponding spatial and temporal parameters, thereby constraining further exploration of conditioning methodologies. To address the above issues, this article proposes a targeted current conditioning (TCC) technology that accurately locates and breaks down insulation weak spots using low-energy, high-voltage pulses. Subsequently, conditioning is realized by applying a high-current arc with specific amplitude and time constant to the identified region. This method overcomes the bottlenecks of uncontrollable arc energy and uneven energy distribution during conditioning, which can significantly enhance the insulation performance of VIs. Building on this foundation, this study uses high-speed imaging to observe the arc’s transfer characteristics and spatial distribution, which are correlated with field-emission characteristics to analyze the evolution of electrode surface properties. The main objectives of this study are: validating the feasibility of localization during targeted conditioning, revealing the intrinsic mechanisms underlying the evolution of surface features, and performing an in-depth investigation into the physical mechanisms responsible for insulation improvement under targeted current action.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (7) , 6337-6348
A Two-Level Multisensor Fusion Network With Incremental Learning for Insulation Defect Diagnosis in Gas-Insulated Switchgear
Gas-insulated switchgear (GIS) insulation defect diagnosis faces persistent challenges due to heterogeneous multisensor signals, the lack of structured fusion across sensor types, and severe catastrophic forgetting under source-free streaming conditions. To address these issues, this article proposes a two-level fusion multisensor network with incremental learning (TFMNIL) for on-site diagnosis. Unlike conventional one-stage fusion strategies, the proposed framework separates multisensor fusion into channel-level fusion of homogeneous sensors to preserve consistent physical characteristics, and feature-level fusion of heterogeneous sensors to reduce cross-modal semantic discrepancies and redundancy. To support continual adaptation under evolving operating conditions, an incremental domain adaptation strategy is further developed. It integrates dynamic prototype updating to compensate for feature drift with classifier-weight–anchored cross-domain contrastive alignment, enabling stable class-level supervision without access to source data. Experiments on large-scale real-world multisensor GIS datasets show that TFMNIL achieves a diagnostic accuracy of 95.86% and maintains strong adaptability to newly emerging fault types in practical on-site scenarios.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (7) , 6337-6348
A Two-Level Multisensor Fusion Network With Incremental Learning for Insulation Defect Diagnosis in Gas-Insulated Switchgear
Gas-insulated switchgear (GIS) insulation defect diagnosis faces persistent challenges due to heterogeneous multisensor signals, the lack of structured fusion across sensor types, and severe catastrophic forgetting under source-free streaming conditions. To address these issues, this article proposes a two-level fusion multisensor network with incremental learning (TFMNIL) for on-site diagnosis. Unlike conventional one-stage fusion strategies, the proposed framework separates multisensor fusion into channel-level fusion of homogeneous sensors to preserve consistent physical characteristics, and feature-level fusion of heterogeneous sensors to reduce cross-modal semantic discrepancies and redundancy. To support continual adaptation under evolving operating conditions, an incremental domain adaptation strategy is further developed. It integrates dynamic prototype updating to compensate for feature drift with classifier-weight–anchored cross-domain contrastive alignment, enabling stable class-level supervision without access to source data. Experiments on large-scale real-world multisensor GIS datasets show that TFMNIL achieves a diagnostic accuracy of 95.86% and maintains strong adaptability to newly emerging fault types in practical on-site scenarios.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Electrochemical Coupled Federated Multisensor Measurement Framework for GIS Insulation Fault Detection and Diagnosis
Accurate insulation fault diagnosis in gas-insulated substations (GISs) is hindered by the limited sensitivity of single-sensor systems and the heterogeneity of field data. To enhance both measurement sensitivity and detection reliability of GIS insulation faults, this paper proposes an electro-chemical coupled federated multi-sensor fusion network (FMSFN) that integrates multi-modal sensing and distributed analytics into a unified measurement system. The proposed framework introduces a novel electro-chemical coupled detection mechanism that jointly captures electrical discharge characteristics and gas-chemical decomposition signatures to enable homogeneous and heterogeneous feature fusion under a federated cloud–edge architecture. This design supports distributed, privacy-preserving fault diagnosis across multiple users and devices. Within the proposed FMSFN, a deep fusion network equipped with an adaptive hybrid attention module is employed to strengthen cross-sensor feature interaction and enable dynamic modality-aware weighting, while a federated hierarchical optimization strategy with personalized updates and noise-aware aggregation ensures stable and robust convergence under non-IID data distributions. Experimental results demonstrate that the FMSFN achieves 97.23% accuracy and a 96.83% macro F1-score, consistently outperforming existing single-sensor and centralized diagnostic models. These results confirm the robustness, scalability, and practical applicability of the proposed electrochemical-coupled measurement system, which provides a scalable instrumentation approach for GIS insulation fault diagnosis.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Electrochemical Coupled Federated Multisensor Measurement Framework for GIS Insulation Fault Detection and Diagnosis
Accurate insulation fault diagnosis in gas-insulated substations (GISs) is hindered by the limited sensitivity of single-sensor systems and the heterogeneity of field data. To enhance both measurement sensitivity and detection reliability of GIS insulation faults, this paper proposes an electro-chemical coupled federated multi-sensor fusion network (FMSFN) that integrates multi-modal sensing and distributed analytics into a unified measurement system. The proposed framework introduces a novel electro-chemical coupled detection mechanism that jointly captures electrical discharge characteristics and gas-chemical decomposition signatures to enable homogeneous and heterogeneous feature fusion under a federated cloud–edge architecture. This design supports distributed, privacy-preserving fault diagnosis across multiple users and devices. Within the proposed FMSFN, a deep fusion network equipped with an adaptive hybrid attention module is employed to strengthen cross-sensor feature interaction and enable dynamic modality-aware weighting, while a federated hierarchical optimization strategy with personalized updates and noise-aware aggregation ensures stable and robust convergence under non-IID data distributions. Experimental results demonstrate that the FMSFN achieves 97.23% accuracy and a 96.83% macro F1-score, consistently outperforming existing single-sensor and centralized diagnostic models. These results confirm the robustness, scalability, and practical applicability of the proposed electrochemical-coupled measurement system, which provides a scalable instrumentation approach for GIS insulation fault diagnosis.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
A Multimodal Large Language Model Framework for Partial Discharge Condition Assessment in Gas-Insulated Switchgear
Artificial intelligence–enabled partial discharge (PD) condition assessment in gas-insulated switchgear (GIS) is essential for ensuring reliable operation of power equipment. However, existing methods face significant challenges in dealing with heterogeneous signal modalities, limited labeled data, low multi-task adaptation efficiency, and poor interpretability. To overcome these limitations, this paper proposes a multimodal large language model (LLM) framework for unified PD condition assessment with causal interpretive capability. First, a PD signal unification module is developed to transform PD heterogeneous monitoring data into consistent token sequences, thereby mitigating sampling inconsistencies while retaining critical diagnostic features. Then, an LLM-based data augmentation module generates high-fidelity samples under defect-type and discharge-intensity constraints with self-correction and cross-modal consistency maintenance, alleviating data scarcity. Furthermore, a task-instructed prompt encoder and low-rank adaptation-based lightweight fine-tuning mechanism enable cross-modal semantic alignment and efficient task adaptation while improving interpretability and reducing computational cost. Experimental results demonstrate that the proposed framework achieves accuracies exceeding 98.5% across all tasks, substantially outperforming conventional approaches. The framework also provides interpretable textual reasoning that enhances diagnostic transparency and reliability, offering a promising pathway for intelligent condition assessment of GIS.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
A Multimodal Large Language Model Framework for Partial Discharge Condition Assessment in Gas-Insulated Switchgear
Artificial intelligence–enabled partial discharge (PD) condition assessment in gas-insulated switchgear (GIS) is essential for ensuring reliable operation of power equipment. However, existing methods face significant challenges in dealing with heterogeneous signal modalities, limited labeled data, low multi-task adaptation efficiency, and poor interpretability. To overcome these limitations, this paper proposes a multimodal large language model (LLM) framework for unified PD condition assessment with causal interpretive capability. First, a PD signal unification module is developed to transform PD heterogeneous monitoring data into consistent token sequences, thereby mitigating sampling inconsistencies while retaining critical diagnostic features. Then, an LLM-based data augmentation module generates high-fidelity samples under defect-type and discharge-intensity constraints with self-correction and cross-modal consistency maintenance, alleviating data scarcity. Furthermore, a task-instructed prompt encoder and low-rank adaptation-based lightweight fine-tuning mechanism enable cross-modal semantic alignment and efficient task adaptation while improving interpretability and reducing computational cost. Experimental results demonstrate that the proposed framework achieves accuracies exceeding 98.5% across all tasks, substantially outperforming conventional approaches. The framework also provides interpretable textual reasoning that enhances diagnostic transparency and reliability, offering a promising pathway for intelligent condition assessment of GIS.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Multi-Task Learning Network-Based Condition Assessment of GIS Partial Discharge: Diagnosis and Severity Evaluation
Current methods for assessing the state of partial discharge (PD) in gas-insulated switchgear (GIS) often treat the diagnosis and severity evaluation tasks independently, which limits model performance and overlooks the role of defect types in the PD development stages. To address these issues, this paper proposes a novel multi-task network for the condition assessment of PD in GIS. Firstly, a lightweight attention combined with an expert network module is introduced to explore the correlations between different tasks while retaining their unique features. Secondly, we incorporate a convolutional neural network (CNN)-Transformer module to capture both local and global features of GIS PD signals. Finally, we implement a dynamic weight averaging method for the multi-task network, which adaptively adjusts the loss weights via the variation rate of the losses of each sub-task. We conducted experiments on two GIS PD datasets with different insulating gases. Experimental results demonstrate that the multi-task network significantly improves the performance of each sub-task in GIS condition assessment, advancing the development stage evaluation of PD for various insulation defects. Furthermore, experiments on two types of insulating gases validate the generalization and versatility of the proposed method.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Multi-Task Learning Network-Based Condition Assessment of GIS Partial Discharge: Diagnosis and Severity Evaluation
Current methods for assessing the state of partial discharge (PD) in gas-insulated switchgear (GIS) often treat the diagnosis and severity evaluation tasks independently, which limits model performance and overlooks the role of defect types in the PD development stages. To address these issues, this paper proposes a novel multi-task network for the condition assessment of PD in GIS. Firstly, a lightweight attention combined with an expert network module is introduced to explore the correlations between different tasks while retaining their unique features. Secondly, we incorporate a convolutional neural network (CNN)-Transformer module to capture both local and global features of GIS PD signals. Finally, we implement a dynamic weight averaging method for the multi-task network, which adaptively adjusts the loss weights via the variation rate of the losses of each sub-task. We conducted experiments on two GIS PD datasets with different insulating gases. Experimental results demonstrate that the multi-task network significantly improves the performance of each sub-task in GIS condition assessment, advancing the development stage evaluation of PD for various insulation defects. Furthermore, experiments on two types of insulating gases validate the generalization and versatility of the proposed method.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Post-Arc Dielectric Recovery Characteristics of Liquid-Nitrogen Arcs in Cryogenic Hybrid DC Circuit Breakers
Liquid nitrogen has demonstrated promising DC interruption capability under cryogenic conditions, which may facilitate the realization of cryogenic hybrid DC circuit breaker. During interruptions, the liquid nitrogen gap must withstand the transient recovery voltage to prevent arc restrikes. However, existing studies mainly focus on gaseous media and vacuum. Dielectric strength recovery of liquid-nitrogen gaps remains absent. This paper aims to characterize the dielectric strength recovery behavior of liquid nitrogen gaps under different arc currents, arc duration and transverse magnetic fields. The results show that after the free burning arc extinguished, the dielectric strength of the liquid nitrogen gap follows a logarithmic regression function. Under a transverse magnetic field, the dielectric strength exhibits a two-stage logarithmic growth. The transverse magnetic field significantly enhances the dielectric strength recovery level of the liquid nitrogen gap. A 50 mT transverse magnetic field increases the withstand voltage by an average of 60% at 20 ms after arc extinction. However, the recovery rate and final dielectric strength level of the electrode gap do not increase with increasing magnetic field strength. The findings of this paper may provide support for insulation design of a hybrid DC circuit breakers employing liquid nitrogen as the arc-quenching medium, contributing to the feasibility of fault-protection strategies for superconducting DC electric-propulsion systems.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Post-Arc Dielectric Recovery Characteristics of Liquid-Nitrogen Arcs in Cryogenic Hybrid DC Circuit Breakers
Liquid nitrogen has demonstrated promising DC interruption capability under cryogenic conditions, which may facilitate the realization of cryogenic hybrid DC circuit breaker. During interruptions, the liquid nitrogen gap must withstand the transient recovery voltage to prevent arc restrikes. However, existing studies mainly focus on gaseous media and vacuum. Dielectric strength recovery of liquid-nitrogen gaps remains absent. This paper aims to characterize the dielectric strength recovery behavior of liquid nitrogen gaps under different arc currents, arc duration and transverse magnetic fields. The results show that after the free burning arc extinguished, the dielectric strength of the liquid nitrogen gap follows a logarithmic regression function. Under a transverse magnetic field, the dielectric strength exhibits a two-stage logarithmic growth. The transverse magnetic field significantly enhances the dielectric strength recovery level of the liquid nitrogen gap. A 50 mT transverse magnetic field increases the withstand voltage by an average of 60% at 20 ms after arc extinction. However, the recovery rate and final dielectric strength level of the electrode gap do not increase with increasing magnetic field strength. The findings of this paper may provide support for insulation design of a hybrid DC circuit breakers employing liquid nitrogen as the arc-quenching medium, contributing to the feasibility of fault-protection strategies for superconducting DC electric-propulsion systems.
- 10 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1529-1538
Small-Sample Partial Discharge Diagnosis for GIS Based on Improved Capsule Generative Adversarial Network and Dual-Mode Generator Optimization
Data-driven deep learning methods excel in gas insulated switchgear (GIS) partial discharge (PD) diagnosis, but their performance falters in data-scarce scenarios. Constrained by the intricate operating environment of GIS and the transient and stochastic nature of PD, acquiring sufficient PD samples in practical applications remains challenging. Therefore, this paper proposes an improved capsule generative adversarial network (GAN) for small-sample GIS PD diagnosis. Firstly, capsule network is introduced in both the generator and the discriminator to extract more comprehensive feature information from PD signals, thus avoiding the potential loss of crucial features due to pooling operations. Then, a dual-mode optimization method is used to update the model parameters of the generator, and sample quality and diversity are used as evaluation indicators to guide the training process of the generator, realizing automatic optimization of generator parameter-level model construction. Meanwhile, the discriminator stabilizes the GAN training by adopting the Wasserstein distance and incorporating a gradient penalty term. Experimental results show that the proposed method achieves diagnostic accuracy of 97.47% in small datasets, significantly outperforming other methods and exhibiting robust performance, provides a viable solution for high-precision and robust GIS PD diagnosis with limited samples.
- 10 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1529-1538
Small-Sample Partial Discharge Diagnosis for GIS Based on Improved Capsule Generative Adversarial Network and Dual-Mode Generator Optimization
Data-driven deep learning methods excel in gas insulated switchgear (GIS) partial discharge (PD) diagnosis, but their performance falters in data-scarce scenarios. Constrained by the intricate operating environment of GIS and the transient and stochastic nature of PD, acquiring sufficient PD samples in practical applications remains challenging. Therefore, this paper proposes an improved capsule generative adversarial network (GAN) for small-sample GIS PD diagnosis. Firstly, capsule network is introduced in both the generator and the discriminator to extract more comprehensive feature information from PD signals, thus avoiding the potential loss of crucial features due to pooling operations. Then, a dual-mode optimization method is used to update the model parameters of the generator, and sample quality and diversity are used as evaluation indicators to guide the training process of the generator, realizing automatic optimization of generator parameter-level model construction. Meanwhile, the discriminator stabilizes the GAN training by adopting the Wasserstein distance and incorporating a gradient penalty term. Experimental results show that the proposed method achieves diagnostic accuracy of 97.47% in small datasets, significantly outperforming other methods and exhibiting robust performance, provides a viable solution for high-precision and robust GIS PD diagnosis with limited samples.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Effects of Single Narrow Neck of SUS Layer on AC Current-Limiting and Interrupting Characteristics of Superconducting Fuse
High temperature superconductor (HTS) can be used to limit and interrupt fault current as a fuse. However, the narrow neck on the side of the tape causes lower and unstable critical current, which makes its application difficult. In this paper, we proposed a new type of superconducting fuse with a narrow neck manufactured in a stainless-steel (SUS) reinforcement layer, which can hold the critical current and enhance the fusing ability. An experimental model was established with an impact source. The AC current limiting and fusing tests were conducted with the new superconducting fuse and the fuse without a narrow neck. Experimental results show that compared to the fuse without a narrow neck, the new superconducting fuse achieves a reduction of at least 40 A in peak current, an increase of at least 77.4% in arc voltage, a decrease of at least 17% in front arc I^2t, and a shorting of at least 0.872 ms in pre-arcing time. The superior current-limiting and fusing capabilities of the new superconducting fuse can help protect superconducting devices during fault conditions.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Effects of Single Narrow Neck of SUS Layer on AC Current-Limiting and Interrupting Characteristics of Superconducting Fuse
High temperature superconductor (HTS) can be used to limit and interrupt fault current as a fuse. However, the narrow neck on the side of the tape causes lower and unstable critical current, which makes its application difficult. In this paper, we proposed a new type of superconducting fuse with a narrow neck manufactured in a stainless-steel (SUS) reinforcement layer, which can hold the critical current and enhance the fusing ability. An experimental model was established with an impact source. The AC current limiting and fusing tests were conducted with the new superconducting fuse and the fuse without a narrow neck. Experimental results show that compared to the fuse without a narrow neck, the new superconducting fuse achieves a reduction of at least 40 A in peak current, an increase of at least 77.4% in arc voltage, a decrease of at least 17% in front arc I^2t, and a shorting of at least 0.872 ms in pre-arcing time. The superior current-limiting and fusing capabilities of the new superconducting fuse can help protect superconducting devices during fault conditions.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Load Recovery Performances of Variable Impedance Superconducting Fault Current Limiting Transformers
The Superconducting Fault Current Limiting Transformers (SFCLTs) offer significant advantages such as large capacity and high efficiency. However, a challenge arises in maintaining power transmission during some short-circuit fault conditions, as this may lead to the inability of superconducting tapes to recover from quenching, resulting in damage due to overheating. A variable impedance superconducting fault current limiting transformer (VI-SFCLT) was designed as two parallel superconducting branches in a secondary winding to recover seamlessly with the system load after fault current limitation. In this manuscript, an experimental platform is constructed to test the current limiting and recovery performance of the VI-SFCLT under load current after a fault. The experimental results demonstrate that the proposed VI-SFCLT can limit the fault current to 40% lower than the normal SFCLT. The joule heat of the VI-SFCLT can be 78.3% of the normal SFCLT with the increase of fault duration, and the recovery time is at least 26.2% shorter. By incorporating a fast switch, VI-SFCLT achieves rapid recovery with load current, thereby enhancing the stability of the power grid.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-6
Load Recovery Performances of Variable Impedance Superconducting Fault Current Limiting Transformers
The Superconducting Fault Current Limiting Transformers (SFCLTs) offer significant advantages such as large capacity and high efficiency. However, a challenge arises in maintaining power transmission during some short-circuit fault conditions, as this may lead to the inability of superconducting tapes to recover from quenching, resulting in damage due to overheating. A variable impedance superconducting fault current limiting transformer (VI-SFCLT) was designed as two parallel superconducting branches in a secondary winding to recover seamlessly with the system load after fault current limitation. In this manuscript, an experimental platform is constructed to test the current limiting and recovery performance of the VI-SFCLT under load current after a fault. The experimental results demonstrate that the proposed VI-SFCLT can limit the fault current to 40% lower than the normal SFCLT. The joule heat of the VI-SFCLT can be 78.3% of the normal SFCLT with the increase of fault duration, and the recovery time is at least 26.2% shorter. By incorporating a fast switch, VI-SFCLT achieves rapid recovery with load current, thereby enhancing the stability of the power grid.